Search NASA⌕ Search

SEARCH · Search NASA

Results for “reliability increase storage capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing Photovoltaic Capacity Factor Variability Using Long-Term Satellite Derived Solar Resource Data Under Brazilian Climate

Accurate estimation of photovoltaic (PV) energy yield and its variability is essential for reducing financial risk and supporting reliable system planning for rapidly expanding PV markets. In Brazil, high solar adoption and increasing levels of distributed energy resources are beginning to introduce operational challenges such as curtailment and evolving grid requirements. Understanding how natural variability in solar resource propagates into PV system performance is therefore increasingly important for both project design and grid integration. Modern PV yield assessments commonly rely on multi-year meteorological datasets and probabilistic exceedance metrics (e.g., P50/P90) to quantify energy yield uncertainty for project financing. However, the implications of long-term solar resource variability for PV system design choices and high-adoption grid conditions remain less well characterized for rapidly expanding markets such as Brazil. In particular, understanding how weather-driven variability propagates into PV production distributions and capacity factor expectations is important for evaluating curtailment exposure, deployment strategies, and storage requirements in regions experiencing rapid growth of distributed and utility-scale PV. Seasonal and interannual variability in atmospheric conditions can produce substantial fluctuations in monthly PV energy production, which propagate into uncertainty in annual energy yield and capacity factor expectations. Characterizing this variability using long-term meteorological datasets allows probabilistic estimation of PV system performance and provides improved insight into the range of expected PV energy outcomes. This study explores the use of long-term satellite-derived meteorological data from the National Solar Radiation Database (NSRDB) to evaluate the variability of photovoltaic system performance across multiple locations in Brazil. Using a 27-year dataset (1998-2024), PV system simulations are performed to characterize the distribution of annual and seasonal capacity factors and energy yield outcomes, while propagating key sources of meteorological variability and model uncertainty through the PV modeling chain. The analysis also investigates the sensitivity of PV performance outcomes to key system design assumptions within the PV modeling chain, including tracking configuration and system sizing parameters. The resulting probabilistic performance characterization provides insight into how weather-driven variability influences PV production expectations and capacity factor distributions. These results provide a foundation for evaluating how weather-driven variability interacts with high PV adoption and potential storage or curtailment mitigation strategies.

14 SOLAR ENERGY↗

Average and Marginal Capacity Credit Values of Renewable Energy and Battery Storage in the United States Power System

As deployment of renewable resources and storage continue to significantly grow in the coming decades, these technologies will play increasingly important roles in maintaining power systems' resource adequacy. Few analyses so far offer comprehensive comparisons of forward-looking average and marginal capacity credits of variable renewable energy and storage in the U.S. interconnections across a wide range of possible futures. To fill this research gap, we quantify the average and marginal capacity credits of solar PV, onshore and offshore wind, and batteries between 2026 and 2050 across the U.S power systems to examine the temporal trends, spatial patterns, and trade-offs between these two capacity accreditation approaches. Across technologies, capacity credits of solar PV most clearly follow downward trends over time, reflecting the significant rise in solar PV generation share as the grid decarbonizes. While battery storages' generation shares also rise significantly over time, their capacity credits always remain stably high due to their capabilities to be dispatched strategically during critical periods to maintain reliability. On the other hand, capacity credits of wind technologies in general follow slight upward trends as their generation shares level off. There are strong spatial variabilities of both average and marginal capacity credits across technologies, but capacity credits of solar PV displaying the most obvious spatial patterns with high capacity credits concentrating in wind-rich, solar-poor regions in SPP, PJM, and MISO, suggesting potential reliability benefits of interconnection-wide planning for renewable energy deployments. Additionally, except for offshore wind, average capacity credits of all other renewable technologies tend to be higher than their marginal capacity credits, indicating that existing renewable resources tend to be accredited higher than new resources at almost any time.

