Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurable multifunctions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Strain Sensitivity in Single Walled Carbon Nanotubes for Multifunctional Materials

Single walled carbon nanotubes represent the future of structural aerospace vehicle systems due to their unparalleled strength characteristics and demonstrated multifunctionality. This multifunctionality rises from the CNT's unique capabilities for both metallic and semiconducting electron transport, electron spin polarizability, and band gap modulation under strain. By incorporating the use of electric field alignment and various lithography techniques, a single wall carbon nanotube (SWNT) test bed for measurement of conductivity/strain relationships has been developed. Nanotubes are deposited at specified locations through dielectrophoresis. The circuit is designed such that the central, current carrying section of the nanotube is exposed to enable atomic force microscopy and manipulation in situ while the transport properties of the junction are monitored. By applying this methodology to sensor development a flexible single wall carbon nanotube (SWNT) based strain sensitive device has been developed. Studies of tensile testing of the flexible SWNT device vs conductivity are also presented, demonstrating the feasibility of using single walled HiPCO (high-pressure carbon monoxide) carbon nanotubes as strain sensing agents in a multi-functional materials system.

Heath, D. M.↗

LADAR vision technology for automated rendezvous and capture

LADAR Vision Technology at Autonomous Technologies Corporation consists of two sensor/processing technology elements: high performance long range multifunction coherent Doppler laser radar (LADAR) technology; and short range integrated CCD camera with direct detection laser ranging sensors. Algorithms and specific signal processing implementations have been simulated for both sensor/processing approaches to position and attitude tracking applicable to AR&C. Experimental data supporting certain sensor measurement accuracies have been generated.

Frey, Randy W.↗

Characterizing SWCNT Dispersion in Polymer Composites

The new wave of single wall carbon nanotube (SWCNT) infused composites will yield structurally sound multifunctional nanomaterials. The SWCNT network requires thorough dispersion within the polymer matrix in order to maximize the benefits of the nanomaterial. However, before any nanomaterials can be used in aerospace applications a means of quality assurance and quality control must be certified. Quality control certification requires a means of quantification, however, the measurement protocol mandates a method of seeing the dispersion first. We describe here the new tools that we have developed and implemented to first be able to see carbon nanotubes in polymers and second to measure or quantify the dispersion of the nanotubes.

Lillehei, Peter T.↗

Aerospace Sensor Systems: From Sensor Development To Vehicle Application

This paper presents an overview of years of sensor system development and application for aerospace systems. The emphasis of this work is on developing advanced capabilities for measurement and control of aeropropulsion and crew vehicle systems as well as monitoring the safety of those systems. Specific areas of work include chemical species sensors, thin film thermocouples and strain gages, heat flux gages, fuel gages, SiC based electronic devices and sensors, space qualified electronics, and MicroElectroMechanical Systems (MEMS) as well as integrated and multifunctional sensor systems. Each sensor type has its own technical challenges related to integration and reliability in a given application. The general approach has been to develop base sensor technology using microfabrication techniques, integrate sensors with "smart" hardware and software, and demonstrate those systems in a range of aerospace applications. Descriptions of the sensor elements, their integration into sensors systems, and examples of sensor system applications will be discussed. Finally, suggestions related to the future of sensor technology will be given. It is concluded that smart micro/nano sensor technology can revolutionize aerospace applications, but significant challenges exist in maturing the technology and demonstrating its value in real-life applications.

Hunter, Gary W.↗

Wireless Measurement of Contact and Motion Between Contact Surfaces

This method uses a magnetic-field- response contact sensor that is designed to identify surface contact and motion between contact locations. The sensor has three components: (1) a capacitor-inductor circuit with two sets of electrical contact pads, (2) a capacitor with a set of electrical contact pads, and (3) an inductor with a set of electrical contact pads. A unique feature of this sensor is that it is inherently multifunctional. Information can be derived from analyzing such sensor response attributes as amplitude, frequency, and bandwidth. A change in one attribute can be due to a change in a physical property of a system. A change in another attribute can be due to another physical property, which has no relationship to the first one.

