Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effects of diffusion and mass flows on C IV and Si IV lines formed in the solar atmosphere

A model for the transition region is derived from an initial interpretation of EUV observations, assuming ionization equilibrium and constant elemental abundance with height. The effects of diffusion and mass flows are then included in the initial model and the emergent profiles of several C IV and Si IV lines are computed. It is found that diffusion and mass flows have a strong effect on both the emergent intensity and spectral shape of these lines. Diffusion acts to deplete the transition region of heavy ions to an extent which depends on the detailed temperature and density structure. The net effect is a weighting of the coronal emission relative to that in the transition. On the basis of the results, it is suggested that the downflows observed in the network in lines of C IV and Si IV could be due to gravitational settling of the ions following their injection, via diffusion, into the corona from spicules. When flows are superposed on the basic diffusion model, the rapid change in elemental abundance characteristic of the model is virtually eliminated and the coronal contribution to the emission in C IV and Si IV lines becomes negligible relative to that in the transition region. Flows have a strong effect on the computed line intensities and introduce large asymmetries into the line shapes.

Roussel-Dupre, R.↗

Surface Time-Variable Gravity Signals and Possible Sources Including Core Mass Flow

Over two decades of geodetic satellite-laser-ranging (SLR) data show that the variation of the Earth's oblateness parameter J2 has a clear seasonal signal of amplitude of about 3e-10 and a secular decrease of about -2.8e-11/year, superimposed on some interesting interannual fluctuations. Physically, any change in mass distribution or/inside the Earth will be reflected in the time-variable gravity signal obtained outside the Earth, according to Newton s gravitational law. Therefore, such signal contains contributions from all geophysical sources that redistribute mass, on all temporal and spatial scales, including those from the core. Besides Earth rotation and geomagnetic field variations, the time-variable gravity also contains information linking Earth surface observations with internal core dynamical processes. The time scales of the gravity signal are critical in helping differentiate different contributions. The atmosphere and hydrosphere are responsible for the seasonal and much of the interannual and intraseasoanl fluctuations, while the secular trend is due mainly to the post-glacial rebound but possibly core mass flow. To estimate the latter effect, we use our MoSST (Modular, Scalable, Self-consistent, Three-dimensional) core dynamics model to forward simulate the core flow, and density variation due to the core convection. Our results suggest that, when upward continued to the surface, the J2 component of the core mass redistribution can reach an overall amplitude of e-11/year, approaching the SLR detectability and significant in geophysical terms. We also find a general westward drift of the mass flow, with a speed comparable to that of the geomagnetic westward drift.

Chao, Benjamin F.↗

Small Scale Mass Flow Plug Calibration

A simple control volume model has been developed to calculate the discharge coefficient through a mass flow plug (MFP) and validated with a calibration experiment. The maximum error of the model in the operating region of the MFP is 0.54%. The model uses the MFP geometry and operating pressure and temperature to couple continuity, momentum, energy, an equation of state, and wall shear. Effects of boundary layer growth and the reduction in cross-sectional flow area are calculated using an in- integral method. A CFD calibration is shown to be of lower accuracy with a maximum error of 1.35%, and slower by a factor of 100. Effects of total pressure distortion are taken into account in the experiment. Distortion creates a loss in flow rate and can be characterized by two different distortion descriptors.

mass-flow measurements↗

Mass flow requirements for LFC wing design

The problem of determining optimum suction mass flow requirements for LFC wings is addressed. Some previous methods for predicting the extent of laminar flow over swept wings with suction are briefly reviewed. These range from the purely empirical to those utilizing tabulated linear stability computations. The present method is described. This method solves the linear, incompressible stability equations by spectral techniques. The maximum temporal amplification of boundary layer crossflow and 2-D disturbances is determined for waves of a given frequency. Group velocities are used to integrate these amplification rates along the wing to yield the logarithmic amplitude ratio or 'N factor' of the disturbance. The 'N factor' calibration of a computer code utilizing this method is described, using experimentally determined transition data. The method is shown to be as consistent as previously used 'fixed wavelength' methods.

