Search NASA⌕ Search

SEARCH · Search NASA

Results for “setback”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Competing Use Analysis for Offshore Renewables and Subsea Cables

Demand for abundant and diverse resources in the oceans is growing, necessitating marine spatial planning. To inform development of Marine Hydrokinetic (MHK) and Offshore Wind (OSW) resources, the Department of Energy (DOE) has asked NREL to identify the competing uses areas between promising MHK/OSW sites and submarine power and telecommunications cables. The first step in this work is to identify and quantify the overlap between the MHK/OSW resource availability and existing cable routes. The analysis is done in terms of resource area because the task of quantifying actual impacts on available resource is a non-trivial undertaking that involves subjective decisions of identifying resource opportunities. Quantifying overlap in-terms of resource area?on the other hand?is significantly more straight forward, and useful to marine spatial planners. This dataset of polygons describes recommended setback areas from submarine cables for marine renewable energy Development. Two archive files are provided: 1. NREL Cables Setback-Polygons.zip contains the following GeoJSON files: 1.a. cables_100ft.geojson: The Code of Federal Regulations (CFR 585.301) specifies that the legal right of way for submarine cables is 100 ft (~30 meters) to either side of the cable (i.e., 200 ft wide). 1.b. cables_2z.geojson: The International Cable Protection Committee (ICPC) of the North American Submarine Cable Association (NASCA) recommends setback distances for new facilities as the maximum of 500 m or twice the bottom depth (2z), per ICPC Recommendation 13 No. 2 (Communications Security, Reliability and Interoperability Council IV 2014). For depths 250 m, 2 * depth is to be used. 1.c. cables_3z.geojson: The ICPC of NASCA recommends setback distances for new cables as the maximum of 500 m or three times the bottom depth (3z), per ICPC Recommendation 2 No. 10 (Communications Security, Reliability and Interoperability Council IV 2014). So for depths 167 m, 3 * depth is to be used. 2. NREL Submarine Cable Analysis Code Data Presentations.zip contains all files (code, data, README, etc) from release 0.1 of this Github repository for possibly regenerating the product as submarine cable configurations change: https://github.com/ecoquants/nrel-cables. For more details, please see the link to the full report for which this data product is a supplemental output: Submarine Cable Analysis for U.S. Marine Renewable Energy Development by Ben Best and Levi Kilcher National Renewable Energy Laboratory

16 TIDAL AND WAVE POWER↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Martha's Vineyard, Massachusetts

This report presents a cold climate project that examines the relationships among very energy efficient single-family residential thermal enclosures, room-to-room temperature variations, and simplified space conditioning systems. The project was developed, designed, and built by South Mountain Company and is located in West Tisbury, Massachusetts, on the island of Martha’s Vineyard. This project allowed investigators to compare room-to-room temperatures in four virtually identical houses that were all built to the same construction standard. Each of the four all-electric homes has a single ductless heat pump unit (DHU) located in the main living space with a single programmable thermostatic control built into the unit. Each bedroom and the main bathroom have radiant electric resistance panels with individual nonprogrammable thermostatic controls that occupants can turn on and off for their comfort. Results indicate that temperature fluctuations in the living room resulting from aggressive setup and setback of the DHU may contribute to fewer hours when the bedroom temperatures are within ±2°F of the living room temperatures, compared to houses without setback. Solar gains in the living room, along with opening and closing doors, appear to have a significant impact on room-to-room temperature differences, as would be expected. Setback strategies do not appear to save energy but do contribute to significant temperature variations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Justifications for Liquid Hydrogen Exposure Distances

The previous separation distances in the National Fire Protection Association (NFPA) Hydrogen Technologies Code (NFPA 2, 2020 Edition) for bulk liquid hydrogen systems lack a well-documented basis and can be onerous. This report describes the technical justifications for revisions of the bulk liquid hydrogen storage setback distances in NFPA 2, 2023 Edition. Distances are calculated based on a leak area that is 5% of the nominal pipe flow area. Models from the open source HyRAM+ toolkit are used to justify the leak size as well as calculate consequence-based separation distances from that leak size. Validation and verification of the numerical models is provided, as well as justification for the harm criteria used for the determination of the setback distances for each exposure type. This report also reviews mitigations that could result in setback distance reduction. The resulting updates to the liquid hydrogen separation distances are well-documented, retrievable, repeatable, revisable, independently verified, and use experimental results to verify the models.

