Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cherenkov-dE/dx-range measurements on cosmic ray iron group nuclei

A balloon experiment which combined a large area plastic detector unit with electronic dE/dx-C data is presented. The correlation of the electronic data with the range data of the plastic detector stack was achieved by rotating plastic detector disks which provided in this way the passive plastic detector with an incorporated time determination. The constant flux of cosmic ray particles with charge Z greater than two was used to gauge the time resolving system. Stopping cosmic ray iron group nuclei in the energy range 400 to 700 MeV/nuc are identified using their electronic scintillator and Cherenkov signals and their etch conelengths and range data. The precise knowledge of the particle's trajectory proposes refined pathlength corrections to the electronic data.

Sermund, G.↗

Calibration tests on magnetic tape lightning current detectors

The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

Crouch, K. E.↗

Enabling High Performance Instruments for UV Astronomy and Space Exploration with ALD

Benefits of Atomic Layer Deposition (ALD) for UV instruments and application are: (1) Ultrathin, highly conformal, and uniform films over arbitrarily large surface area (2) High quality films (density, roughness, conductivity, etc.) (3) Angstrom level control of stoichiometry, interfaces, and surface properties (3a) Multilayer nanolaminates/nanocomposites (3b) Low temperature surface engineering UV flight applications enabled by ALD. (1) Anti -reflective coatings/Mirrors/Filters/Optics for UV/Vis/NIR Detectors (2) Surface Passivation for III -N detectors

quantum efficiency↗

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

The CHANDRA X-Ray Observatory: Thermal Design, Verification, and Early Orbit Experience

The CHANDRA X-ray Observatory (formerly AXAF), one of NASA's "Great Observatories" was launched aboard the Shuttle in July 1999. CHANDRA comprises a grazing-incidence X-ray telescope of unprecedented focal-length, collecting area and angular resolution -- better than two orders of magnitude improvement in imaging performance over any previous soft X-ray (0.1-10 keV) mission. Two focal-plane instruments, one with a 150 K passively-cooled detector, provide celestial X-ray images and spectra. Thermal control of CHANDRA includes active systems for the telescope mirror and environment and the optical bench, and largely passive systems for the focal plans instruments. Performance testing of these thermal control systems required 1-1/2 years at increasing levels of integration, culminating in thermal-balance testing of the fully-configured observatory during the summer of 1998. This paper outlines details of thermal design tradeoffs and methods for both the Observatory and the two focal-plane instruments, the thermal verification philosophy of the Chandra program (what to test and at what level), and summarizes the results of the instrument, optical system and observatory testing.

Boyd, David A.↗

Radiation measurements in low Earth orbit: U.S. and Russian results

The radiation environment in low-Earth orbital flights is complex. It is strongly influenced by altitude, orbital inclination, time within a given solar cycle, flight duration, and shielding configuration. At any specified shielded location, both primary and secondary particles generated by nuclear interactions of primary particles with spacecraft structure are present. In addition, there are atmospheric secondary albedo protons and neutrons. No single detector can adequately measure this complex radiation field, and measurements of very high linear energy transfer target fragmentation products are particularly difficult. Crew radiation exposure have exclusively been measured using passive thermoluminescent detectors (TLDs). The cosmonaut exposures on the Mir station, uncorrected for the TLD inefficiency and neutron contribution, have varied from a low of 2.43 cGy to a high of 8.70 cGy. These correspond to dose rates of 144 microGy d(-1) to 468 microGy d(-1). These are consistent with rates observed by the D2 ion-chamber. Using the rates measured by the D1 chamber, dose rates under 4 cm of water vary from about 60 microGy d-1 to about 350 microGy d(-1). There is variation of about a factor of two between the dose rates at various locations in the same module. There is also a variation of dose rates of about a factor two between various modules. The highest astronaut dose for a Shuttle flight (STS-82) was 3.205 cGy with a dose rate of 3,221 microGy d(-1). Neutron contribution could be 36 +/- 15% of the astronaut charged particle dose equivalent. East-West asymmetry of dose rate is significant for spacecrafts that fly in an fixed altitude, such as the International Space Station.

