Overview of the Neutron Radiography Reactor (NRAD) for Neutron Imaging and In-Core Experiment Capabilities at Idaho National Laboratory

NRAD is a 250-kilowatt TRIGA research reactor that first went online at INL in 1977. (TRIGA stands for Training, Research, Isotopes, General Atomics.) Historically, NRAD was utilized as a neutron radiography reactor that provides comprehensive, non-destructive information about the internal condition of irradiated nuclear fuel. Idaho National Laboratory (INL) has multiple nuclear fuels research and development programs that routinely evaluate irradiated fuels using neutron radiography at NRAD. In recent years, NRAD has gone through a transformation from the single purpose radiography reactor for which it was designed into a multipurpose research reactor, and expanding its in-core irradiation capabilities to support a broader mission for the US Department of Energy (DOE) Nuclear Energy (NE) programs, Basic Energy Science (BES) Programs, as well as Fusion Energy programs. NRAD is a designated user facility under the DOE Nuclear Science User Facility (NSUF) program, and is available for access for general public via a competitive proposal process. More information about NSUF and NRAD are available from the website: https://nsuf.inl.gov/Home/Facility/654.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of an Out-Of-Pile Experimental Facility to Demonstrate the Feasibility of In Situ Thermal Conductivity Measurements of Nuclear Fuels Under Irradiation

There is substantial merit in quantifying nuclear fuel performance under irradiation. At Oak Ridge National Laboratory (ORNL), the MiniFuel irradiation platform has become the primary test vehicle for conducting separate-effects fuel performance irradiation experiments. The MiniFuel experiment is a passively controlled capsule design deployed in the High Flux Isotope Reactor (HFIR) through which fuel performance data is collected post-irradiation. Separate effects fuels irradiation capabilities are being expanded at ORNL by developing instrumented capsule designs that aim to capture fuel performance phenomena in-situ. One such capsule will specifically target fuel specimen thermal conductivity changes as a function of fuel burnup. Due to the complexity of making this measurement on nuclear fuel in-pile, this paper describes the necessary out-of-pile testing conducted on the thermal conductivity capsule (TCC) design. The measurement is ascertained via a thermopile system with heat transferred unidirectionally through a surrogate fuel specimen sandwiched between two conductive materials. The capsules investigated in this study are representative of the in-pile design, with the primary departure from irradiation conditions being the distribution of heat generation within the capsule. In the out-of-pile experiment, an external heater was used to drive heat through the conductive slug materials and into the specimen. This paper expounds the design of the out-of-pile experimental system and the thermal conductivity measurement technique. Predictive models used to determine the sensitivity of the measurement to variables governing thermal contact conductance between the specimen and slug materials and to predict experimental results are also described. Data from the out-of-pile experiment will be used to validate the readiness of the design for insertion into HFIR for irradiation.

Parker, Trevor [ORNL]↗

Research on radiation induced laser plasmas

The development of high power nuclear pumped lasers is discussed. The excitation mechanism of continuous wave (CW) HeNe nuclear pumped lasers is studied and a CO2 nuclear pumped laser is used to demonstrate the CW output in the order of watts. The assumption that high power densities are only achievable by volume fission fragment sources is used to identify laser gases which are compatible with UF6 by excited states lifetime measurements. The examination of Xe2, XeF, and KrF under nuclear irradiation to determine if they are good candidates for nuclear-pumped lasers is described.

Schneider, R. T.↗

Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies

Testing and qualification of advanced nuclear fuels involves an iterative process of prototyping, in-pile irradiation testing, and in-situ or ex-situ examination. Fuel restructuring and fission product migration during burnup are among the most important aspects of fuel evolution that affect several important performance characteristics such as heat removal, accident tolerance, and fission product retention. Pool-side non-destructive characterization techniques provide fuel developers with tools to understand fuel evolution at different points of burnup. A design for a compact, submersible, and multi-modal gamma-ray tomography system for imaging irradiated nuclear fuel is presented here. Detector selection, collimator geometry and fabrication, mechanical design, imaging protocol and acquisition speed are discussed. Modeling calculations show that sub-millimeter resolution can be achieved in both transmission computed tomography images as well as in emission computed tomography images in a matter of hours. Several design compromises and fabrication challenges are discussed which should be taken into consideration for future submersible gamma-ray tomography instruments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A novel method for quantifying irradiation damage in nuclear graphite using Raman spectroscopy

