Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser based measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Benchmark cyclic plastic notch strain measurements

Plastic strains at the roots of notched specimens of Inconel 718 subjected to tension-compression cycling at 650 C are reported. These strains were measured with a laser-based technique over a gage length of 0.1 mm and are intended to serve as 'benchmark' data for further development of experimental, analytical, and computational approaches. The specimens were 250 mm by 2.5 mm in the test section with double notches of 4.9 mm radius subjected to axial loading sufficient to cause yielding at the notch root on the tensile portion of the first cycle. The tests were run for 1000 cycles at 10 cpm or until cracks initiated at the notch root. The experimental techniques are described, and then representative data for the various load spectra are presented. All the data for each cycle of every test are available on floppy disks from NASA.

Sharpe, W. N., Jr.↗

Eddy correlation measurements of methane fluxes using a tunable diode laser at the Kinosheo Lake tower site during the Northern Wetlands Study (NOWES)

As part of the Canadian Northern Wetlands Study (NOWES) measurements of methane flux were made at the Kinosheo Lake tower site for a 1-month period during the 1990 summer intensive. The measurements were made with a diode-laser-based methane sensor using the eddy correlation technique. Measurements of the methane fluxes were made at two levels, 5 or 18 m. Approximately 900 half-hour average methane flux measurements were obtained. Weak temporal and diurnal trends were observed in the data. Fluxes averaged over the study period showed an overall methane emission of 16 mg CH4 m(exp -2)/d with a daytime average of 20 mg CH4 m(exp -2)/d and a nighttime average of 9 mg CH4 m(exp -2)/d. The effect of emission footprint was evident in the data. A strong relationship between the daily average methane flux and wet bog temperature at 20-cm depth was observed.

Edwards, G. C.↗

Aerodynamic measurement techniques

Laser characteristics of intensity, monochromatic, spatial coherence, and temporal coherence were developed to advance laser based diagnostic techniques for aerodynamic related research. Two broad categories of visualization and optical measurements were considered, and three techniques received significant attention. These are holography, laser velocimetry, and Raman scattering. Examples of the quantitative laser velocimeter and Raman scattering measurements of velocity, temperature, and density indicated the potential of these nonintrusive techniques.

Hunter, W. W., Jr.↗

Antimisting fuel breakup and flammability

The breakup behavior and flammability of antimisting turbine fuels subjected to aerodynamic shear are investigated. Fuels tested were Jet A containing 0.3% FM-9 polymer at various levels of degradation ranging from virgin AMK to neat Jet A. The misting behavior of the fuels was quantified by droplet size distribution measurements. A technique based on high resolution laser photography and digital image processing of photographic records for rapid determination of droplet size distribution was developed. The flammability of flowing droplet-air mixtures was quantified by direct measurements of temperature rise in a flame established in the wake of a continuous ignition source. The temperature rise measurements were correlated with droplet size measurements. The flame anchoring phenomenon associated with the breakup of a liquid fuel in the wake of bluff body was shown to be important in the context of a survivable crash scenario. A pass/fail criterion for flammability testing of antimisting fuels, based on this flame-anchoring phenomenon, was proposed. The role of various ignition sources and their intensity in ignition and post-ignition behavior of antimisting fuels was also investigated.

Parikh, P.↗

Pulsed laminar falling films in vertical tubes: Maintaining a continuous liquid film with reduced film thickness

Falling-liquid-film heat transfer is important to a wide variety of industrial applications, including two-phase thermosyphons, falling-film evaporators in the food industry, heat exchangers in fuel-ethanol processing, and the chemical service industry. Particularly for laminar falling films, the heat transfer increases as the film thickness decreases, hence it is desirable to keep the films as thin as possible. This article presents a periodically-pulsed flow concept to reduce the average mass flow inside a vertical tube. The technique provides thinner films than can be achieved with continuous flow. A drainage model is adopted to predict the film thickness as a function of flow rate and location along the tube. The concept is confirmed experimentally by measuring the film thickness in real time in a circular tube using a laser-based absorption technique. A new heat-transfer-based film continuity measurement is also integrated into the optical film measurement setup. Water at ambient temperature and pressure is used for this work. Film thickness reductions of up to 60%, and liquid-film volume-flow reductions of up to 80% compared to the minimum continuous-flow film have been obtained. The time-varying film thickness profile can also be controlled to a limited extent, which may be of interest for process industries.

