Search NASASearch

SEARCH · Search NASA

Results for “mirror characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Grazing Incidence Wavefront Sensing and Verification of X-Ray Optics Performance

Evaluation of interferometrically measured mirror metrology data and characterization of a telescope wavefront can be powerful tools in understanding of image characteristics of an x-ray optical system. In the development of soft x-ray telescope for the International X-Ray Observatory (IXO), we have developed new approaches to support the telescope development process. Interferometrically measuring the optical components over all relevant spatial frequencies can be used to evaluate and predict the performance of an x-ray telescope. Typically, the mirrors are measured using a mount that minimizes the mount and gravity induced errors. In the assembly and mounting process the shape of the mirror segments can dramatically change. We have developed wavefront sensing techniques suitable for the x-ray optical components to aid us in the characterization and evaluation of these changes. Hartmann sensing of a telescope and its components is a simple method that can be used to evaluate low order mirror surface errors and alignment errors. Phase retrieval techniques can also be used to assess and estimate the low order axial errors of the primary and secondary mirror segments. In this paper we describe the mathematical foundation of our Hartmann and phase retrieval sensing techniques. We show how these techniques can be used in the evaluation and performance prediction process of x-ray telescopes.

Saha, Timo T.

Assessment of MODIS Scan Mirror Reflectance Changes On-Orbit

Since launch, the NASA EOS Terra and Aqua MODIS have operated successfully for more than 8 and 6 years, respectively. MODIS collects data using a two-sided scan mirror over a large scan angular range. The scan mirror is made of a polished, nickel-plated beryllium base coated with high purity silver, which is then over-coated with the Denton proprietary silicon monoxide and silicon dioxide mixture. The scan mirror's reflectance was characterized pre-launch using its witness samples, and the response versus scan angle was measured at the sensor system level. In this study, we present an assessment of MODIS scan mirror on-orbit degradation by examining changes of spectral band response over each sensor's mission lifetime. Results show that the scan mirror's optical properties for both Terra and Aqua MODIS have experienced significant degradation since launch in the VIS spectral region, which is mirror side dependent as well as scan angle dependent. In general, the mirror degradation is more severe for Terra MODIS than Aqua MODIS, especially during recent years. For Terra MODIS, the degradation rate is noticeably different between the mirror sides. On the other hand, there has been little mirror side dependent difference for Aqua MODIS.

Xiong, Xiaoxiong

Sensor Performance Assessment for Terra and Aqua MODIS Using Unscheduled Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) has been in operation for over 18 and 16 years on the Terra and Aqua spacecrafts, respectively. In order to maintain long-term calibration stability over the life of each mission, MODIS uses a set of on-board calibrators as well as observations of the Moon and selected Earth-view targets. The lunar observations nominally occur in a narrow phase angle range, 55 degrees - 56 degrees, and use scheduled spacecraft maneuvers in order to bring the Moon into alignment with the MODIS space-view port. These observations are used to help characterize the MODIS scan-mirror response versus scan-angle. In addition to these scheduled lunar observations, MODIS also views the Moon through the space-view port without a spacecraft maneuver when the geometry is appropriately aligned. This occurs over a wider phase angle range, between 51 degrees - 82 degrees, than those of the scheduled moon observations. While the phase angle restriction of our scheduled observations provides consistency between the calibration events, the unscheduled Moon data can provide a valuable assessment of many calibration related investigations that use the Moon. In this paper, we compare the results of unscheduled versus scheduled lunar observations for several sensor calibration and performance assessments. These include the lunar calibration trending used to characterize the scan-mirror response versus scan angle and the electronic crosstalk correction of bands 27-30, which are currently used in the MODIS Level-1B data products, as well as sensor performance assessments such as band-to-band and detector-to-detector spatial registration.

Aqua

Deformable Mirrors Capture Exoplanet Data, Reflect Lasers

To image and characterize exoplanets, Goddard Space Flight Center turned to deformable mirrors (DMs). Berkeley, California-based Iris AO, Inc. worked with Goddard through the SBIR program to improve the company’s microelectromechanical DMs, which are now being evaluated and used for biological research, industrial applications, and could even be used by drug manufacturers.

