Search NASA⌕ Search

SEARCH · Search NASA

Results for “pipeline corrosion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Solar Electricity

ARCO Solar manufactures PV Systems tailored to a broad variety of applications. PV arrays are routinely used at remote communications installations to operate large microwave repeaters, TV and radio repeaters rural telephone, and small telemetry systems that monitor environmental conditions. Also used to power agricultural water pumping systems, to provide electricity for isolated villages and medical clinics, for corrosion protection for pipelines and bridges, to power railroad signals, air/sea navigational aids, and for many types of military systems. ARCO is now moving into large scale generation for utilities.

Source record↗

Quasi-Extended Range Optical Frequency Domain Reflectometry for Product Pipelines

Throughout the United States, large natural gas and product transmission pipelines exist. These pipelines are susceptible to failure through corrosion and cracking due to internal and external factors. As these transmission pipeline age, the likelihood of a catastrophic failure increases. The ability to the monitor corrosion and wall thickness of these pipelines is paramount to reduce risk of disastrous failure and increase reliability as well as safety. Optical frequency domain reflectometry can monitor distributed temperature and strain measurements along the natural gas and product pipelines. This measurement technique can provide valuable information of pipe structural health through hoop strain changes due to pipe wall thinning, temperature changes due to gas leaks based on Joule-Thomson effect. Since these pipelines are typically buried, the depth of the pipeline results in a potential loss in the sensing range where the fiber is not physically monitoring the hoop strain of the pipeline. A different configuration of the interferometer will allow for the distributed fiber measurement to start atop the pipeline itself. This configuration results in no loss of sensing range and maintains the sensing resolution of a typically interferometer for an optical frequency domain reflectometry measurement. The quasi-extended range distributed hoop strain measurements were demonstrated on an active transmission pipeline.

Brister, Matthew↗

Corrosion of Zinc Cold Spray Coatings in a Wet Sweet and Sour Gas Environment

Internal corrosion is a problem for steel pipelines transporting natural gas or CO 2 containing water and partial pressures of H 2 S higher than 0.3 kPa (0.05 psi). This work aims to mitigate internal corrosion in steel pipelines transporting natural gas containing H 2 S using cold spray coatings. Two types of the cold spray binary metallic coatings (zinc chromium [ZnCr]. zinc niobium [ZnNb]) were studied using electrochemical techniques: potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy. The corrosion resistance of cold spray coatings (ZnCr, ZnNb) was evaluated in an environment containing 4 bar CO 2 pressure, simulating the partial pressures found in gas transmission lines over a solution of 3.5 wt% NaCl heated to 40°C. A concentration of 0.003 M Na 2 S 2 O 3 ·5H 2 O, corresponding to H 2 S partial pressures around 0.079 bar (1.146 psi), was used to simulate sour conditions. Postcorrosion surface characterization was performed using a scanning electron microscope (SEM) equipped with an energy-dispersive x-ray spectroscope (EDS) and x-ray diffraction analysis. The data showed that the presence of 0.003 M Na 2 S 2 O 3 ·5H 2 O shifted the corrosion potential to more anodic values and decreased the corrosion current density. Both coatings showed similar behavior after 1 h of exposure in the CO 2 /H 2 S environment, indicating that similar electrochemical reactions were occurring on ZnNb and ZnCr. SEM images and EDS surface analyses for specimens showed a significant change in the surface chemical composition of carbon steel coated with ZnNb and ZnCr after 24 h of immersion. In the presence of thiosulfate (under sour conditions), the formation of corrosion product layers (ZnCO 3 and ZnS) on top of ZnNb and ZnCr coatings increased their corrosion resistance, which helped to reduce their corrosion by a factor of 2. Under a sweet environment, the corrosion rates for steel coated with cold spray coatings after 14 d of exposure are lower than that for galvanized steel by a factor of 5 due to the ZnCO 3 layer formed on top of the coatings. The ZnCO 3 layer formed on the steel surface acts as a physical barrier against corrosion by blocking the diffusion of corrosive species to the surface. No localized attack was observed. ZnCr Cold spray coating with defect showed promising corrosion protection against CO 2 corrosion (sweet corrosion) after 14 d of exposure to a CO 2 environment. Here, the scratch on the coating simulated damage created in service, and it was deep enough to expose the substrate material (steel). The formation of zinc oxide (ZnO) and zinc carbonate (ZnCO 3 ) on the scratch confirmed the cathodic protection of the steel by ZnCr and ZnNb coatings.