42 ENGINEERING↗

Microspheres for laser velocimetry in high temperature wind tunnel

The introduction of non-intrusive measurement techniques in wind tunnel experimentation has been a turning point in error free data acquisition. Laser velocimetry has been progressively implemented and utilized in various wind tunnels; e.g. subsonic, transonic, and supersonic. The success of the laser velocimeter technique is based on an accurate measurement of scattered light by seeding particles introduced into the flow stream in the wind tunnel. Therefore, application of appropriate seeding particles will affect, to a large extent the acquired data. The seeding material used depends on the type of experiment being run. Among the seeding material for subsonic tunnel are kerosene, Kaolin, and polystyrene. Polystyrene is known to be the best because of being solid particles, having high index of refraction, capable of being made both spherical and monodisperse. However for high temperature wind tunnel testing seeding material must have an additional characteristic that is high melting point. Typically metal oxide powders such as Al2O3 with melting point 3660 F are used. The metal oxides are, however polydispersed, have a high density, and a tendency to form large agglomerate that does not closely follow the flow velocity. The addition of flame phase silica to metal oxide helps to break up the agglomerates, yet still results in a narrow band of polydispersed seeding. The less desirable utility of metal oxide in high temperature wind tunnels necessitates the search for a better alternative particle seeding which this paper addresses. The Laser Velocimetry (LV) characteristic of polystyrene makes it a prime candidate as a base material in achieving the high temperature particle seeding inexpensively. While polystyrene monodisperse seeding particle reported has been successful in a subsonic wind tunnel, it lacks the high melting point and thus is not practically usable in a high temperature wind tunnel. It is well known that rise in melting point of polystyrene can be achieved by a cross-linking technique. Since polystyrene already possesses all the desired characteristics for LV, to circumvent the low melting point, a cross-linking technique was investigated.

Ghorieshi, Anthony↗

Two-Color Laser Speckle Shift Strain Measurement System

A two color laser speckle shift strain measurement system based on the technique of Yamaguchi was designed. The dual wavelength light output from an Argon Ion laser was coupled into two separate single-mode optical fibers (patchcords). The output of the patchcords is incident on the test specimen (here a structural fiber). Strain on the fiber, in one direction, is produced using an Instron 4502. Shifting interference patterns or speckle patterns will be detected at real-time rates using 2 CCD cameras with image processing performed by a hardware correlator. Strain detected in fibers with diameters from 21 microns to 143 microns is expected to be resolved to 15 mu epsilon. This system was designed to be compact and robust and does not require surface preparation of the structural fibers.

Tuma, Margaret L.↗

Semiconductor Laser Linewidth Measurements for Space Interferometry Applications

Narrow linewidth (<100KHz) semiconductor lasers are expected to be a key technology in NASA's stellar interferometry missions to search for planets around nearby stars. Long coherence length lasers are needed for precise (20 pm to 5 mn) measurements of the optical path difference. This work discusses results using the self-heterodyne delay technique to measure 1.3 micrometer InP based DFB lasers. We will also address practical issues concerning detection and elimination of back reflections, choice of fiber length and resolution, and measurement of laser 1/f and current supply noise.

Dougherty, D. J.↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular-Based Optical Measurement Techniques for Transition and Turbulence in High-Speed Flow

High-speed laminar-to-turbulent transition and turbulence affect the control of flight vehicles, the heat transfer rate to a flight vehicle's surface, the material selected to protect such vehicles from high heating loads, the ultimate weight of a flight vehicle due to the presence of thermal protection systems, the efficiency of fuel-air mixing processes in high-speed combustion applications, etc. Gaining a fundamental understanding of the physical mechanisms involved in the transition process will lead to the development of predictive capabilities that can identify transition location and its impact on parameters like surface heating. Currently, there is no general theory that can completely describe the transition-to-turbulence process. However, transition research has led to the identification of the predominant pathways by which this process occurs. For a truly physics-based model of transition to be developed, the individual stages in the paths leading to the onset of fully turbulent flow must be well understood. This requires that each pathway be computationally modeled and experimentally characterized and validated. This may also lead to the discovery of new physical pathways. This document is intended to describe molecular based measurement techniques that have been developed, addressing the needs of the high-speed transition-to-turbulence and high-speed turbulence research fields. In particular, we focus on techniques that have either been used to study high speed transition and turbulence or techniques that show promise for studying these flows. This review is not exhaustive. In addition to the probe-based techniques described in the previous paragraph, several other classes of measurement techniques that are, or could be, used to study high speed transition and turbulence are excluded from this manuscript. For example, surface measurement techniques such as pressure and temperature paint, phosphor thermography, skin friction measurements and photogrammetry (for model attitude and deformation measurement) are excluded to limit the scope of this report. Other physical probes such as heat flux gauges, total temperature probes are also excluded. We further exclude measurement techniques that require particle seeding though particle based methods may still be useful in many high speed flow applications. This manuscript details some of the more widely used molecular-based measurement techniques for studying transition and turbulence: laser-induced fluorescence (LIF), Rayleigh and Raman Scattering and coherent anti-Stokes Raman scattering (CARS). These techniques are emphasized, in part, because of the prior experience of the authors. Additional molecular based techniques are described, albeit in less detail. Where possible, an effort is made to compare the relative advantages and disadvantages of the various measurement techniques, although these comparisons can be subjective views of the authors. Finally, the manuscript concludes by evaluating the different measurement techniques in view of the precision requirements described in this chapter. Additional requirements and considerations are discussed to assist with choosing an optical measurement technique for a given application.

