Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron X-ray diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

X-Ray Exposure of Electron-Deposited Photoresist for Conformal Lithography on Corrugated Surfaces

Proximity printing using synchrotron X-ray lithography provides high resolution pattern transfer with large depth of field, low diffraction effects and no reflection from the substrate. Electro-plating of photo-resist allows deposition of thin, uniform films over geometrically complex and topographically diverse, electrically conductive surfaces.

Electron-deposited resist X-ray lithography Deep d↗

Ultrapressure materials science

Three active areas of research at ultra pressure are pursued, i.e., diffraction studies with the Cornell High Energy Synchrotron Source (CHESS), band gap and absorption edge effects, indentor-anvil experiments and theory and research to attain higher pressures. The range over which X-ray diffraction data and absorption edge data are obtained is extended to 700 kbars. Using the indentor technique pressures of 2.1 Mbars are obtained. Research results and methods are discussed.

Ruoff, A. L.↗

Center for the development of commercial crystal growth in space

The second year of operation of the Center for Commercial Crystal Growth in Space is described. This center is a consortium of businesses, universities and national laboratories. The primary goal of the Center's research is the development of commercial crystal growth in space. A secondary goal is to develop scientific understanding and technology which will improve commercial crystal growth on earth. In order to achieve these goals the Center's research is organized into teams by growth technique; melt growth, solution growth, and vapor growth. The melt growth team is working on solidification and characterization of bulk crystals of gallium arsenide and cadmium telluride. They used high resolution X-ray topography performed at the National Synchrotron Light Source at Brookhaven National Laboratory. Streak-like features were found in the diffraction images of semi-insulating undoped LEC GaAs. These were shown to be (110) antiphase boundaries, which have not been reported before but appear to be pervasive and responsible for features seen via less-sensitive characterization methods. The results on CdTe were not as definitive, but indicate that antiphase boundaries may also be responsible for the double peaks often seen in X-ray rocking curves of this material. A liquid encapsulated melt zone system for GaAs has been assembled and techniques for casting feed rods developed. It was found that scratching the inside of the quartz ampoules with silicon carbide abrasive minimized sticking of the GaAs to the quartz. Twelve floating zone experiments were done.

Wilcox, William R.↗

X-Ray Topography of Tetragonal Lysozyme Grown by the Temperature-Controlled Technique

Growth-induced defects in lysozyme crystals were observed by white-beam and monochromatic X-ray topography at the National Synchrotron Light Source (NSLS) at the Brookhaven National Laboratory (BNL). The topographic methods were non-destructive to the extent that traditional diffraction data collection could be performed to high resolution after topography. It was found that changes in growth parameters, defect concentration as detected by X-ray topography, and the diffraction quality obtainable from the crystals were all strongly correlated. In addition, crystals with fewer defects showed lower mosaicity and higher diffraction resolution as expected.

Stojanoff, V.↗

Lunar and Planetary Science XXXV: Interplanetary Dust and Aerogel

Contents include the following: Isotopically Primitive Interplanetary Dust Particles of Cometary Origin: Evidence from Nitrogen Isotopic Compositions. The Solar Nebula s First Accretionary Particles (FAPs) Are They Preserved in Collected Interplanetary Dust Samples? On the Origin of GEMS. An Analytical SuperSTEM for Extraterrestrial Materials Research. Sub-Micrometer Scale Minor Element Mapping in Interplanetary Dust Particles: A Test for Stratospheric Contamination. First Report of Taenite in an Asteroidal Interplanetary Dust Particle: Flash-heating Simulates Nebular Dust Evolution. FTIR Analyses of IDPs: Comparison with the InfraRed Spectra of the Interstellar Medium. Mineralogical Study of Hydrated IDPs: X-Ray Diffraction and Transmission Electron Microscopy. Focused Ion Beam Recovery and Analysis of Interplanetary Dust Particles (IDPs) and Stardust Analogues. Technique for Concentration of Carbonaceous Material from Aerogel Collectors Using HF-Vapor Etching. Synchrotron X-Ray Analysis of Captured Particle Residue in Aerogel. In-Situ Analyses of Earth Orbital Grains Trapped in Aerogel, Using Synchrotron X-Ray Microfluorescence Techniques. Igneous Rims on Micrometeorites and the Sizes of Chondrules in Main Belt Asteroids.

Source record↗

Multilayer diffraction at 104 keV

We have measured the diffraction peak of a W:Si synthetic multilayer reflector at 104 keV using the High Energy Bonse-Hart Camera at the X-17B hard X-ray wiggler beam line of the National Synchrotron Light Source at Brookhaven National Laboratory. The characteristics of the diffraction peak are described and compared to theory.

