Search NASA⌕ Search

SEARCH · Search NASA

Results for “negative sequence control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ranking Biological Features in Soil-Based Microbial Multi-Omics Data with Integration Modeling

Distinguishing the most important features (e.g. proteins, metabolites, etc.) per group (e.g. control and treatment) is a critical challenge in feature-rich multi-omics experiments, especially in soil data. Traditional feature identification and ranking approaches, such as differential expression, are based on single omics and thus not directly translatable to multi-omics experiments. Here, 5 multi-omics integration models (DIABLO, JACA, MOFA, MultiMLP, and SLIDE) that were not explicitly built for soil data applications were tested using a soil-based multi-omics experiment. The data were obtained from an experimental setup of an autoclaved soil system inoculated with 8 bacteria and using chitin as the carbon source and including samples collected at 0- (control), 4-, 8-, and 12-weeks post-inoculation. The omics data included metaproteomics, 16S rRNA sequencing, and LC-MS/MS metabolomics (in positive and negative mode). Each multi-omics integration model was implemented, and top features were compared to differential univariate statistics per omic type, demonstrating that integration approaches cut the potential number of top features from 2957 identified by differential statistics to 13-224 (a 99.6% to 92.4% reduction). Interestingly, most top features across integration models were not shared; though, scaling and averaging ranks across models shared similar patterns. This work highlights the usefulness of multi-omics integration models in soil-based microbial studies and the power of using multiple integration models together to interpret results.

54 ENVIRONMENTAL SCIENCES↗

Solar energy facility at North Hampton Recreation Center, Dallas, Texas

The solar energy facility located at the North Hampton Park Recreation and Health Center, Dallas, Texas is presented. The solar energy system is installed in a single story (two heights), 16,000 sq ft building enclosing a gymnasium, locker area, and health care clinic surrounded by a recreational area and athletic field. The solar energy system is designed to provide 80 percent of the annual space heating, 48 percent of the annual space cooling, and 90 percent of the domestic hot water requirements. The system's operation modes and performance data acquisition system are described. The system's performance during the months of June, July, August, September, and October of 1979 are presented and show a negative savings of energy. Experience to date indicates however that the system concept has promise of acceptable performance. It is concluded that if proper control and sequencing components was maintained, then the system performance would improve to an acceptable level.

Source record↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Coordinate generation with precise controls over mesh properties

Powerful local controls have been developed for mesh generation with the class of multisurface coordinate transformations. The controls come from local piecewise linear interpolants, and the resulting coordinates have continuous first derivatives. At the boundaries, the mesh controls provide the capability of joining distinct coordinate systems together with continuous derivatives. Away from boundaries, a local region can be given a particular mesh form to model internal objects or to simplify a problem. Applications of the controls are illustrated with a sequence of two-dimensional examples. For simplicity, each is generated about a NACA0012 airfoil which is of unit length and with leading edge pointed in a negative x-direction.

Eiseman, P. R.↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

An Admittance-Based Protection Scheme for Microgrids

This paper presents a novel directional protection scheme to address the unique challenges associated with protection during unbalanced faults in a distribution system with high penetration of inverter-based resources. The scheme is based on a superimposed negative sequence admittance method. A coordination approach using a unique inverse-time undervoltage element is also presented. An analysis of the scheme, the detection criteria and the coordination method are performed. Also the impact of inverter-control on the scheme is discussed. Results from extensive simulation using MATLAB/Simulink are presented to show a selective and reliable response of the scheme to unbalanced faults

Opoku, Kwasi↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

Detection of Apparent Early Rabies Infection by LN34 Pan-Lyssavirus Real-Time RT-PCR Assay in Pennsylvania

The Pennsylvania Department of Health Bureau of Laboratories (PABOL) tested 6855 animal samples for rabies using both the direct fluorescent antibody test (DFA) and LN34 pan-lyssavirus reverse transcriptase quantitative PCR (RT-qPCR) during 2017–2019. Only two samples (0.03%) were initially DFA negative but positive by LN34 RT-qPCR. Both cases were confirmed positive upon re-testing at PABOL and confirmatory testing at the Centers for Disease Control and Prevention by LN34 RT-qPCR and DFA. Rabies virus sequences from one sample were distinct from all positive samples processed at PABOL within two weeks, ruling out cross-contamination. Levels of rabies virus antigen and RNA were low in all brain structures tested, but were higher in brain stem and rostral spinal cord than in cerebellum, hippocampus or cortex. Taken together, the low level of rabies virus combined with higher abundance in more caudal brain structures suggest early infection. These cases highlight the increased sensitivity and ease of interpretation of LN34 RT-qPCR for low positive cases.