08 HYDROGEN↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts (Fact Sheet)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency, which faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68°F) than day (73° F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

ARIES↗

Effects of land-based wind turbine upsizing on community sound levels and power and energy density

Multiple technological, social, and market factors of wind power are evolving rapidly. Most notably, significant wind turbine scaling is occurring and is forecasted to continue. While the larger turbines expected to be deployed in the future are more powerful and efficient, they are also expected to operate at higher sound levels and require larger setbacks than those installed in the last decade. These sometimes-competing deployment trends and impacts cannot be understood via simple extrapolations of past trends. This study analyzes the effect of these future larger turbines on wind turbine micro-siting, project-level power and energy density, and community noise impacts. Due to their taller heights, larger rotors, and higher sound power levels, future wind turbines will require larger setbacks from homes and greater inter-turbine spacing, resulting in fewer turbines deployed for a given land area. This research finds these changes more than offset the effect of the higher turbine sound emissions, significantly decreasing the average sound levels that wind plant hosting communities experience. Yet, simultaneously, plant layouts using future turbine designs also result in projects with higher installed capacities and annual energy output for a given land area. These increases will likely lead to increased tax benefits and local income in the community. The deployment of fewer turbines on a smaller number of parcels could have implications on siting flexibility and landowner payments.

17 WIND ENERGY↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

LiCaAIF 6 :Eu Scintillator Family Neutron Detection (Final Report)

The proposed work was based on a learning cycle format with three parts, (1) Modeling, (2) Growth, (3) Characterization, to investigate the family of colquiriite scintillators and various activating dopants as efficiently and effectively as possible. Under this research methodology, each of these functions would feed information to the next. Each iteration around the cycle was expected to improve results and provide clues to the best path forward for the next iteration. However, it was realized that this research model is not robust and unable to handle setbacks at any one of the functions. Unfortunately, the project suffered setbacks in the “Growth” function and progress in the other functions was severely restricted. Of course, numerous alternative paths were trialed within the growth function to enable progress, but these required addition time and resources which in the end only provided limited progress. After reviewing the project as a whole, it can be concluded that the research model used was indeed too fragile for this sort of research and a more robust plan should be utilized in the future. As a whole though, significant progress was made toward understanding the barriers toward realizing the benefits of this family of scintillators through modeling. Various paths forward were postulated, but limited growth and synthesis capabilities prevented experimental validation. Experimentally, it was found that the synthesis and growth of colquiriite scintillators requires special considerations for its thermodynamic and chemical properties. These were overcome in the end and a new, lower cost growth method realized, but too late to have a significant impact in validating modeling hypotheses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

H2FIRST Reference Station Design Task: Project Deliverable 2-2

This report presents near-term station cost results and discusses cost trends of different station types. It compares various vehicle rollout scenarios and projects realistic near-term station utilization values using the station infrastructure rollout in California as an example. It describes near-term market demands and matches those to cost-effective station concepts. Finally, the report contains detailed designs for five selected stations, which include piping and instrumentation diagrams, bills of materials, and several site-specific layout studies that incorporate the setbacks required by NFPA 2, the National Fire Protection Association Hydrogen Technologies Code. This work identified those setbacks as a significant factor affecting the ability to site a hydrogen station, particularly liquid stations at existing gasoline stations. For all station types, utilization has a large influence on the financial viability of the station.

30 DIRECT ENERGY CONVERSION↗

Final Technical Report for GO17004 Regulatory Logic: Codes and Standards for the Hydrogen Economy

The objectives of this project are to: develop a robust supporting research and development program to provide critical hydrogen behavior data and a detailed understanding of hydrogen combustion and safety across a range of scenarios, needed to establish setback distances in building codes and minimize the overall data gaps in code development; support and facilitate the completion of technical specifications by the International Organization for Standardization (ISO) for gaseous hydrogen refueling (TS 20012) and standards for on-board liquid (ISO 13985) and gaseous or gaseous blend (ISO 15869) hydrogen storage by 2007; support and facilitate the effort, led by the NFPA, to complete the draft Hydrogen Technologies Code (NFPA 2) by 2008; with experimental data and input from Technology Validation Program element activities, support and facilitate the completion of standards for bulk hydrogen storage (e.g., NFPA 55) by 2008; facilitate the adoption of the most recently available model codes (e.g., from the International Code Council [ICC]) in key regions; complete preliminary research and development on hydrogen release scenarios to support the establishment of setback distances in building codes and provide a sound basis for model code development and adoption; support and facilitate the development of Global Technical Regulations (GTRs) by 2010 for hydrogen vehicle systems under the United Nations Economic Commission for Europe, World Forum for Harmonization of Vehicle Regulations and Working Party on Pollution and Energy Program (ECE-WP29/GRPE); and to Support and facilitate the completion by 2012 of necessary codes and standards needed for the early commercialization and market entry of hydrogen energy technologies.

