Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An automated liquid jet for fluorescence dosimetry and microsecond radiolytic labeling of proteins

X-ray radiolytic labeling uses broadband X-rays for in situ hydroxyl radical labeling to map protein interactions and conformation. High flux density beams are essential to overcome radical scavengers. However, conventional sample delivery environments, such as capillary flow, limit the use of a fully unattenuated focused broadband beam. An alternative is to use a liquid jet, and we have previously demonstrated that use of this form of sample delivery can increase labeling by tenfold at an unfocused X-ray source. Here we report the first use of a liquid jet for automated inline quantitative fluorescence dosage characterization and sample exposure at a high flux density microfocused synchrotron beamline. Our approach enables exposure times in single-digit microseconds while retaining a high level of side-chain labeling. This development significantly boosts the method’s overall effectiveness and efficiency, generates high-quality data, and opens up the arena for high throughput and ultrafast time-resolved in situ hydroxyl radical labeling.

59 BASIC BIOLOGICAL SCIENCES↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

SonicPy: a suite of programs for ultrasound pulse-echo data acquisition and analysis

Sound speed and elastic constants measurements in solids and liquids are commonly performed using the ultrasound pulse-echo technique. Recent advances have expanded the use of this technique at numerous high pressure synchrotron beamlines and offline laboratories. However, the increased experimental throughput has revealed many limitations in existing software for handling the rapid measurement and the subsequent data-reduction. Here, we report the development of a collection of computer programs for sound speed measurements using the ultrasound pulse-echo technique, compatible with stepped multi-frequency, as well as broadband-pulse, couplant-corrected methods. The programs provide a highly interactive graphical interface, enable efficient measurement, exploration and near real-time analysis of the ultrasound data, and contain features useful for working with samples under high pressure and/or high temperature. The included analysis programs can alleviate the time required for data reduction from hours to less than a minute, allowing users to make timely and informed decisions regarding the appropriate experimental parameters.

97 MATHEMATICS AND COMPUTING↗

K-means-driven Gaussian Process data collection for angle-resolved photoemission spectroscopy

Abstract We propose the combination of k-means clustering with Gaussian Process (GP) regression in the analysis and exploration of 4D angle-resolved photoemission spectroscopy (ARPES) data. Using cluster labels as the driving metric on which the GP is trained, this method allows us to reconstruct the experimental phase diagram from as low as 12% of the original dataset size. In addition to the phase diagram, the GP is able to reconstruct spectra in energy-momentum space from this minimal set of data points. These findings suggest that this methodology can be used to improve the efficiency of ARPES data collection strategies for unknown samples. The practical feasibility of implementing this technology at a synchrotron beamline and the overall efficiency implications of this method are discussed with a view on enabling the collection of more samples or rapid identification of regions of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XtalCAMP: a comprehensive program for the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data

XtalCAMP is a software package based on the MATLAB platform, which is suitable for, but not limited to, the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data. The main objective of the software is to provide complementary functionalities to the Laue indexing software packages used at several synchrotron beamlines. Here, the graphical user interfaces allow the easy analysis of characteristic microstructure features, including real-time intensity mapping for a quick examination of phase, grain and defect distribution, 2D color-coded mapping of microstructural properties from the output of other Laue indexing software, crystal orientation visualization, grain boundary characterization based on orientation/misorientation calculation, principal strain/stress analysis, and strain ellipsoid representation, as well as a series of additional toolkits. As an example, XtalCAMP is applied to the microstructural investigation of a solution-heat-treated Ni-based superalloy manufactured using a laser 3D-printing technique, and a deformed natural quartzite from Val Bregaglia in the Central Alps.

36 MATERIALS SCIENCE↗

Grazing-incidence X-ray diffraction tomography for characterizing organic thin films

Characterization of thin films is of paramount importance for evaluating material processing outcomes/efficiency as well as establishing structure–property/performance relationships. This article introduces grazing-incidence diffraction tomography (GID tomography), a technique that combines grazing-incidence X-ray scattering and computed tomography to quantitatively determine the dimension and orientation of crystalline domains in thin films without restrictions on the beam coherence, substrate type or film thickness. This computational method extends the capability of synchrotron beamlines by utilizing standard X-ray scattering experiment setups.

