Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS 2 devices

Here we report on the depinning of nearly commensurate charge-density waves in 1T-TaS 2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS 2 is not accompanied by an observable abrupt increase in electric current—in striking contrast to depinning in the conventional charge-density-wave materials with quasi-1D crystal structure. We explained it by the fact that the current density from the charge-density waves in the 1T-TaS 2 devices is orders of magnitude smaller than the current density of the free carriers available in the discommensuration network surrounding the commensurate charge-density wave islands. The depinning fields in 1T-TaS 2 thin-film devices are several orders of magnitude larger than those in quasi-1D van der Waals materials. Obtained results are important for the proposed applications of the charge-density wave devices in electronics.

2D materials↗

Structural magnetic glassiness in the spin ice Dy 2 Ti 2 O 7

The origin and nature of glassy dynamics presents one of the central enigmas of condensed-matter physics across a broad range of systems ranging from window glass to spin glasses. The spin-ice compound Dy 2 Ti 2 O 7 , which is perhaps best known as hosting a three-dimensional Coulomb spin liquid with magnetically charged monopole excitations, also falls out of equilibrium at low temperature. How and why it does so remains an open question. Based on an analysis of low-temperature diffuse neutron-scattering experiments employing different cooling protocols alongside recent magnetic noise studies, combined with extensive numerical modeling, we argue that upon cooling, the spins freeze into what may be termed a “structural magnetic glass,” without an a priori need for chemical or structural disorder. Specifically, our model indicates the presence of frustration on two levels, first producing a near-degenerate constrained manifold inside which phase ordering kinetics is in turn frustrated. A remarkable feature is that monopoles act as sole annealers of the spin network and their pathways and history encode the development of glass dynamics, allowing the glass formation to be visualized. Our results suggest that spin ice Dy 2 Ti 2 O 7 provides one prototype of magnetic glass formation specifically and a setting for the study of kinetically constrained systems more generally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Percolation and nanosecond fluctuators in V 2 O 3 films within the metal–insulator transition

Vanadium sesquioxide (V 2 O 3 ) exhibits a metal–insulator transition (MIT) at 160 K between a low temperature, monoclinic, antiferromagnetic Mott insulator and a high temperature, rhombohedral, paramagnetic, metallic phase. In thin films, a percolative transition takes place over a finite temperature range of phase coexistence. We study the fluctuating dynamics of this percolative MIT by measuring voltage noise spectra at both low frequencies (up to 100 kHz) and radio frequencies (between 10 MHz and 1 GHz). Noise intensity quadratic in bias is observed in the MIT region, as expected for resistive fluctuations probed nonperturbatively by the current. The low frequency noise resembles flicker-type 1/f β noise, often taking on the form of Lorentzian noise dominated by a small number of fluctuators as the volume fraction of the insulating phase dominates. Radio frequency noise intensity also quadratic in the bias current allows the identification of resistance fluctuations with lifetimes below 1 ns, approaching timescales seen in non-equilibrium pump–probe studies of the transition. We find quantitative consistency with a model for fluctuations in the percolative fraction. The thermodynamics of the MIT suggests that dominant fluctuations are ones that alter small volumes affecting the connectivity of domain boundaries. This noise serves as a sensitive and nonperturbative probe for the dynamics of switching phenomena in this system.

36 MATERIALS SCIENCE↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Implementing microwave impedance microscopy in a dilution refrigerator

We report the implementation of a dilution refrigerator-based scanning microwave impedance microscope with a base temperature of ∼100 mK. The vibration noise of our apparatus with tuning-fork feedback control is as low as 1 nm. Using this setup, we have demonstrated the imaging of quantum anomalous Hall states in magnetically (Cr and V) doped (Bi, Sb)2Te3 thin films grown on mica substrates. Both the conductive edge modes and topological phase transitions near the coercive fields of Cr- and V-doped layers are visualized in the field-dependent results. Our study establishes the experimental platform for investigating nanoscale quantum phenomena at ultralow temperatures.

Instruments & Instrumentation↗

Radiatively cooled quantum microwave amplifiers

Superconducting microwave amplifiers are essential for sensitive signal readout in superconducting quantum processors. Typically based on Josephson junctions, these amplifiers require operation at milli-Kelvin temperatures to achieve quantum-limited performance. Here, we demonstrate a quantum microwave amplifier that employs radiative cooling to operate at elevated temperatures and maintain near quantum-limited added noise. This kinetic-inductance-based parametric amplifier, patterned from a single layer of relatively high-Tc NbN thin film, maintains a high gain and meanwhile enables low added noise of 1.3 quanta when operated at 1.5 K. Remarkably, this represents only a 0.2 quanta increase compared to the performance at a base temperature of 0.1 K. Based on our findings, we also discuss the practicality of such an operating scheme for various quantum applications. By uplifting the parametric amplifiers from the mixing chamber without compromising readout efficiency, this work represents an important step toward more scalable microwave quantum technologies.

Physics↗

Injection locking and coupling dynamics in superconducting nanowire-based cryogenic oscillators

Oscillators designed to function at cryogenic temperatures play a critical role in superconducting electronics and quantum computing by providing stable, low-noise signals with minimal energy loss. Here, in this work, we present a comprehensive numerical study of injection locking and mutual coupling dynamics in superconducting nanowire (ScNW)-based cryogenic oscillators. Using the design space of a standalone ScNW-based oscillator, we investigate two critical mechanisms that govern frequency synchronization and signal coordination in cryogenic computing architectures: (1) injection locking induced by an external AC signal with a frequency near the oscillator's natural frequency, and (2) the mutual coupling dynamics between two ScNW oscillators under varying coupling strengths. We identify key design parameters—such as shunt resistance, nanowire inductance, and coupling strength—that govern the locking range. Additionally, we examine how the amplitude of the injected signal affects the amplitude of the locked oscillation, offering valuable insights for power-aware oscillator synchronization. Furthermore, we analyze mutual synchronization between coupled ScNW oscillators using capacitive and resistive coupling elements. Our results reveal that the phase difference between oscillators can be controlled by tuning the coupling strength, enabling programmable phase-encoded information processing. These findings could enable building ScNW-based oscillatory neural networks, synchronized cryogenic logic blocks, and on-chip cryogenic resonator arrays.

