Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular tunability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cancer Detection Using Neural Computing Methodology

This paper describes a novel learning methodology used to analyze bio-materials. The premise of this research is to help pathologists quickly identify anomalous cells in a cost efficient method. Skilled pathologists must methodically, efficiently and carefully analyze manually histopathologic materials for the presence, amount and degree of malignancy and/or other disease states. The prolonged attention required to accomplish this task induces fatigue that may result in a higher rate of diagnostic errors. In addition, automated image analysis systems to date lack a sufficiently intelligent means of identifying even the most general regions of interest in tissue based studies and this shortfall greatly limits their utility. An intelligent data understanding system that could quickly and accurately identify diseased tissues and/or could choose regions of interest would be expected to increase the accuracy of diagnosis and usher in truly automated tissue based image analysis.

liquid crystal tunable filters↗

Development and applications of tunable, narrow band lasers and stimulated Raman scattering devices for atmospheric lidar

The main thrust of the program was the study of stimulated Raman processes for application to atmospheric lidar measurements. This has involved the development of tunable lasers, the detailed study of stimulated Raman scattering, and the use of the Raman-shifted light for new measurements of molecular line strengths and line widths. The principal spectral region explored in this work was the visible and near-IR wavelengths between 500 nm and 1.5 microns. Recent alexandrite ring laser experiments are reported. The experiments involved diode injection-locking, Raman shifting, and frequency-doubling. The experiments succeeded in producing tunable light at 577 and 937 nm with line widths in the range 80-160 MHz.

Wilkerson, Thomas D.↗

Summary Abstract: Vibrations of Ammonia on the Cu (100) Surface

Recently, the TR frequencies for NH3 molecularly adsorbed on Cu(100) have been measured by infrared laser-induced photodesorption using a tunable laser operating in the group frequency range. Additionally, photodesorption, photo-fragmentation, and photoionization has been observed using a CO2 laser in the 10 microns range. In this contribution we report on work in progress where we use quantum chemical methods to analyze the shifts in the NH, frequencies relative to the gas phase upon chemisorption. We also compute the Cu- N stretch vibration, which has been observed experimentally,and the change in the IR intensities associated with chemisorption; this change is insufficient by itself to explain the increased photoionization efficiency observed.

Pettersson, Lars G. M.↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Monolithic InGaAs JFET Active Pixel Tunable Image Sensor (MAPTIS)

A new Monolithic InGaAs Active Pixel Multispectral Image Sensor is described. This Infrared sensor will utilize high quality InGaAs grown by Molecular Beam Epitaxy on InP substrate for the fabrication of a high speed Junction Field Effect Transistor array.

hyper↗

Optical Characterization and 2,525 micron Lasing of Cr(2+):Cd(0.85)Mn(0.15)Te

Transition metal doped solids are of significant current interest for the development of tunable solid-state lasers for the near and mid-infrared (1-4 pm) spectral region. Applications of these lasers include basic research in atomic, molecular, and solid-state physics, optical communication, medicine, and environmental studies of the atmosphere. In transition metal based laser materials, absorption and emission of light arises from electronic transitions between crystal field split energy levels of 3d transition metal ions. The optical spectra generally exhibit broad bands due to the strong interaction between dopant and host (electron-phonon coupling). Broad emission bands offer the prospect of tunable laser activity over a wide wavelength range, e.g. the tuning range of Ti:Sapphire extends from 700-1100 run. The only current transition metal laser operating in the mid-infrared wavelength region (1.8-2.4 micro-m) is CO(2+):MgF2, but its performance is severely limited due to strong nonradiative decay at room temperature. Based on lifetime data, the quantum efficiency is estimated to be less than 3 deg/0 11,21. In general, the probability for non-radiative decay via multi-phonon relaxation increases with decreasing energy gap between ground and excited state. Therefore, efficient transition metal lasers beyond -1.6 micro-m are rare. Recently, tunable laser activity around 2.3 micro-m was observed from Cr doped ZnS and ZnSe. The new lasing center in these materials was identified as Cr(2+) occupying the tetrahedral Zn site. Tetrahedrally coordinated optical centers are rather unusual among transition metal lasers. Their potential usefulness, however, has been demonstrated by the recent development of near infrared laser materials such as Cr:forsterite and Cr:YAG, which are based on tetrahedrally coordinated Cr(4+) ions. According to the Laporte selection rule, electric-dipole transition within the optically active 3d-electron shells are parity forbidden. However, a static acentric electric crystal field or the coupling of asymmetric phonons can force electric-dipole transitions by the admixture of wave functions with opposite parity. Tetrahedral sites lack inversion symmetry which provides the odd-parity field necessary to relax the parity selection rule. Therefore, high absorption and emission cross sections are observed. An enhanced radiative emission rate is also expected to reduce the detrimental effect of non-radiative decay. Motivated by the initial results on Cr doped ZnS and ZnSe, we have started a comprehensive effort to study Cr(2+) doped II-VI semiconductors for solid-state laser applications. In this paper we present the optical properties and the demonstration of mid-infrared lasing from Cr doped Cd(0.85)Mn(0.15)Te.