Source record

Testing the James Webb Space Telescope Primary Mirror

JWST in-process optical testing and cryogenic requirement compliance certification, verification andvalidation was probably the most difficult metrology job of our generation in astronomical optics. But, the challenge was met: by hard work of dozens of optical metrologists; development and qualification of multiple custom test setups; and several new inventions, including 4D PhaseCam and Leica Absolute Distance Meter. This paper summarizes the metrology tools, test setups and processes used to characterize the JWST primary mirror.

Stahl, H. Philip

Demonstration and Automation of Reflected Target Optical Measurement for Heliostats

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.

CSP

Characterization of Plasma Discharges in a High-Field Magnetic Tandem Mirror

High density magnetized plasma discharges in open-ended geometries, like Tandem Mirrors, have a variety of space applications. Chief among them is the production of variable Specific Impulse (I(sub sp)) and variable thrust in a magnetic nozzle. Our research group is pursuing the experimental characterization of such discharges in our high-field facility located at the Advanced Space Propulsion Laboratory (ASPL). These studies focus on identifying plasma stability criteria as functions of density, temperature and magnetic field strength. Plasma heating is accomplished by both Electron and Ion Cyclotron Resonance (ECR and ICR) at frequencies of 2-3 Ghz and 1-30 Mhz respectively, for both Hydrogen and Helium. Electron density and temperature has measured by movable Langmuir probes. Macroscopic plasma stability is being investigated in ongoing research.

Chang-Diaz, Franklin R.

Initial test bed concentrator characterization

The operational characteristics and the mirror alignment technique of the test bed concentrator control system are highlighted. The final design of the TBC control system provided one axis of fast slew capability so that either the Sun acquisition or emergency off-Sun mode could be obtained in a minimum time. The procedure for getting on and off Sun is to run the elevation axis up to the approximate elevation of the Sun for the particular time of acquisition and then slew the concentrator on Sun in azimuth. The automatic Sun-acquisition system is controlled by two Sun sensors, one for each axis; each has a 2deg acquisition cone angle within which the concentrators are programmed to point. The mirror alignment technique chosen utilized a semi-distant incandescent light source which produced a reflected image on the focal point target. The concentrator was boresighted to the light by moving the concentrator while sighting along the cross hairs and through the apertures in the disks to the light source resulting in a maximum point error of 0.11 deg. Test plans to install a solar flux mapper to characterize the solar spot and to measure the size, shape, and intensity of the Sun's image are outlined.

Starkey, D. J.

Optical and X-ray observations of faint quasars in an optically selected sample

The confirmation of six quasars from spectrographic observations made in 1981 using the Multiple Mirror Telescope, and the characterization of 10 quasars from 1980 Einstein-Observatory X-ray observations (using both imaging proportional counter and high-resolution imager), are reported. The candidates had been selected by Formiggini et al. (1980) in a 1.72-sq-deg region centered on 13h 6 deg, on the basis of ultraviolet excess and a limiting B magnitude of 19.20. A total sample of 10 UV-excess quasars of this magnitude has now been confirmed, for an integral surface density of 5.8 + or - 1.8 per sq deg. Confirmation of three objects from another sample with B less than 18.25 as quasars yielded a surface density of 0./59 + or - 0.13 per sq deg at that magnitude. Data from the complete samples were used to compute the number-flux relation, found to be described by a power law with a 2.25 index for quasars with B between 17.0 and 19.2. From the X-ray observations it was determined that quasars with z less than 2.2 and B less than 19.20 contribute about 15 percent to the cosmic 2-keV background.

Marshall, H. L.

Correspondence between AXAF TMA X-ray performance and models based upon mechanical and visible light measurements

The AXAF Technology Mirror Assembly (TMA) was characterized prior to X-ray testing by properties measured mechanically or with visible light; these include alignment offsets, roundness and global-axial-slope errors, axial-figure errors with characteristic lengths greater than about five mm, and surface roughness with scale lengths between about 0.005 and 0.5 mm. The X-ray data of Schwartz et al. (1985) are compared with predictions based upon the mechanical and visible light measurements.

Van Speybroeck, L.

