Search NASA⌕ Search

SEARCH · Search NASA

Results for “point of care”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nucleic Acid-Based Sensing Techniques for Diagnostics and Surveillance of Influenza

Influenza virus poses a threat to global health by causing seasonal outbreaks as well as three pandemics in the 20th century. In humans, disease is primarily caused by influenza A and B viruses, while influenza C virus causes mild disease mostly in children. Influenza D is an emerging virus found in cattle and pigs. To mitigate the morbidity and mortality associated with influenza, rapid and accurate diagnostic tests need to be deployed. However, the high genetic diversity displayed by influenza viruses presents a challenge to the development of a robust diagnostic test. Nucleic acid-based tests are more accurate than rapid antigen tests for influenza and are therefore better candidates to be used in both diagnostic and surveillance applications. We review various nucleic acid-based techniques that have been applied towards the detection of influenza viruses in order to evaluate their utility as both diagnostic and surveillance tools. We discuss both traditional as well as novel methods to detect influenza viruses by covering techniques that require nucleic acid amplification or direct detection of viral RNA as well as comparing advantages and limitations for each method. There has been substantial progress in the development of nucleic acid-based sensing techniques for the detection of influenza virus. However, there is still an urgent need for a rapid and reliable influenza diagnostic test that can be used at point-of-care in order to enhance responsiveness to both seasonal and pandemic influenza outbreaks.

59 BASIC BIOLOGICAL SCIENCES↗

Pediatric Tuberculosis: The Impact of “Omics” on Diagnostics Development

Tuberculosis (TB) is a major public health concern for all ages. However, the disease presents a larger challenge in pediatric populations, partially owing to the lack of reliable diagnostic standards for the early identification of infection. Currently, there are no biomarkers that have been clinically validated for use in pediatric TB diagnosis. Identification and validation of biomarkers could provide critical information on prognosis of disease, and response to treatment. In this review, we discuss how the “omics” approach has influenced biomarker discovery and the advancement of a next generation rapid point-of-care diagnostic for TB, with special emphasis on pediatric disease. Limitations of current published studies and the barriers to their implementation into the field will be thoroughly reviewed within this article in hopes of highlighting future avenues and needs for combating the problem of pediatric tuberculosis.

59 BASIC BIOLOGICAL SCIENCES↗

Smartphone-Based Device for Colorimetric Detection of MicroRNA Biomarkers Using Nanoparticle-Based Assay

The detection of microRNAs (miRNAs) is emerging as a clinically important tool for the non-invasive detection of a wide variety of diseases ranging from cancers and cardiovascular illnesses to infectious diseases. Over the years, miRNA detection schemes have become accessible to clinicians, but they still require sophisticated and bulky laboratory equipment and trained personnel to operate. The exceptional computing ability and ease of use of modern smartphones coupled with fieldable optical detection technologies can provide a useful and portable alternative to these laboratory systems. Herein, we present the development of a smartphone-based device called Krometriks, which is capable of simple and rapid colorimetric detection of microRNA (miRNAs) using a nanoparticle-based assay. The device consists of a smartphone, a 3D printed accessory, and a custom-built dedicated mobile app. We illustrate the utility of Krometriks for the detection of an important miRNA disease biomarker, miR-21, using a nanoplasmonics-based assay developed by our group. We show that Krometriks can detect miRNA down to nanomolar concentrations with detection results comparable to a laboratory-based benchtop spectrophotometer. With slight changes to the accessory design, Krometriks can be made compatible with different types of smartphone models and specifications. Thus, the Krometriks device offers a practical colorimetric platform that has the potential to provide accessible and affordable miRNA diagnostics for point-of-care and field applications in low-resource settings.

