Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rotary Percussive Sample Acquisition Tool (SAT): Hardware Development and Testing

In support of a potential Mars Sample Return (MSR) mission an Integrated Mars Sample Acquisition and Handling (IMSAH) architecture has been proposed to provide a means for Rover-based end-to-end sample capture and caching. A key enabling feature of the architecture is the use of a low mass sample Acquisition Tool (SAT) that is capable of drilling and capturing rock cores directly within a sample tube in order to maintain sample integrity and prevent contamination across the sample chain. As such, this paper will describe the development and testing of a low mass rotary percussive SAT that has been shown to provide a means for core generation, fracture, and capture.

Integrated Mars Sample Acquisition and Handling (I↗

Semivolatile Particulate Organic Material Southern Africa during SAFARI 2000

During August and September 2000, the University of Washington's Cloud and Aerosol Research Group (CARG) with its Convair-580 research aircraft participated in the Southern African Fire-Atmosphere Research Initiative (SAFARI) 2000 field study in southern Africa. Aboard this aircraft was a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS), which was used to determine semivolatile particulate material with a diffusion denuder sampler. Denuded quartz filters and sorbent beds in series were used to measure nonvolatile and semivolatile materials, respectively. Results obtained with the PC-BOSS are compared to those obtained with conventional quartz-quartz and Teflon-quartz filter pack samplers. Various 10-120 min integrated samples were collected during flights through the h e troposphere, in the atmospheric boundary layer, and in plumes from savanna fires. Significant fine particulate semivolatile organic compounds (SVOC) were found in all samples. The SVOC was not collected by conventional filter pack samplers and therefore would not have been determined in previous studies that used only filter pack samplers. The SVOC averaged 24% of the fine particulate mass in emissions from the fires and 36% of the fine particulate mass in boundary layer samples heavily impacted by aged emissions from savanna fires. Concentrations of fine particulate material in the atmospheric mixed layer heavily impacted by aged savanna frre emissions averaged 130 micrograms per cubic meter. This aerosol was 85% carbonaceous mated.

Eatough, D. J.↗

Returning Samples from Enceladus for Life Detection

Evidence suggests that Saturn’s icy moon Enceladus has a subsurface ocean that sources plumes of water vapor and ice vented to space from its south pole. In situ analyses of this material by the Cassini spacecraft have shown that the ocean contains key ingredients for life (elements H, C, N, O and possibly S; simple and complex organic compounds; chemical disequilibria at water-rock interfaces; clement temperature, pressure, and pH). The Cassini discoveries make Enceladus’ interior a prime locale for life detection beyond Earth. Scant material exchange with the inner Solar System makes it likely that such life would have emerged independently of life on Earth. Thus, its discovery would illuminate life’s universal characteristics. The alternative result of an upper bound on a detectable biosphere in an otherwise habitable environment would likewise considerably advance our understanding of the prevalence of life beyond Earth. Here we outline the rationale for returning vented ocean samples, accessible from Enceladus’ surface or low altitudes, to Earth for life detection. Returning samples allows analyses using laboratory instruments that cannot be flown, with decades or more to adapt and repeat analyses. We describe an example set of measurements to estimate the amount of sample to be returned and discuss possible mission architectures and collection approaches. We then turn to the challenges of preserving sample integrity and implementing planetary protection policy. We conclude by placing such a mission in the broader context of Solar System exploration.

Enceladus↗

Thresholds of Temperature and Time for Mars Sample Return: Final Report of The Mars Sample Return Temperature-Time Tiger Team

The time-temperature tiger team (T4) was chartered by NASA and ESA to evaluate the risks to the scientific return of the MSR samples if they are exposed to temperatures between +30 and +60 ⁰C for different amounts of time. This team consists of 13 scientists, who were selected based on their scientific background to represent the scientific disciplines that are expected to be the ones that will be the most affected if such heating were to happen. The expertise of the team will help to understand whether exposing the MSR samples to temperatures between +30 and +60 ⁰C will pose any risk to the sample integrity and therefore, to future scientific investigations. Key processes identified by the T4 were: the release of volatiles by desorption and sublimation and release from condensed phases (interiors, decomposition, dehydration); chemical reactions including gas-gas and gas-solid; deliquescence of hygroscopic salts; acid/base interactions (potential for extreme pH conditions); aqueous redox reactions, isotopic exchange (aqueous phases, minerals, gasses, organic phases); condensation and freezing (in the after-heating cooling phase) and interactions with the sample tube materials. There is potential for multiple interactions and overlapping effects. For inorganic materials and the records they represent, over both long time scales (hours to days) and short time scales (minutes to hours) no temperature excursion above +30 °C could be accommodated without loss of science (Figure 1.1). While there will be some robust constituents (feldspars, quartz, pyroxenes, etc.) that are unaffected, there will also be some less robust constituents (salts, phyllosilicates, radicals, etc.) that are affected across all temperature ranges ≤60 °C. For organic materials, in particular organic biosignatures, the risks reflect that preservation is reliant on a number of processes, and a change in one component within a sample tube can affect another. For organic materials, over long timescales of hours to days no temperature excursion above +30 °C could be accommodated without loss of science, but over shorter time scales (minutes to hours), raising the temperature to 40 °C could be manageable without major disruption to science, whereas temperatures above 40 °C would lead to significant losses. The consideration of these findings by the MSR team will help to maintain the fidelity of samples returned from Mars in the future and maximize scientific return when analyzed in Earth laboratories.

