Search NASA⌕ Search

SEARCH · Search NASA

Results for “natural circulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a MOOSE thermal model of the MPC-32 canister and HI-STORM overpack

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing and Simulation of an Updated Cartridge Loop Vehicle

The Versatile Test Reactor (VTR) is a sodium-cooled, fast-spectrum test reactor that is being developed in the United States and will support a variety of irradiation test vehicle configurations, including cartridge loops. This work includes out-of-pile experimental results from a single-phase, natural circulation cartridge loop vehicle with geometry relevant to VTR irradiation sites, as well as comparisons between the experimental results and results predicted using the TRAC/RELAP Advanced Computational Engine (TRACE) modeling tool. The experiments were conducted in the thermosyphon test loop (TSTL) facility at Oak Ridge National Laboratory. Comparisons are also made between the current experimental data and results from natural circulation experiments previously conducted in the TSTL in a cartridge vehicle that is similar in design but has smaller flow areas. This cartridge vehicle and the experimental program were developed to add to the single-phase, natural circulation data collected in the previous iteration of the cartridge loop design, which supports future irradiation experiments and adds to a database that is useful for validating computer models. Comparisons of experimental results to TRACE model predictions is a pertinent step in validating the computational tool for supporting future irradiation experiment design and safety calculations, and comparisons to previous cartridge loop results highlight the impact of the design changes made to the test vehicle. The experiments conducted include several steady state tests and transients, including power ramp, loss of offsite power, and loss of external flow scenarios. This work shows that TRACE can accurately predict temperatures and flow conditions in the cartridge loop and the updated vehicle design achieves higher mass flow rates at the same steady state power levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A hybrid porous model for full reactor core scale CFD investigation of a prismatic HTGR

Three-dimensional (3-D) Computational Fluid Dynamics (CFD) analysis of a whole nuclear reactor core is a tremendous challenge due to the large geometric volume and complex structures. Here, this research presents a hybrid porous (HP) model to simplify a prismatic High Temperature Gas-cooled Reactor (HTGR) core, so 3-D CFD investigation can be performed on a full reactor core scale. In the HP model, the prototypic small coolant channels in the nuclear fuel blocks are lumped together to form multiple equivalent large coolant channels, and then the porous medium flow model is applied to each of them. Therefore, heat transfer in fuel blocks is computed by a hybrid combination of solid energy and porous flow energy equations. The similarity between the HP model and prototypic model is achieved by deriving the porous flow permeability, inertial resistance factor, and artificial thermophysical properties. Compared with the widely used whole porous (WP) flow model, the HP model preserves more realistic geometric structures, and therefore more accurate physical processes. The General Atomics' Modular High Temperature Gas-cooled Reactor (MHTGR) design was chosen as a prototype to demonstrate the methodology. Simulations were performed using the prototypic CFD model and HP model at steady-state forced circulation, steady-state natural circulation, and transient conditions that correspond to normal operation, extended period of pressurized cool down, and short-term transients after reactor shutdown, respectively. The comparison shows good agreement between the HP model and prototypic model in the maximum fuel temperature, average solid temperature, and helium flow rate, which demonstrates the potential applicability of the HP model for a full reactor core scale simulation in the future. As a benefit, the HP model reduces the mesh quantity by a factor of 50 from a prototypic model. Correspondingly, the computation time was reduced by a factor of at least 30.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal-Hydraulic-Mechanical Modeling and Simulation of Sodium-Potassium–Cooled MARVEL Microreactor Core

The U.S. Department of Energy's Microreactor Program, with Idaho National Laboratory's development of a nuclear microreactor applications test bed named MARVEL, aims to support R&D for the deployment of small, transportable reactors across civilian, industrial, and defense sectors. The MARVEL microreactor, an 85-kWth thermal fission reactor, incorporates TRIGA nuclear fuel and a sodium-potassium eutectic as its primary coolant, designed for safety and efficiency, with natural circulation eliminating the risk of critical heat flux conditions. The reliance on natural circulation for primary cooling means the reactor avoids using fuel spacers to minimize core pressure drop, which could disrupt the primary coolant's natural flow. However, the reactor core’s tight P/D ratio of 1.05, in the absence of fuel spacers, could pose a risk of fuel rod contact and increased peak cladding temperatures. To ensure the reactor safety, this study conducted computational modeling and simulations to investigate the reactor's thermal-hydraulic-mechanical characteristics, including the reactor core heat transfer coefficients, the potential for rod-to-rod contact, and assessed its impact on peak cladding temperature and overall reactor safety. The computational analyses of the MARVEL microreactor core revealed that the thermal deformation of fuel rods under worst-case scenario may lead to the fuel rod contact, but the peak cladding temperatures will remain significantly lower than the safety criteria, ensuring the safety operation reactor without fuel spacers under normal operating conditions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