36 MATERIALS SCIENCE↗

The Effect of Flow on CO2 Corrosion of Self-Healing Metallic Coatings

Internal corrosion is an issue that affects natural gas pipelines, a significant part of the United States’ energy infrastructure. Over time, this corrosion has worn away longstanding pipelines due to the original construction materials used for the lines and impurities in the gas and liquid streams flowing through them. The main impurities in natural gas are H2O, CO2, H2S, and O2. One of the leading causes of corrosion is the CO2 dissolved in water, giving rise to carbonic acid formation, which can further dissolve the steel pipe. The National Energy Technology Laboratory (NETL) has been studying different solutions to this problem. One potential answer is a self-healing sacrificial metallic coating applied by a novel cold spray technique. This study explored the impact of flow on corrosion with this coating and carbon steel when exposed to a saturated CO2 environment by simulating the pipeline flow profile in a small-scale lab setting. The samples were evaluated using multiple electrochemical techniques that found corrosion rates and were backed up with surface analysis to conclude the behavior of the corrosion mechanisms. The cold spray coating exhibited steel corrosion protection under flow conditions. This study has significantly advanced our understanding of CO2 corrosion, particularly in the context of natural gas pipelines and coating design.

carbon steel↗

Simple, Tough, and Effective Porous Coating for Anti-Corrosion Application

This presentation discusses how a change in polymeric binder, the material used for assembling hydrophobic nanoparticles into a porous structure, led to better mechanical toughness and a simpler fabrication process based on 100% commercially available components. Most importantly, the optimized porous coating can reduce the corrosion rate by two orders of magnitude (0.003 mm/year) due to higher diffusion barrier based on a more resistant tortuous diffusion path. The combination of simplicity, toughness, effectiveness, and scalability greatly enhanced the prospect of commercializing this technology as an internal anti-corrosion coating for natural gas pipelines.

internal corrosion↗

The Effect of Flow on CO2 Corrosion of Self-Healing Metallic Coatings

Internal corrosion is an issue that affects natural gas pipelines, a significant part of the United States energy infrastructure. Over time, this corrosion has worn away longstanding pipelines due to the original construction materials used for the lines and impurities in the gas and liquid streams flowing through them. The main impurities in natural gas are H2O, CO2, H2S, and O2. One of the leading causes of corrosion is the CO2 dissolved in water, giving rise to carbonic acid formation, which can further dissolve the steel pipe. The National Energy Technology Laboratory (NETL) has been studying different solutions to this problem. One potential answer is a self-healing sacrificial metallic coating applied by a novel cold spray technique. Previous studies at NETL have shown that the zinc-rich self-healing coating can withstand corrosion through passivation and create a barrier to the diffusion of corrosive species. This study explored the impact of flow on corrosion with this coating and carbon steel when exposed to a saturated CO2 environment by simulating the pipeline flow profile in a small-scale lab setting. The samples were evaluated using multiple electrochemical techniques that found corrosion rates and were backed up with surface analysis to conclude the behavior of the corrosion mechanisms.