Bathel, Brett F.↗

Laser techniques for arc jet plasma diagnostics; continuation of a feasibility and design study

This study is concerned with the continuation of a feasibility and design study of laser-based diagnostic techniques for the non-instrusive measurement of species concentrations, temperatures, and velocity in the low density, high enthalpy flow through the arc-heated wind tunnel facility (ARMSEF) at NASA/JSC. Last summer several laser-induced radiation scattering methods were investigated and some preliminary measurements of the spectral distribution of radiation emitted by the arc-heated gas flow were made. Based upon those preliminary measurements and subsequent investigations, four laser-induced radiation scattering methods were selected for further detailed study, and preliminary design of a measurement system has been undertaken. Further measurements of the spectral distribution of radiation emitted from the arc-heated free stream and shock layer flows, using a redesigned measurement system, have been made for one axial position in the flow for a range of tunnel operating power levels. Further study of the literature for physical property data, theoretical models of processes, and applications of the diagnostic methods has been also carried out.

Wierum, F. A.↗

Wind Tunnel Seeding Systems for Laser Velocimeters

The principal motivating factor for convening the Workshop on the Development and Application of Wind Tunnel Seeding Systems for Laser Velocimeters is the necessity to achieve efficient operation and, most importantly, to insure accurate measurements with velocimeter techniques. The ultimate accuracy of particle scattering based laser velocimeter measurements of wind tunnel flow fields depends on the ability of the scattering particle to faithfully track the local flow field in which it is embedded. A complex relationship exists between the particle motion and the local flow field. This relationship is dependent on particle size, size distribution, shape, and density. To quantify the accuracy of the velocimeter measurements of the flow field, the researcher has to know the scattering particle characteristics. In order to obtain optimum velocimeter measurements, the researcher is striving to achieve control of the particle characteristics and to verify those characteristics at the measurement point. Additionally, the researcher is attempting to achieve maximum measurement efficiency through control of particle concentration and location in the flow field.

Hunter, W. W., Jr.↗

Pseudorandom Noise Code-Based Technique for Thin Cloud Discrimination with CO2 and O2 Absorption Measurements

NASA Langley Research Center is working on a continuous wave (CW) laser based remote sensing scheme for the detection of CO2 and O2 from space based platforms suitable for ACTIVE SENSING OF CO2 EMISSIONS OVER NIGHTS, DAYS, AND SEASONS (ASCENDS) mission. ASCENDS is a future space-based mission to determine the global distribution of sources and sinks of atmospheric carbon dioxide (CO2). A unique, multi-frequency, intensity modulated CW (IMCW) laser absorption spectrometer (LAS) operating at 1.57 micron for CO2 sensing has been developed. Effective aerosol and cloud discrimination techniques are being investigated in order to determine concentration values with accuracies less than 0.3%. In this paper, we discuss the demonstration of a pseudo noise (PN) code based technique for cloud and aerosol discrimination applications. The possibility of using maximum length (ML)-sequences for range and absorption measurements is investigated. A simple model for accomplishing this objective is formulated, Proof-of-concept experiments carried out using SONAR based LIDAR simulator that was built using simple audio hardware provided promising results for extension into optical wavelengths.

Campbell, Joel F.↗

A 2-lambda laser-induced flurorescence field instrument for ground-based and airborne measurements of atmospheric OH

A number of techniques have been proposed for detecting atmospheric OH radicals. Of these, the laser-induced fluorescence (LIF) technique has been used by the largest number of investigators. One of the problems arising in connection with the implementation of this technique is related to the perturbing effect of the UV (lambda approximately 282 nm) laser beam used for OH monitoring, while another problem relates to signal extraction. Several new LIF approaches have been or are currently under development with the objective to bring both problems under control. The present paper deals with the experimental features of one of these new approaches. The considered approach is referred to as 2-lambda laser-induced fluorescence (2-lambda LIF). It is shown that the 2-lambda LIF system provides significant advantages over earlier 1-lambda LIF OH measurement instruments operating at ambient pressure.

