Search NASA⌕ Search

SEARCH · Search NASA

Results for “pumping test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Capacity Performance of a Stirling-Cycle Water-to-Water Heat Pump

The performance of a 10 kW (2.8 ton) heat pump has been modeled in preparation for evaluation in a controlled-atmosphere psychrometric facility. The heat pump uses an electrically driven Stirling engine with nitrogen as a working fluid. The appropriate standards for testing are ANSI/AHRI/ASHRAE ISO Standard 13256-2:1998 (RA 2012), Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-Water and Brine-to-Water Heat Pumps. The heating and cooling efficiency and capacity of the device has been modeled at different hot and cold sink temperatures spanning a wide range of possible operating conditions. The heat pump was designed for a seasonal efficiency energy ratio (SEER) of 22. The high efficiency of this product coupled with the use of nitrogen as a working fluid makes it an important tool for the decarbonization of residential, commercial, and industrial HVAC&R applications.

Kowalski, Steve↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing and Modeling of Subscale Ice-on-Coil Module as Low Temperature Reservoir for sCO2 based Pumped Thermal Energy Storage Systems

Echogen tested approximately 10 kWthsubscale IOC system in their lab in Akron, OH for studying the feasibility, endurance and performance impact of the technology on PTES system. This paper discusses the test loop setup, testing and results from this sub-scale IOC testing. Along with testing, the project team also developed sub-scale IOC transient model. The paper discusses this transient model development and its validation against the test data.

Avadhanula, Vamshi Krishna [Echogen Power Systems ↗

ATR Firewater Pump Replacement

The objective of this project is to replace two faulty firewater pumps at INL's Advanced Test Reactor (ATR). Around ATR, firewater pumps can serve from one to all three of these functions: emergency core injection, emergency canal makeup, and firefighting. Both pumps serve firefighting functions but one also serves the function of emergency canal makeup, a nuclear function, so it is required to go through nuclear grade dedication. Both pumps are currently in the process of being procured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PW2 Pumping: March 18 thru March 22, 2020

Processed Coherence-length-gated Microwave Photonics Interferometry (CMPI) distributed vertical strain on March 18 through March 22, 2020 at the hydromechanical test facility located at the Clemson University Simpson Station research facility in Central, South Carolina, USA. This includes ambient data in addition to a pumping test performed between 14:31-20:31 EST on 3/22/2020 from Pumping Well 2 (PW2). These data are from a strain ribbon that was deployed in the vadose zone at approximately 34.670130°N, -82.729524°E from the ground surface to a depth of 8m in saprolite containing weak reflectors pairs were placed every 0.85 m along the fiber. Each weak reflector pair forms a 15 cm cavity strain meter. Strain unit: meters/meter (strain). Sampling rate 0.1 Hz. Each column corresponds to the strain data taken at a depth d from the ground surface. c1: d = 1.00m c2: d = 1.85m c3: d = 2.70m c4: d = 3.55m (large demodulation error) c5: d = 4.40m c6: d = 5.25m c7: d = 6.10m (large demodulation error) c8: d = 6.95m

Distributed Strain Sensing↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and material selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including Colmonoy grades, Stellite grades, and a novel Nickel Tungsten Carbide alloy (HybrimetTM NiWC3b) used as a High Velocity Oxygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the molten salt. The pump wetted components are made of Inconel 625 and features a carbon ring seal (CIRPAC Seal) flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. A comprehensive pump test program has been completed. Over 90 hours run time pumping hot chloride salts at temperatures up to 720 °C in which enough data was captured to produce performance curves at 3 different operating speeds. This research showcases a promising design for use in the Concentrated Solar Power (CSP) Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys.

14 SOLAR ENERGY↗

DOE Hanford Tank Side Cesium Removal System (TSCR) Update: Fabrication and Factory Acceptance Testing - 20300