CO2 corrosion↗

ZnCr and ZnNb Cold Spray Coatings

Novel cold spray zinc-based alloy coatings have been investigated for corrosion protection of API 5L low carbon steel pipelines used in transporting natural gas. These different zinc alloy coatings are designed for use to help prevent internal corrosion and improve the lifespan of steel pipelines via sacrificial anodic protection. The corrosion behavior of these cold deposited zinc alloy coatings was investigated in CO2 saturated 3.5 wt.% NaCl solutions under simulated natural gas pipeline conditions. Electrochemical tests were conducted at 25 and 40 °C to determine the polarization resistance and galvanic current between each coating and the steel substrate in the galvanic couple. Tests were conducted at atmospheric, 1 bar, pressure. The results indicate that use of these coatings has the potential to increase the lifespan of steel pipelines above what a zinc coating alone could provide.

Teeter, Lucas↗

Fe Thin Film-Coated Optics for Corrosion Monitoring: Optical and Electrochemical Studies

Corrosion proxy materials integrated with an optical sensing platform enable a real-time optical corrosion sensor for natural gas pipelines to prevent methane leaks and catastrophic events. Effects of CO 2 , pH, and film thickness on corrosion of Fe thin films (25, 50, 100 nm) were studied using optical and electrochemical methods in 3.5%wt. NaCl solutions at 30 °C. An increase in light transmission (T%) corresponded to corrosion of Fe thin films. CO 2 accelerated corrosion of Fe thin films due to the lower pH and the promoted corrosion reactions, resulting in a faster increase of T% than without CO 2 or at higher pH. While the corrosion rate increased with increasing film thickness, electrochemical corrosion of Fe thin films was in good agreement with that of bulk carbon steel, verifying that Fe thin films can serve as a representative corrosion proxy when integrated with the optical sensing platform.

36 MATERIALS SCIENCE↗

In-Situ Pipeline Coatings for Methane Emissions Mitigation and Quantification from Natural Gas Pipelines

Addressing the current health of the nation’s existing 3 million miles of pipeline infrastructure is key to preventing further climate change. In 2020, natural gas production exceeded 34 trillion cubic feet (Tcf). Roughly 75% of natural gas consists of methane (CH 4 ), which is up to 25 times more powerful than carbon dioxide (CO 2 ) at trapping heat within the atmosphere over a 100-year period, and studies from the Environmental Defense Fund (EDF) estimate approximately 2% of all the natural gas produced will be lost during normal operations due to unaddressed leaks. This does not even consider the risks of major disaster due to pipeline failure, or the losses and extra fuel costs incurred due to corrosion and scale deposits in under-maintained pipelines. The objective of the proposed research is to demonstrate the protection capabilities and economic benefits of Oceanit’s internal pipe surface treatment, known as DragX™. DragX™ is a chemically resistant, water-and-oil repellent nanocomposite system that can be readily applied in-situ on natural gas transmission and distribution pipelines with a minimum of surface preparation. This makes it an ideal candidate for in-place retrofitting and refurbishment of existing pipelines without the need for expensive extraction and replacement. DragX™ is also able to significantly reduce the surface roughness, and subsequently, the frictional drag forces within a pipeline, improving throughput, decreasing energy costs of pressurization and pumping, and allowing for longer pipeline operation without interruption, reducing the methane emitted during pipe isolation and venting. As part of this project, Oceanit has utilized the Department of Energy’s support to fully develop, de-risk and prove the DragX™ core technology is both economically viable and commercially desirable to pipeline operators and energy companies alike. DragX™ material properties were optimized in this effort both for ease of applicability, to provide value in certain key parameters, and was demonstrated on pilot applications exceeding 2 miles in length. Beyond the already field demonstrated applications, this innovative nanocomposite surface treatment has the potential to be the backbone for CO 2 and Hydrogen transporting pipeline infrastructure. The learnings from this project could accelerate the deployment of surface treatment technologies related to the energy transition infrastructure, thus benefitting the clean energy initiatives in the United States and all around the world.