25 ENERGY STORAGE↗

Addressing Failures in Molten Salt Thermal Energy Storage Tank for Central Receiver Concentrating Solar Power Plants

The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.

concentrating solar power↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

High Performance Parallel Computational Nanotechnology

At a recent press conference, NASA Administrator Dan Goldin encouraged NASA Ames Research Center to take a lead role in promoting research and development of advanced, high-performance computer technology, including nanotechnology. Manufacturers of leading-edge microprocessors currently perform large-scale simulations in the design and verification of semiconductor devices and microprocessors. Recently, the need for this intensive simulation and modeling analysis has greatly increased, due in part to the ever-increasing complexity of these devices, as well as the lessons of experiences such as the Pentium fiasco. Simulation, modeling, testing, and validation will be even more important for designing molecular computers because of the complex specification of millions of atoms, thousands of assembly steps, as well as the simulation and modeling needed to ensure reliable, robust and efficient fabrication of the molecular devices. The software for this capacity does not exist today, but it can be extrapolated from the software currently used in molecular modeling for other applications: semi-empirical methods, ab initio methods, self-consistent field methods, Hartree-Fock methods, molecular mechanics; and simulation methods for diamondoid structures. In as much as it seems clear that the application of such methods in nanotechnology will require powerful, highly powerful systems, this talk will discuss techniques and issues for performing these types of computations on parallel systems. We will describe system design issues (memory, I/O, mass storage, operating system requirements, special user interface issues, interconnects, bandwidths, and programming languages) involved in parallel methods for scalable classical, semiclassical, quantum, molecular mechanics, and continuum models; molecular nanotechnology computer-aided designs (NanoCAD) techniques; visualization using virtual reality techniques of structural models and assembly sequences; software required to control mini robotic manipulators for positional control; scalable numerical algorithms for reliability, verifications and testability. There appears no fundamental obstacle to simulating molecular compilers and molecular computers on high performance parallel computers, just as the Boeing 777 was simulated on a computer before manufacturing it.

Saini, Subhash↗

Novel Organosulfur-Based Electrolytes for Safe Operation of High Voltage Li-ion Batteries over a Wide Operating Temperature

This project addresses the failure of conventional electrolytes and enables high-voltage operation of lithium-ion batteries (LIBs) by developing a novel organosulfur-based electrolyte system. To achieve this goal, we first designed and synthesized new organosulfur solvents that functionalized with strong electron-withdrawing groups such as fluoroalkyl and cyano substituents. Through regio-specific molecular engineering, supported by theoretical calculations, we lowered the highest occupied molecular orbital (HOMO) energy levels of these molecules to increase their anodic stability for high-voltage operation. We then optimized the formulation of the organosulfur-based electrolyte with additives, co-solvents and salts tailored to the newly synthesized solvent molecules. In parallel, we utilized advanced spectroscopic techniques—including in situ FTIR, EIS, and DEMS—to thoroughly elucidate the mechanisms of interaction between the electrolyte and electrode materials. Finally, we evaluated 2 Ah pouch cells under both normal and extreme conditions. Pouch cells with the newly developed electrolyte system demonstrated >90% capacity retention after 500 cycles under 4.5 V operating voltage, >80% capacity retention after 1000 cycles in coin cell level. In addition, the cells exhibited high safety and reliable operation capability over a wide temperature range from −30 °C to +45 °C.

25 ENERGY STORAGE↗

Heteroatom-Modified and Compacted Zeolite-Templated Carbons for Gas Storage

Methane, the primary component of natural gas, is an energy-rich fuel by weight but exhibits lower energy density by volume than diesel and gasoline; efforts to increase its “volumetric” energy density have been focused on the design and synthesis of a porous scaffold that can bind the methane favorably. Novel approaches typically invoke the highly designable class of materials known as metal-organic frameworks (MOFs) owing to the relative difficulty of controlling carbon structure and composition precisely, without the use of a metal-based node. In this project, we instead explore the concept of carbon templating to achieve a porous scaffold with atomistically thin walls separated at a distance of ~1.2 nm, ideal for the formation of precisely two layers of methane per pore. This bottom-up templating approach permits the use of any small molecular precursor to build up the carbon scaffold, begging the question: which other elements (besides carbon) can be used to tune the surface for optimal methane binding without compromising the structure of the overall material? Boron and nitrogen were both explored and nitrogen was identified as the ideal agent for increasing methane binding to the optimal strength for use at near room temperature. Densification of the resulting materials by mechanical compaction was then explored to produce free-standing pellets with the highest methane “delivery” capacities of any known material. Here we define the amount “delivered” as the amount stored minus the amount remaining in the tank at 73 psi, the lowest useful pressure for vehicular transportation applications. The key features of the resulting methane storage system are rapid discharging and refueling speeds, extremely long cycle life (infinite cycle life for high-purity methane), a near-constant heat of refueling (making the heat generated upon refueling easier to manage), and a low maximum pressure of operation (<1500 psi), enabling the use of all-metal Type I cylinders and significantly reducing the costs of conversion of existing vehicles to cleaner burning, abundantly available natural gas). The technical effectiveness of this approach was further improved by exploring several cost-reduction strategies and investigating the reliability of such storage systems in the presence of “real” natural gas mixtures which contain a mixture of gaseous species.

