Measurement of the X-ray emission of the solar atmosphere during a period of low activity

A large-area high-sensitivity X-ray spectrometer has been constructed and used to measure the 1.8- to 5.3-A X-ray emission of the sun under quiescent conditions. The instrument utilizes Bragg reflection from mosaic graphite crystals. The data indicate that the X-ray emission can best be accounted for by a multitemperature model of the solar atmosphere in which both the overall corona and active regions contribute to the X-ray spectrum. Theoretical calculations of the X-ray flux of a hot, optically thin plasma have been used to estimate the solar conditions at the time when the measurements were made.

Wolff, R. S.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

Chemical composition of cosmic rays with Z greater than or equal to 30 and E greater than or equal to 325 MeV/N

Results are presented on the chemical composition of VVH cosmic rays from a series of six high-altitude balloon flights of a large-area, high-resolution electronic detector. The charge composition in the 32 less than or equal to Z less than or equal to 45 interval is found to be inconsistent with S-process nucleosynthesis. The energy spectrum of particles with Z greater than or equal to 32 between 600 and 1500 MeV/N at the top of the atmosphere is measured and is found to be consistent with the 25 less than or equal to Z less than or equal to 27 group within experimental error.

Binns, W. R.↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Thermal study of the unilluminated surface of the waning moon

A program of lunar infrared radiometry which uses large-area scanning is described. Procedures for atmospheric-attenuation correction and data reduction to temperature by relative radiometry are outlined. The scan data of the waning moon taken during ten evenings in the 10- to 12-micron window are presented as isothermal contour maps of the lunar disk. More than 160 areas of anomalous thermal emission have been found in the lunar dark-side data. These are tabulated and are also shown on an accompanying map. An error analysis, derived from accuracy estimates of the independent parameters, is included.

Raine, W. L.↗

A new computer approach to mixed feature classification for forestry application

A computer approach for mapping mixed forest features (i.e., types, classes) from computer classification maps is discussed. Mixed features such as mixed softwood/hardwood stands are treated as admixtures of softwood and hardwood areas. Large-area mixed features are identified and small-area features neglected when the nominal size of a mixed feature can be specified. The computer program merges small isolated areas into surrounding areas by the iterative manipulation of the postprocessing algorithm that eliminates small connected sets. For a forestry application, computer-classified LANDSAT multispectral scanner data of the Sam Houston National Forest were used to demonstrate the proposed approach. The technique was successful in cleaning the salt-and-pepper appearance of multiclass classification maps and in mapping admixtures of softwood areas and hardwood areas. However, the computer-mapped mixed areas matched very poorly with the ground truth because of inadequate resolution and inappropriate definition of mixed features.

Kan, E. P.↗

Stellar crystal X-ray spectroscopy on OSO-8

The large-area graphite crystal X-ray spectrometer on the OSO-8 satellite is described, and its response to stellar line and continuum radiation is discussed. A high resolution X-ray spectrum of Sco X-1 obtained from a preliminary analysis of quick look data shows a strong, smooth continuum with an absence of emission or absorption features over the energy range 2.2 to 8 keV. Upper limits are set on narrow line emission from highly ionized states of S, Ca, and Fe.

Kestenbaum, H. L.↗

The Hard X-ray experiment on the Astronomical Netherlands Satellite

The Hard X-ray Experiment flown on the Astronomical Netherlands Satellite is described. The instrument consists of two parts. One is a large-area detector of about 60 sq cm in total area, sensitive in the energy range between 1.5 and 30 keV. Two counters comprise this detector, each collimated 10 min by 3 deg and offset in the narrow direction by 4 min. The other part is a Bragg-crystal assembly consisting of two PET crystals and counters aligned to search for the silicon emission lines near 2 keV. Instrument characteristics and orbital operations are described.

Gursky, H.↗

Exploration for fossil and nuclear fuels from orbital altitudes

A review of satellite-based photographic (optical and infrared) and microwave exploration and large-area mapping of the earth's surface in the ERTS program. Synoptic cloud-free coverage of large areas has been achieved with planimetric vertical views of the earth's surface useful in compiling close-to-orthographic mosaics. Radar penetration of cloud cover and infrared penetration of forest cover have been successful to some extent. Geological applications include map editing (with corrections in scale and computer processing of images), landforms analysis, structural geology studies, lithological identification, and exploration for minerals and fuels. Limitations of the method are noted.

Short, N. M.↗

New observations of pulsed X-ray emission from NP 0532

Large-area proportional counters sensitive from 0.6 to 23 keV were used to observe about 3 min of pulsed X-ray emission from NP 0532 during two lunar-occultation experiments. A detailed pulse profile with 65-microsec resolution shows that the X-ray primary-pulse shape is essentially identical to its optical counterpart. Spectral data on the pulsed X-ray emission are presented. A pulse-by-pulse examination of the data shows no evidence for temporal variability.