Krishnan, Tushar (ORCID:0000000342610336)↗

Low-Cost and Portable Biosensor Based on Monitoring Impedance Changes in Aptamer-Functionalized Nanoporous Anodized Aluminum Oxide Membrane

We report a low-cost, portable biosensor composed of an aptamer-functionalized nanoporous anodic aluminum oxide (NAAO) membrane and a commercial microcontroller chip-based impedance reader suitable for electrochemical impedance spectroscopy (EIS)-based sensing. The biosensor consists of two chambers separated by an aptamer-functionalized NAAO membrane, and the impedance reader is utilized to monitor transmembrane impedance changes. The biosensor is utilized to detect amodiaquine molecules using an amodiaquine-binding aptamer (OR7)-functionalized membrane. The aptamer-functionalized membrane is exposed to different concentrations of amodiaquine molecules to characterize the sensitivity of the sensor response. The specificity of the sensor response is characterized by exposure to varying concentrations of chloroquine, which is similar in structure to amodiaquine but does not bind to the OR7 aptamer. A commercial potentiostat is also used to measure the sensor response for amodiaquine and chloroquine. The sensing response measured using both the portable impedance reader and the commercial potentiostat showed a similar dynamic response and detection threshold. The specific and sensitive sensing results for amodiaquine demonstrate the efficacy of the low-cost and portable biosensor.

60 APPLIED LIFE SCIENCES↗

Influence of point defect accumulation on in-pile thermal conductivity degradation: Fuel rod defect distribution and deviation between in-pile and post irradiation thermal conductivity

As nuclear fuel burn-up increases, its thermal conductivity degrades due to the accumulation of defects that lead to increased phonon scattering rates. This results in a rise in the centerline temperature of the fuel rod, whereby heat generation must be decreased to avoid undesired behavior such as fuel melting and extensive fission gas release. Fuel performance codes are utilized to optimize the fuel's operational conditions; while they are based on established physical principles, their empirical nature limits their predictive capabilities. Recently, an effort has been made to develop predictive fuel performance codes for commonly used nuclear fuels, as well as accelerated qualification of advanced nuclear fuels. In this report, we elaborate on the importance of careful analysis of point defects’ impact on thermal conductivity in fuel performance analysis. Further, a model is presented where point defect concentration is estimated based on Rate Theory modeling and used as input to the Klemens-Callaway model to calculate their contribution to the degradation of thermal conductivity in UO 2 under prototypical irradiation conditions. This analysis suggests that point defect concentration is significant at the rim of the fuel pellet and neglecting this leads to underestimation of the centerline temperature, which may have consequences on fission gas behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

Large-scale calculations of 𝛽-decay rates and implications for 𝑟-process nucleosynthesis

Nuclear 𝛽 decay is a key element of the astrophysical rapid neutron capture process (𝑟 process). In this work, we present state-of-the-art global 𝛽-decay calculations based on the quantified relativistic nuclear energy density functional theory and the deformed proton-neutron quasiparticle random-phase approximation. Our analysis considers contributions from allowed and first-forbidden transitions. We used two point-coupling functionals with carefully calibrated time-odd terms and isoscalar pairing strength. The new calculations display consistent results for both employed functionals, especially near the neutron drip line, suggesting slower 𝛽 decays past the 𝑁=126 neutron shell closure than in commonly used 𝛽-decay models. The new rates, along with the existing rates based on the recent nonrelativistic global calculations, are found to slow down the synthesis of heavy elements in the 𝑟 process and significantly reduce the contribution of neutron-induced fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Spatial and temporal variation in forest transpiration across a forested boreal peatland complex

Transpiration is a globally important component of evapotranspiration. Careful upscaling of transpiration from point measurements is thus crucial for quantifying water and energy fluxes. In spatially heterogeneous landscapes common across the boreal biome, upscaled transpiration estimates are difficult to determine due to variation in local environmental conditions (e.g., basal area, soil moisture, permafrost). Here, we sought to determine stand-level attributes that influence transpiration scalars for a forested boreal peatland complex consisting of sparsely treed wetlands and densely treed permafrost plateaus as land cover types. The objectives were to quantify spatial and temporal variability in stand-level transpiration, and to identify sources of uncertainty when scaling point measurements to the stand-level. Using heat ratio method sap flow sensors, we determined sap velocity for black spruce and tamarack for 2-week periods during peak growing season in 2013, 2017 and 2018. We found greater basal area, drier soils, and the presence of permafrost increased daily sap velocity in individual trees, suggesting that local environmental conditions are important in dictating sap velocity. When sap velocity was scaled to stand-level transpiration using gridded 20 × 20 m resolution data across the ~10 ha Scotty Creek ForestGEO plot, we observed significant differences in daily plot transpiration among years (0.17–0.30 mm), and across land cover types. Daily transpiration was lowest in grid-cells with sparsely treed wetlands compared to grid-cells with well-drained and densely treed permafrost plateaus, where daily transpiration reached 0.80 mm, or 30% of the daily evapotranspiration. When transpiration scalars (i.e., sap velocity) were not specific to the different land cover types (i.e., permafrost plateaus and wetlands), scaled stand-level transpiration was overestimated by 42%. To quantify the relative contribution of tree transpiration to ecosystem evapotranspiration, we recommend that sampling designs stratify across local environmental conditions to accurately represent variation associated with land cover types, especially with different hydrological functioning as encountered in rapidly thawing boreal peatland complexes.