Mark A Sephton↗

The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

Nillen, Jeannie L.↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal Atomic Force Microscopy for the Characterization of Metallic Particulates

This study investigates the utility of multimodal, or functional, atomic force microscopy (AFM) for the characterization of individual particles and particle ensembles. In single-particle analyses, AFM imaging modes provided orthogonal insights into mechanical and magnetic properties that are not accessible through conventional electron microscopy. Although the experiments were inherently delicate and time-intensive, with an observed sample loss rate of approximately 30%, these techniques enabled the qualitative differentiation of grain structures and magnetic domains, underscoring the challenges of experimental robustness. For particle ensembles, AFM enabled the extraction of reliable 2D and 3D particle size distributions. However, efforts to chemically differentiate particles based on mechanical property contrasts were limited by scaling effects and the qualitative nature of the data. Overall, multimodal AFM offers valuable complementary information, but its application requires careful consideration of methodological limitations, particularly for sample integrity, calibration, and scalability of mechanical and magnetic measurements. This report is organized to first address the application of AFM to single-particle analysis using various imaging modalities, followed by its potential role in ensemble-level particle screening and differentiation.

36 MATERIALS SCIENCE↗

Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

Generating the desired solute concentration signal in micro-environments is vital to many applications ranging from micromixing to analyzing cellular response to a dynamic microenvironment. We propose a new modular design to generate targeted temporally varying concentration signals in microfluidic systems while minimizing perturbations to the flow field. The modularized design, here referred to as module-fluidics, similar in principle to interlocking toy bricks, is constructed from a combination of two building blocks and allows one to achieve versatility and flexibility in dynamically controlling input concentration. The building blocks are an oscillator and an integrator, and their combination enables the creation of controlled and complex concentration signals, with different user-defined time-scales. We show two basic connection patterns, in-series and in-parallel, to test the generation, integration, sampling and superposition of temporally-varying signals. All such signals can be fully characterized by analytic functions, in analogy with electric circuits, and allow one to perform design and optimization before fabrication. Such modularization offers a versatile and promising platform that allows one to create highly customizable time-dependent concentration inputs which can be targeted to the specific application of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Errors in hybrid computers

Method is described for reduction of error components in numerical integration, sampling with zero hold order, and execution time delay.

Alford, C. O.↗

Organic contamination problems in the Viking molecular analysis experiment

A principal problem in interpreting the results of an organic analysis of an extraterrestrial sample is that of distinguishing contaminating material from indigenous material when unknown types and amounts of contaminants make their way into the sample being analyzed. An approach to control of sample integrity in the Viking molecular analysis experiment has been devised which it is believed, will eliminate such problems. Basically this involves (1) placing an upper limit on the amount of terrestrial contamination that can be tolerated and still allow scientifically meaningful analysis, (2) identifying the potential sources of contamination and analyzing their relative significance, (3) establishing methods to control these sources, and (4) obtaining complete information on the chemical composition of potential contaminants. Previous experience in the Apollo mission has been of great value in developing the Viking program, perhaps the most important carryover being the recognition of the importance of establishing a comprehensive contamination control program in the early stages of mission planning and hardware design.

Flory, D. A.↗

Si:Bi switched photoconducttor infrared detector array

A multiplexed infrared detector array is described. The small demonstration prototype consisted of two cryogenically cooled, bismuth doped silicon, extrinsic photoconductor pixels multiplexed onto a single output channel using an on focal plane switch integration sampling technique. Noise levels of the order of 400 to 600 rms electrons per sample were demonstrated for this chip and wire hybrid version.

Eakin, C. E.↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

A CCD System for Photometry of Direct and Spectroscopic Images

A charge-coupled device (CCD) for direct imagery at the focus of a ground-based telescope and for high dispersion spectroscopy of stars is evaluated. The CCD is an RCA SID 53612 thinned, buried channel array of 512x320 30-micron square pixels that are back-illuminated and refrigerated to about -60 C in a rugged, RF-shielded vacuum housing. The double-correlated sampling (integrator) readout system, the Z80 microprocessor readout control system, and the data collection system are described. The readout noise is 120 electron-hole pairs (ehp) per pixel per readout, the thermal dark current is 50 ehp/pixel/sec, and the scale of the 12-bit analog-to-digital converter is 25 ehp/AD unit. Unique features of this system are compared to other astronomical implementations of the same model of CCD.