36 MATERIALS SCIENCE↗

Bragg Spot Finder (BSF): a new machine-learning-aided approach to deal with spot finding for rapidly filtering diffraction pattern images

Macromolecular crystallography contributes significantly to understanding diseases and, more importantly, how to treat them by providing atomic resolution 3D structures of proteins. This is achieved by collecting X-ray diffraction images of protein crystals from important biological pathways. Spotfinders are used to detect the presence of crystals with usable data, and the spots from such crystals are the primary data used to solve the relevant structures. Having fast and accurate spot finding is essential, but recent advances in synchrotron beamlines used to generate X-ray diffraction images have brought us to the limits of what the best existing spotfinders can do. This bottleneck must be removed so spotfinder software can keep pace with the X-ray beamline hardware improvements and be able to see the weak or diffuse spots required to solve the most challenging problems encountered when working with diffraction images. In this paper, we first present Bragg Spot Detection (BSD), a large benchmark Bragg spot image dataset that contains 304 images with more than 66 000 spots. We then discuss the open source extensible U-Net-based spotfinder Bragg Spot Finder (BSF), with image pre-processing, a U-Net segmentation backbone, and post-processing that includes artifact removal and watershed segmentation. Finally, we perform experiments on the BSD benchmark and obtain results that are (in terms of accuracy) comparable to or better than those obtained with two popular spotfinder software packages ( Dozor and DIALS ), demonstrating that this is an appropriate framework to support future extensions and improvements.

36 MATERIALS SCIENCE↗

Tools for supporting solution scattering during the COVID-19 pandemic

During the COVID-19 pandemic, synchrotron beamlines were forced to limit user access. Performing routine measurements became a challenge. At the Life Science X-ray Scattering (LiX) beamline, new instrumentation and mail-in protocols have been developed to remove the access barrier to solution scattering measurements. Our efforts took advantage of existing instrumentation and coincided with the larger effort at NSLS-II to support remote measurements. Given the limited staff–user interaction for mail-in measurements, additional software tools have been developed to ensure data quality, to automate the adjustments in data processing, as users would otherwise rely on the experience of the beamline staff, and produce a summary of the initial assessments of the data. This report describes the details of these developments.

99 GENERAL AND MISCELLANEOUS↗

TomocuPy – efficient GPU-based tomographic reconstruction with asynchronous data processing

Fast 3D data analysis and steering of a tomographic experiment by changing environmental conditions or acquisition parameters require fast, close to real-time, 3D reconstruction of large data volumes. Here a performance-optimized TomocuPy package is presented as a GPU alternative to the commonly used central processing unit (CPU) based TomoPy package for tomographic reconstruction. TomocuPy utilizes modern hardware capabilities to organize a 3D asynchronous reconstruction involving parallel read/write operations with storage drives, CPU–GPU data transfers, and GPU computations. In the asynchronous reconstruction, all the operations are timely overlapped to almost fully hide all data management time. Since most cameras work with less than 16-bit digital output, the memory usage and processing speed are furthermore optimized by using 16-bit floating-point arithmetic. As a result, 3D reconstruction with TomocuPy became 20–30 times faster than its multi-threaded CPU equivalent. Full reconstruction (including read/write operations and methods initialization) of a 2048 3 tomographic volume takes less than 7 s on a single Nvidia Tesla A100 and PCIe 4.0 NVMe SSD, and scales almost linearly increasing the data size. To simplify operation at synchrotron beamlines, TomocuPy provides an easy-to-use command-line interface. Efficacy of the package was demonstrated during a tomographic experiment on gas-hydrate formation in porous samples, where a steering option was implemented as a lens-changing mechanism for zooming to regions of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WFSUITE: A PYTHON SOFTWARE SUITE FOR X-RAY WAVEFRONT SENDING AND AT-WAVELENGTH METROLOGY

SF-26-025 WFSuite is a graphical and command-line toolkit for coded-mask-based X-ray wavefront sensing and phase reconstruction at synchrotron beamlines. It integrates analysis tools for both relative and absolute speckle-based measurements. In the relative metrology module, WFSuite implements Wavelet-transform-based X-ray Speckle Tracking (WXST) and Wavelet-transform-based Speckle Vector Tracking (WSVT) methods to retrieve differential phase and wavefront distortions by comparing speckle patterns recorded with and without the test sample. In the absolute phase module, WFSuite uses coded-mask speckle patterns and replaces the measured reference with a numerically simulated one, enablingsingle-shot wavefront reconstruction using either WXST or a neural-network-based method (SPINNet).

