Search NASA⌕ Search

SEARCH · Search NASA

Results for “shaker test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of the Semi-Empirical Force-Limiting Approach for the CoNNeCT SCAN Testbed

The semi-empirical force-limiting vibration method was developed and implemented for payload testing to limit the structural impedance mismatch (high force) that occurs during shaker vibration testing. The method has since been extended for use in analytical models. The Space Communications and Navigation Testbed (SCAN Testbed), known at NASA as, the Communications, Navigation, and Networking re-Configurable Testbed (CoNNeCT), project utilized force-limiting testing and analysis following the semi-empirical approach. This paper presents the steps in performing a force-limiting analysis and then compares the results to test data recovered during the CoNNeCT force-limiting random vibration qualification test that took place at NASA Glenn Research Center (GRC) in the Structural Dynamics Laboratory (SDL) December 19, 2010 to January 7, 2011. A compilation of lessons learned and considerations for future force-limiting tests is also included.

Staab, Lucas D.↗

Using Multi-shaker Force Control Methods in Modal Analysis

Shaker excitation is a popular technique in experimental modal analysis because it gives the practitioner a high level of control and repeatability in the excitation. However, the dynamics of the shaker and test article can fundamentally limit the excitation bandwidth when a voltage-mode amplifier is used to power the shaker. Further, multiple shakers can couple to one-another through the test article and correlate the forces during a multiple-input / multiple-output modal test, potentially impa

Carter, Steven Phillip↗

Capabilities of electrodynamic shakers when used for mechanical shock testing

The results of a research task to investigate the capabilities of electrodynamic vibrators (shakers) to perform mechanical shock tests are presented. The simulation method employed was that of developing a transient whose shock response spectrum matched the desired shock response spectrum. Areas investigated included the maximum amplitude capabilities of the shaker systems, the ability to control the shape of the resultant shock response spectrum, the response levels induced at frequencies outside the controlled bandwidth, and the nonlinearities in structural response induced by a change in test level.

Keegan, W. B.↗

Force Limited Vibration Testing Monograph

The practice of limiting the shaker force in vibration tests was instigated at the NASA Jet Propulsion Laboratory (JPL) in 1990 after the mechanical failure of an aerospace component during a vibration test.

Vibration↗

Balancing Impedance and Controllability in Response Reconstruction

One concept in smart dynamic testing is to match the impedance that a component experiences between test and the environment of interest, but this begs the question: how much of an impedance match is needed and could there be too much? In a prior work, the authors performed MIMO testing with a small component connected to various assemblies, each of which had a differing degree of similarity to the actual flight boundary conditions. The results showed that the fidelity of the response at locations away from the control accelerometers was highly sensitive to the impedance. This work presents further case studies to explore these ideas. Subsequent tests are presented for an assembly that presumably matched the impedance even better, and which was also much more flexible, and the results obtained are even worse than when no attention was given to the impedance. Hence, the work presented here suggests that one should seek a balance between 1.) matching the impedance and 2.) improving the controllability of the component of interest. The concepts are explored using both test data of a benchmark component, for which the environment of interest was recorded as the component flew on a sounding rocket.

Shaker Test, Operational Vibration Environment, Su↗

Shaker-structure interaction modeling and analysis for nonlinear force appropriation testing