59 BASIC BIOLOGICAL SCIENCES↗

Chip Advancer For GPS Receiver

Instrument errors made negligible. For each integration interval, both delay and rate of change of delay initialized to small fraction of chip - for example, to order of 10 to the negative 7th power - thereby making feedback control and extraction of delay highly accurate and flexible. With appropriate selection of sampling rate relative to chip rate, commensurability errors reduced to extremely small levels. In Global Positioning System (GPS) receiver, pseudorandom code sequence generated by simple digital logic incorporating effects of time, delay, and rate of change of delay. Flexibility in starting time and sum interval very useful in aligning correlation interval with beginnings and endings of data bits.

Meehan, Thomas K.↗

Electro-optic Q-switch

An electro-optic Q-switch for generating sequence of laser pulses was disclosed. The Q-switch comprises a quadratic electro-optic material and is connected with an electronic unit generating a radio frequency wave with positive and negative pulses alternatively. The Q-switch is controlled by the radio frequency wave in such a way that laser pulse is generated when the radio frequency wave changes its polarity.

Zou, Yingyin↗

In-Space Crew-Collaborative Task Scheduling

For all past and current human space missions, the final scheduling of tasks to be done in space has been devoid of crew control, flexibility, and insight. Ground controllers, with minimal input from the crew, schedule the tasks and uplink the timeline to the crew or uplink the command sequences to the hardware. Prior to the International Space Station (ISS), the crew could make requests about tomorrow s timeline, they could omit a task, or they could request that something in the timeline be delayed. This lack of control over one's own schedule has had negative consequences. There is anecdotal consensus among astronauts that control over their own schedules will mitigate the stresses of long duration missions. On ISS, a modicum of crew control is provided by the job jar. Ground controllers prepare a task list (a.k.a. "job jar") of non-conflicting tasks from which jobs can be chosen by the in space crew. Because there is little free time and few interesting non-conflicting activities, the task-list approach provides little relief from the tedium of being micro-managed by the timeline. Scheduling for space missions is a complex and laborious undertaking which usually requires a large cadre of trained specialists and suites of complex software tools. It is a giant leap from today s ground prepared timeline (with a job jar) to full crew control of the timeline. However, technological advances, currently in-work or proposed, make it reasonable to consider scheduling a collaborative effort by the ground-based teams and the in-space crew. Collaboration would allow the crew to make minor adjustments, add tasks according to their preferences, understand the reasons for the placement of tasks on the timeline, and provide them a sense of control. In foreseeable but extraordinary situations, such as a quick response to anomalies and extended or unexpected loss of signal, the crew should have the autonomous ability to make appropriate modifications to the timeline, extend the timeline, or even start over with a new timeline. The Vision for Space Exploration (VSE), currently being pursued by the National Aeronautics and Space Administration (NASA), will send humans to Mars in a few decades. Stresses on the human mind will be exacerbated by the longer durations and greater distances, and it will be imperative to implement stress-reducing innovations such as giving the crew control of their daily activities.

Jaap, John↗

Phasor-Domain Modeling of Inverter Based Resources Considering Unbalanced Grid Faults

A significant increase in inverter-based distributed energy resources (DERs) is expected in distribution systems of the near future. The latest phasor modeling approach of DERs with emerging control technologies can capture relevant dynamics in large-scale three-phase distribution systems with unbalanced construction. However, there is a lack of appropriate phasor models to deal with unbalanced fault scenarios. As such, this paper describes per-phase phasor modeling approach appropriate for unbalanced grid disturbance studies in distribution systems with high penetration of DERs. The overall modeling performance of representative DERs is simulated in phasor domain GridLAB-D environment and validated against controller hardware-in-the loop (CHIL) testing or electromagnetic transient (EMT) based switching model simulation in PSCAD with test cases including different unbalanced grid faults. The high accuracy retained from the simulation verifies the effectiveness of the proposed phasor modeling approach considering interactions between positive and negative sequence signals.