TRACE Analysis of the STS Target Flow Loop Conceptual Design

This report documents the efforts to model the conceptual design of the STS natural circulation flow loop using TRACE. The results, summarized in Section 2.1, support the conclusion that the conceptual STS natural circulation flow loop design provides sufficient cooling of the tungsten target and exhibits predictable flow behavior, provided that certain design features and/or operating conditions are used. In particular: A sufficient initial liquid volume fraction is required to avoid dryout of the target flow channels; Inclusion of a pressurizer or bellows volume at the top of the loop is recommended and is capable of achieving steady, non-oscillatory flow and temperature conditions at sufficiently high loop pressure. Section 1 provides a detailed description of the geometry and assumptions used in the model, and Section 2 presents the results for the current flow loop design as well as some investigation of potential design modifications with the goal of enhancing the thermal hydraulic stability of the loop.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Device for steam cladding oxidation testing at TREAT

To compare the chemical degradation of conventional zirconium alloy (Zry) cladding to advance silicon carbide (SiC) cladding in a post loss of coolant accident (LOCA) environment, new nuclear testing capabilities are necessary. The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory (INL) has matured its transient fuel testing capabilities since its 2017 restart. The most recent experiment architecture is the Transient Water Irradiation System in TREAT (TWIST), which is designed to support qualification of accident tolerant fuels in light water reactors. INL has designed and analyzed a natural circulation steam flow modification for TWIST to produce prototypic conditions of cladding oxidation. The in-situ device will be electrically heated to drive natural circulation. Moreover, the SiC cladding requires heating above 1700 °C to observe failure, thus internal prototypic nuclear heating with radiation effects will be used. Thermal hydraulic analysis with RELAP5-3D (Reactor Excursion and Leak Analysis Program) estimated steam fluxes greater than 50 mg cm −2 s −1 can be achieved. These fluxes are adequate to test Zry cladding according to draft regulatory guides and to test SiC cladding according to past experiments.

Oxidation↗

ECAR-6330 Rev 0 Computational Fluid Dynamics Evaluation of Core Pressure Drop for the Primary Coolant Apparatus Test

PCAT is a thermal-hydraulic test loop for MARVEL reactor. The design gap thickness between the heater rods of PCAT core is 1.0 mm. The heater elements were manufactured within a straightness tolerance for the designed gap thickness, but several elements have been distorted out of tolerance during the welding process. The distortion of heater rods could lead to flow maldistribution and excessive hotspot temperature when the gap between two heater rods is too narrow. Wire-wraps are the spacer devices widely used in the sodium cooled fast reactor system to maintain the design fuel pitch. Generally, a wire spacer can enhance the turbulent heat transfer, but it increases the pressure drop, which is not desirable for a natural-circulation system like PCAT. Therefore, three short wire-wrap spacers per heater have been proposed to contain the core pressure drops and keep the heater-to-heater gap in an acceptable range. The objectives of this ECAR is to evaluate the PCAR core pressure drop with short wire spacers to confirm that the additional pressure drop due to the wire spacer will not disturb the natural circulation of the PCAT.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Preliminary Thermal-Hydraulic Analysis of the UTA–2 Subcritical Linear Accelerator–Driven System

