Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

Testing of Materials and Coatings at up to 1150°C and 300 bar for use in Oxy-Combustion Turbine

Various materials that may be used in a supercritical carbon dioxide (sCO2) oxy-fuel turbine in the 150-300 MWe size range are being evaluated in various environments of interest. The inlet of the turbine must be capable of 1,150 °C at 300 bar and the exhaust temperature is expected to be within the 725-775 °C range. The design requirements are pushing the known limits of high temperature materials. Little is known about the oxidation of the metallic alloys considered for turbine nozzles and blades or about the resilience of thermal management solutions, such as thermal barrier coatings (TBC), required to accommodate these high temperatures. The combinations of high temperature resistant materials and coatings must be tested in sCO2 to evaluate their reliability in an oxy-fuel turbine environment. A total of 13 alloys were chosen to be tested. They included bare samples, with nano deposited MCrAlY bond coat only, or with the addition of a TBC. A unique test facility was developed to expose those materials in sCO2 at up to 300 bar and 1150 °C for up to 5,000 hours. This was accomplished by placing an induction heater inside an autoclave to achieve those high temperature locally while the pressurized vessel is cooled externally. The specimens are weighed before and after exposure to determine the oxidation rate. The integrity, morphology, and composition of some of the coatings and thermally grown oxide will be investigated by scanning electron microscopy (SEM). This paper presents the up-to-date results of the testing coated and uncoated superalloys in sCO2 at up to 1150 °C and up to 300 bar performed at Southwest Research Institute.

Bocher, Florent↗

Initial development of an in-situ, passive material surveillance test article for monitoring high temperature reactor structural components

This report describes the development of a family of passively-actuated surveillance test articles, suitable for use in an in-situ reactor test program monitoring the degradation in structural material properties caused by the reactor environment. The test articles apply creep-fatigue-type cyclic load to a test section driven by changes in the reactor coolant temperature converted to mechanical force by differential thermal expansion. The report describes three types of test articles, all of which apply the load to a 316H test section using Alloy 617 as the driver material. The three types of specimens each serve a unique purpose: (1) initial proof-of-concept, (2) validation of the models used to size the specimens to achieve a given strain range, and (3) demonstration that the articles can be miniaturized for use in an actual operating reactor. In addition to the specimen design, fabrication, and testing, this report describes the outline of two types of in-situ monitoring programs, using the test article. Monitoring programs such as these could be a critical component in gaining regulator acceptance for Molten Salt Reactor (MSR) designs using structural materials for which there is little long-term experimental environmental testing or operating experience available for calibrating the component structural design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accelerated computation of lattice thermal conductivity using neural network interatomic potentials

We report with the development of the density functional theory (DFT) and ever-increasing computational capacity, an accurate prediction of lattice thermal conductivity based on the Boltzmann transport theory becomes computationally feasible, contributing to a fundamental understanding of thermal conductivity as well as a choice of the optimal materials for specific applications. However, steep costs in evaluating third-order force constants limit the theoretical investigation to crystals with high symmetry and few atoms in the unit cell. Currently, machine learning potentials are garnering attention as a computationally efficient high-fidelity model of DFT, and several studies have demonstrated that the lattice thermal conductivity could be computed accurately via the machine learning potentials. However, test materials were mostly crystals with high symmetries, and the applicability of machine learning potentials to a wide range of materials has yet to be demonstrated. Furthermore, establishing a standard training set that provides consistent accuracy and computational efficiencies across a wide range of materials would be useful. To address these issues, herein we compute lattice thermal conductivities at 300 K using neural network interatomic potentials. As test materials, we select 25 materials with diverse symmetries and a wide range of lattice thermal conductivities between 10 -1 and 10 3 Wm -1 K -1 . Among various choices of training sets, we find that molecular dynamics trajectories at 50–700 K consistently provide results at par with DFT for the test materials. In contrast to pure DFT approaches, the computational cost in the present approach is uniform over the test materials, yielding a speed gain of 2–10 folds. When a smaller reduced training set is used, the relative efficiency increases by up to ~50 folds without sacrificing accuracy significantly. The current work will broaden the application scope of machine learning potentials by establishing a robust framework for accurately computing lattice thermal conductivity with machine learning potentials.

36 MATERIALS SCIENCE↗

Evaluating Non-Fluoropolymer-Based Co-Extruded Backsheets Using Combined-Accelerated Stress Testing and Materials Forensics

Co-extruded, non-fluoropolymer backsheet films for photovoltaic (PV) modules have gained popularity in recent years based on their cost competitiveness. However, their viability has been thrown into question as a result of widespread, early-life field-failures of some materials, particularly the polyamide (PA)-based “AAA” backsheet product. Failure to detect weaknesses in those earlier products could be due, in part, to insufficient quality testing practices. New testing protocols have recently been developed to better evaluate such materials. Here we show the testing results for a non-fluoropolymer, co-extruded PA-based backsheet film, which demonstrates greater durability than AAA and some commercial fluoropolymers. Using material characterization techniques including Fourier-transform infrared spectroscopy (FTIR), wide-angle x-ray scattering (WAXS), differential scanning calorimetry (DSC), X-ray photoelectron spectroscopy (XPS), elongation-to-break (ETB), and optical microscopy we perform a comprehensive failure analysis to better understand the materials weaknesses. This analysis can ultimately inform how best to improve the material and extend its lifetime. This work serves as a demonstration that some materials should not be discounted due to a single poorly designed product and that more appropriate qualification testing with subsequent materials analysis can be used to develop better materials.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Elucidating the Impact of Flow on Material-Sensitive Critical Heat Flux and Boiling Heat Transfer Coefficients: An Experimental Study with Various Materials