03 NATURAL GAS↗

Lithium–Sulfur Batteries: 3D Printed Tools and Assembly Techniques for Repeatable Lab-Scale Coin Cell Manufacturing

The coin cell form factor has become a standard in energy storage research owing to its relatively low cost, low quantity of requisite electroactive material, fast experimental turnover, and capability to generate publishable quality data. Coin cell assembly at the lab-scale requires precise manual alignment of the many internal components of a cell to yield a properly functioning device. Truly repeatable device assembly presents a significant challenge to the acquisition of reliable data. In this report, we present a three-dimensional (3D) printable design for a coin cell alignment device and describe techniques for a generalized workflow to achieve reproducible coin cell assembly of lithium-based batteries. Standardized assembly techniques using readily accessible, purpose-built tools were demonstrated for labscale production of lithium−sulfur (Li−S) coin cells. Li−S batteries fabricated using the alignment device as well as conductive adhesive incorporated workflows afforded coin cells with up to 35% reduction of assembly times, comparable or better functional cell yields, and improved electrochemical device performance with more consistent and up to 150 mAh/g higher average discharge capacities coupled with Coulombic efficiency increases of up to 2.0% over manually aligned cell assembly techniques.

Batteries↗

Multi-scale impacts of climate change on hydropower for long-term water-energy planning in the contiguous United States

Climate change impacts on watersheds can potentially exacerbate water scarcity issues where water serves multiple purposes including hydropower. The long-term management of water and energy resources is still mostly approached in a siloed manner at different basins or watersheds, failing to consider the potential impacts that may concurrently affect many regions at once. There is a need for a large-scale hydropower modeling framework that can examine climate impacts across adjoining river basins and balancing authorities (BAs) and provide a periodic assessment at regional to national scales. Expanding from our prior assessment only for the United States (US) federal hydropower plants, we enhance and extend two regional hydropower models to cover over 85% of the total hydropower nameplate capacity and present the first contiguous US-wide assessment of future hydropower production under Coupled Model Intercomparison Project phase 6’s high-end Shared Socioeconomic Pathway 5-8.5 emission scenario using an uncertainty-aware multi-model ensemble approach. We present regional hydropower projections, using both BA regions and US Hydrologic Subregions (HUC4s), to consistently inform the energy and water communities for two future periods—the near-term (2020–2039) and the mid-term (2040–2059) relative to a historical baseline period (1980–2019). We find that the median projected changes in annual hydropower generation are typically positive—approximately 5% in the near-term, and 10% in the mid-term. However, since the risk of regional droughts is also projected to increase, future planning cannot overly rely on the ensemble median, as the potential of severe hydropower reductions could be overlooked. The assessment offers an ensemble of future hydropower generation projections, providing regional utilities and power system operators with consistent data to develop drought scenarios, design long duration storage and evaluate energy infrastructure reliability under intensified inter-annual and seasonal variability.

13 HYDRO ENERGY↗

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy storage planning for enhanced resilience of power systems against wildfires and heatwaves

Extreme weather events pose significant risks to power grid stability due to their severe consequences and potential for widespread failures. Energy storage systems hold great potential for enhancing grid resilience against such events by providing reliable power during peak demand periods. However, accurately quantifying the size, location, and investment costs of new energy storage assets is a complex task, as energy storage planning decisions depend on the investment choices of other generation technologies and the integration of new transmission projects. Here, this paper presents a novel capacity expansion planning framework that simultaneously optimizes investments in energy storage, generation, and transmission, determining their optimal size, location, and type, while incorporating extreme weather events into long-term planning. More specifically, our stress-event-informed planning framework integrates the impact of heatwaves and wildfires into the planning process, identifying least-cost investment solutions that comply with policy goals and enhance grid resilience. The proposed framework employs machine-learning-based modeling to project heatwave-induced loads and performance-based risk assessment to evaluate wildfire-driven transmission line derates. Using industry-standard datasets to accurately represent the transmission topology of the Western Interconnection (WI) system, the proposed framework is applied to the WI 40-zone system, with investment decisions reported for the years 2030, 2035, and 2040. Simulation results reveal that with just a 10% increase in investment costs, resilience against extreme events can be significantly improved, with investment decisions heavily favoring energy storage, particularly 4-hour energy storage systems.