03 NATURAL GAS↗

Comments on “Failure analysis of corroded hydrogen-blended natural gas pipelines based on finite element analysis and genetic algorithm-back propagation neural network” [262 (2025) 111174]

This is a brief commentary paper to highlight and discuss the determination of hydrogen concentration in pipeline steel, effect of hydrogen embrittlement (HE) on the mechanical properties of the material, burst strength of corroded pipelines using finite element analysis (FEA) simulations, and curve-fit models for assessing remaining strength of X80 corroded pipelines for transporting hydrogen blended natural gas. Recently, Xie et al. [1] proposed a methodology to quantify the impact of HE on material properties and numerically determined burst pressure of X80 corroded pipelines. However, their HE quantification overestimated the degradation of tensile strength for hydrogen blending ratios beyond the original data range, and their FEA results of burst pressure are nonconservative. This work thus recharacterized the hydrogen concentration in the steel pipeline and the effect of HE on tensile strength, and then redetermined burst pressures for a set of typical corrosion defect cases considered by Xie et al. [1] based on an experimentally validated FEA modelling method. With the new FEA results, two empirical corrosion models were proposed for X80 corroded pipelines for hydrogen service. At zero hydrogen blending ratio, the novel empirical models predict burst pressures to be consistent with the industry-accepted corrosion models. Furthermore, both the numerical simulation method and the novel corrosion models are significant contributions to the pipeline industry and the hydrogen community. Application of these results will enhance the safety, reliability, and integrity of natural gas pipelines when used to transport hydrogen.

Burst pressure prediction↗

Monitoring pipeline integrity of underground gas storage facilities using membrane-based electrochemical sensors

Effective monitoring of internal corrosion risk is crucial to ensuring the safety and longevity of natural gas pipeline infrastructure. While electrochemical sensors are commonly used to assess corrosion rates and corrosion indicators in aqueous fluids, they are rarely used in gas pipelines as these fluids lack the ionic conductivity needed for electrochemical measurements. The inclusion of ion-conductive membranes into electrochemical sensors can extend their functionality into humidified gas streams, providing critical information about emerging corrosion events that are common during withdrawal season in pipeline systems downstream from underground storage facilities. In parallel, new protective films, like those obtained through cold spray coating, are being developed to protect oil and gas pipelines and recover losses in structural integrity due to corrosion damage. Herein, we demonstrate how membrane-based electrochemical sensors (MBES) can be used to monitor fluid corrosivity by examining their response to changes in water content for a wide range of fluid compositions. It was found that MBES readings were highly sensitive to water content changes with membrane conductivity measurements varying from 10 –6 to 10 –1 S cm -1 , and corrosion rate measurements which varied from 10 –7 to 1 mm y -1 . Electron microscopy confirmed that the self-healing characteristics of metal coating films were still active despite their inclusion into an MBES probe. In conclusion, these findings indicate that membrane-based corrosion monitoring can be expanded to monitor coated-pipeline materials and provide early detection of emerging corrosion upsets relevant to underground gas storage facilities.

Electrochemical sensor↗

Application of Field Protective Coatings over Pipeline Girth Welds

This document provides guidance for the application of two types of field protective coating on a pipeline during construction, after completion of girth weld, to mitigate external corrosion. Steel alloy B9 is applied using electric arc welding and aluminum alloy 5356 is applied using thermal spray.

03 NATURAL GAS↗

Determining Drying Conditions to Mitigate Hanford Double Shell Storage Tank Underside Corrosion — Phase 1

The Hanford Site in Washington State has legacy radiological waste that is being retrieved from single shell tanks (SSTs) and transferred to newer, double shell tanks (DSTs) for eventual closure of the SSTs. The waste is maintained in the DSTs until eventual immobilization can be performed at the Waste Treatment and Immobilization Plant (WTP), currently under construction. Until full immobilization is complete, extended service of the DSTs must be ensured by mitigating corrosion of the steel tank walls and buried steel pipelines. A Pit Air Supply System has been developed to mitigate corrosion of the leak detection pits connected to the concrete foundations of the DSTs. The objectives for the present study are: (i) to corrode steel specimens in an electrolytic simulant to form artificial pits with specific pit depths, and (ii) to determine the temperature and humidity levels that will mitigate further pit growth. Experimental work and results will be presented to evaluate conditions associated with the PASS system and predict corrosion rates when the PASS is operating.