NASA Center JSC↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

Radiation Tests of the Extravehicular Mobility Unit Space Suit for the International Space Station Using Energetic Protons

Measurements using silicon detectors to characterize the radiation transmitted through the EMU space suit and a human phantom have been performed using 155 and 250 MeV proton beams at LLUMC. The beams simulate radiation encountered in space, where trapped protons having kinetic energies on the order of 100 MeV are copious. Protons with 100 MeV kinetic energy and above can penetrate many centimeters of water or other light materials, so that astronauts exposed to such energetic particles will receive doses to their internal organs. This dose can be enhanced or reduced by shielding - either from the space suit or the self-shielding of the body - but minimization of the risk depends on details of the incident particle flux (in particular the energy spectrum) and on the dose responses of the various critical organs. Data were taken to characterize the beams and to calibrate the detectors using the beam in a treatment room at LLUPTF, in preparation for an experiment with the same beams incident on detectors placed in a human phantom within the EMU suit. Nuclear interactions of high-energy protons in various materials produce a small flux of highly ionizing, low-energy secondary radiation. Secondaries are of interest for their biological effects, since they cause doses and especially dose-equivalents to increase relative to the values expected simply from ionization energy loss along the Bragg curve. Because many secondaries have very short ranges, they are best measured in passive track detectors such as CR-39. The silicon detector data presented here are intended to supplement the CR-39 data in regions where silicon has greater sensitivity, in particular the portion of the LET spectrum below 5 keV/micron. The results obtained in this study suggest that optimizing the radiation shielding properties of space suits is a formidable task. The naive assumption that adding mass can reduce risk is not supported by the data, which show that reducing the dose delivered at or near the skin by low-energy particles may increase the dose delivered by energetic particles to points deeper in the body.

Zeitlin, C.↗

Toward Ultra‐High‐Quality‐Factor Wireless Masing Magnetic Resonance Sensing

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1- 13 C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, in this study, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22-fold (to 1,670) via parametric pumping. This active-feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T 2 * of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coincidence measurements of radioxenon using passive implemented planar silicon (PIPS) detector

The Comprehensive Test Ban Treaty (CTBT) bans nuclear weapons testing and establishes the International Monitoring System (IMS) for the purpose of treaty verification. IMS is a detector network that confirms that global nuclear activity is peaceful in nature. These detector systems use β-γcoincidence measurements to characterize atmospheric samples containing radioxenon isotopes. The goal of this work is to use the system consisting of two sodium iodide detectors and two PIPSbox detectors to characterize isotopically pure samples of 131m Xe, 133m Xe, 133 Xe, and 135 Xe via β, γ, and β-γ coincidence measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Charge collection in h -BN neutron detectors at elevated temperatures

Many of the neutron detector applications are in the environments with harsh conditions such as high temperatures. We report here the measurements of charge collection parameters of hexagonal boron nitride (h-BN) detectors at elevated temperatures, including the electron mobility-lifetime product (μτ) and surface recombination field (s/μ). It was found that μτ is increased, while s/μ is decreased as temperature increases. The temperature dependence of the surface recombination field (s/μ) revealed that electrons trapped in the surface states tend to thermally activate to the bulk region at higher temperatures with an activation energy of about 0.22 eV, leading to a reduction in the density of the charged surface states at elevated temperatures. Consequently, the charge collection efficiency is enhanced at elevated temperatures due to a reduced surface recombination field and increased electron mobility-lifetime product. The results suggested that h-BN neutron detectors are favorable for high temperature operation.

47 OTHER INSTRUMENTATION↗

Sweep frequency detector

Sweep detector or passive spectrum analyzer provides a positive monitoring of the bandwidth of the input amplifier of a tracking receiver. Used with an oscilloscope, it provides a visual display of a microwave amplifier bandpass.

Clauss, R. C.↗

Development of a high capacity bubble domain memory element and related epitaxial garnet materials for application in spacecraft data recorders. Item 2: The optimization of material-device parameters for application in bubble domain memory elements for spacecraft data recorders

Bubble domain materials and devices are discussed. One of the materials development goals was a materials system suitable for operation of 16 micrometer period bubble domain devices at 150 kHz over the temperature range -10 C to +60 C. Several material compositions and hard bubble suppression techniques were characterized and the most promising candidates were evaluated in device structures. The technique of pulsed laser stroboscopic microscopy was used to characterize bubble dynamic properties and device performance at 150 kHz. Techniques for large area LPE film growth were developed as a separate task. Device studies included detector optimization, passive replicator design and test and on-chip bridge evaluation. As a technology demonstration an 8 chip memory cell was designed, tested and delivered. The memory elements used in the cell were 10 kilobit serial registers.

