Search NASA⌕ Search

SEARCH · Search NASA

Results for “load flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-connected heat pump water heater benefits for low-income households in the Southeastern United States

Energy efficient heat pump water heaters (HPWHs) reduce customer energy costs; grid-connected controls further increase HPWH value by enabling energy storage and shifting demand to cheaper, off-peak periods. However, a HPWH’s first cost premium can put it out of reach for low-income customers. This paper will present results of an ongoing study exploring the benefits of load shifting HPWHs for 24 low-income households, aiming to support increased product deployment in this demographic. The study uses EcoPort modules to shift HPWH load for a study sample consisting primarily of low-income adults and seniors in North Carolina. Building upon prior studies, the study’s HPWH operating schedules are designed to maximize shifted energy and minimize participant electricity costs based on local time-of-use rates. The study documents load profiles of grid-connected HPWHs in a less-studied demographic group and explores how certain groups may have particularly flexible loads due to their unique usage profiles. The results are relevant for HPWH product performance in the Southeast. The study will quantify HPWH load shifting performance during North Carolina’s hot summer, temperate shoulder, and occasionally sub-freezing winter seasons, and the study includes installations in conditioned, semi-conditioned, and unconditioned spaces. Finally, study results will also explore how controlled HPWHs can provide value to the regional grid by reducing seasonal peaks via demand response. Lessons learned include HPWH acceptance for low-income and senior users, best practices for maintaining HPWH connectivity among users without prior product experience, and strategies to leverage remote monitoring to ensure optimal operation and enhance HPWH reliability.

Urigwe, Daniela↗

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Green co-solvent-assisted one-pot synthesis of high-performance flexible lignin polyurethane foam

Although lignin is a promising candidate as a source of polyol for producing eco-friendly polyurethane foam (PUF), its direct application has limitations, primarily stemming from the brittleness of the resulting products and poor processibility at high lignin loadings. To address these technical challenges, we introduced an effective co-solvent for the lignin-based polyurethane foams (LPUFs) with up to 80wt% of lignin substitution for petroleum polyols. As a green co-solvent that involves carbon dioxide fixation during its production, propylene carbonate (PC), was blended with lignin and improved the distribution of lignin by decreasing the viscosity, providing a room-temperature reaction. The LPUFs demonstrated a comparable thermal insulation performance (R-values greater than 5 in -1 ) with commercially available PUF with a uniform size of closed-cell structure induced by the reduced viscosity of lignin-based polyol. LPUFs also showed enhanced fire retardancy and moisture resistance compared to the control PUFs, benefiting from lignin’s intrinsic fire-resistant and hydrophobic properties. To mitigate the brittleness issue at high lignin loadings, flexible polyethylene glycols (PEGs) with a high molecular weight (i.e., PEG-1000) were dissolved in PC at room temperature to further improve the mechanical strength of LPUFs. The compressive strength of LPUFs with 80 wt% lignin substitution content was remarkably improved to 226 kPa by the employment of co-solvent and PEG-1000 compared to the control PUF (<140 kPa). Moreover, the flexibility of the LPUFs was successfully controlled by simply adjusting the PEG-400/PEG-1000 ratio. In conclusion, the results of this study provide valuable insights for accelerating and broadening the utilization of lignin in sustainable materials and manufacturing areas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of finite element analysis of a piping tee using NASTRAN and CORTES/SA

A comparison of finite element analyses of a piping tee was made using NASTRAN and CORTES/SA, a modified version of SAP3 having a special purpose input processor for generating geometries for a wide variety of tee joints. Four finite element models were subjected in force, moment, and pressure loadings. Flexibility factors and principal stresses were computed for each model and compared with results obtained experimentally by Combustion Engineering, Inc. Results from the NASTRAN analyses were in good agreement with experimental results for all loadings except internal pressure. The CORTES/SA analyses gave good results for the internal pressure loading, but poorer results for out of plane bending moments or forces resulting in out of plane bending. Two of the basic load cases in CORTES/SA were found to contain errors that could not be easily corrected. COST COMPARison of NASTRAN and CORTES/SA showed NASTRAN to be less expensive to two than CORTES/SA for identical meshes.

Quezon, A. J.↗

Design trade-offs for residential retail tariffs and virtual power plants

Retail rate design and virtual power plants (VPPs) have the potential to shift customer electricity demand and provide economic benefits to utility customers. As the adoption of distributed energy resources (DERs) and flexible loads increases, retail tariff and program design can impact Bonbright's rate design principles including affordability, fairness, and economic efficiency. We model the effects of residential retail rates and VPP programs on power system costs in Massachusetts under a potential future system with high renewable energy and DER adoption. We model interactions among retail rate design, demand flexibility, and utility costs and identify trade-offs across different rate designs and VPP programs. We estimate that time-of-use (TOU) rates and VPP programs designed to avoid critical peak rates can lower overall system costs by 3.5 %-4.8 %. These lower costs translate to lower electricity bills for 62 %-91 % of customers, depending on the scenario. Although TOU rates with a critical peak VPP program can benefit all customer segments and are economically efficient, a VPP program with flat rates leads to the lowest overall bills for customers. We find that customers with loads that align with peak demand and who participate in critical peak VPP programs can underpay for their contribution to utility costs and shift costs to other customers. While our assumptions about mandatory TOU and/or critical peak pricing likely impact the magnitude of the results, the results highlight the trade-offs of these tariffs and programs and the importance of tariff and program design as demand becomes more flexible and responsive.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential Impacts of Dynamic Electricity Pricing in California: Load Shape and Customer Bill Impacts Under Elastic Customer Response