Nonlinear force appropriation is an extension of its linear counterpart where sinusoidal excitation is applied to a structure with a modal shaker and phase quadrature is achieved between the excitation and response. While a standard practice in modal testing, modal shaker excitation has the potential to alter the dynamics of the structure under test. Previous studies have been conducted to address several concerns, but this work specifically focuses on a shaker-structure interaction phenomenon which arises during the force appropriation testing of a nonlinear structure. Under pure-tone sinusoidal forcing, a nonlinear structure may respond not only at the fundamental harmonic but also potentially at sub- or superharmonics, or it can even produce aperiodic and chaotic motion in certain cases. Shaker-structure interaction occurs when the response physically pushes back against the shaker attachment, producing non-fundamental harmonic content in the force measured by the load cell, even for pure tone voltage input to the shaker. This work develops a model to replicate these physics and investigates their influence on the response of a nonlinear normal mode of the structure. Experimental evidence is first provided that demonstrates the generation of harmonic content in the measured load cell force during a force appropriation test. This interaction is replicated by developing an electromechanical model of a modal shaker attached to a nonlinear, three-mass dynamical system. Several simulated experiments are conducted both with and without the shaker model in order to identify which effects are specifically due to the presence of the shaker. Finally, the results of these simulations are then compared to the undamped nonlinear normal modes of the structure under test to evaluate the influence of shaker-structure interaction on the identified system’s dynamics.

42 ENGINEERING↗

Rapid, Approximate Multi-Axis Vibration Testing [Thesis]

The aerospace industry uses vibration shaker tables to perform component durability testing. In these tests a component, piece of equipment, or entire system is attached to a shaker table where it is subjected to dynamic excitation. The goal is to understand how the article under test will perform in its service environment without having to run it through its entire service life via field testing. In a vibration test, an aerospace system or component is qualified if it is shown to survive a test meant to replicate its lifetime service conditions. The test is designed based on recorded field data. To develop a test, a system is taken through all of its intended environments, e.g., transportation, launch, and reentry. Acceleration data measured from these environments is then brought back to the lab and imported into a shaker table controller. The controller then drives a vibration test intended to mimic the acceleration conditions experienced by the system or specific components of the system in the field. However, it is often difficult to match the measured field response in a lab test. This is largely due to the test’s boundary conditions and excitation methods. In a lab test, a shaker table is the excitation source. The two most common shaker table types, differentiated by their number of independent degrees of freedom, are single-axis and multi-axis shaker tables. Multi-axis shakers have the ability to reproduce service environments more realistically, as real accelerations inevitably produce multiple degrees of freedom of excitation simultaneously. Figure 1 depicts a generic multi-axis testing setup on a three-axis shaker table. Often multi-axis tests use six-degree-of-freedom (6DOF) shaker tables. Yet multi-axis shakers are not yet common in the aerospace industry due in part to their high cost and the difficulty for shaker controllers to handle the added complexity. Single-axis shaker tables are much more common. They are not as expensive to purchase and have a wide range of control software options.

42 ENGINEERING↗

A method for experimental modal separation

A method is described for the numerical simulation of multiple-shaker modal survey testing using simulated experimental data to optimize the shaker force-amplitude distribution for the purpose of isolating individual modes of vibration. Inertia, damping, stiffness, and model data are stored on magnetic disks, available by direct access to the interactive FORTRAN programs which perform all computations required by this relative force amplitude distribution method.

Hallauer, W. L., Jr.↗

Force Limited Vibration Testing Monograph

The practice of limiting the shaker force in vibration tests was investigated at the NASA Jet Propulsion Laboratory (JPL) in 1990 after the mechanical failure of an aerospace component during a vibration test. Now force limiting is used in almost every major vibration test at JPL and in many vibration tests at NASA Goddard Space Flight Center (GSFC) and at many aerospace contractors. The basic ideas behind force limiting have been in the literature for several decades, but the piezo-electric force transducers necessary to conveniently implement force limiting have been available only in the last decade. In 1993, funding was obtained from the NASA headquarters Office of Chief Engineer to develop and document the technology needed to establish force limited vibration testing as a standard approach available to all NASA centers and aerospace contractors. This monograph is the final report on that effort and discusses the history, theory, and applications of the method in some detail.

Scharton, Terry D.↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

NASA Engineering and Safety Center Technical Bulletin No. 15-02: Best Practices for Use of Sine Burst Testing

Sine Burst (SB) Testing is used for strength testing of aerospace hardware as an alternate to static pull and centrifuge tests. The main advantage is that testing can be implemented while hardware is on the shaker for other tests. It also imposes a lower number of cycles on the hardware compared with a sine dwell or sweep, and is particularly suitable for relatively stiff components or electronics boxes, instruments, or spacecraft. Identified risks can be mitigated by best practices.