Kestenbaum, H. L.↗

The detection of high charge cosmic ray nuclei

A large-area, light-weight electronic particle telescope was flown on a high altitude balloon in the summer of 1974 to study the heavy nuclei in the cosmic radiation. This telescope consisted of a double Cerenkov-double scintillator array composed of four 1.22 m diameter disk radiators mounted in light diffusion boxes, each looked at by multiple photomultipliers. The impact point of each particle on the scintillation radiators was determined by studying the relative signals observed by three equally spaced peripheral photomultipliers and one mounted at the center of the diffusion boxes. This telescope was flown in a configuration having a geometric factor of 0.45 sq m sr and observed some 5 x 10 to the 4 nuclei with Z exceeding 14 in a 11 hr exposure. The response and sensitivity of this telescope are discussed in detail.

Scarlett, W. R.↗

Upper limits to the quiet-time solar neutron flux from 10 to 100 MeV

A large-area solid-angle double-scatter neutron telescope was flown to search for solar neutrons on three balloon flights in 1971 and 1972. The first two flights were launched from Palestine, Texas, and the third from Cape Girardeau, Missouri. The float altitude on each flight was at about 5 g/sq cm residual atmosphere. Neutrons from 10 to 100 MeV were measured. No solar flares occurred during the flights. Upper limits to the quiet-time solar neutron fluxes at the 95-per cent confidence level are 2.8, 4.6, 9.6, and 9.0 x 10 to the -4th power neutron/sq cm/sec in the energy intervals of 10-30, 30-50, 50-100, and 10-100 MeV, respectively.

Moon, S.↗

Measurement of the primary cosmic electron spectrum from 10 to about 250 GeV

The intensity and energy spectrum of primary cosmic electrons from 10 to about 250 GeV have been studied by using balloon-borne detectors. The detectors were large-area ionization calorimeters which sampled showering particles frequently and demonstrated an energy resolution of about 7% in calibration tests. On one of the flights a time-of-flight system and detectors to sample the lateral properties of showers were used to examine and to test background rejection. The results of the balloon flights from Alamogordo, N. Mex., in 1970 and Cape Girardeau, Mo., in 1972 indicated that the primary cosmic ray electron differential energy spectrum exhibits no change of slope in the energy range measured and is well represented by a power law. The results indicate that the cosmic electron spectrum is steeper than the cosmic ray proton spectrum. It is shown that these data are consistent with the leakage lifetime model for the propagation of cosmic electrons in the galaxy, although other more complex models cannot be excluded on the basis of these data.

Silverberg, R. F.↗

Columbia University OSO-8 instrument for stellar and solar X-ray spectroscopy and polarimetry

A spectrometer and a polarimeter consisting of large-area panels of mosaic crystals have been constructed and prepared for use in the OSO-8 satellite. The instrumentation is planned for study of stellar and solar X-ray spectra between 1.8-8 keV and stellar X-ray polarization at 2.6 keV. Aspects of the design which enable the instrument to make measurements of the diverse range of stellar and solar phenomena are described. Some of the unique features, such as high sensitivity, high temporal resolution, and spectral range, are discussed. The applicability of the spectrometer and polarimeter to various current problems in X-ray astronomy is considered.

Wolff, R. S.↗

Application of NASTRAN to large space structures

The application of NASTRAN to design studies of two very large-area lightweight structures is described. The first is the Satellite Solar Power Station, while the second is a deployable three hundred meter diameter antenna. A brief discussion of the operation of the SSPS is given, followed by a description of the structure. The use of the NASTRAN program for static, vibration and thermal analysis is illustrated and some results are given. Next, the deployable antenna is discussed and the use of NASTRAN for static analysis, buckling analysis and vibration analysis is detailed.

Balderes, T.↗

A backside illuminated 400 x 400 charge-coupled device imager

Large-area backside illuminated charge-coupled device imagers have been fabricated using double level aluminum transfer electrode technology. Devices with 100 x 160 and 400 x 400 resolution elements have been fabricated using buried channel technology for high charge transfer efficiency. Detailed optical characterization has been performed on these imagers over the temperature range -40 to +24 C and at several operating frequencies between 10 kHz and 1 MHz.

Antcliffe, G. A.↗

The graphite crystal X-ray spectrometer on OSO-8

The large-area graphite crystal X-ray spectrometer aboard the OSO-8 satellite is described. The instrument can be used to measure continuum profiles over the energy band from 2 to 8 keV with a resolution of several tens of electron volts and to detect narrow line emission from strong X-ray sources with a limiting sensitivity (3 sigmas) of the order of 10-eV, equivalent width for a three-day observing period.

Kestenbaum, H. L.↗

Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

Wagner, L. J.↗