Atmospheric Corrosion↗

Corrosion Behavior of Zinc Cold Spray Coatings in a Simulated Natural Gas Environment Containing H2O, CO2, and H2S

The natural gas transmission pipeline network in the U.S. consists of approximately 300,000 miles, is made mainly of carbon steel, and was installed in the 1950s and 1960s. Understanding the pipeline steel behavior in natural gas will inform new pipeline designs and repurposing of existing pipelines. Sulfide stress cracking (SSC) is a problem for steel pipelines transporting natural gas or CO2 containing partial pressures of H2S higher than 0.3 kPa (0.05 psi). Therefore, the objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas containing H2S using cold spray coatings.

Belarbi, Zineb↗

Quasi-Distributed Fiber Sensor-Based Approach for Pipeline Health Monitoring: Generating and Analyzing Physics-Based Simulation Datasets for Classification

This study presents a framework for detecting mechanical damage in pipelines, focusing on generating simulated data and sampling to emulate distributed acoustic sensing (DAS) system responses. The workflow transforms simulated ultrasonic guided wave (UGW) responses into DAS or quasi-DAS system responses to create a physically robust dataset for pipeline event classification, including welds, clips, and corrosion defects. This investigation examines the effects of sensing systems and noise on classification performance, emphasizing the importance of selecting the appropriate sensing system for a specific application. The framework shows the robustness of different sensor number deployments to experimentally relevant noise levels, demonstrating its applicability in real-world scenarios where noise is present. Overall, this study contributes to the development of a more reliable and effective method for detecting mechanical damage to pipelines by emphasizing the generation and utilization of simulated DAS system responses for pipeline classification efforts. The results on the effects of sensing systems and noise on classification performance further enhance the robustness and reliability of the framework.

36 MATERIALS SCIENCE↗

An Impedance-Loaded Surface Acoustic Wave Corrosion Sensor for Infrastructure Monitoring

Passive surface acoustic wave (SAW) devices are attractive candidates for continuous wireless monitoring of corrosion in large infrastructures. However, acoustic loss in the aqueous medium and limited read range usually create challenges in their widespread use for monitoring large systems such as oil and gas (O&G) pipelines, aircraft, and processing plants. This paper presents the investigation of impedance-loaded reflective delay line (IL-RDL) SAW devices for monitoring metal corrosion under O&G pipeline-relevant conditions. Specifically, we studied the effect of change in resistivity of a reflector on the backscattered signal of an RDL and investigated an optimal range through simulation. This was followed by the experimental demonstrations of real-time monitoring of Fe film corrosion in pressurized (550 psi) humid CO 2 conditions. Additionally, remote monitoring of Fe film corrosion in an acidic solution inside a 70 m carbon steel pipe was demonstrated using guided waves. This paper also suggests potential ways to improve the sensing response of IL-RDLs.

47 OTHER INSTRUMENTATION↗

Literature Review of Electromagnetic Pulse (EMP) and Geomagnetic Disturbance (GMD) Effects on Oil and Gas Pipeline Systems

This document summarizes the findings of a review of published literature regarding the potential impacts of electromagnetic pulse (EMP) and geomagnetic disturbance (GMD) phenomena on oil and gas pipeline systems. The impacts of telluric currents on pipelines and their associated cathodic protection systems has been well studied. The existing literature describes implications for corrosion protection system design and monitoring to mitigate these impacts. Effects of an EMP on pipelines is not a thoroughly explored subject. Most directly related articles only present theoretical models and approaches rather than specific analyses and in-field testing. Literature on SCADA components and EMP is similarly sparse and the existing articles show a variety of impacts to control system components that range from upset and damage to no effect. The limited research and the range of observed impacts for the research that has been published suggests the need for additional work on GMD and EMP and natural gas SCADA components.

02 PETROLEUM↗