Woodard, Stanley E.↗

24-71 GHz PCB Array for 5G ISM

Millimeter-wave 5G mobile architectures need to consolidate disparate frequency bands into a single, multifunctional array. Existing arrays are either narrow-band, prohibitively expensive or cannot be scaled to these frequencies. In this paper, we present the first ultra-wideband millimeter wave array to operate across six 5G and ISM bands spanning 24-71 GHz. Importantly, the array is realized using low-cost PCB. The paper presents the design and optimized layout, and discusses fabrication and measurements.

5G and ISM↗

(Preliminary) Effects of Ball Milling Zeolite Powders for Use in Additively Manufactured Solid Sorbents

Zeolite 13X is favorable to be used as an adsorbent in carbon dioxide (CO2) removal from the spacecraft cabin air. Reducing the size of the zeolite particles and particle size distribution is thought to increase the capacity of CO2 adsorption of the zeolite 13X powder, and potentially increase its manufacturability as a paste for additive manufacturing or slip casting. This paper will go into detail on the process of using ball milling in order to reduce particle size and particle size distribution of commercial zeolite 13X powder, as well as to characterize CO2 adsorption and manufacturability of the milled powder. Both dry and wet ball milling was analyzed during the experiment. Studies were also ran on the amount of time the powder was milled, rotational speed of the milling machine, ball to powder ratio, ball to jar ratio, and ethanol to powder ratio. The processed powder was then characterized through laser diffraction, SEM, and surface measurement techniques to show that particle size and particle size distribution could be reduced, and to show the effect of the reduced particle size and particle size distribution on CO2 adsorption and manufacturability.

zeolite↗

Taking evolutionary circuit design from experimentation to implementation: some useful techniques and a silicon demonstration

Current techniques in evolutionary synthesis of analogue and digital circuits designed at transistor level have focused on achieving the desired functional response, without paying sufficient attention to issues needed for a practical implementation of the resulting solution. No silicon fabrication of circuits with topologies designed by evolution has been done before, leaving open questions on the feasibility of the evolutionary circuit design approach, as well as on how high-performance, robust, or portable such designs could be when implemented in hardware. It is argued that moving from evolutionary 'design-for experimentation' to 'design-for-implementation' requires, beyond inclusion in the fitness function of measures indicative of circuit evaluation factors such as power consumption and robustness to temperature variations, the addition of certain evaluation techniques that are not common in conventional design. Several such techniques that were found to be useful in evolving designs for implementation are presented; some are general, and some are particular to the problem domain of transistor-level logic design, used here as a target application. The example used here is a multifunction NAND/NOR logic gate circuit, for which evolution obtained a creative circuit topology more compact than what has been achieved by multiplexing a NAND and a NOR gate. The circuit was fabricated in a 0.5 mum CMOS technology and silicon tests showed good correspondence with the simulations.

digital circuits designs↗

A flight investigation of a terminal area navigation and guidance concept for STOL aircraft

A digital avionics system referred to as STOLAND has been test-flown in the NASA CV-340 to obtain performance data for time-controlled guidance in the manual flight director mode. The advanced system components installed in the cockpit included an electronic attitude director indicator and an electronic multifunction display. Navigation guidance and control computations were all performed in the digital computer. Approach paths were flown which included a narrow 180-deg turn and a 1-min, 5-deg straight-in approach to the 30-m altitude go-around point. Results are presented for 20 approaches: (1) blended radio/inertial navigation using TACAN and a microwave scanning beam landing guidance system (MODILS) permitted a smooth transition from area navigation (TACAN) to precision terminal navigation (MODILS), (2) guidance system (flight director) performance measured at an altitude of 30.5 m was within that prescribed for category II CTOL operations on a standard runway, and (3) time of arrival at a point about 2 mi from touchdown was about 4 sec plus or minus sec later than the computed nominal arrival time.