The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

CSM solutions of rotating blade dynamics using integrating matrices

The dynamic behavior of flexible rotating beams continues to receive considerable research attention as it constitutes a fundamental problem in applied mechanics. Further, beams comprise parts of many rotating structures of engineering significance. A topic of particular interest at the present time involves the development of techniques for obtaining the behavior in both space and time of a rotor acted upon by a simple airload loading. Most current work on problems of this type use solution techniques based on normal modes. It is certainly true that normal modes cannot be disregarded, as knowledge of natural blade frequencies is always important. However, the present work has considered a computational structural mechanics (CSM) approach to rotor blade dynamics problems in which the physical properties of the rotor blade provide input for a direct numerical solution of the relevant boundary-and-initial-value problem. Analysis of the dynamics of a given rotor system may require solution of the governing equations over a long time interval corresponding to many revolutions of the loaded flexible blade. For this reason, most of the common techniques in computational mechanics, which treat the space-time behavior concurrently, cannot be applied to the rotor dynamics problem without a large expenditure of computational resources. By contrast, the integrating matrix technique of computational mechanics has the ability to consistently incorporate boundary conditions and 'remove' dependence on a space variable. For problems involving both space and time, this feature of the integrating matrix approach thus can generate a 'splitting' which forms the basis of an efficient CSM method for numerical solution of rotor dynamics problems.

Lakin, William D.↗

Optimizing Grid-interactive Efficient Building Designs with Stacked Value Streams

Grid-interactive efficient buildings (GEBs) are those characterized by the combination of energy efficiency and demand flexibility with smart technologies and communications to not only deliver greater affordability and comfort to buildings, but also help utilities manage grid operations and lower system costs. This paper presents an innovative techno-economic assessment framework to effectively examine different GEB design options, explore various use cases, define technically achievable benefits, and thereby assist in informed decision-making. In particular, building load flexibility, thermal storage, and battery energy storage are considered. Advanced optimal dispatch problem is formulated to maximize the stacked value streams from multiple, competing use cases, subject to the physical capabilities and operational flexibility associated with different designs and configurations. Comprehensive case studies were performed for a real-world building to evaluate the cost-effectiveness of different GEB designs and offer in-depth insights. It was found that the proposed assessment method could effectively capture the costs and benefits linked to each GEB design option. Furthermore, the study revealed that outage mitigation and demand response are the two most significant sources of benefits for GEBs.

Ma, Xu↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Research study for effects of case flexibility on bearing loads and rotor stability

Methods to evaluate the effect of casing flexibility on rotor stability and component loads were developed. Recent Rocketdyne turbomachinery was surveyed to determine typical properties and frequencies versus running speed. A small generic rotor was run with a flexible case with parametric variations in casing properties for comparison with a rotor attached to rigid supports. A program for the IBM personal computer for interactive evaluation of rotors and casings is developed. The Root locus method is extended for use in rotor dynamics for symmetrical systems by transforming all motion and coupling into a single plane and using a 90 degree criterion when plotting loci.

Fenwick, J. R.↗

Performance of an aircraft tire under cyclic braking and of a currently operational antiskid braking system

An experimental investigation was conducted to study the performance of an aircraft tire under cyclic braking conditions and to study the performance of a currently operational aircraft antiskid braking system. Dry, damp, and flooded runway surface conditions were used in the investigation. The results indicated that under cyclic braking conditions the braking and cornering-force friction coefficients may be influenced by fluctuations in the vertical load, flexibility in the wheel support, and the spring coupling between the wheel and the tire-pavement interface. The cornering capability was shown to be negligible at wheel slip ratios well below a locked-wheel skid under all test surface conditions. The maximum available brake-force friction coefficient was shown to be dependent upon the runway surface condition, upon velocity, and, for wet runways, upon tire differences. Moderate reductions in vertical load and brake system pressure did not significantly affect the overall wet-runway performance of the tire.

Tanner, J. A.↗

Customer enrollment and participation in building demand management programs: A review of key factors

Increasing the efficiency and flexibility of electricity demand is necessary for ensuring a cost-effective and reliable transition to zero-carbon electricity systems. Such demand-side management (DSM) resources have been procured by utilities for decades via energy efficiency and demand response programs; however, the key drivers of program enrollment and customer participation levels remain poorly understood — even as governments and grid planners seek to scale up the deployment of DSM assets to meet climate targets. Here we systematically review the evidence on multiple factors that may influence customer enrollment and participation in building DSM programs, focusing primarily on residential and commercial buildings. We examine the contexts in which relationships between DSM factors and outcomes are most often explored and with which methods; we also score the strength, direction, and internal consistency of each factor's reported impact on the enrollment and participation outcomes. We find that studies most commonly assess the effects of economic incentives for load flexibility on program participation levels, often using simulation-based methods in lieu of measured data. Few studies focus on program enrollment outcomes or regulatory drivers of either enrollment or participation, and gaps are also evident in the coverage of emerging DSM opportunities like load electrification. Removal of structural barriers (e.g., the lack of controls infrastructure) and the use of third party services (e.g., load aggregators) are the factors with the largest positive impacts on DSM outcomes, but no single factor emerges as clearly most impactful. For a given factor, the range of reported impacts typically varies widely across the relevant studies reviewed. Our findings provide a snapshot of the state of knowledge about building DSM and customer decision-making, and they expose key gaps in understanding that must be filled if building DSM is to expand as a critical resource for operating clean power grids.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