Frecker, J. E.↗

Core saturation in a moving medium

A numerical technique for solving the line transfer equation of a two-level atom in static equilibrium is presented. Complete redistribution of emitted photons is assumed, as is saturation at the line core. Emission intensity is calculated either by a generalized Eddington-Barber relation, a first-order differential equation for the specific intensity, or by a formal transfer integral. Sample calculations are performed of the line transfer equation in a semi-infinite atmosphere with a constant Planck function of the collision parameter and for the Mg II resonance line in a model solar atmosphere experiencing shocks. Attention is focused on the line wings in the latter problem. The first order differential equation approach yields the best intensity values and temperature structure.

Kalkofen, W.↗

Pi/4-QPSK modems for satellite sound/data broadcast systems

The use of pi/4-quadrature phase-shift keying (QPSK) modems for satellite sound broadcast systems (SSBS) broadcasting to mobile or portable receivers is proposed. Three different differential detectors (including the FM-discriminator followed by integrate-sample-and-dump filter) and a novel coherent detector are discussed. The degradation caused by the frequency offset between the local oscillator (LO) and the unmodulated carrier (CR) in the baseband differential detector is studied. The performance of both coherently and differentially detected pi/4-QPSK in a Gaussian channel is also studied. It is shown that with a frequency offset of more than 3 percent of the symbol rate, the performance degradation is more than 1 dB at 0.0001. The out-of-band power of the nonlinearly amplified bandlimited pi/4-QPSK signals is reduced from -13 dB to -37 dB if a 2-dB output back-off amplifier is used instead of a hardlimiter. The performance of the pi/4-QPSK is equivalent to that of QPSK, although the pi/4-QPSK has the advantage of less spectrum restoration after nonlinear amplification. The coherent demodulator and differential decoder avoid the three-level detection and achieve the same bit-error-rate performance as DEQPSK with a simple circuit.

Liu, Chia-Liang↗

Readying advanced composites for the microscope

Concerns related to the proper preparation of composite specimens for microstructural analysis are examined. Proper preparation will minimize the amount of surface and subsurface damage at each stage of the procedure so that the microstructural features of the final-polished specimen can be accurately determined as a function of the composite's response to processing, testing, or service conditions. This requires that an optimum combination of abrasive type, size, and bond be applied during each grinding, lapping, and polishing step. Machine settings, such as polishing speed, force, and relative polishing direction, are also important. Guidelines are given for each step of the six-stage specimen preparation process: sectioning, planar grinding, sample integrity, polishing, and etching.

Zipperian, Donald C.↗

A study of low emissions gas turbine combustions

Analytical studies have been conducted to determine the best methods of reducing NO(x) emissions from proposed civilian supersonic transports. Modifications to the gas turbine engine combustors and the use of additives were both explored. It was found that combustors which operated very fuel rich or lean appear to be able to meet future emissions standards. Ammonia additives were also effective in removing NO(x), but residual ammonia remained a problem. Studies of a novel combustor which reduces emissions and improves performance were initiated. In a related topic, a study was begun on the feasibility of using supersonic aircraft to obtain atmospheric samples. The effects of shock heating and compression on sample integrity were modeled. Certain chemical species, including NO2, HNO3, and ClONO2 were found to undergo changes to their composition after they passed through shock waves at Mach 2. The use of detonation waves to enhance mixing and combustion in supersonic airflows was also investigated. This research is important to the use of airbreathing propulsion to obtain orbital speeds and access to space. Both steady and pulsed detonation waves were shown to improve engine performance.

Adelman, Henry G.↗

Field intercomparison of a novel optical sensor for formaldehyde quantification

A one-week in situ intercomparison campaign was completed on the Rice University campus for measuring HCHO using three different techniques, including a novel optical sensor based on difference frequency generation (DFG) operating at room temperature. Two chemical derivatization methods, 2,4-dinitrophenylhydrazine (DNPH) and o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA), were deployed during the daylight hours for three- to four-hour time-integrated samples. A real-time optical sensor based on laser absorption spectroscopy was operated simultaneously, including nighttime hours. This tunable spectroscopic source based on difference frequency mixing of two fiber-amplified diode lasers in periodically poled LiNb03 (PPLN) was operated at 3.5315 micrometers (2831.64 cm 1) to access a strong HCHO ro-vibrational transition free of interferences from other species. The results showed a bias of -1.7 and -1.2 ppbv and a gross error of 2.6 and 1.5 ppbv for DNPH and PFBHA measurements, respectively, compared with DFG measurements. These results validate the DFG sensor for time-resolved measurements of HCHO in urban areas.

NASA Discipline Life Sciences Technologies↗