Smith, D. W.↗

NASA Tech Briefs, February 2009

Tech Briefs are short announcements of innovations originating from research and development activities of the National Aeronautics and Space Administration. They emphasize information considered likely to be transferable across industrial, regional, or disciplinary lines and are issued to encourage commercial application. Topics covered include: Measuring Low Concentrations of Liquid Water in Soil; The Mars Science Laboratory Touchdown Test Facility; Non-Contact Measurement of Density and Thickness Variation in Dielectric Materials; Compact Microwave Fourier Spectrum Analyzer; InP Heterojunction Bipolar Transistor Amplifiers to 255 GHz; Combinatorial Generation of Test Suites; In-Phase Power-Combined Frequency Tripler at 300 GHz; Electronic System for Preventing Airport Runway Incursions; Smaller but Fully Functional Backshell for Cable Connector; Glove-Box or Desktop Virtual-Reality System; Composite Layer Manufacturing with Fewer Interruptions; Improved Photoresist Coating for Making CNT Field Emitters; A Simplified Diagnostic Method for Elastomer Bond Durability; Complex Multifunctional Polymer/Carbon-Nanotube Composites; Very High Output Thermoelectric Devices Based on ITO Nanocomposites; Reducing Unsteady Loads on a Piggyback Miniature Submarine; Ultrasonic/Sonic Anchor; Grooved Fuel Rings for Nuclear Thermal Rocket Engines; Pulsed Operation of an Ion Accelerator; Autonomous Instrument Placement for Mars Exploration Rovers; Mission and Assets Database; TCP/IP Interface for the Satellite Orbit Analysis Program (SOAP); Trajectory Calculator for Finite-Radius Cutter on a Lathe; Integrated System Health Management Development Toolkit.

Source record↗

Dynamic Characterization of Galfenol (Fe81.6Ga18.4)

Galfenol has the potential to transform the smart materials industry by allowing for the development of multifunctional, load-bearing devices. One of the primary technical challenges faced by this development is the very limited experimental data on Galfenol's frequency-dependent response to dynamic stress, which is critically important for the design of such devices. This report details a novel and precise characterization of the constitutive behavior of polycrystalline Galfenol (Fe81.6Ga18.4) under quasi-static (1 Hz) and dynamic (4 to 1000 Hz) stress loadings. Mechanical loads are applied using a high-frequency load frame. Quasi-static minor and major hysteresis loop measurements of magnetic flux density and strain are presented for constant electromagnet currents (0 to 1.1 A) and constant magnetic fields 0 to 14 kA/m (0 to 180 Oe). The dynamic stress amplitude for minor and major loops is 2.88 and 31.4 MPa (418 and 4550 psi), respectively. Quasi-static material properties closely match published values for similar Galfenol materials. Quasi-static actuation responses are also measured and compared to quasi-static sensing responses; the high degree of reversibility seen in the comparison is consistent with published measurements and modeling results. Dynamic major and minor loops are measured for dynamic stresses up to 31 MPa (4496 psi) and 1 kHz, and the bias condition resulting in maximum, quasi-static sensitivity. Eddy current effects are quantified by considering solid and laminated Galfenol rods. Three key sources of error in the dynamic measurements are accounted for: (1) electromagnetic noise in strain signals due to Galfenol's magnetic response, (2) error in load signals due to the inertial force of fixturing, and (3) phase misalignment between signals due to conditioning electronics. For dynamic characterization, strain error is kept below 1.2 percent of full scale by wiring two collocated gauges in series (noise cancellation) and through leadwire weaving. Inertial force error is kept below 0.41 percent by measuring the dynamic force in the specimen using a nearly collocated piezoelectric load washer. The phase response of all conditioning electronics is explicitly measured and corrected for. In general, as frequency is increased, the sensing response becomes more linear because of an increase in eddy currents. As frequency increases above approximately 100 Hz, the elbow in the strain-versus-stress response disappears as the active (soft) regime stiffens toward the passive (hard) regime. Under constant-field conditions, the loss factors of the solid rod peak between 200 and 600 Hz, rather than exhibiting a monotonic increase. Compared to the solid rod, the laminated rod exhibits much slower increases in hysteresis with frequency, and its quasi-static behavior extends to higher frequencies. The elastic modulus of the laminated rod decreases between 100 and 300 Hz; this trend is currently unexplained.

