Search NASA⌕ Search

SEARCH · Search NASA

Results for “power inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

FINAL PROJECT REPORT SBIR Phase II Next Generation Power Converters for Distributed Wind Applications

Intergrid, LLC, based in Temple, New Hampshire, conducted an 24-month DOE SBIR Phase II research program to develop next-generation electronic power inverters and converters for the United States distributed wind (DW) market. The distributed wind segment is defined as turbines rated from 10 kW to 1 MW, a market segment that has been almost entirely blocked by the absence of UL1741-certified, commercially available inverters.

17 WIND ENERGY↗

Designing an Intrusion Proof Adjustable Speed Drive System Controlling a Critical Process

In this paper, an intrusion proof adjustable speed drive system controlling a critical process in an industrial control system is detailed. In such a system, should the motor speed sensor signal data be compromised and/or altered via a cyber-attack, the system can potentially be unregulated, over speed and/or malfunction thereby disrupting the critical process. The proposed active detection scheme detailed in this paper introduces a private (secret) random signal termed as "watermark" into the inverter control signal that determines the PWM gating signals of the DC-AC inverter powering the motor. The watermarking signal introduced into the PWM modulation for the DC-AC inverter is shown to propagates its unique signature, which appears in all sensors signals at the inverter output such as voltage/current/speed used to control the motor. Now employing the measured data (from sensors), two statistical variance tests are conducted to identify anomalies if any in the presence of the watermarking signal. It is shown when an intrusion occurs to manipulate the sensor data to disturb and/or destabilize the process, the proposed tests immediately display a high value indicating a compromise in sensor data. It is shown that the proposed system is capable of immediate detection of a sophisticated attacks such as record/reply attack in which the actual speed sensor is disconnected and a prerecorded speed signal from the past of the same magnitude is played back to the controller. Several types of cyber-attacks such as speed reduction/increase including vibration have been tested. Extensive simulation results verify the proposed concepts. Experimental results will be discussed in the conference presentation.

Alotaibi, Faris↗

Synthetic Reference-based Transition Optimal Control of Inverter for Surge-Current-Free Rapid Interface to Grid

This article addresses the problem of the transition between objective functions in optimal control for power inverters when switching between standalone and grid-connected modes. The work proposes the use of a synthetic reference during the transition between the corresponding objective functions. Moreover, the authors aim to show that a transition function can be imposed and controlled externally from the main optimal control routine. In the end, the simulation results demonstrate the importance of properly applying the proposed strategy for a smooth transition between the operating modes with minimal surge current. These results contrast with the strategies found in the literature where the smooth transition comes with the price of a few grid cycles to sync.

Roig Greidanus, Mateo D.↗

Adaptive PV Frequency Control Strategy Based on Real-time Inertia Estimation

The declining cost of solar Photovoltaics (PV) generation is driving its worldwide deployment. As conventional generation with large rotating masses is being replaced by renewable energy such as PV, the power system’s inertia will be affected. As a result, the system’s frequency may vary more dramatically in the case of a disturbance, and the frequency nadir may be low enough to trigger protection relays such as under-frequency load shedding. The existing frequency-watt function mandated in power inverters cannot provide grid frequency support in a loss-of-generation event, as PV plants usually do not have power reserves. Here, a novel adaptive PV frequency control strategy is proposed to reserve the minimum power required for grid frequency support. A machine learning model is trained to predict system frequency response under varying system conditions, and an adaptive allocation of PV headroom reserves is made based on the machine learning model as well as real-time system conditions including inertia. Case studies show the proposed control method meets the frequency nadir requirements using minimal power reserves compared to a fixed headroom control approach.

14 SOLAR ENERGY↗

Real-time Implementation of a Dual-Active-Bridge Based Multi-Level Photovoltaic Converter

Silicon-carbide based, multi-level converters with dual-active-bridge (DAB) are getting attention for medium voltage, direct grid-connected, utility-scale photovoltaic (PV) applications due to their higher efficiency and power density. To de-risk complex control development for these high-voltage and high-power inverters, hardware-in-the-loop techniques are often required. Due to the high switching frequency and the large number of power electronic switches, off-the-shelf, real-time simulation tools are not yet fully developed for this application, even with FPGA-based simulators. To address this, a new co-simulation approach in FPGA is presented that utilizes Time-Stamped Bridge (TSB) for the higher frequency converters along with detailed fixed conductance based discrete device simulation of the rest of the circuit. A complex DAB-based PV converter with maximum switching frequency of 50 kHz is successfully simulated in real-time in the FPGA and the results are compared with offline simulation results. A controller hardware-in-the-loop (CHIL) platform is developed to demonstrate real-time, closed-loop test results for this DAB-based PV converter.

Dong, Zerui↗

Power-Sharing between Grid-Forming and Grid-Following Inverters

Power-sharing between the grid-forming and the grid-following inverter in a small microgrid is a challenging task. Specifically, the decentralized droop-based power-sharing is difficult to achieve when the grid-forming inverter regulates the voltage and the frequency. This article proposes controllers for the grid-forming and the grid-following inverters, which ensure proportional power-sharing as well as regulate the voltage and the frequency. Both controllers use active power-frequency and reactive power-voltage droops. Additional secondary loops and secondary forward paths are added to the controller of the grid-forming inverter and the grid-following inverter, respectively, to ensure simultaneous voltage and frequency regulation and power-sharing. The efficacy of the proposed controllers for power-sharing is verified through experiment results in a multi-inverter testbed.