Status of Gr/glass composites technology at UTOS

The TSC (Thermally Stable Composite) refers to a family of graphite reinforced glass matrix composite materials developed by UTOS. This fiber matrix combination exhibits low coefficients of thermal expansion (CTE), exceptional dimensional stability, high specific strength and stiffness, adequate fracture toughness, and space environment compatibility. The dimensional stability of a TSC mirror structure was experimentally characterized at the Steward Observatory. Preliminary results indicate that TSC is significantly more thermally stable than most current structural composite materials. In addition, the use of lower CTE glass matrix materials, such as 96 percent silica glass, have the potential for producing graphite/glass panels with expansion rates and stability comparable to that of fused silica.

Mayor, Ramon A.

Looking at Hubble Through the Eyes of JWST

The phase retrieval algorithm developed for the James Webb Space Telescope (JWST) is used to process archival image data that was originally used to characterize the Hubble primary mirror edge defect. The Hubble mirror conic constant is inferred from these results and comparisons are made with earlier conic values reported by teams comprising the HARP (Hubble Aberration Recovery Project) study. A number of important lessons learned from the Hubble phase retrieval problem are described and a discussion is given on how these have been incorporated into the JWST Observatory design.

Dean, Bruce H.

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS

Environmental and Polarization Characterizations of E-Beam Plasma-Based AlF 3 -Passivated Aluminum Mirrors for Astronomical Telescopes

Astronomical space telescopes to study astrophysical phenomena from the far ultraviolet (FUV) to the near infrared (NIR) will require mirror coatings with high reflectance over this entire spectral region. While coatings for the optical and NIR part of the spectrum are fairly well developed with proven performance, the FUV range has presented significant challenges, particularly below 120nm. Recent developments in electron-beam (e-Beam) generated plasma treatment in a SF 6 environments has enabled the effective passivation of aluminum (Al) coatings for applications in the FUV, by native oxide removal and the formation of a AlF 3 passivation layer which could be tuned to any desired AlF 3 thickness. These results have been produced through a collaboration between the Goddard Space Flight Center (GSFC) and the Naval Research Laboratory (NRL). The passivation experiments have been carried out using the Large Area Plasma Processing System (LAPPS) at NRL using bare aluminum samples and provided by the coating group at GSFC. This novel procedure has demonstrated improved Al mirrors with state-of-the-art FUV reflectivity (e.g. R=91% at 121.6nm). In this paper, we will be reporting on environmental testing, micro-roughness, as well as polarization studies of these E-beam treated samples. These characterizations are being done in order to advance the Technology Readiness Level (TRL) for these Al+AlF 3 mirror coatings produced at LAPPS. The ultimate goal is to demonstrate the promise of using this coating technology to deliver reflectance performance plus stability and uniformity over a large area for a future IR/O/UV space telescope observatory.

FUV reflectance

Optical Testing Using Portable Laser Coordinate Measuring Instruments

High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

Khreishi, M.

Optical Testing Using Portable Laser Coordinate Measuring Instruments

High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LR's ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikon's MV-224/350 LR and Leica's Absolute Tracker AT401/402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the "direct and through" (D&T), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the D&T shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

Khreishi, Manal

New Method for Characterizing the State of Optical and Opto-Mechanical Systems

James Webb Space Telescope Optical Telescope Element (OTE) is a three mirror anastigmat consisting of a 6.5 m primary mirror (PM), secondary mirror (SM) and a tertiary mirror. The primary mirror is made out of 18 segments. The telescope and instruments will be assembled at Goddard Space Flight Center (GSFC) to make it the Optical Telescope Element-Integrated Science Instrument Module (OTIS). The OTIS will go through environmental testing at GSFC before being transported to Johnson Space Center for testing at cryogenic temperature. The objective of the primary mirror Center of Curvature test (CoC) is to characterize the PM before and after the environmental testing for workmanship. This paper discusses the CoC test including both a surface figure test and a new method for characterizing the state of the primary mirror using high speed dynamics interferometry.

Optical Testing

Scattering defects in silver mirror coatings

Scatter centers common to protected silver have been investigated on a variety of space flight quality mirrors. The defects have been characterized as to number density, size, location within the film layer structure, and dependence on illumination angle. In addition the total integrated scatter values as a function of wavelength, humidity test soak time, and temperature have been determined for some mirrors. These submicrometer sized defects are believed to be the precursors of silver corrosion spots. A mechanism for their generation is proposed, and measures to reduce their occurrence are suggested.

Pellicori, S. F.