In this work, steady-state internal flow boiling critical heat flux (CHF) experiments were carried out at 10°C inlet subcooling and atmospheric pressure (84 kPa at an altitude of about 5300 feet) with mass flux ranging from 200 to 2,000 kg/m 2 -s on seven tube materials, including the accident-tolerant fuel cladding candidate FeCrAl (C26M) alloy. At a relatively low flow rate, the sensitivity of CHF to different materials was appreciable (the average difference among the tested materials was 19% at 200 kg/m 2 -s). As the absolute CHF differences stayed constant for higher flow rates, the increased flow rate led to reduced relative CHF differences among the tested materials (average relative difference of 15% at 1,000 kg/m 2 -s). FeCrAl alloy claddings that were oxidized under simulated Light Water Reactor (LWR) conditions yielded CHF comparable to as-received FeCrAl alloy cladding, with less than 1.8% difference. Experimental CHF results imply marginal material sensitivity impacts on the departure from nucleate boiling ratio in steady-state nuclear reactor cores. Yet, for accident progression analysis, material sensitivity may hold importance, as boiling behavior variation at low mass flux is appreciable. Macroscopic material parameters (surface wettability, surface roughness, and thermal properties) do not provide a suitable explanation for observed material-sensitive CHFs. Yet, surface roughness and thermal effusivity revealed power and linear relations, respectively, to the nucleate boiling heat transfer coefficients at low mass flux. At high mass flux, material sensitivity on nucleate boiling heat transfer significantly decreased due to the increased shear stress on boiling surface overwhelming material-related boiling implications.

36 MATERIALS SCIENCE↗

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)↗

Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs

The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

Assessing the viability of a new subsize tensile specimen geometry for evaluation of structural nuclear and additively manufactured materials

The use of subsize specimens in nuclear materials testing has been a subject of ongoing interest due to radiation safety concerns and resource conservation needs. It is also of interest in additive manufacturing (AM), also known as 3D-printing, as subsize specimens can more accurately represent the behavior of the small, intricate geometries often produced using AM. A novel, extremely small geometry, called the Subsize Teeny (SST) was recently developed and is of interest for implementation. Given its extraordinarily small size and the complexities associated with subsize specimen testing, adequate vetting of this geometry is necessary to ensure data quality. Here, a variety of unirradiated nuclear structural materials were tested in the SST geometry and compared against the well-established SSJ3 geometry. In addition, two case studies implementing the SST as a screening geometry for AM materials were also conducted. The question of SST viability was found to be highly nuanced and will often be dependent on the context or application in question. It was determined, however, that the SST is a largely invalid geometry for exceptionally coarse-grained materials or in cases where the physical defect volume equals or exceeds 0.1 % or where the specimen machining parameters result in significant surface alterations. On the other hand, it was determined that the SST may be employed with confidence if the test material is nearly or totally free of physical defects, isotropic, demonstrates homogeneous plastic deformation, and possesses a fine-grained, nearly or totally homogeneous microstructure with at least twelve slip systems.

Additive manufacturing↗

Measurement and Reporting Guidelines for Solar Mirror Aging Tests Using Xenon Arc Lamp Exposure (XALE)

This technical report provides a guideline for accelerated aging tests on solar reflectors. Solar reflectors must have a high durability, with goal lifespans reaching 30 years. To test and develop state-of-the-art solar reflectors, relevant durability tests must be conducted. Existing guidelines for materials testing include isothermal testing, humidity testing, corrosion, etc., but many tests do not specify to include solar irradiance or address its relevance to solar reflector durability. The guideline focuses on test design and reporting guidelines for using Xenon Arc Lamp Exposure (XALE). The XALE environmental chambers can subject samples to a combination of relevant environmental factors including concentrated solar irradiance, heat, humidity, and weathering cycles. The guideline is meant to provide information on developing relevant test conditions, exposure times, reflectance characterization procedures, and data reporting.

14 SOLAR ENERGY↗

Thermal-Mechanical Elastic-Plastic and Ductile Failure Model Calibrations for 304L Stainless Steel Alloy

Numerical simulations of metallic structures undergoing rapid loading into the plastic range require material models that accurately represent the response. In general, the material response can be seen as having four interrelated parts: the baseline response under slow loading, the effect of strain rate, the conversion of plastic work into heat and the effect of temperature. In essence, the material behaves in a thermal-mechanical manner if the loading is fast enough so when heat is generated by plastic deformation it raises the temperature and therefore influences the mechanical response. In these cases, appropriate models that can capture the aspects listed above are necessary. The material of interest here is 304L stainless steel, and the objective of this work is to calibrate thermal-mechanical models: one for the constitutive behavior and another for failure. The work was accomplished by first designing and conducting a material test program to provide data for the calibration of the models. The test program included uniaxial tension tests conducted at room temperature, 150 and 300 C and at strain rates between 10 –4 and 10 3 1/s. It also included notched tension and shear-dominated compression hat tests specifically designed to calibrate the failure model. All test specimens were extracted from a single piece of plate to maintain consistency. The constitutive model adopted was a modular $J_2$ plasticity model with isotropic hardening that included rate and temperature dependence. A criterion for failure initiation based on a critical value of equivalent plastic strain fitted the failure data appropriately and was adopted. Possible ranges of the values of the parameters of the models were determined partially on historical data from calibrations of the same alloy from other lots and are given here. The calibration of the parameters of the models were based on finite element simulations of the various material tests using relatively ne meshes and hexahedral elements. When using the model in structural finite element calculations, however, element formulations and sizes different from those in the calibration are likely to be used. A brief investigation demonstrated that the failure initiation predictions can be particularly sensitive to the element selection and provided an initial guide to compensate for the effect of element size in a specific example.

36 MATERIALS SCIENCE↗