Raman spectroscopy has long been used in studying irradiation damage in carbon/graphite materials. It is however unclear if the measurements from different types of materials are directly comparable. Further, decoupling the contribution from irradiation temperature and fluence to the total damage in nuclear graphite possessing irradiation damage gradient is currently not readily feasible as it requires a complete set of test reactor irradiation experiments over the relevant temperature and fluence range. A novel methodology has therefore been proposed and developed to quantify total irradiation damage evolution at crystal level based on graphite Raman G-band position shift. Specifically, G-band positions derived from a large number of spectra collected from the fractured surface of microfine-grained POCO ZXF-5Q graphite possessing proton irradiation damage gradient were plotted with open literature Raman data on HOPG, BEPO (AXGP graphite), PCEA and IG-110 graphite as a function of dpa. The total damage level within 2σ beam radius in this POCO graphite was estimated to be equivalent to ~2–5 dpa at ~350–370 °C. Derived G-band positions were then mapped to the three-stage amorphization trajectory model indicating beam centre area has entered the second stage, i.e., transitioning from nanocrystalline graphite into amorphous carbon. G-band position relative shift (ΔG) curve with a ‘turn-around’ peak as a function of total damage can be used for in-service lifetime prediction. Importantly, the developed methodology has the potential to ‘unify’ total damage levels across different grades of nuclear graphite caused by ion, neutron and proton irradiation at different temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo neutronics benchmarks on nuclear fuel depletion: A review

Monte Carlo (MC) neutronics codes are used widely for academic and industrial needs. Several schemes of coupling MC neutronics code with isotope generation and depletion code exist, which are used for performing nuclear fuel depletion simulations. These simulations can estimate the inventory of isotopes in neutron irradiated nuclear reactor fuel. However, the accuracy of these simulations shall be validated through experiments. MC codes are seldom validated by isotopic benchmarks compared to criticality benchmarks. This work compiles and analyzes the fuel depletion benchmarks and validations used to analyze the performance of MC-based fuel depletion neutronics codes. Analyses of these benchmarks and validations showed that the computed concentrations of 133 Cs, 135 Cs, 137 Cs, 148 Nd, 239 Pu, 240 Pu, and 241 Pu in the irradiated fuel by the depletion codes agreed with the measured values within 10% error. However, the computed concentrations of 125 Sb, 242 Cm, 243 Cm, 244 Cm, 245 Cm, and 246 Cm had errors more than 15% compared to the measured values. As a result, Ventina depletion code showed the most accurate predictions for the greatest number of isotope concentrations compared to ORIGEN2 and CINDER90.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensor for Reactor Experiments

This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation and demonstration of the AEFC as a practical safeguards tool for inventory verification

The Advanced Experimental Fuel Counter (AEFC) is a nondestructive assay (NDA) instrument designed to determine the residual fissile mass in irradiated fuel assemblies for safeguards verification purposes. This is done by actively interrogating an assembly with a neutron source and measuring the total (Singles) and correlated (Doubles) neutron count rates resulting from induced fissions in the irradiated nuclear fuel and relating those rates to the residual fissile mass using calibration curves. Comprehensive NDA measurements of the irradiated fuel inventory at Israeli Research Reactor 1 (IRR-1) were taken with the AEFC to validate a set of previously developed calibration curves. During the campaign, measurements were acquired of 32 standard fuel assemblies and three control assemblies in just nine days. This is a significant majority of the research reactor's irradiated fuel inventory and the largest data set gathered by the AEFC to date. Many of the fuel assemblies measured during the campaign had much shorter cooling times than those assemblies previously measured with the instrument. Calibration curves developed from previous AEFC deployments were used to determine the residual 235 U mass in the measured standard fuel assemblies. The results of the campaign demonstrated that the AEFC can be used to estimate the 235 U mass remaining in a large number of irradiated fuel assemblies with 1%–5% uncertainty in a reasonable amount of time despite operating in a high dose environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development and Test Results of Thermocouples Used in the TRISO-Fuel Irradiation Experiment AGR-5/6/7