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Tandem neural network-based controller for x-ray bimorph mirrors

Nanometer-scale shape control of x-ray mirrors is crucial for coherent x-ray beam experiments at low-emittance synchrotron beamline instruments. Piezoelectric bimorph mirrors offer adaptive control but are hindered by nonlinearities such as cross talk, creep, and hysteresis. To overcome these limitations, we present a novel feedback-free control solution, inspired by the proportional–integral–derivative (PID) scheme, driven by tandem neural networks (TNNs). Using task-specific datasets, the TNN-based system predicts actuator voltages with greater speed, accuracy, and stability than a single NN-based model. This approach is ideal for real-time applications, such as adapting beam focus to dynamic sample sizes while maintaining precise wavefront quality. Our findings highlight the potential of artificial intelligence in rapidly optimizing adaptive optics and managing nonlinear control systems.

Zhang, Runyu↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗

Wave-Optics Simulation Framework of Fourier Transform Holography with XMCD

We present a wave-optics simulation framework, implemented within the SRW, for modeling FTH with XMCD contrast. The framework propagates coherent, circularly polarized X-ray wavefronts from an undulator source through the sample and optics to the detector, reconstructing real-space images from the resulting holograms. Three principal extensions are introduced: (i) incorporation of polarization-dependent refractive indices in the sample plane, enabling direct simulation of XMCD contrast, (ii) a memory-efficient wavefront-splitting propagation scheme that treats individual apertures independently and coherently combines their fields at detector, and (iii) an integrated reconstruction module that delivers holographic images within the same framework. Together, these advances establish a versatile tool for quantitative exploration of coherence, aperture geometry, and detector sampling, and for the design and interpretation of XMCD-FTH experiments at synchrotron beamlines.

43 PARTICLE ACCELERATORS↗

Ground Calibration of the Astro-H (Hitomi) Soft X-Ray Spectrometer

The Astro-H (Hitomi) Soft X-ray Spectrometer (SXS) was a pioneering imaging x-ray spectrometer with 5 eV energy resolution at 6 keV. The instrument used a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution non-dispersive spectroscopy in the soft x-ray waveband (0.3-12 keV). We present the suite of ground calibration measurements acquired from 2012-2015, including characterization of the detector system, anti-coincidence detector, optical blocking filters, and filter-wheel filters. The calibration of the 36-pixel silicon thermistor microcalorimeter array includes parameterizations of the energy gain scale and line spread function for each event grade over a range of instrument operating conditions, as well as quantum efficiency measurements. The x-ray transmission of the set of five Al/polyimide thin-film optical blocking filters mounted inside the SXS dewar has been modeled based on measurements at synchrotron beamlines, including with high spectral resolution at the C, N, O, and Al K-edges. In addition, we present the x-ray transmission of the dewar gate valve and of the filters mounted on the SXS filter wheel (external to the dewar), including beryllium, polyimide, and neutral density filters.

detectors↗

Reflectivity Around the Gold L-Edges of X-Ray Reflector of the Soft X-Ray Telescope Onboard ASTRO-H

We report the atomic scattering factor in the 11.215.4 keV for the ASTRO-H Soft X-ray Telescope (SXT) obtained in the ground based measurements. The large effective area of the SXT covers above 10 keV. In fact, the flight data show the spectra of the celestical objects in the hard X-ray band. In order to model the area, the reflectivity measurements in the 11.2-15.4 keV band with the energy pitch of 0.4-0.7 eV were made in the synchrotron beamline Spring-8 BL01B1. We obtained atomic scattering factors f1 and f2 by the curve fitting to the reflectivities of our witness sample. The edges associated with the golds L-I, II, and III transitions are identified, of which the depths are found to be roughly 60 percent shallower than those expected from the Henke's atomic scattering factor.

X-rays↗