Krieger, Allen S.↗

High-pressure phase diagram and equation of state of solid helium from single-crystal X-ray diffraction to 23.3 GPa

Single-crystal X-ray diffraction measurements have been performed on solid He-4 from 15.6 to 23.3 GPa at 300 K with synchrotron radiation. The diffraction patterns demonstrate that the structure of the solid is hexagonal close packed over this pressure-temperature range, contrary to both the interpretation of high-pressure optical studies and to theoretical predictions. The solid is more compressible than is indicated by equations of state calculated with recently determined helium pair potentials. The results suggest that a significant revision of current views of the phase diagram and energetics of dense solid helium is in order.

Mao, H. K.↗

Polarized Resonant Soft X-ray Scattering (P-RSoXS) as a New Technique for Characterizing Amorphous Astromaterials

In the coming years, samples will be returned from several asteroids, the lunar surface, and the first material returned directly from the Martian surface. Previous in-situ and remote studies indicate these samples will contain abundant amorphous or weakly crystalline materials. However, detailed characterization and quantification of these amorphous materials remains challenging. Conventional techniques, including electron microscopy and X-ray diffraction, provide important information on material structure, but are generally limited to crystalline materials. Polarized resonant soft X-ray scattering (P-RSoXS) is a synchrotron-based X-ray scattering technique that has been used to characterize and quantify weakly crystalline systems, including soft materials. This research aims to translate this technique to geologic and extraterrestrial materials, building off the knowledge of using P-RSoXS to interrogate soft materials. P-RSoXS is well-suited to interrogate geologic materials, which are often multiphase, heterogeneous systems with crystalline and amorphous components, and domain sizes on the order of tens of nanometers. It is anticipated that future work will help reveal new chemical and structural information in geologic materials. Maturation of this preliminary work to develop P-RSoXS to characterize astromaterial-relevant samples will provide new understanding of the secondary processes responsible for the development of amorphous astromaterials and further elucidate our knowledge of the geologic history and past alteration processes.

Joshua H Litofsky↗

Beamline Electrostatic Levitator (BESL) for in-situ High Energy K-Ray Diffraction Studies of Levitated Solids and Liquids at High Temperature

Determinations of the phase formation sequence, the crystal structures and the thermodynamic properties of materials at high temperatures are difficult because of contamination from the sample container and environment. Containerless processing techniques, such as electrostatic (ESL), electromagnetic (EML), aerodynamic, and acoustic levitation, are most suitable these studies. An adaptation of ESL for in-situ structural studies of a wide range of materials, including metals, semiconductors, insulators using high energy (125 keV) synchrotron x-rays is described here. This beamline ESL (BESL) allows the in-situ determination of the atomic structures of equilibrium solid and liquid phases, including undercooled liquids, as well as real-time studies of solid-solid and liquid-solid phase transformations. The use of image plate (MAR345) or GE-Angio detectors enables fast (30 ms - 1s) acquisition of complete diffraction patterns over a wide q-range (4 - 140/mm). The wide temperature range (300 - 2500 K), containerless processing under high vacuum (10(exp -7) - 10(exp -8) torr), and fast data acquisition, make BESL particularly suitable for phase diagram studies of high temperature materials. An additional, critically important, feature of BESL is the ability to also make simultaneous measurement of a host of thermo-physical properties, including the specific heat, enthalpy of transformation, solidus and liquidus temperatures, density, viscosity, and surface tension; all on the same sample and simultaneous with the structural measurements.

Gangopadhyay, A. K.↗

Perfectly Cold Crystals: What Happens When They Are X-rayed?

For many macromolecular crystals the cryo-preservation of these crystals during X-ray data collection is of crucial importance, particularly at synchrotron facilities where the crystals rapidly receive a high dose of radiation. A practical variable to ensure adequate preservation is the variation of the cryo-protectant present when the crystal is preserved. Our initial approach to study X-ray diffraction data quality as a function of cryo-protectant present when preserving a xylose isomerase crystal shows that the data quality can be tremendously improved by recipe adjustment. Guided by crystal mosaicity estimates, we optimized crystal growth conditions to obtain cryo-preserved xylose isomerase crystals that withstand a very high dose of X-rays, with only the smallest amount of radiation damage at ultra-high resolution (1.2Angstroms). The rate at which damage occurs allowed us to collect a series of complete data sets, which show how the data degradation proceeds over time. We are here presenting data for the xylose isomerase crystallization recipe improvement and our interpretation of the crystal degradation process during X-ray data collection.

vanderWoerd, Mark↗

A Test of Macromolecular Crystallization in Microgravity: Large, Well-Ordered Insulin Crystals

Crystals of insulin grown in microgravity on space shuttle mission STS-95 were extremely well-ordered and unusually large (many > 2 mm). The physical characteristics of six microgravity and six earth-grown crystals were examined by X-ray analysis employing superfine f slicing and unfocused synchrotron radiation. This experimental setup allowed hundreds of reflections to be precisely examined for each crystal in a short period of time. The microgravity crystals were on average 34 times larger, had 7 times lower mosaicity, had 54 times higher reflection peak heights and diffracted to significantly higher resolution than their earth grown counterparts. A single mosaic domain model could account for reflections in microgravity crystals whereas reflections from earth crystals required a model with multiple mosaic domains. This statistically significant and unbiased characterization indicates that the microgravity environment was useful for the improvement of crystal growth and resultant diffraction quality in insulin crystals and may be similarly useful for macromolecular crystals in general.