High-temperature gas reactor irradiation experiments create unique challenges for thermocouple-based temperature measurements. High-temperature industrial thermocouples suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. For lower-temperature applications, Type K and Type N thermocouples are affected by neutron irradiation only to a limited extent. But until recently, the use of these nickel-based thermocouples was limited when the temperature exceeded 1050°C due to drift related to phenomena other than nuclear irradiation. Certain portions of the AGR-5/6/7 experiment experienced temperatures higher than any of the previous AGR tests, up to 1500°C. Recognizing the limitations of existing thermometry to measure such high temperatures, the sponsor of the AGR-5/6/7 test supported a development and testing program for thermocouples capable of low-drift operation at temperatures above 1100°C. This program included additional development of high-temperature irradiation-resistant thermocouples based on molybdenum/niobium thermoelements, which have been studied at Idaho National Laboratory since circa 2004. A step change in accuracy and long-term stability of this thermocouple type was achieved as part of the AGR-5/6/7 thermometry development program. Additionally, long-term testing (7000+ h) at 1250°C of Type N thermocouples utilizing a customized sheath developed at the University of Cambridge has been completed with excellent low-drift results. The results of this testing as well as testing of the improved high-temperature irradiation-resistant design are reported herein. Both the improved high-temperature irradiation-resistant and the Cambridge Type N thermocouple types were incorporated into the AGR-5/6/7 test, which began irradiation in February 2018 and was completed in July 2020. Finally, a summary of the performance of the thermocouples incorporated into the AGR-5/6/7 test is included herein.

In-pile instrumentation↗

Suppression of Helium Induced Cracking in Laser Repair Welding of Highly Irradiated Stainless Steels

Welding repair of irradiated nuclear reactor materials such as austenitic stainless steels used for the reactor internals has been challenging due to irradiation generated helium in the material matrix over an extended period of time. In this study, improved laser welding techniques, including the novel Auxiliary Beam Stress Improved (ABSI) technique that proactively manages the stresses during laser repair welding is investigated to substantially reduce or avoid the occurrence of intergranular helium-induced cracking (HeIC). Here, laser weld cladding, with and without ABSI technique, was applied to deposit weld metal on irradiated stainless steel (Type 304 L) blocks with various helium concentrations up to approximately 20 atomic parts per million (appm). Welded samples were cross-sectioned and analyzed using optical and electron microscopes. It was found that, with the improved laser welding techniques, no macroscopic (millimeter-sized) cracks were observed in any of the samples. Microscopic (less than 50 μm) cracks were present in the heat affected zone. Statistical analysis on the sample with the highest helium concentration (~20 appm) reveals that the ABSI technique could effectively reduce the size and amounts of microscopic cracks.

36 MATERIALS SCIENCE↗

Proliferation Detection via Acoustic Monitoring of Pyroprocessing Equipment and Related Systems

In support of nuclear safeguards and nonproliferation, this effort is leveraging acoustic and seismic sensors to advance detection of pyroprocessing activities. Pyroprocessing, or electrochemical processing, is a method of separating irradiated nuclear fuel into its actinide and fission product components, enabling the reuse of fuel materials and reducing the radiotoxicity of the remaining waste. Verification and accountability in the process poses several challenges because of the high radiation environment and the presence of material holdup through the facility. Irregular or unaccounted-for equipment operation can signify diversion or misuse of critical materials. Acoustic and seismic sensors offer the capability to identify periods of equipment operation and help verify adherence to accountancy records.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument

Here, the design of a submersible, gamma-ray tomography system for imaging irradiated nuclear fuel is described. The system—named Fuel Interrogation and Examination using Submersible Tomography Analysis (FIESTA) Mk. II—is a variation on a previous Mk. I I design, which was developed to non-destructively image fuel capsules irradiated in the Advanced Test Reactor at the Idaho National Laboratory. The FIESTA system uses a combination of transmission computed tomography and emission computed tomography to image the restructuring and fission product migration at different points of burnup. Changes made to FIESTA Mk. I reflect the revised design requirements and a need to reduce background noise, largely originating from downscattered photons from fuel and transmission source. The computational design and radiation transport simulations are described.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