Best Practices↗

A simulation study of test fixture attachment points for vibration test optimization (MEEN 5440 Final Project)

The aerospace industry uses vibration shaker tables to perform component durability testing. These dynamic environments tests often have a hard time replicating the service environment of a component due to a mismatch in the applied force or the boundary condition. Figure 1 shows the desired outcome of a dynamic environments test. The measured responses in a lab test, ideally, should match the measured response of the service environment field test. One way to address the mismatch between field environment and lab environment is with test fixture design. The test fixture attaches the component under test to the shaker table. Single-axis shakers are the industry standard type of shaker table, and, therefore, test fixtures are often rigid in order to minimize cross-axis responses.

42 ENGINEERING↗

A Simplified Method for Predicting Shaker Voltage in IMMATs

Impedance Matched Multi-Axis Tests (IMMATs) can replicate in-service vibration induced stress more accurately than single axis shaker table tests as they can better match a part’s operational boundary conditions and excite it in multiple degrees of freedom simultaneously. Here, the shakers used in IMMATs are less powerful than shaker tables, so shaker force limits can be exceeded during tests if they are not placed adequately for the desired environment. The ability to predict shaker voltage and force before performing a test is, therefore, helpful in selecting shaker locations so that their limits are not exceeded. In this study, electrodynamic shakers were modeled as discrete electromechanical systems, and the shaker parameters were chosen to match experimentally obtained acceleration/voltage frequency response functions (FRFs). These models were coupled to a finite element model of the device under test (DUT) via dynamic substructuring, and the substructured model was demonstrated to accurately predict shaker voltage as well as the error in reproducing the environment at multiple accelerometer locations. A simple method called the FRF Multiplication method, in which the FRF of the substructured system is approximated as the product of two separate FRFs of the shaker and DUT respectively, was proposed and applied to the same system, yielding similar voltage and error predictions to those obtained using substructuring. Simple case studies were presented to explore the applicability of the proposed method, and it was demonstrated to have similar accuracy to the substructuring method in a range of cases. Additionally, we showed that while it was not possible to derive a unique model of the shakers from acceleration/voltage FRFs alone, the models that could be obtained were sufficient to predict test error almost perfectly and shaker voltage with less than 40 percent error.

42 ENGINEERING↗

Green Run Modal Test of the NASA Space Launch System Core Stage

The Core Stage of the new NASA Space Launch System (SLS) is a 212-foot tall rocket assembly—consisting primarily of two fuel tanks, an engine section, and four RS-25 rocket engines—capable of sending crew and large payloads to the moon and beyond with 1.6 million pounds of thrust. Currently, the Core Stage is in the B2 Test Stand at Stennis Space Center, undergoing a series of structural and functional tests, designated the Green Run test series. The ultimate goal of Green Run is to verify analytical models and confirm proper subsystem operation of the Core Stage. In January 2020, Green Run testing began with an experimental modal analysis test performed by the Marshal Space Flight Center modal test team. The desired free boundary condition of the Core Stage was achieved by suspending the massive spacecraft from the B2 Test Stand crane. Modal excitation was provided by a pair of 250-lb electro-dynamic shakers for multi-shaker random vibration testing, as well as a 12-pound impact hammer for impact testing. Modal response was measured with 550 accelerometers channels distributed on both the Core Stage and the B2 Test Stand crane. Following one very long night of testing, frequency response functions were calculated from the measured time histories in the target mode frequency range of 2.5 Hz to 15 Hz, and mode shapes, frequencies, and damping values were successfully extracted. The case-study presented in this paper will discuss the SLS Core Stage, the modal test setup and procedure, as well as a brief overview of the test results. Challenges associated with testing such a large, suspended structure in an outdoor environment will be discussed as well.

Green Run↗