Sadeque, Fahmid↗

Device- and System-Level Thermal Packaging for Electric-Drive Technologies (Final Technical Report)

Final Technical ReportThis project aimed to research, develop, and test electric traction drive system technology for use in vehicle applications that are capable of meeting the targets set by the Department of Energy Vehicle Technologies Office. The project is categorized into three major thrusts: Bonding interfaces for packaging, thermal management of electric vehicle (EV) power inverters, and electric motor thermal management. Device- and System-Level Thermal Packaging for Electric-Drive Technologies project aimed to develop, analyze, and validate transformative approaches in thermal management and packaging for power electronics and electric motor systems, with the ultimate goal of enhancing power density, efficiency, and reliability in electrified transportation platforms.

33 ADVANCED PROPULSION SYSTEMS↗

Effects of Encapsulant Properties on the Thermo-Mechanical Reliability of Double-Side Cooled Power Modules for Traction Inverters

Double-side cooled power modules are being developed for next-generation traction inverters due to their better heat extraction, lower profile, and lower parasitic inductances. However, due to their rigid structure, they cause reliability concerns arising from high thermo-mechanical stresses at the interconnection joints in the module. In this work, a materials-based approach using rigid encapsulants is presented for reducing thermo-mechanical fatigue. Finite-element thermo- mechanical simulations were performed to examine the effects of the elastic modulus and coefficient of thermal expansion of epoxy- based encapsulants on the bond deformation inside a double-side cooled power module. It was found that a rigid encapsulant with a high modulus of 6.0 GPa or above and a coefficient of thermal expansion around 20 ppm/oC would improve the thermo- mechanical reliability of double-side cooled power modules by decreasing the permanent bond deformation inside the modules by 50-60%.

ADVANCED PROPULSION SYSTEMS↗

A Two-Stage Approach for PV Inverter Engagement in Power Factor Correction and Voltage Regulation

The rapid integration of distributed energy resources, like solar photovoltaics (PVs), can lead to overvolt-age challenges due to reverse power flow and a noticeable decrease in power factor at the substation interface. While existing literature extensively explores utilizing smart inverter capabilities for reactive power flexibility using a volt-var curve (VVC), obtaining time-varying operating points of such curves in real-time is challenging due to computational demands and communication requirements. Similarly, employing optimization-based approaches for reactive power control and active voltage regulation in large-scale distribution feeders is difficult due to the complexity of the problem and the challenges in effectively engaging customer-owned resources. This paper proposes a two-stage strategy to harness smart inverters for reactive power support. The first stage formulates short-term planning by optimally designing VVCs (on a daily or hourly basis) for large-scale solar PVs based on projected system needs and communicating optimal curves to smart inverters in advance. Subsequently, the second stage employs a transactive-based method to involve customer-owned PVs for reactive power support, effectively enhancing overall system performance and addressing real-time demands. In conclusion, the efficacy of this approach will be demonstrated using real-world distribution circuits provided by Vermont Electric Power Company (VELCO) and Vermont Electric Cooperative (VEC).

Poudel, Shiva [Pacific Northwest National Laborato↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Reproducible Validation of Algorithms for Estimating Array Tilt and Azimuth from Photovoltaic Power Time Series

In this research, we assess the viability of four different, publicly available algorithms for estimating the azimuth and tilt parameters of solar photovoltaic systems using only the associated AC power time series data and site latitude-longitude coordinates. In this work, we curated a benchmarking data set of 44 fixed-tilt systems, comprising 275 measured AC power inverter data streams, with known azimuth and tilt parameters. Additionally, we isolated test cases in the data set with real- world issues, including shading and clipping, to determine how algorithm performance varies based on the presence of these phenomena. Using this data set for benchmarking, we evaluated the estimated vs. actual system characteristics for each algorithm, as well as the associated algorithm execution time using a standardized benchmarking process. The two highest performing algorithms were the Solar Data Tools and the PVWatts 5- based methods, which both achieved a median absolute error of approximately 5 and 1 degrees for azimuth and tilt, respectively. During run time analysis, the SDT method was approximately 5 times faster than the PVWatts 5-based method, with the median execution time for a stream varying between 6 and 8 seconds vs. a median run time of 31 seconds for the PVWatts 5-based method.

azimuth↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

A Reproducible Validation of Algorithms for Estimating Array Tilt and Azimuth from Photovoltaic Power Time Series

In this research, we assess the viability of four different, publicly available algorithms for estimating the azimuth and tilt parameters of solar photovoltaic systems using only the associated AC power time series data and site latitude-longitude coordinates. In this work, we curated a benchmarking data set of 44 fixed-tilt systems, comprising 275 measured AC power inverter data streams, with known azimuth and tilt parameters. Additionally, we isolated test cases in the data set with real-world issues, including shading and clipping, to determine how algorithm performance varies based on the presence of these phenomena. Using this data set for benchmarking, we evaluated the estimated vs. actual system characteristics for each algorithm, as well as the associated algorithm execution time using a standardized benchmarking process. The two highest performing algorithms were the Solar Data Tools and the PVWatts 5-based methods, which both achieved a median absolute error of approximately 5 and 1 degrees for azimuth and tilt, respectively. During run time analysis, the SDT method was approximately 5 times faster than the PVWatts 5-based method, with the median execution time for a stream varying between 6 and 8 seconds vs. a median run time of 31 seconds for the PVWatts 5-based method.

algorithm validation↗