54 ENVIRONMENTAL SCIENCES↗

Topological perturbation to a standard dehydrogenation catalyst, Pt 3 Sn

Topological materials, which exhibit protected topological surface states (TSS) near the Fermi level, have been proposed to be good catalysts. Topological catalysis may be more prevalent than we suspect, and not limited to exotic new materials. Here we study a known dehydrogenation catalyst, Pt 3 Sn alloy, which happens to be a topological semimetal, and probe the participation of TSSs in catalytic dehydrogenation of methane catalyzed by this material. Through first principle modeling and detailed analysis of the electronic structure for topological and non-topological surfaces of Pt 3 Sn, we find that TSS get significantly altered by the binding of reaction intermediates, particularly H. However, this effect of TSS on the binding of the reagents is merely perturbative, as the majority of the adsorbate binding is achieved by not-surface-focused electronic states, located much deeper below the Fermi level. Therefore, the reaction energetics and selectivity are predominantly determined by electronic states other than TSS. The fact that TSS are available for the reagent binding does not alone guarantee that the catalysis is strongly driven by TSS. However, TSS are not to be ignored, as small changes in the energetics along the reaction profile can translate into substantial differences in the reaction rate. Hence, in our view, Pt 3 Sn – a topological material – is first and foremost a standard catalyst, with added topological features, and not purely a topological catalyst. Our results point at the need to carefully consider all the bonding effects at the topological material interface.

Chemistry↗

High-Order Qubit Dephasing at Sweet Spots by Non-Gaussian Fluctuators: Symmetry Breaking and Floquet Protection

Although the Gaussian noise assumption is widely adopted in studying qubit decoherence, non-Gaussian noise sources have been detected in many qubits. Further understanding and mitigating the distinctive decoherence effect of the non-Gaussian noise remain critical. Here, we study the qubit dephasing caused by non-Gaussian fluctuators, and predict a symmetry-breaking effect that is unique to non-Gaussian noise. This broken symmetry results in an experimentally measurable mismatch between the extremum points of the dephasing rate and qubit frequency, which demands extra carefulness in characterizing the noise and locating the optimal working point. To further enhance the coherence time, we propose suppressing the second-order derivative of the qubit frequency by Floquet engineering. Our simulation on a tunable and gapped two-level quantum system, with the parameters from a heavy fluxonium, shows an order-of-magnitude improvement of the dephasing time, even after including the drive noise.

Huang, Ziwen↗

Point Defects Control Guest Molecule Diffusion in the 1D Pores of Zn(tbip)

Molecular diffusion plays a critical role in metal-organic frameworks (MOFs) within the application of kinetic chemical separations. We carefully study in this work the unexpected role of point defects for short-chain alkanes diffusing in Zn(tbip), an MOF with rigid one-dimensional (1D) channels. Inside a defect-free Zn(tbip), guest molecules are expected to follow single-file diffusion along 1D channels. It has been found previously by Heinke et al. that these parallel 1D channels are connected for molecular diffusion. Our density functional theory (DFT) calculations suggest that linker vacancy defects could arise under experimentally relevant conditions by removing a pair of linkers. Further climbing-image nudged elastic band (cNEB) DFT calculations indicate that hopping of short-chain alkanes between adjacent 1D channels over defect windows can occur at moderate temperatures. In addition to providing insights into connected adjacent 1D channels in Zn(tbip), Heinke et al. also inferred that most 1D pores are blocked from a microkinetic model. Additionally, we explored the influence of hydrolyzed linker created by the formation of linker removal inside 1D pores. Our DFT calculations show that the linkers can effectively block the pores and the linker diffusion in 1D channels is slow. Our results, for the first time, offer a mechanistic explanation of the unexpected molecular diffusion behavior in this MOF with 1D channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Differential Privacy in Grid Kitchen: Implementation & Software Documentation