Chen, Zhe↗

ISS And Space Environment Interactions Without Operating Plasma Contactor

The International Space Station (ISS) will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur. The details of interaction effects on spacecraft have not been addressed until driven by design. This was true for ISS. If the structure is allowed to float highly negative impinging ions can sputter exposed conductors which can degrade the primary surface and also generate contamination due to the sputtered material. Arcing has been known to occur on solar arrays that float negative of the ambient plasma. This can also generate electromagnetic interference and voltage transients. Much of the ISS structure and pressure module surfaces exposed to space is anodized aluminum. The anodization thickness is very thin to provide the required solar absorptance and emittance. For conditions where ISS structure can charge negative a large percentage of the array voltage, the dielectric strength of this layer is low, and dielectric breakdown (arcing) can occur. The energy stored capacitively in the structure can be delivered to the arc. The mechanisms by which this energy is delivered and how much of the energy is available hasn't been fully quantified. Questions have been raised regarding the possibility of whether a sustained arc might result due to current collected by the solar arrays from local plasma. It was postulated that even if dielectric breakdown didn't occur, impacts due to micrometeoroids and space debris could penetrate thin layers of dielectric on ISS and initiate an arc due to the coupling provided by the dense local plasma produced by the impact. This was proven in experiments conducted jointly by MSFC and Auburn University. A target chamber with a simulated ionospheric plasma and a biased, anodized aluminum plate and a 1-microfarad capacitor was used. The plate was then impacted by 75-micron particles accelerated to orbital velocity. Arc discharges were sustained for higher voltages but a threshold appears below which no discharge was initiated. Most items without an exposed power system will float electrically near the local plasma potential. This is true of the Space Shuttle, an Astronaut on EVA, and similar items. The structure of ISS might be at a large negative voltage. Therefore, capacitively stored energy can be transferred during docking, installing external boxes and equipment and Astronaut contact with ISS structure. The circumstances of when this can happen and the resulting effects are evaluated in this study. Also, a crewmember on EVA might be in the vicinity of an arc. All safety aspects of such an encounter including charging, molten particles from the arc site and EMI have been evaluated. This paper will report on the total results of this study focussed on the 4A configuration, scheduled to be complete in November, 2000. Interactions such as arcing, debris induced arcs, sustained arcs, sputtering, contamination from sputtering and arcing, docking interactions and Astronaut safety issues will all be addressed.

Carruth, M. R., Jr.↗

Prescribed fire selects for a pyrophilous soil sub‐community in a northern California mixed conifer forest

Abstract Prescribed fire is a critical strategy for mitigating the effects of catastrophic wildfires. While the above‐ground response to fire has been well‐documented, fewer studies have addressed the effect of prescribed fire on soil microorganisms. To understand how soil microbial communities respond to prescribed fire, we sampled four plots at a high temporal resolution (two burned, two controls), for 17 months, in a mixed conifer forest in northern California, USA. Using amplicon sequencing, we found that prescribed fire significantly altered both fungal and bacterial community structure. We found that most differentially abundant fungal taxa had a positive fold‐change, while differentially abundant bacterial taxa generally had a negative fold‐change. We tested the null hypothesis that these communities assembled due to neutral processes (i.e., drift and/or dispersal), finding that >90% of taxa fit this neutral prediction. However, a dynamic sub‐community composed of burn‐associated indicator taxa that were positively differentially abundant was enriched for non‐neutral amplicon sequence variants, suggesting assembly via deterministic processes. In synthesizing these results, we identified 15 pyrophilous taxa with a significant and positive response to prescribed burns. Together, these results lay the foundation for building a process‐driven understanding of microbial community assembly in the context of the classical disturbance regime of fire.

Microbiology↗