Dynamic sensing↗

Development of beam lead RF integrated circuits

This paper describes the design and development of a set of multifunction VHF/UHF integrated circuits aimed at providing a major improvement in spacecraft radio reliability through low stress operation and the processing of these circuits in beam-lead form. The methods evolved for the high frequency characterization of the devices are discussed together with the design of suitable test fixtures. Typical test results and the distribution of test parameters are presented. A unique carrier for beam-lead devices is described, and the need for such a device is discussed. The application of the carrier to device screening, burn-in and drift measurements is discussed together with the incentives for providing these capabilities. An overview of the integration of the devices into the spacecraft radio is given and candidate assembly processes are discussed. The technology impact of this approach upon future spacecraft radio systems is qualitatively examined.

Kline, A. J.↗

Generational Analysis Reveals that TGF-Beta1 Inhibits the Rate of Angiogenesis in Vivo by Selective Decrease in the Number of New Vessels

Quantitative analysis of vascular generational branching demonstrated that transforming growth factor-beta1 (TGF-beta1), a multifunctional cytokine and angiogenic regulator, strongly inhibited angiogenesis in the arterial tree of the developing quail chorioallantoic membrane (CAM) by inhibition of the normal increase in the number of new, small vessels. The cytokine was applied uniformly in solution at embryonic day 7 (E7) to the CAMs of quail embryos cultured in petri dishes. After 24 h the rate of arterial growth was inhibited by as much as 105% as a function of increasing TGF-beta1 concentration. Inhibition of the rate of angiogenesis in the arterial tree by TGF-beta1 relative to controls was measured in digital images by three well-correlated, computerized methods. The first computerized method, direct measurement by the computer code VESGEN of vascular morphological parameters according to branching generations G(sub 1) through G(sub greater than or equal to 5), revealed that TGF-beta1 selectively inhibited the increase in the number density of small vessels, N(sub v greater than or equal to 5), (382 plus or minus 85 per square centimeter) for specimens treated with 1 microgram TGF-beta1/CAM for 24 h, compared to 583 plus or minus 99 per square centimeter for controls), but did not significantly affect other parameters such as average vessel length or vessel diameter. The second and third methods, the fractal dimension (D(sub f)) and grid intersection (rho (sub v)), are statistical descriptors of spatial pattern and density. According to D(sub f) and rho(sub v), arterial density increased in control specimens from 1.382 plus or minus 0.007 and 662 plus or minus 52 per square centimeters at E7 (0 h) to 1.439 plus or minus 0.013 and 884 plus or minus 55 per square centimeters at E8 (24 h), compared to 1.379 plus or minus 0.039 and 650 plus or minus 111 per square centimeter for specimens treated with 1 microgram TGF-beta1/CAM for 24 h. TGF-beta1 therefore regulates vascular pattern and the rate of angiogenesis in a unique fingerprint manner, as do other major angiogenic regulators that include VEGF, FGF-2 (bFGF), and angiostatin. TGF-beta1 did not stimulate angiogenesis significantly at low cytokine concentrations, which suggests that this quail CAM model of angiogenesis is not associated with an inflammatory response.

Parsons-Wingerter, Patricia↗

Release Properties and Electrochemical Characterization of Encapsulated Corrosion Inhibitors for Environmentally Friendly Smart Coatings

The NASA Kennedy Space Center's Corrosion Technology Lab at the Kennedy Space Center in Florida, U.S.A. has been developing multifunctional smart coatings based on the microencapsulation of environmentally friendly corrosion indicators, inhibitors and self-healing agents. This allows for the incorporation of autonomous corrosion control functionalities, such as corrosion detection and inhibition as well as the self-healing of mechanical damage, into coatings. This paper presents technical details on the characterization of inhibitor-containing particles and their corrosion inhibitive effects using electrochemical and mass loss methods. Three organic environmentally friendly corrosion inhibitors were encapsulated in organic microparticles that are compatible with desired coatings. The total inhibitor content and the release of one of the inhibitors from the microparticles in basic solution was measured. Particles with inhibitor contents of up 60 wt% were synthesized. Fast release, for immediate corrosion protection, as well as long-term release for continued protection, was observed. The inhibition efficacy of the inhibitors, both as the pure materials and in microparticles, on carbon steel was evaluated. Polarization curves and mass loss measurements showed that, in the case of 2MBT, its corrosion inhibition effectiveness was greater when it was delivered from microparticles.