The National Nuclear Security Administration’s mission includes establishing a reliable supply of 99 Mo without highly enriched uranium. Oak Ridge National Laboratory (ORNL) supports this objective through collaborative research and development with industrial partners. Niowave Inc., a current partner, is currently designing a subcritical linear accelerator-driven system (ADS) and preparing for the US Nuclear Regulatory Commission’s licensing process. Niowave’s system has the potential to efficiently supply medical radioisotopes. The technology includes a superconducting electron accelerator and a pile of both natural and low-enriched uranium (LEU) targets. The process fissions uranium and many valuable isotopes can then be extracted from the targets. Niowave is currently iterating through conceptual and detailed design processes for several system sizes. This report discusses UTA–2, which is at the demonstration stage. UTA–2 will validate numerical modeling results with experimental measurements before progressing to the detailed design of UTA–3, the commercial-sized ADS. The thermal-hydraulic behavior of the UTA–2 core design was numerically investigated using STAR-CCM+, as described in this report. STAR-CCM+, a state-of-the-art computational fluid dynamics (CFD) software that was commercially developed by Siemens, has an extensive user base and a set of validation studies. It is also compliant with the American Society of Mechanical Engineers’ Nuclear Quality Assurance 1 standard. Three cases are investigated in this report. Case 1 quantified the temperature field within the UTA–2 assembly and water tank using only conduction as the method of thermal energy transport. This simplified approach was overly conservative and yielded wetted cladding temperatures above the coolant saturation temperature. In this case, the maximum temperature of the wetted cladding surface of the highest power rod exceeded the saturation temperature of water by 63.8°C. Because of the overly conservative approach taken in Case 1 and its negative subcooled margin, buoyancy-driven natural circulation flow physics were implemented in Case 2. Adding coolant motion significantly distributed the thermal energy of the system through convective heat transfer. This relatively small amount of convective heat transfer significantly reduced system temperatures and increased the subcooled margin from –63.8 to 61.3°C. This margin confirmed that no boiling was expected during normal operation of UTA–2 at 230 W. Case 3 had no additional physics models but considered an overpower event during which the power of each LEU and natural uranium rod was at its respective peak values. This resulted in a study with the total assembly power equal to 176% of the nominal power of 230 W considered in Cases 1 and 2. The resulting natural circulation flows were slightly enhanced. The subcooled margin decreased slightly to 46.3°C, which is still a significant margin to local boiling of the water within the tank. This margin confirmed that no boiling was expected during an abnormal operation of UTA–2 at 406 W.

07 ISOTOPE AND RADIATION SOURCES↗

Development of SAM Code Capabilities for Safety Analysis of GCR Air-ingress Events

Air-ingress following a depressurized loss-of-forced-cooling (DLOFC) event is a challenging, multiphysics safety scenario for High-Temperature Gas-Cooled Reactors (HTGRs), involving coupled gas composition transport, buoyancy-driven flow redistribution, graphite oxidation, and structural heat-up. Despite its importance — air ingress is a key scenario identified in the PIRT process for the HTGRs — existing system-level safety codes have lacked the integrated capability to simulate the complete event sequence with high confidence. This report documents the development, validation, and demonstration of three new capabilities in the SAM code to address this gap: (1) a multi-component gas mixture flow model with binary diffusion to track the helium-air composition and its effect on system density and flow; (2) a 0-D graphite oxidation model based on the Roes correlation, including oxygen consumption and exothermic heat release; and (3) an isentropic critical flow model for accurate representation of primary system depressurization through a break. These capabilities are validated against two benchmark experiments. The NSTF heavy-gas ingress experiment validates the multi-component flow model: SAM correctly reproduces the rapid buoyancydriven flow stagnation and subsequent natural circulation recovery driven by composition-dependent density changes. The NACOK graphite oxidation experiment validates the oxidation model: SAM predicts a bottom-level graphite weight loss of 25%, in close agreement with the measured 24%, and reproduces the strong axial nonuniformity and block-geometry dependence of oxidation, at a level comparable to the SPECTRA and TINTE codes. The validated capabilities are then exercised together in an integrated, reactor-scale simulation of a DLOFC air-ingress transient in a simplified HTR-PM pebble-bed reactor. In a single calculation spanning approximately 8 days, SAM reproduces the complete accident sequence: rapid depressurization, densityand diffusion-driven air ingress over ˜15 hours, onset of buoyancy-driven natural circulation, exothermic graphite oxidation with a peak fuel temperature at ˜62 hours, and eventual passive cooldown. These results demonstrate that SAM now provides the nuclear community with a preliminarily validated, modern systemlevel tool for HTGR air-ingress safety analysis, filling a recognized capability gap. Future extensions to broaden species tracking, improve oxidation chemistry, and refine the reactor model are discussed.