The Tank Side Cesium Removal (TSCR) System is a modular, quickly-deployable, and passively safe system for efficiently removing solids and cesium from alkaline liquid waste raffinate created by fuel processing on the Hanford site. This paper provides an overview of the project with particular emphasis on completion of fabrication and factory acceptance testing (FAT). All TSCR System components are inside three enclosures known as the Process Enclosure, Ancillary Enclosure, and Control Enclosure. The Process Enclosure is seismic design category II (SDC-II) and built to withstand the rigors of transportation and lifting, high winds, volcanic ash fall, and heavy precipitation (snow) over a temperature range of -25 to 115 deg. F. The Process Enclosure and Control Enclosure were fabricated in AVANTech's Columbia, SC facility, while the Ancillary Enclosure was fabricated in AVANTech's Richland, WA facility. The design and preliminary documented safety analysis were completed in December 2019, with all work being performed in accordance with ASME NQA-1 quality assurance requirements. The Process Enclosure, Ion Exchange Columns (IXCs), and several other TSCR components have a nuclear safety function and are designated as safety significant structures, systems, and components (SS-SSCs). The NQA-1 Commercial Grade Dedication (CGD) process was used to identify critical characteristics in order to accept materials and items used for fabrication of several safety significant TSCR components. This paper also addresses unique aspects and challenges of implementing CGD in DOE facilities and systems. After fabrication and preliminary testing, the Process and Control Enclosures were shipped to AVANTech's Richland facility where the complete TSCR System was setup and connected in a represented layout and configuration that will be used on the Hanford site. Test tanks and pumps were put in place and connected to the TSCR Process Enclosure in a manner that mimicked interfacing Double Shell Tanks in the 241-AP Tank Farm. The TSCR System was then tested/operated under conditions equivalent to those planned for onsite operation. Testing was separated into five separate phases as defined below: - Phase 1: Confirmation of TSCR System readiness for the FAT; - Phase 2: Verification of TSCR System operation under standard conditions; - Phase 3: Demonstration of TSCR System operation under non-standard conditions; - Phase 4: Demonstration of ion exchange media removal from an IXC; and - Phase 5: Completion of TSCR System lift plans and site mobilization. The Hanford Tank Operations Contractor, Washington River Protection Solutions (WRPS), participated in all phases of testing. Testing at AVANTech's Richland Facility allowed WRPS personnel to familiarize themselves with TSCR operations in a radiologically clean facility prior to onsite mobilization. Engineering and operations personnel gained valuable experience that allowed them to better refine onsite operational protocols and procedures - including handling and movement of IXCs with a forklift. This paper describes the technologies used by the TSCR System as well as how these technologies are deployed and operated to advance the Hanford mission of safely, efficiently, and effectively treating tank waste. It also provides detailed information on fabrication and FAT, including operational data from simulated tank waste runs. A project schedule for WRPS' planned construction acceptance testing, operational acceptance testing, and actual tank waste treatment is provided. This presentation should be of great interest to parties responsible for the design, testing, and mobilization of modular NQA-1 technologies for the treatment of raffinate and similar liquid wastes containing high concentrations of radioactive cesium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continued Testing and Modeling of the AirSquared All-Metal Tritium Scroll Pump

The implementation of fusion energy requires the processing of the deuterium-tritium mixture used to fuel the reaction. Many gas processing operations require either a gas-motive force or a pressure gradient across a system; both are achieved using vacuum pumps. However, because of the material challenges of working with tritium, specialized pumps are required that use only metal on wetted surfaces. This prevents tritium retention and degradation of materials such as oils and polymers and reduces the generation of tritiated waste. Typical gas handling systems for tritium operations involve metal bellows pumps, all-metal scroll pumps, and metal turbomolecular pumps, depending on the pressure requirements. With the industry standard Normetex Type 15 m 3 /h (typically referred to as the Normetex 15) pump no longer available, the fusion market requires viable alternatives. In this study, we test an American-made pump, the AirSquared V16H034A-C01, and compare its performance to the Normetex. A performance model of the AirSquared pump is also produced, which can be applied to general process models to generate an accurate description of pressures and flows through various unit operations.

08 HYDROGEN↗

Wave-powered water pump for upwelling in aquaculture: Numerical model and ocean test

Wave-powered upwelling can increase the productivity and survivability of several aquaculture species. This enhancement is due to transporting cold, nutrient-rich ocean water, typically found lower in the water column, to the surface. Macroalgaes, like kelp, exhibit increased growth from these altered conditions. The University of New Hampshire’s (UNH) wave-powered water pump (wave pump) is a point absorber wave energy converter (WEC) that uses ocean waves to create relative motion between a spar buoy and a concentric float which drives an internal pump. A numerical model of the wave pump was developed using WEC-Sim to predict device performance in the ocean. Wave pump performance was evaluated during a five day ocean test near Appledore Island in Maine in March 2023, where volumetric flow rate, relative distance between spar and float, and wave conditions were measured. These data were then used for numerical model validation. The ocean deployment recorded the device’s performance in a variety of sea states, with average significant wave heights up to 0.7 m. The ocean test data were compared to the WEC-Sim numerical model of the device with favorable results. Average values of device stroke period, stroke height, and flow rate agreed between the ocean test and model data to within approximately 16 to 22%. Furthermore, the validated numerical model provides a valuable tool for improving the design and developing a commercial-scale, wave-powered water pump for use in aquaculture.