Borgstahl, Gloria E. O.↗

High Pressure X-Ray Diffraction Studies of Nanocrystalline Materials

Experimental evidence obtained for a variety of nanocrystalline materials suggest that the crystallographic structure of a very small size particle deviates from that in the bulk crystals. In this paper we show the effect of the surface of nanocrystals on their structure by the analysis of generation and distribution of macro- and micro-strains at high pressures and their dependence on the grain size in nanocrystalline powders of Sic. We studied the structure of Sic nanocrystals by in-situ high-pressure powder diffraction technique using synchrotron and neutron sources and hydrostatic or isostatic pressure conditions. The diffraction measurements were done in HASYLAB at DESY using a Diamond Anvil Cell (DAC) in the energy dispersive geometry in the diffraction vector range up to 3.5 - 4/A and under pressures up to 50 GPa at room temperature. In-situ high pressure neutron diffraction measurements were done at LANSCE in Los Alamos National Laboratory using the HIPD and HIPPO diffractometers with the Paris-Edinburgh and TAP-98 cells, respectively, in the diffraction vector range up to 26 Examination of the response of the material to external stresses requires nonstandard methodology of the materials characterization and description. Although every diffraction pattern contains a complete information on macro- and micro-strains, a high pressure experiment can reveal only those factors which contribute to the characteristic diffraction patterns of the crystalline phases present in the sample. The elastic properties of powders with the grain size from several nm to micrometers were examined using three methodologies: (l), the analysis of positions and widths of individual Bragg reflections (used for calculating macro- and micro-strains generated during densification) [I], (2). the analysis of the dependence of the experimental apparent lattice parameter, alp, on the diffraction vector Q [2], and (3), the atomic Pair Distribution Function (PDF) technique [3]. The results of our studies show, that Sic nanocrystals have the features of two phases, each with its distinct elastic properties. and under pressures up to 8 GPa.

Palosz, B.↗

The High Mosaicity Illusion: Revealing the True Physical Characteristics of Macromolecular Crystals

An experimental system and software have been developed for simultaneously measuring the diffraction resolution and mosaic spread of macromolecular crystals. Hundreds of reflection profiles over a wide resolution range were rapidly measured by using a charge coupled device (CCD) area detector in combination with superfine phi slicing data collection. The contributions of the X-ray beam to the reflection widths were minimized by using a highly-parallel, highly-monochromatic synchrotron source. These contributions and Lorentz effects were evaluated and deconvoluted from the recorded data. Data collection and processing is described. From one degree of superfine phi slice data collected on a crystal of manganese superoxide dismutase the mosaicity of 261 reflections were measured. The average mosaicity was 0.0101 degrees (0.0035) at the full-width-at-half-maximum (FWHM) and ranged from 0.0011 degrees to 0.0188 degrees. Each reflection profile was individually fit with two gaussian profiles with the first gaussian contributing 55% and the second contributing 35% of the reflection. On average, the mosaicity of the first gaussian was 0.0054 degrees (0.0015) and the second was 0.0061 degrees (0.0023). The mosaicity of the crystal was anisotropic with fh, f k, and fl values of 0.0068 degrees, 0.0140 degrees and 0.0046 degrees, respectively at the FWHM. The anisotropic mosaicity analysis indicates that the crystal is the most perfect in the I direction which corresponds to the favored growth direction of the crystal.

Bellamy, Henry↗

Nuclear techniques in studies of condensed matter

Nuclear techniques have played an important role in the studies of materials over the past several decades. For example, X-ray diffraction, neutron diffraction, neutron activation, and particle- or photon-induced X-ray emission techniques have been used extensively for the elucidation of structural and compositional details of materials. Several new techniques have been developed recently. Four such techniques are briefly reviewed which have great potential in the study and development of new materials. Of these four, Mossbauer spectroscopy, muon spin rotation, and positron annihilation spectroscopy techniques exploit their great sensitivity to the local atomic environments in the test materials. Interest in synchrotron radiation, on the other hand, stems from its special properties, such as high intensity, high degree of polarization, and high monochromaticity. It is hoped that this brief review will stimulate interest in the exploitation of these newer techniques for the development of improved materials.