Davis, V. R.↗

Development and Application of Novel Diagnostics for Arc-Jet Characterization

This NASA-Ames University Consortium Project has focused on the design and demonstration of optical absorption sensors using tunable diode laser to target atomic copper impurities from electrode erosion in thc arc-heater metastable electronic excited states of molecular nitrogen, atomic argon, aid atomic oxygen in the arcjet plume. Accomplishments during this project include: 1. Design, construction, and assembly of optical access to the arc-heater gas flow. 2. Design of diode laser sensor for copper impurities in the arc-heater flow. 3 . Diode laser sensor design and test in laboratory plasmas for metastable Ar(3P), O(5S), N(4P), and N2(A). 4. Diode laser sensor demonstration measurements in the test cell to monitor species in the arc-jet plume.

Hanson, R. K.↗

NASA multipurpose airborne DIAL system and measurements of ozone and aerosol profiles

The hardware, operational characteristics, data processing system, and applications of the NASA airborne differential absorption lidar (DIAL) system are described. DIAL functions by assessing the average gas concentration over a specified range interval by analyzing the difference in lidar backscatter signals for laser wavelengths tuned on and off of the molecular absorption line of a gas under investigation. The system comprises two frequency-doubled Nd:YAG lasers pumping two high conversion efficiency tunable dye lasers emitting pulses separated by 100 microsec or less. The return signals are digitized and stored on magnetic tape. The signal collector consists of photomultiplier tubes implanted in a cassegrain telescope. Flight tests of the system involved on-measurements at 285.95 nm and off-measurements at 299.40 nm, which yielded a differential cross section of 1.74 x 10 to the -16th sq cm. In situ measurements with another plane at a nominal altitude of 3.2 km for comparison purposes showed accuracy to within 10% in and above the boundary layer. The system is considered as a test apparatus for more developed versions to be flown on the Shuttle

Browell, E. V.↗

Lidar profiling of thermodynamic properties of the atmosphere

Principles and applications of pulsed laser methods for temperature, pressure, density, and humidity measurements in the altitude range 0-100 km are discussed. The differential absorption lidar (DIAL) method requires that at least one of the transmitted laser pulses be carefully tuned onto an absorption feature of the species, whereas Raman backscatter methods do not require tunability. OH and Na fluorescence require tuning of the excitation, and are the most suitable methods for high altitude where the atomic and molecular reemission is relatively unquenched by collisions.

Wilkerson, T. D.↗

Chaos: Understanding and Controlling Laser Instability

In order to characterize the behavior of tunable diode lasers (TDL), the first step in the project involved the redesign of the TDL system here at the University of Tennessee Molecular Systems Laboratory (UTMSL). Having made these changes it was next necessary to optimize the new optical system. This involved the fine adjustments to the optical components, particularly in the monochromator, to minimize the aberrations of coma and astigmatism and to assure that the energy from the beam is focused properly on the detector element. The next step involved the taking of preliminary data. We were then ready for the analysis of the preliminary data. This required the development of computer programs that use mathematical techniques to look for signatures of chaos. Commercial programs were also employed. We discovered some indication of high dimensional chaos, but were hampered by the low sample rate of 200 KSPS (kilosamples/sec) and even more by our sample size of 1024 (1K) data points. These limitations were expected and we added a high speed data acquisition board. We incorporated into the system a computer with a 40 MSPS (million samples/sec) data acquisition board. This board can also capture 64K of data points so that were then able to perform the more accurate tests for chaos. The results were dramatic and compelling, we had demonstrated that the lead salt diode laser had a chaotic frequency output. Having identified the chaotic character in our TDL data, we proceeded to stage two as outlined in our original proposal. This required the use of an Occasional Proportional Feedback (OPF) controller to facilitate the control and stabilization of the TDL system output. The controller was designed and fabricated at GSFC and debugged in our laboratories. After some trial and error efforts, we achieved chaos control of the frequency emissions of the laser. The two publications appended to this introduction detail the entire project and its results.

Blass, William E.↗

Tunable Heterodyne Receiver from 100 Micron to 1,000 Micron for Airborne Observations

Interest in high resolution spectrometers for the submillimeter wavelength range from 100 micron to 1,000 micron is mostly stimulated by molecular spectroscopy in radioastronomy and atmospheric physics, and by plasma diagnostic experiments. Schottky diodes in waveguide mixer technology and InSb-hot electron bolometers are successfully used in the 0.5 to a few millimeter range whereas tandem Fabry-Perot spectrometers combined with photoconductive detectors (Ge:Sb and Ge:Ga) are used for the 100 micron range. Recent research on heterodyne spectrometers, with Schottky diodes in an open structure mixer and a molecular laser as local oscillators, which can be used over the whole wavelength range is summarized.