Sharing of power grid feeder models faces significant challenges due to the potential risk of exposing sensitive operational information. Traditional anonymization techniques have shown notable limitations in other sensitive domains, as evidenced by documented re-identification attacks that combine supposedly anonymized datasets with auxiliary information, raising concerns that similar vulnerabilities could affect power grid data. Consequently, there is a pressing need for a more rigorous privacy protection strategy that not only delivers formal mathematical guarantees but also preserves the analytical value of the shared models. To address this challenge, we have enhanced the Grid Kitchen framework by implementing differential privacy mechanisms within the distribution model dehydration pipeline. This implementation carefully calibrates and applies noise to sensitive attributes in feeder models according to configurable privacy levels—low, moderate, and high—each offering different balances between data utility and privacy protection. Our approach uses established noise functions (Gaussian for continuous data and Discrete Laplace for integer values) with parameters carefully calibrated so that the impact of individual data points is effectively masked in the final output. The integration leverages our Noise Catalog, which we developed to categorize feeder model properties by component type, data type, and sensitivity. This catalog guides the application of appropriate noise functions and privacy parameters ($\varepsilon$ and $\delta$) to each attribute, ensuring consistent privacy protection across the model while maintaining its structural integrity and analytical usefulness. This implementation also includes evaluation tools that allow model owners to assess the impact of privacy-preserving transformations before sharing data with external parties. This report provides documentation for the differential privacy capabilities added to the Grid Kitchen project. It includes a primer on differential privacy concepts and their importance in modern data sharing, details the architecture of our implementation, explains the privacy modes and parameter configurations, and offers practical guidance on using the code for applying differential privacy to grid feeder models. Through examples and code snippets, we demonstrate the effective application of these privacy-enhancing technologies, enabling utility operators and researchers to confidently share grid data while protecting sensitive information.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation driven adaptive sampling for neutron-diffraction based strain mapping of additively manufactured parts

Neutron diffraction based strain mapping is a useful technique for measuring residual strains in additively manufactured (AM) metal parts. The measurement is traditionally done by scanning the sample in a point-wise raster pattern to extract the strain at each position. Since the overall scan can span several hours, adaptive sampling approaches using Bayesian optimization based on Gaussian process (BO-GP) regression have been introduced—demonstrating that even with a fraction of the typically made measurements the dominant strain patterns in the sample can be reconstructed. However, the parameters of the BO-GP algorithm have to be carefully chosen for best performance, and the movement time between arbitrary points can offset the time savings from a reduced number of measurement locations. In this paper, we propose algorithms to refine the BO-GP based methods by using simulations of strain patterns in AM parts based on the materials and the process used to print them. We demonstrate that the simulated strain patterns can be used to help choose better parameters for the BO-GP based framework—leading to low reconstruction error for the final strain pattern. Furthermore, we show that the strain mapping experiment can be initialized with a sampling pattern learnt from the simulation data and ordered to reduce movement time, dramatically enabling reduction in the overall time required to run the baseline BO-GP method.

Gaussian process regression↗

Transferable Adversarial Attack on 3D Object Tracking in Point Cloud

3D point cloud object tracking has recently witnessed considerable progress relying on deep learning. Such progress, however, mainly focuses on improving tracking accuracy. The risk, especially considering that deep neural network is vulnerable to adversarial perturbations, of a tracker being attacked is often neglected and rarely explored. In order to attract attentions to this potential risk and facilitate the study of robustness in point cloud tracking, we introduce a novel transferable attack network (TAN) to deceive 3D point cloud tracking. Specifically, TAN consists of a 3D adversarial generator, which is trained with a carefully designed multi-fold drift (MFD) loss. The MFD loss considers three common grounds, including classification, intermediate feature and angle drifts, across different 3D point cloud tracking frameworks for perturbation generation, leading to high transferability of TAN for attack. In our extensive experiments, we demonstrate the proposed TAN is able to not only drastically degrade the victim 3D point cloud tracker, \ie, P2B, but also effectively deceive other unseen state-of-the-art approaches such as BAT and M^2Track, posing a new threat to 3D point cloud tracking.

97 MATHEMATICS AND COMPUTING↗