Singh, Jag J.↗

Growth of ZnTe by Physical Vapor Transport and Traveling Heater Method

ZnTe crystals were grown by horizontal physical vapor transport (PVT) and a Te-solution vertical traveling heater method (THM). The grown crystals were examined by X-ray Laue diffraction technique and Hall measurements to determine the growth orientation and the electrical properties of the crystals. They were also characterized by low temperature infrared (IR) absorption measurements. Several sets of distinct peaks were observed in the IR absorption spectra for the THM samples and were identified as resulting from CU(2+) impurities. Similar measurements on vapor grown ZnTe showed featureless absorption spectra. Chemical analyses were carried out to measure the impurity content in various ZnTe samples and synchrotron radiation topography was used to Study crystalline microstructure of the (111) ZnTe single crystals grown by PVT.

Su, Ching-Hua↗

The Question of Impurities in Macromolecule Crystal Quality Improvement in Microgravity

While macromolecule impurities may affect crystal size and morphology the over-riding question is how do macromolecule impurities effect crystal X-ray quality and diffraction resolution. In the case of chicken egg white lysozyme previous researchers have reported that crystals grown in the presence of ovalbumin, ovotransferrin, and turkey egg white lysozyme show no difference in diffraction resolution compared to those grown in pure solutions. One impurity however, a naturally occurring lysozyme dimer, does negatively impact the X-ray crystal properties. For this impurity it has been reported that crystal quality improvement in microgravity may be due to improved impurity partitioning during crystallization. In this study we have examined the incorporation of the dimer into lysozyme crystals, both on the ground and in microgravity experiments, and have performed detailed X-ray analysis of the crystals using a new technique for finely probing the mosaicity of the crystal at the Stanford Synchrotron Radiation Laboratory. Dimer partitioning was not significantly different in microgravity compared to the ground based experiments, although it is significantly better than that previously reported in microgravity. Mosaicity analysis of pure crystals, 1422 indexed reflections (microgravity) and 752 indexed reflections (ground), gave average results of 0.0066 and 0.0092 degrees (FWHM) respectively. The microgravity crystals also provided an increased signal to noise. Dimer incorporation increased the average mosaicity in microgravity but not on the ground. However, dimer incorporation did greatly reduce the resolution limit in both ground and microgravity grown crystals. The data is being treated anisotropically to explore these effects. These results indicate that impurity effects in microgravity are complex and that the conditions or techniques employed may greatly affect the role of impurities.

Judge, Russell A.↗

Reciprocal Space Mapping of Macromolecular Crystals in the Laboratory

The technique of reciprocal space mapping applied to the physical measurement of macromolecular crystals will be described. This technique uses a triple axis diffractometer setup whereby the monochromator is the first crystal, the sample is the second and the third crystal (of the same material as the monochromator) analyzes the diffracted beam. The geometry is such that it is possible to separate mosaic volume effects from lattice strain effects. The deconvolution of the instrument parameters will also be addressed. Results from measurements at Brookhaven National Synchrotron Radiation Source carried out on microgravity and ground-grown crystals will be presented. The required beam characteristics for reciprocal space mapping are also ideal for topographic studies and the first topographs ever recorded from microgravity protein crystal samples will be shown. We are now working on a system which will enable reciprocal space mapping, mosaicity and topography studies to be carried out in the home laboratory. This system uses a rotating anode X-ray source to provide an intense beam then a Bartels double crystal, four reflection monochromator to provide the spectral and geometric beam conditioning necessary such that the instrument characteristics do not mask the measurement. This is coupled to a high precision diffractometer and sensitive detector. Commissioning data and first results from the system will be presented.

Snell, Edward H.↗

Comprehensive Study of Hydrated IDPs: X-Ray Diffraction, IR Spectroscopy and Electron Microscopic Analysis

Chondritic hydrated interplanetary dust particles (IDPs) comprise up to 50% of all IDPs collected in the stratosphere(1). Although much is known about the mineralogy, chemistry and carbon abundance of hydrated IDPs (2-4) controversies still exist regarding their formation, history, and relationship to other primitive solar system materials. Hydrated IDPs are generally believed to be derived from asteroidal sources that have undergone some degree of aqueous alteration. However, the high C contents of hydrated IDPs (by 2 to 6X CI levels (3,4) indicate that they are probably not derived from the same parent bodies sampled by the known chondritic meteorites. We report the comprehensive study of individual hydrated IDPs. The strong depletion in Ca (I) has been used as a diagnostic feature of hydrated IDPs. The particles are embedded in elemental sulfur or low viscosity epoxy and ultramicrotomed thin sections are observed using a transmission electron microscope (TEM) equipped with an energy-dispersive X-ray detector (EDX) followed by other measurements including: 1) FTIR microspectroscopy to understand the significant constraints on the organic functionality and the nature of the C-bearing phases and 2) powder X-ray difiaction using a synchrotron X-ray source to understand the bulk mineralogy of the particles.

Nakamura, K.↗