Yang, Gang↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

Analysis of Postulated Accident Scenarios for the Transformational Challenge Reactor

The Transformational Challenge Reactor (TCR) is a helium-cooled, yttrium-hydride-moderated reactor that was designed for the U.S. Department of Energy Office of Nuclear Energy. A key objective of the TCR was to employ advanced manufacturing techniques in a nuclear system and demonstrate their potential for revolutionizing the nuclear reactor design process. One purpose of the present work is to demonstrate the safety of the TCR under postulated accidents. Based on RELAP5-3D and COMSOL analyses, the TCR remained below all current safety limits and far below the expected failure limits for the core materials. Another purpose of this work is to provide useful insights and recommendations regarding the application of RELAP5-3D to gas-cooled or other advanced reactors. A novel approach was implemented for simultaneously modeling conduction and radiation in RELAP5-3D, which was found to provide reasonable predictions of radial core, vessel, and ex-vessel heat transfer during postulated events. A multicode approach was also applied, in which high-fidelity COMSOL calculations were used to tune the radial heat transfer parameters in RELAP5-3D. The tuned RELAP5-3D model demonstrated comparable peak temperature predictions as COMSOL, despite a coarse treatment of the core in RELAP5-3D consisting of only two lumped heat structures. This high-fidelity tuning approach enabled enhanced accuracy as well as minimal complexity within the RELAP5-3D model, even for complex fuel geometric designs as in the TCR. Finally, investigations were made into the potential for flow reversal during a pressurized loss-of-forced-flow event in the TCR. The TCR is designed with downward helium flow through the core during normal operation. The RELAP5-3D model predicted that this downward flow would persist, without flow reversal, up to several days after the circulator trip. This was attributed to natural circulation hysteresis effects as have been noted in similar thermofluidic systems. Although flow stagnation and eventual reversal did not lead to unsafe TCR conditions, interesting spatial effects were observed which may have safety relevance for other reactor system designs and coolant types that are designed for downward core flow during normal operation, warranting closer investigation of the flow reversal phenomenon.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SAM Code Enhancements for Modeling of Liquid Metal-Cooled Fast Reactor Concepts

The SAM code is under development and supported by DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. These advanced reactor concepts incorporate novel and improved approaches to achieve safety and economic feasibility. This report summarizes two major efforts in addressing the modeling gaps in SAM for liquid-metal-cooled fast reactor (LMFR) applications, i.e. thermal mixing and stratification phenomena in large pools and corrosion-oxidation of components in flowing lead. A new one-dimensional model for thermal mixing and stratification effects in large pools and enclosures is developed and implemented. Thermal mixing and stratification occur when fluid enters a pool at a temperature different than the bulk fluid itself, a scenario often encountered during transients in pool-type systems. These phenomena are critical for the safety of reactors, impacting phenomena like natural circulation, which is essential for passive cooling. The improved model in SAM addresses limitations of state-of-the-art approaches by combining one-dimensional (1D) channels, representing the coolant jet flow, with lumped-parameter zero-dimensional (0D) pools, representing the rest of coolant in the tank. Energy exchange between the 1D jet and the 0D pools is based on heat transfer correlations calibrated against 3D simulations. It is verified that this model can handle various flow configurations, including hot jets in colder pools, cold jets in hotter pools, and the presence of features like ceilings, free surfaces, and obstacles. Additionally, validation against experimental data demonstrates the ability of the model to capture mixing and stratification effects in a wide range of conditions. The flexibility and improved accuracy of the new model make it a valuable tool for reactor safety analysis, allowing for the simulation of different geometries encountered in advanced reactors. A system-level corrosion modeling capability is developed and implemented in SAM to support Lead Fast Reactor (LFR) development. Although the initial focus of this capability will be on LFR application, this can later be expanded to include other liquid metals such as Lead-Bismuth Eutectic (LBE) and PbLi. This report summarizes the common corrosion mitigation strategies and outlines the progress on implementing and validating a corrosion-oxidation model in SAM. Verification and validation of the corrosion-oxidation portion of the model was performed using analytical solution and measured data from samples tested in the non-isothermal pumped lead loop at IPPE Obninsk. The iron transport and corrosion/precipitation portion of the model was assessed using an analytical model and measured corrosion depths from a natural convection lead loop experiment performed at CEA. It is demonstrated that the model implemented in SAM performed well in these assessments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: An experimental study

The objective of the present experimental study is to investigate the effect of inlet throttling on the thermohydraulic stability of a large scale water-based Reactor Cavity Cooling System (RCCS). The test was performed using the water-based Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne, which represented a ½ axial scale and 12.5° sector slice of the full scale Framatome 625 MW t SC-HTGR RCCS concept. A two-phase steady state was first established through direct condensate refill, followed by increased inlet throttling over 10 stages, corresponding to a loss coefficient K over the range of 0.05–653. With the inlet throttling gradually increased, the system experienced a unique transition process between stabilization and destabilization. Through a stability analysis, three instability mechanisms were identified in the present test, including a compound mechanism due to both natural circulation oscillations (NCOs) and density wave oscillations (DWOs), Type-II DWOs, and geysering.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