16 TIDAL AND WAVE POWER↗

AMS Thermal Cooling System (Final Report)

The Alpha Magnetic Spectrometer (AMS) is a U.S. Department of Energy-sponsored particle physics experiment on the International Space Station (ISS). AMS is exploring some of the most fundamental questions in physics such as understanding dark matter, antimatter, the origin of cosmic rays and their characteristics as well as searching for new physics phenomena in the universe. It has recorded more than 200 billion cosmic rays since its launch in May 2011. Over time, anomalies associated with the dedicated cooling system of the AMS Silicon Tracker system were observed, leading to the discovery of progressive deterioration in the functioning of the cooling system's four redundant pumps. The Tracker is crucial to the scientific mission of AMS, as it is the only subdetector that can distinguish matter from antimatter. This report details the successful program of work for the installation of the Upgraded Tracker Thermal Pump System (UTTPS) on AMS. This program included: identifying the root cause of deterioration in the original pumps; design, production, testing, and integration of the new UTTPS cooling system; launch of the UTTPS to ISS; installation of the UTTPS in AMS across a series of four complex extra-vehicular activities (EVAs); and establishment of a dedicated Flight Simulator Laboratory to test the performance of the UTTPS under various thermal conditions. This program was critical to the success of the AMS experiment, and its successful completion will enable AMS to continue taking data through 2030.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gallium Arsenide Semiconductor Opening Switches: Enabling Nanosecond High Powering Pulsed Systems

The goal of this work awas to investigate design manufacturing semiconductor opening switches (SOS) in both silicon and gallium arsenide (GaAs). Solid-state opening switches are critical components for pulsed power systems and applications in directed energy, dielectric wall accelerators, and novel semiconductor manufacturing techniques. Under this funding, we have developed silicon SOS designs that suppresses an unwanted prepulse, increases the peak output voltage by about 10 percent, and reduces the pulse rise time by ~ 4x compared with more conventional profiles. Through this effort we have improved device fabrication and bonding techniques. Additionally, work on this the GaAs opening switch has defined a unique application space that these devices are suited for. GaAs opening switches have short risetimes and pulse widths compared to silicon devices, however the short carrier lifetime of GaAs makes the circuit design more challenging than in silicon. For high PRF operation, the lifetime of the GaAs is an advantage compared to silicon. TCAD simulations of GaAs devices have been used to optimize a GaAs profile. Additionally, we have designed pulsers with sub 50ns reserve pump times and tested GaAs COTs PIN diodes in them.

42 ENGINEERING↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Normetex Replacement Development

Outline • Background • Previous development efforts • Air Squared redesign • Non-scroll alternatives • Pump performance • Pump performance comparison • Test system overhaul • Conclusions

Angelette, Lucas M. [Savannah River National Labor↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

Next Generation Refrigerants for Domestic Heat Pump Water Heaters

To select next generation refrigerants and phase out R-134a, we conducted extensive drop-in tests of multiple new refrigerants. For laboratory investigations, we performed drop-in UEF (uniform energy factor) and FHR (first hour rating) tests on two heat pump water heaters (HPWHs), one uses a 220V compressor and 40-gallon water tank, and the other uses a 120V compressor and 50-gallon tank. The alternative refrigerants/blends include R-1234yf, R-1234ze, R-515B, R-513A, and R-516A, among which R-513A is A1, non-flammable and the others are in A2L category. All the alternative refrigerants required similar optimum system charges as the baseline R-134a. They resulted in similar or better UEFs than R-134a. R-516A led to best UEFs in both the HPWHs. The resultant discharge temperatures of the new refrigerants/blends are lower than R-134a, indicating good lubricant compatibility. The 120V HPWH delivered > 60 gallons first-hour rating using R-134a. The alternatives led to reduced FHRs due to their smaller volumetric vaporization capacities using the same compressor. Except R-515B, the other refrigerants/blends delivered FHRs > 60 gallons. R-516A produced better UEFs and FHRs in both the units than the other replacements. If considering flammability, R-513A would be the best option, which has similar UEF and FHR as R-134a.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