Srokowski, A. J.↗

Acquisition and correlation of cryogenic nitrogen mass flow data through a multiple orifice Joule-Thomson device

Liquid nitrogen mass flow rate, pressure drop, and temperature drop data were obtained for a series of multiple orifice Joule-Thomson devices, known as Visco Jets, over a wide range of flow resistance. The test rig used to acquire the data was designed to minimize heat transfer so that fluid expansion through the Visco Jets would be isenthalpic. The data include a range of fluid inlet pressures from 30 to 60 psia, fluid inlet temperatures from 118 to 164 R, outlet pressures from 2.8 to 55.8 psia, outlet temperatures from 117 to 162 R and flow rate from 0.04 to 4.0 lbm/hr of nitrogen. A flow rate equation supplied by the manufacturer was found to accurately predict single-phase (noncavitating) liquid nitrogen flow through the Visco Jets. For cavitating flow, the manufacturer's equation was found to be inaccurate. Greatly improved results were achieved with a modified version of the single-phase equation. The modification consists of a multiplication factor to the manufacturer's equation equal to one minus the downstream quality on an isenthalpic expansion of the fluid across the Visco Jet. For a range of flow resistances represented by Visco Jet Lohm ratings between 17,600 and 80,000, 100 percent of the single-phase data and 85 percent of the two-phase data fall within + or - 10 percent of predicted values.

Papell, S. Stephen↗

Performance of Thermal Mass Flow Meters in a Variable Gravitational Environment

The performance of five thermal mass flow meters, MKS Instruments 179A and 258C, Unit Instruments UFM-8100, Sierra Instruments 830L, and Hastings Instruments HFM-200, were tested on the KC-135 Reduced Gravity Aircraft in orthogonal, coparallel, and counterparallel orientations relative to gravity. Data was taken throughout the parabolic trajectory where the g-level varied from 0.01 to 1.8 times normal gravity. Each meter was calibrated in normal gravity in the orthogonal position prior to flight followed by ground testing at seven different flow conditions to establish a baseline operation. During the tests, the actual flow rate was measured independently using choked-flow orifices. Gravitational acceleration and attitude had a unique effect on the performance of each meter. All meters operated within acceptable limits at all gravity levels in the calibrated orthogonal position. However, when operated in other orientations, the deviations from the reference flow became substantial for several of the flow meters. Data analysis indicated that the greatest source of error was the effect of orientation, followed by the gravity level. This work emphasized that when operating thermal flow meters in a variable gravity environment, it is critical to orient the meter in the same direction relative to gravity in which it was calibrated. Unfortunately, there was no test in normal gravity that could predict the performance of a meter in reduced gravity. When operating in reduced gravity, all meters indicated within 5 percent of the full scale reading at all flow conditions and orientations.

Brooker, John E.↗

Acton mass flow system applied to PFBC feed

Dense phase pneumatic conveying and the Acton Mass Flow concept are defined with emphasis on the specific advantages to the coal and dolomite feed to the Pressurized Fluidized Bed Combustor. The transport and feed functions are explored with a comparison of designing the process for a combined function or for individual functions. The equipment required to accomplish these functions is described together with a typical example of sizing and air or gas requirements. A general outline of the control system required to obtain a uniform feed rate is provided. The condition of the coal and dolomite and conveying gas as required to obtain reliable transport and feed will be discussed.

Homburg, E.↗

Mass-Flow-Meter Leak-Testing System

Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

Sorensen, Eric B.↗

The automation of an inlet mass flow control system

The automation of a closed-loop computer controlled system for the inlet mass flow system (IMFS) developed for a wind tunnel facility at Langley Research Center is presented. This new PC based control system is intended to replace the manual control system presently in use in order to fully automate the plug positioning of the IMFS during wind tunnel testing. Provision is also made for communication between the PC and a host-computer in order to allow total animation of the plug positioning and data acquisition during the complete sequence of predetermined plug locations. As extensive running time is programmed for the IMFS, this new automated system will save both manpower and tunnel running time.