08 HYDROGEN↗

Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites

Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) is a project initiated by the DOE in 2015 and executed by Sandia National Laboratories and the National Renewable Energy Laboratory to address R&D barriers to the deployment of hydrogen fueling infrastructure. One key barrier to the deployment of fueling stations is the land area they require (i.e. "footprint"). Space is particularly a constraint in dense urban areas where hydrogen demand is high but space for fueling stations is limited. This work presents current fire code requirements that inform station footprint, then identifies and quantifies opportunities to reduce footprint without altering the safety profile of fueling stations. Opportunities analyzed include potential new methods of hydrogen delivery, as well as alternative placements of station technologies (i.e. rooftop/underground fuel storage). As interest in heavy-duty fueling stations and other markets for hydrogen grows, this study can inform techniques to reduce the footprint of heavy-duty stations as well. This work characterizes generic designs for stations with a capacity of 600 kg/day hydrogen dispensed and 4 dispenser hoses. Three base case designs (delivered gas, delivered liquid, and on-site electrolysis production) have been modified in 5 different ways to study the impacts of recently released fire code changes, colocation with gasoline refueling, alternate delivery assumptions, underground storage of hydrogen, and rooftop storage of hydrogen, resulting in a total of 32 different station designs. The footprints of the base case stations range from 13,000 to 21,000 ft 2 . A significant focus of this study is the NFPA 2 requirements, especially the prescribed setback distances for bulk gaseous or liquid hydrogen storage. While the prescribed distances are large in some cases, these setback distances are found to have a nuanced impact on station lot size; considerations of the delivery truck path, traffic flow, parking, and convenience store location are also important. Station designs that utilize underground and rooftop storage can reduce footprint but may not be practical or economical. For example, burying hydrogen storage tanks underground can reduce footprint, but the cost savings they enable depend on the cost of burial and the cost land. Siting and economic analysis of station lot sizes illustrate the benefit of smaller station footprints in the flexibility and cost savings they can provide. This study can be used as a reference that provides examples of the key design differences that fueling stations can incorporate, the approximate sizes of generic station lots, and considerations that might be unique to particular designs.

08 HYDROGEN↗

Assessment of Offshore Wind Energy Leasing Areas for Humboldt and Morro Bay Wind Energy Areas, California

The National Renewable Energy Laboratory (NREL) is providing scientific and technical services to the Bureau of Ocean Energy Management (BOEM) under an interagency agreement. The purpose of this report is to provide technical assistance in delineating potential lease areas from the California wind energy areas (WEAs) that can be competitively auctioned to wind energy developers. Each wind energy area is presumed to be technically and economically feasible for wind energy development based on the economic cost study performed by NREL in 2020. The subsequent analysis summarized in this report is intended to help BOEM maximize efficient offshore wind energy resource use and ensure fair return to the Government for use of the lease areas, by making recommendations for viable ways to divide the WEAs into auctionable commercial lease areas of approximately equal value. We considered several factors that affect the value of lease areas for wind energy development, including mean wind speeds, water depth, seafloor gradient, seismicity, hard substrate, and access to infrastructure. The largest impact to generating capacity came from the choice of mooring technology and the resulting setback from the lease area boundaries. Based on our setback assumptions, the generating capacity for a wind plant using catenary moorings could be nearly 30% less than with vertical moorings in Humboldt, or approximately 20% less in Morro Bay. The likely range of generating capacity is 1.5 to 3 GW in Humboldt and 3 to 5 GW in Morro Bay.