Artificial neural networks↗

Initial Results on a New Light-Duty 2.7-L Opposed-Piston Gasoline Compression Ignition Multi-Cylinder Engine

Abstract Gasoline compression ignition (GCI) is a cost-effective approach to achieving diesel-like efficiencies with low emissions. The fundamental architecture of the two-stroke Achates Power Opposed-Piston (OP) Engine enables GCI by decoupling piston motion from cylinder scavenging, allowing for flexible and independent control of cylinder residual fraction and temperature leading to improved low-load combustion. In addition, the high peak cylinder pressure and noise challenges at high-load operation are mitigated by the lower brake mean effective pressure (BMEP) operation and faster heat release for the same pressure rise rate of the OP Engine. These advantages further solidify the performance benefits of the OP Engine and demonstrate the near-term feasibility of advanced combustion technologies, enabled by the opposed-piston architecture. This paper presents initial results from steady-state testing on a brand new 2.7-L OP GCI multi-cylinder engine (MCE) designed for light-duty truck applications. Successful GCI operation calls for a high compression ratio (CR), leading to higher combustion stability at low loads, higher efficiencies, and lower cycle HC + NOX emissions. Initial results show a cycle average brake thermal efficiency (BTE) of 31.7%, which is already greater than 11% conventional engines, after only ten weeks of testing. Emissions results suggest that Tier 3 Bin 160 levels can be achieved using a traditional diesel after-treatment system. Combustion noise was well controlled at or below the United States Council for Automotive Research limits. In addition, initial results on catalyst light-off mode with GCI are also presented.

Energy & Fuels↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Mesoscale system feedback-induced dissipation and noise suppression

A high-gain and low-noise negative feedback control (“feedback control”) system can detect charge transfer in quantum systems at room temperatures. The feedback control system can attenuate dissipative coupling between a quantum system and its thermodynamic environment. The feedback control system can be integrated with standard commercial voltage-impedance measurement system, for example, a potentiostat. In one aspect, the feedback control system includes a plurality of electrodes that are configured to electrically couple to a sample, and a feedback mechanism coupled to a first electrode of the plurality of electrodes. The feedback mechanism is configured to detect a potential associated with the sample via the first electrode. The feedback mechanism provides a feedback signal to the sample via a second electrode of the plurality of electrodes, the feedback signal is configured to provide excitation control of the sample at a third electrode of the plurality of electrode.

Gupta, Chaitanya↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

The ProtoDUNE-SP LArTPC electronics production, commissioning, and performance

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low electronic noise pre-amplifier and digitization ASICs integrated into Front End Motherboards (FEMBs) operating at cryogenic temperature within the cryostat. The large number of electronics channels and high performance specifications required a large-scale production electronics quality control effort, careful installation into Anode Plane Assemblies (APAs), and rigorous detector commissioning. This successful collaboration-wide effort achieved a working LArTPC electronics channel percentage of 99.7% (15,318 of 15,360 channels in total), whose operating performance exceeded expectations. We summarize the ProtoDUNE-SP cold electronics design and quality control, installation, and commissioning efforts that enabled this excellent electronics performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact and mitigation of polarized extragalactic foregrounds on Bayesian cosmic microwave background lensing

Future low-noise cosmic microwave background (CMB) lensing measurements from e.g., CMB-S4 will be polarization dominated, rather than temperature dominated. In this new regime, statistically optimal lensing reconstructions outperform the standard quadratic estimator, but their sensitivity to extragalactic polarized foregrounds has not been quantified. Using realistic simulations of polarized radio and infrared point sources, we show for the first time that optimal Bayesian lensing from a CMB-S4-like experiment is insensitive to the expected level of polarized extragalactic foregrounds after masking, as long as an accurate foreground power spectrum is included in the analysis. For more futuristic experiments where these foregrounds could cause a detectable bias, we propose a new method to jointly fit for lensing and the Poisson foregrounds, generalizing the bias hardening from the standard quadratic estimator to Bayesian lensing.

cosmic microwave background↗

Shot-noise-induced lower temperature limit of the nonneutral plasma parallel temperature diagnostic

Abstract We develop a new algorithm to estimate the temperature of a nonneutral plasma in a Penning-Malmberg trap. The algorithm analyzes data obtained by slowly lowering a voltage that confines one end of the plasma and collecting escaping charges, and is a maximum likelihood estimator based on a physically-motivated model of the escape protocol presented in (Beck in Measurement of the magnetic and temperature dependence of the electron-electron anisotropic temperature relaxation rate. PhD thesis, 1990). Significantly, our algorithm may be used on single-count data, allowing for improved fits with low numbers of escaping electrons. This is important for low-temperature plasmas such as those used in antihydrogen trapping. We perform a Monte Carlo simulation of our algorithm, and assess its robustness to intrinsic shot noise and external noise. The assumptions in this paper allow for a lower bound for measurable plasma temperatures of approximately $3\,\mathrm{K}$ 3 K for plasmas of length $1\,\mathrm{cm}$ 1 cm , with approximately 100 particle counts needed for an accuracy of $\pm 10 \%$ ± 10 % .

Zhong, Adrianne (ORCID:0000000162618736)↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background↗