Supplee, Frank↗

Mass flow meter using the triboelectric effect for measurement in cryogenics

The use of triboelectric charge to measure the mass flow rate of cryogens for the Space Shuttle Main Engine was investigated. Cross correlation of the triboelectric charge signals was used to determine the transit time of the cryogen between two sensor locations in a .75-in tube. The ring electrode sensors were mounted in a removable spool piece. Three spool pieces were constructed for delivery, each with a different design. One set of electronics for implementation of the cross correlation and flow calculation was constructed for delivery. Tests were made using a laboratory flow loop using liquid freon and transformer oil. The measured flow precision was 1 percent and the response was linear. The natural frequency distribution of the triboelectric signal was approximately 1/f. The sensor electrodes should have an axial length less than approximately one/tenth pipe diameter. The electrode spacing should be less than approximately one pipe diameter. Tests using liquid nitrogen demonstrated poor tribo-signal to noise ratio. Most of the noise was microphonic and common to both electrode systems. The common noise rejection facility of the correlator was successful in compensating for this noise but the signal was too small to enable reliable demonstration of the technique in liquid nitrogen.

Bernatowicz, Henry↗

Numerical Calibration of Mass Flow Plug for Inlet Testing

A simple control volume model has been developed to calculate the discharge coefficient through a mass flow plug (MFP) and validated with a calibration experiment. The maximum error of the model within the operating region of the MFP is 0.54%. The control volume analysis developed work is comprised of a sequence of flow calculations through the MFP. The model uses the MFP geometry and operating pressure and temperature to couple continuity, momentum, energy, an equation of state, and wall shear. The discharge coefficient calculation also includes the effects of boundary layer growth, including the reduction in cross-sectional flow area as characterized by the boundary layer displacement thickness. The last calculation in the sequence uses an integral method to calculate the growth of the boundary layer, from which the displacement thickness is then determined. The result of these successive calculations is an accurate one-dimension model of the velocity, pressure, and temperature through the MFP. For comparison, a computational fluid dynamic (CFD) calibration is shown, which when compared to the presented numerical model, had a lower accuracy with a maximum error of 1.35% in addition to being slower by a factor of 100."

Flow Measurement↗

IUE spectroscopy of U Cephei during the mass flow outburst of 1986 June

The interacting Algol-type binary U Cep underwent another of its irregularly occurring transient high-mass flow events during June 1986. For the first time, high-resolution ultraviolet spectroscopy of U Cep during such an event was possible. High-resolution spectra in the far-ultraviolet and near-ultraviolet were obtained with IUE. These spectra show that the ultraviolet continuum decreased by factors of 1.2 to 3.0 during the greatest activity. In addition, one or more narrow absorption components with radial velocities as high as -500 km/s appeared in association with a number of C, Si, Al, Fe, Zn, and Mg lines. The Mg II doublet developed a flat-bottomed appearance with a residual intensity of about 0.31 and a width of at least 800 km/s. These phenomena are interpreted in terms of high-velocity gas streams, mass loss from the system, and the formation of an optically thick equatorial bulge around the B star.

Mccluskey, George E., Jr.↗

Channel size influence on the heat flux density at zero net mass flow in the non-linear transport regime between 1.2 and 2.1 K

Porous media and narrow ducts of simple shape at zero net mass flow (ZNMF) are used to investigate the influence of pore size on the entropy/heat convection rate at ZNMF. The study is relevant to the development of specific types of phase separators. Previous work on heat transport by convection is extended to porous media without mass loss. The experimental results show the influence of pore size on heat flux for permeabilities between 10 to the -8th and 10 to the -6th sq cm. ZNMF plug data are found to be similar to results obtained for vapor liquid phase separation.

Frederking, T. H. K.↗