17 WIND ENERGY↗

Challenges in Implementing a Multi-Partnership Geothermal Power Plant

The UND-CLR binary geothermal power plant project is a piggyback operation on a secondary-recovery water-flood project in the Cedar Hills oil field in the Williston Basin. Two open-hole horizontal wells at 2,300 m and 2,400 m depths with lateral lengths of 1,290 m and 860 m produce water at a combined flow of 51 l s -1 from the Lodgepole formation (Miss.) for injection into the Red River formation (Ordovician). The hydrostatic head for the Lodgepole is at ground surface and the pumps, which are set at 650 m depth, have run continuously since 2009. Water temperature at the wellhead is 103 °C and CLR passes the water through two large air-cooled heat exchangers prior to injection. In all aspects, the CLR water flood project is ideal for demonstration of electrical power production from a low-temperature geothermal resource. However, implementation of the project from concept to power production was analogous to breaking trail in deep snow in an old growth forest. There were many hidden bumps, detours, and in some instances immoveable barriers. Problems with investors, cost share, contracts with CLR, resistance from local industry, cost of installation, delays by the ORC supplier, and the North Dakota climate all caused delays and setbacks. Determination and problem solving by the UND team eventually overcame most setbacks, and in April 2016, the site began generating power. Figure 1: Schematic of the water supply well at the UND CLR binary geothermal power plant REFERENCES Williams, Snyder, and Gosnold, 2016, Low Temperature Projects Evaluation and Lesson Learned, GRC Transactions, Vol. 40, 203-210 Gosnold, LeFever, Klenner, Mann, Salehfar, and Johnson, 2010, Geothermal Power from Coproduced Fluids in the Williston Basin, GRC Transactions, Vol. 34, 557-560

Coproduced, geothermal, binary power↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate: Preprint

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Turbine scale and siting considerations in wind plant layout optimization and implications for capacity density

Improvements in wind energy technology, reduced costs, and ambitious clean energy goals have led to projections of high wind contribution in coming years. Developing methodologies to design wind plants with a variety of siting constraints and turbine sizes helps enable high wind penetration, and gain a better understanding of how wind plants are sensitive to setback constraints and turbine design. In this paper, we present a two-step optimization method to simultaneously determine the optimal number of turbines and their locations in a wind plant domain divided into many small, discrete parcels. We present the optimized performance metrics of a wind plant optimized with different turbine sizes and ratings, and with different siting restrictions within the wind plant. Our results indicate that taller and larger turbines are more sensitive to increasing siting constraints. We also compare the optimal wind plant layouts and performance for wind plants optimized for minimum COE and maximum profit. Wind plants optimized for profit had 130%-190% of the capacity of plants optimized for COE, which demonstrates that the optimal results are greatly affected by the objective function, which should be carefully considered. Finally, in this paper we demonstrate the effect of increasing siting constraints on wind plant capacity density, and how the results change when different land areas are used to calculate capacity density. When using the entire wind plant boundary area to determine capacity density, increasing siting constraints decreases the capacity density. However, when we only use the available area (the area left after removing the siting constraints) to calculate the capacity density, increasing the siting constraints increases capacity density. This is a critical insight because of how capacity density is typically defined and used in research, and has important implications for assessment of technical potential and capacity expansion modeling, as well as future wind deployment potential.

17 WIND ENERGY↗

Deploying advanced supervisory control strategies to small- and medium-sized commercial buildings: Case study and lessons learned

Deploying advanced supervisory control strategies (ASCSs) in small- and medium-sized commercial buildings (SMBs) is vital but faces two issues: (1) a lack of building control and communication infrastructure (BCCI) in SMBs and (2) the significant engineering efforts required to implement and configurate ASCSs. Despite hindering the large-scale adoption of ASCSs in SMBs, these issues have not been adequately explored in the literature, which tends to focus more on feasibility than scalability. This paper provides a comprehensive evaluation of these two issues through a case study of an occupied SMB in eastern Tennessee of the United States. Specifically, we design and implement a BCCI for the studied building with commercial off-the-shelf products to accommodate the needs for deploying ASCSs. Here, we then deploy two ASCSs—a rule-based setback control and a model predictive control (MPC)—with the BCCI and evaluate their performance throughout the summer of 2024. This study reveals that the main bottlenecks in establishing BCCIs for SMBs are the high initial cost (∼$56/m 2 ) and communication delays (up to 9 min). Additionally, the assessment of the two ASCSs indicates that the majority (∼75 %) of the engineering effort required for implementation and configuration is spent on model identification, debugging, and tuning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