Rodgers, M. O.↗

Implementation of a Doppler-Free Saturation Spectroscopy (DFSS) Diagnostic for Helicon Wave Electric Field Vector Measurement in Edge Plasma in DIII-D

A laser-based technique known as Doppler-free saturation spectroscopy (DFSS) has been designed, fabricated, and installed on the DIII-D National Fusion Facility to measure the helicon wave electric field vector in the edge plasma. These experimental measurements quantify phenomena resulting in decreased current drive efficiency due to wave/edge plasma interactions. This implementation of DFSS on DIII-D is the first of its kind on a tokamak and thus presents unique engineering challenges, including integration of the system onto an existing multidiagnostic port flange without impacts to system serviceability, as well as maintaining precise laser alignment over a 2-m distance during disruptions and thermal drift of the vessel. Further, these challenges were resolved using innovative design approaches such as a novel decoupled shutter system to facilitate serviceability of the in-vessel mirror assemblies without the need for personnel vessel entry, as well as an ex-vessel piezo-mirror-based optical system for laser beam shaping and real-time steering of the measurement location. The solutions to these engineering challenges were demonstrated during the successful installation and operation of these diagnostic components during the 2022 DIII-D vent and subsequent experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstrate the Out-of-Pile Performance of a Real-Time Measurement System to Measure Thermal Conductivity Based on Photo Thermal Radiometry

SUMMARY The goal of this project is to develop a fiber-based instrument to perform in-reactor thermal conductivity measurements of fuels and materials. This instrument is based on photothermal radiometry (PTR) and involves heating a sample locally and measuring the induced temperature gradient by collecting blackbody radiation [2]. Thermal conductivity of the sample is extracted by comparing experimental results with a continuum-based model [3,4]. As a laser-based technique, PTR is a non-contact measurement technique that can be performed remotely and non-destructively. In addition, it has several advantages over other photothermal techniques, making it an ideal approach for in-situ measurement of thermal conductivity of nuclear fuels. Because blackbody radiation increases with emissivity and temperature, the PTR technique works well with unprepared surfaces, and measurement accuracy increases with temperature. Moreover, this approach is capable of measuring samples with irregular or poorly defined boundary conditions, which is a common situation for friable spent fuels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of Irradiation-induced Microstructural Defects on Thermal Transport in Single Crystal Thorium Dioxide

Microstructural defects formed as a result of fission fragment damage are known to drastically alter thermal conductivity, a fuel property that governs the efficiency of a nuclear reactor. A fundamental understanding of radiation-induced effects on thermal transport is critical for the development of advanced fuels. Ion-irradiation has widely been used to simulate the effects of neutron-irradiation by seeding atomic-to-nanoscale defects of controllable size and density. In this work, we investigate the influence of microstructural defects, induced by ion-irradiation, on the thermal properties of single crystal thorium dioxide samples grown using the hydrothermal technique. The samples were irradiated using 2 MeV protons at room temperature. A laser-based modulated thermoreflectance technique was used to measure the thermal diffusivity and conductivity within the damaged ThO2 region. The experimentally measured thermal properties were compared with Boltzmann Transport Equation predictions, to determine the impact of various defect types on the thermal properties of ThO2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

100-kHz Interferometric Rayleigh Scattering Flow Diagnostics at 266 nm

Interferometric Rayleigh scattering (IRS) is a laser-based technique capable of spatially and temporally resolved measurement of gas velocity and temperature in unseeded gaseous flows. In the present embodiment of the technique, IRS is performed at 266 nm for the first time. IRS at 266 nm is potentially much less susceptible to interferences from particles and other stray light sources. A pulse-burst laser and high-speed camera provided image rates of 100 kHz, allowing simultaneous space- and time-resolved measurement in high speed flow at multiple points along a line. The use of 266 nm excitation and detection is compared with prior work that used 532 nm. New experimental interferogram modelling and fitting techniques for single and multi-velocity-component IRS were demonstrated in a study of the spatial and temporal variation of the flow along a line through a supersonic jet. Single component velocity and temperature measurements using 266 nm were successfully made and compared with prior 532 nm results. Two-component velocity measurements at 266 nm, using the reflected image method, were compared to single-component measurements.

Andrew D Cutler↗