Besser, P. J.↗

A rocket ozonesonde for geophysical research and satellite intercomparison

The in-situ rocketsonde for ozone profile measurements developed and flown for geophysical research and satellite comparison is reviewed. The measurement principle involves the chemiluminescence caused by ambient ozone striking a detector and passive pumping as a means of sampling the atmosphere as the sonde descends through the atmosphere on a parachute. The sonde is flown on a meteorological sounding rocket, and flight data are telemetered via the standard meteorological GMD ground receiving system. The payload operation, sensor performance, and calibration procedures simulating flight conditions are described. An error analysis indicated an absolute accuracy of about 12 percent and a precision of about 8 percent. These are combined to give a measurement error of 14 percent.

Hilsenrath, E.↗

Radiation measurements aboard Spacelab 1

The radiation environment inside Spacelab 1 was measured by a set of passive radiation detectors distributed throughout the volume inside the module, in the access tunnel, and outside on the pallet. Measurements of the low linear energy transfer (LET) component obtained from the thermoluminescence detectors ranged from 102 to 190 millirads, yielding an average low LET dose rate of 11.2 millirads/day inside the module, about twice the low LET dose rate measured on previous flights of the Space Shuttle. Because of the higher inclination of the orbit (57 versus 28.5 deg for previous Shuttle flights), substantial fluxes of highly ionizing high charge and energy galactic cosmic ray particles were observed, yielding an overall average mission dose-equivalent of about 150 millirems, more than three times higher than that measured on previous Shuttle missions.

Benton, E. V.↗

Radiation mapping on Spacelab 1: Experiment no. INS006

The first attempt at mapping the radiation environment inside Spacelab is described. Measurements were made by a set of passive radiation detectors distributed throughout the volume inside the Spacelab 1 module, in the access tunnel and outside on the pallet. Measurements of the low linear energy transfer (LET) component obtained from the TLD thermoluminescent detectors (TLD) ranged from 92 to 134 mrad, yielding an average low LET dose rate of 10.0 mrads/day inside the module. Because of the higher inclination orbit, substantial fluxes of highly ionizing (HZE particles) high charge and energy galactic cosmic rays were observed for the first time on an STS flight, yielding an overall average mission dose-equivalent of 295 mrem, or 29.5 mrem/day, which is about three times higher than that measured on previous STS missions. Little correlation is found between measured average dose rates or HZE fluences and the estimates shielding throughout the volume of the module.

Benton, E. V.↗

Cockpit display of hazardous wind shear information

Information on cockpit display of wind shear information is given in viewgraph form. Based on the current status of windshear sensors and candidate data dissemination systems, the near-term capabilities for windshear avoidance will most likely include: (1) Ground-based detection: TDWR (Terminal Doppler Weather Radar), LLWAS (Low-Level Windshear Alert System), Automated PIREPS; (2) Ground-Air datalinks: Air traffic control voice channels, Mode-S digital datalink, ACARS alphanumeric datalink. The possible datapaths for integration of these systems are illustrated in a diagram. In the future, airborne windshear detection systems such as lidars, passive IR detectors, or airborne Doppler radars may also become available. Possible future datalinks include satellite downlink and specialized en route weather channels.

Wanke, Craig↗

LDEF Experiment P0006 Linear Energy Transfer Spectrum Measurement (LETSME) quick look report

A preliminary analysis of the various passive radiation detector materials included in the P0006 LETSME experiment flown on LDEF (Long Duration Exposure Facility) is presented. It consists of four tasks: (1) readout and analysis of thermoluminescent detectors (TLD); (2) readout and analysis of fission foil/mica detectors; (3) readout and analysis of (6)LiF/CR-39 detectors; and (4) preliminary processing and readout of CR-39 and polycarbonate plastic nuclear track detectors (PNTD).

Source record↗