Coatings↗

Optical Characteristics of Radiated Multifunctional Optical Materials

The performance of optical and electronic materials, and devices are affected significantly in space due to exposure from high energy radiations. We have been investigating the effect of -ray radiations on multifunctional binary and ternary selenide and halide crystals. These materials have shown excellent performance for the wavelength conversion in MWIR and LWIR regions, acousto-optics, and great potential for radiation detection. Crystals with high Z materials such as thallium, mercury and lead based compounds have great potential for the development of a variety of devices and components suitable for space applications. We will report on the characteristics of several halides including mercurous halides (Hg2X2, X= Cl, Br, I), Thallium mercury iodide (Tl4HgI4) and thallium arsenic selenide and thallium gallium selenide, and ternary selenides. These crystals, synthesized with high purity source materials, will be evaluated by studying optical characteristics and measuring resistivity after exposure to a 137Cs -ray source.

Radiation↗

Measuring Titanium Heat Pipe Thermal Conductivity for CO2 Adsorption Systems

Current models of the Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC) being developed for long duration space exploration utilize cooling chambers and heat plates to adsorb and desorb contaminants -13 . To reduce resources required and lower the equivalent system mass (ESM), the study focuses on determining the applications of titanium heat pipe systems to operate both phases, allowing for future research into the development of a heat pipe chamber to hold the zeolite formulations.

multifunctional sorbent↗

Characterization of Encapsulated Corrosion Inhibitors Containing Microparticles for Environmentally Friendly Smart Coatings

This poster presents the results obtained from experiments designed to evaluate the release properties, as well as the corrosion inhibition effectiveness, of several encapsulated corrosion inhibitors. Microencapsulation has been used in the development of environmentally friendly multifunctional smart coatings. This technique enables the incorporation of autonomous corrosion detection, inhibition and self-healing functionalities into many commercially available coating systems. Select environmentally friendly corrosion inhibitors were encapsulated in organic and inorganic pH-sensitive microparticles and their release in basic solutions was studied. The release rate results showed that the encapsulation can be tailored from fast, for immediate corrosion protection, to slow, which will provide continued long-term corrosion protection. The incorporation of several corrosion inhibitor release profiles into a coating provides effective corrosion protection properties. To investigate the corrosion inhibition efficiency of the encapsulated inhibitors, electrochemical techniques were used to obtain corrosion potential, polarization curve and polarization resistance data. These measurements were performed using the free as well as the encapsulated inhibitors singly or in combinations. Results from these electrochemical tests will be compared to those obtained from weight loss and other accelerated corrosion experiments.

Coatings↗

Effect of Radiation on Biologically Active Glasses

Multifunctional hydroxyapatites single crystals have been studied for their applications as the laser host material since past several decades. It is only recently their potential has been evaluated for bioactive materials. In the past researches, Czochralski and flux growth methods have been utilized to achieve single crystals. We have used low temperature processing techniques for synthesis. Organic melt was used to achieve oriented fibers by the directional solidification method. This organic treated material has different characteristics than coarsened oxide materials. Our approach involved low temperature processing using nano engineered powders of the material system Na2O-K2O-CaO- MgO-SrO-SiO2. Also, borates were processed by sintering and grain growth. Effect of -ray was studied by measuring the electrical characteristics of radiated samples. Our experiments to further improve mechanical characteristics indicate that substitution of calcium with some other elements such as gallium have great potential to improve the radiation hardening and mechanical properties of bones.

Tufail, Areeba↗