25 ENERGY STORAGE↗

Going beyond reliability to achieve robustness

Reliability is the ability to perform well and consistently. More formally, reliability is defined as the mathematical probability that a system does not fail during a specified time period under its specified operating conditions. The specified operating conditions often go beyond the nominal environment to include variations and challenges encountered in operational use. The difficulty is that systems are often operated outside of their specified operating conditions and, if they fail, the designers are in theory blameless. Unanticipated damaging events include internal failures, external disruptions in supporting systems, accidents, and repurposing. The most common explanation of a system failure is human error, which is usually the first assumption of the system designers. Robustness is the capability to perform without failure under a wide range of conditions that go beyond the specified operating conditions. The first step towards improving robustness would be to expand the system’s specified operating conditions to include a wider range of anticipated challenges, especially human error. Beyond this, there is a need for general approach to reduce the impact of unanticipated future events, the unknown unknowns, by improving the system’s general ability to cope. Robustness can be improved by providing additional processing capacity, larger flow control buffers, increased backup storage, more online redundancy, and more capable supervisory monitoring and control.

Harry W Jones↗

Decarbonization and technology cost drivers: considerations for potential future thermoelectric water use in the power sector

The power sector is currently undergoing significant changes, driven by a combination of factors, including decarbonization and technology innovation. This study aims to assess implications of these drivers on U.S. power sector technology futures and the associated water and environmental implications for cooling thermoelectric power plants. Specifically, we evaluate four decarbonization scenarios for the contiguous United States that vary in assumptions concerning demand growth and technology costs, with technology costs driving alternative outcomes that prioritize either technologies that require low amounts of water (such as wind, solar, and battery) or high amounts of water (such as nuclear and carbon capture and storage). These scenarios are executed in a power sector capacity expansion model and compared to two reference scenarios that assume status quo with policy and cost drivers. Our analysis indicates that future U.S. thermoelectric water withdrawals could decrease by 25%–60%, but water consumption could more than triple in some scenarios. These changes are driven by a combination of retirement of some power facilities, shifts in cooling technologies, and new technology deployment. The water use patterns vary across the United States, with the eastern regions demonstrating a lot more variability in water consumption across scenarios than western regions. However, local concerns can influence these possible investments, since increased water consumption can exacerbate water scarcity, leading to conflicts among competing users and affecting regional social, environmental, and economic dynamics. Future work should consider possible costs associated with alternate water sources, as well as improve the representation of water constraints within simulations. Inclusion of extreme events and alternate modeling platforms (e.g. production cost modeling and resource adequacy) may also be warranted to further stress test the robustness of these possible technology futures. Such assessments will be critical for ensuring decarbonization and other infrastructure-oriented investments lead to a reliable and resilient power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-nickel cathode chemistry for sustainable and high-energy lithium-ion batteries

The transition to sustainable energy storage demands lithium-ion batteries with high energy density and reduced reliance on critical metals such as nickel (Ni), yet current strategies to increase capacity have largely depended on raising Ni content, leading to escalating supply risks, rising costs and sustainability concerns. More critically, Ni-rich cathodes suffer from rapid electrochemical degradation driven by structural instability, creating an insurmountable trade-off between capacity and cycle life. Here, in this study, we introduce a low-Ni chemistry cathode, Li(Li 0.05 Ni 0.57 Mn 0.31 Co 0.07 )O 2 , with a radial phase integration design that overcomes these limitations, enabling a remarkable Ni usage reduction (Ni < 0.6) while demonstrating high capacity (215 mAh g −1 ) and markedly improved cyclability (~97% retention over 400 cycles) compared to conventional high-Ni cathodes (Ni = 0.8). Advanced X-ray and electron microscopy analyses reveal that the designed cathode exhibits a highly reversible oxygen anionic redox, benefiting from a structurally stable surface and minimizing irreversible phase transitions. Moreover, the integrated structure substantially mitigates lattice strain and improves mechanical stability even under harsh conditions. In conclusion, this advance offers a general design principle for developing next-generation cathodes that combine resource efficiency with long-term electrochemical reliability.

36 MATERIALS SCIENCE↗