Roeser, H. P.↗

Laboratory diode laser spectroscopy in molecular planetary astronomy

Infrared spectroscopy of planetary atmospheres is performed at high spectral resolution comparable to that in the laboratory. This requires that laboratory spectroscopy use the highest resolution and the most accurate techniques. Tunable diode laser spectroscopy can supply many of the spectroscopic parameters needed by astronomers. In particular, line positions, line strengths, and collisional line widths are measured with diode lasers, and these are often among the best values available. Diode laser spectra are complimentary to lower resolution, broader-coverage Fourier transform spectra. Certain procedures must be adopted, however, when using diode lasers, for determining their output characteristics and for calibrating each spectrum against quality references.

Jennings, D. E.↗

Challenges of Building, Launching, and Operating The Curiosity SAM Instrument on Mars

The Sample Analysis at Mars (SAM) Suite Investigation onboard the Mars Science Laboratory (MSL) Curiosity rover is currently roving up Mt Sharp in Gale Crater on Mars. It is investigating the present and past habitability of Mars by exploring molecular and elemental chemistry relevant to life. SAM is a suite of three instruments, a Quadrupole Mass Spectrometer (QMS), a Gas Chromatograph (GC), and a Tunable Laser Spectrometer (TLS). As Curiosity climbs Mt. Sharp, SAM’s instrument suite search for and measure the abundances of carbon, oxygen, hydrogen, and nitrogen - elements that are associated with life as we know it. SAM quantitatively addresses the habitability of Mars, an essential step in the search for past or present life on Mars. This talk provides a behind-the-scenes look at the vignettes of the engineering challenges of building, integrating, testing, launching, and the SAM’s team’s initial experiences of operating SAM on Mars.

Florence Tan↗

Study of Molecular Line Parameters down to Very Low Temperature

The impact of precise spectroscopic measurements on the P(9) multiplet in the v3 band of 12CH4, obtained using a newly developed cold Herriott cell coupled with a tunable diode laser spectrometer, is examined in the context of remote sensing of methane in the atmosphere. More specifically, the influence of the air-broadening temperature dependence, of line narrowing and of line-mixing effects is assessed when fitting high resolution atmospheric spectra recorded from a balloon in the solar occultation mode. This is achieved by considering residuals and retrieved methane volume mixing ratio profiles. By combining data from previous studies together with new measurements, the expression for the temperature dependence of the broadening coefficient has been revisited. It is shown that a correcting factor applied to the usual law gives better results, when considering all the available measurements from room temperature down to about 10-20 K, as compared to the usual expression of the width versus temperature. These results clearly demonstrate that collision broadening is more sensitive to long-range attractive forces when the temperature is decreased.

Mondelain, D.↗

Measurement of collision-induced shift and broadening of the ultraviolet transitions of OH

Using a CW tunable laser, absorption measurements were made to determine for the first time the shift and broadening of the ultraviolet transitions of OH induced by collisions with molecular nitrogen and oxygen. Similar measurements were also made for collisions with air and inert gases He, Ne, Ar, and Kr. Both the shift and broadening due to these collisions were found to depend linearly upon pressures in the range from 50 Torr up to 1 atm. The homogeneous linewidth for the P2(2) transition of OH in ambient air is determined to be 0.20 + or - 0.005/cm. Results with Ar and Kr show contributions not accounted for by the polarizability of the colliding species.

Shirinzadeh, B.↗

A measurement of the vibrational band strength for the upsilon sub 3 band of the HO2 radical

The HO2 radicals generated in a discharge-flow system were observed with tunable diode laser absorption in the P-branch of the nu(3) vibrationall band at 1080/cm. The observed line positions agree with those calculated from the molecular constants for the nu(3) bland obtained from a previous study using laser magnetic resonance spectroscopy. The band strength was determined by observing line center absoptions when HO2 is produced in the reaction F + H2O2 yields HO2 + HF (k1) with a measured concentration of atomic fluorine and excess hydrogen peroxide. F-atom concentrations are measured by diode laser absorption of the spin-orbit transition at 404/cm. The analysis accounts for HO2 losses due to the reactions of HO2 + HO2 yields H2O2 + O2 (k3) and F + HO2 yields HF + O2 (k4). The line strength for the 6(15) 7(16) F(1) transition is 2.9 x 10 to the 21st power sq cm/molecule/cm which corresponds to a nu(3) band strength of 34 +/- 9 sq/cm(STP atm). This value is a factor of 6 lower than previous ab initio calculations. These results will be useful in assessing the feasibility of atmospheric measurements of HO2 using infrared absorption techniques.

Zahniser, M. S.↗

Advances in Direct Detection Doppler Lidar Technology and Techniques

In this paper we will describe the ground based Doppler lidar system which is mounted in a modified delivery van to allow field deployment and operations. The system includes an aerosol double edge receiver optimized for aerosol backscatter Doppler measurements at 1064 nm and a molecular double edge receiver which operates at 355 nm. The lidar system will be described including details of the injection seeded diode pumped laser transmitter and the piezoelectrically tunable high spectral resolution Fabry Perot etalon which is used to measure the Doppler shift. Examples of tropospheric wind profiles obtained with the system will also be presented to demonstrate its capabilities.

Gentry, Bruce↗