Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design, characterization, and performance of a hard x-ray transmission microscope at the National Synchrotron Light Source II 18-ID beamline

A transmission X-ray microscope (TXM) has been designed and commissioned at the 18-ID Fullfield X-ray Imaging (FXI) beamline at the National Synchrotron Light Source-II (NSLS-II). This instrument operates in the 5-11 keV range, and, with the current set of optics, is capable of 30 nm spatial resolution imaging, with a field of view (FOV) of about 40 microns. For absorption contrast, the minimum exposure time for a single projection image is about 20 ms and an entire 3D tomography data set can be acquired in under one minute. The system enables tomographic reconstructions with sub-50 nm spatial resolution without the use of markers on the sample or corrections for rotation run-outs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design and performance of BOREAS, the beamline for resonant X-ray absorption and scattering experiments at the ALBA synchrotron light source

The optical design of the BOREAS beamline operating at the ALBA synchrotron radiation facility is described. BOREAS is dedicated to resonant X-ray absorption and scattering experiments using soft X-rays, in an unusually extended photon energy range from 80 to above 4000 eV, and with full polarization control. Its optical scheme includes a fixed-included-angle, variable-line-spacing grating monochromator and a pair of refocusing mirrors, equipped with benders, in a Kirkpatrick–Baez arrangement. It is equipped with two end-stations, one for X-ray magnetic circular dichroism and the other for resonant magnetic scattering. In conclusion, the commissioning results show that the expected beamline performance is achieved both in terms of energy resolution and of photon flux at the sample position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Stitching interferometry for synchrotron mirror metrology at National Synchrotron Light Source II (NSLS-II)

With the fast development of diffraction-limited storage rings and free electron lasers, the requirement for ultimate quality X-ray mirror is getting higher and the mirror surface needs to approach the sub-nm root mean square height specifications. Here, these ultimate specifications challenge the X-ray mirror metrology community. In this work, we present our developed dedicated stitching metrology platform for X-ray mirror metrology. Various stitching methods with different stitching parameters are investigated in our stitching interferometric system. Some experimental results are given to demonstrate its validity and performance. According to the measurement results, the repeatability of measuring a flat mirror in the software stitching mode is at 0.1 nm RMS level. In relative angle determinable stitching mode when measuring a curved mirror with its radius of curvature varying from 50 m to 175 m, the repeatability is around 1 nm RMS.

42 ENGINEERING↗

In situ temperature synthesis and characterization of ferroelectric PZN-4.5PT nanoparticles’ thin films using synchrotron light source

Despite the excellent properties of Pb(Zn 1/3 Nb 2/3 )O 3 -4.5PbTiO 3 (PZN-4.5PT) single crystals, the greatest difficulty for their application on electronic devices is to make them to thin layers related to the difficulty to make them as ceramic materials. In this paper, we use the combined USAXS/SAXS/WAXS instrument at 9ID beamline at APS-ANL for in situ characterization of PZN-4.5PT inorganic perovskite nanoparticles thin films deposited on nanotextured silicon to understand the phase transitions and determine the observed microcrystals' structure. Here, the sample was annealed from ambient to 1000°C. The results revealed structure changes in the nanoparticles' thin films which could be explained by the new phase that can be assigned to the Pb 3 (PO 4 )2-based component. The peak at 31° indicates the presence of the rhombohedral phase perovskites assigned to the nanoparticles. WAXS characterization permitted to identification of many transitions during thermal annealing like dehydration or dihydroxylation of phosphorus gel -OH bonds and internal water.

36 MATERIALS SCIENCE↗

Biomolecular solution X-ray scattering at the National Synchrotron Light Source

In recent years there has been a growing interest in the application of X-ray scattering techniques to biomolecules in solution. At NSLS, a new undulatorbased beamline, X9, has been constructed to address the oversubscribed user demand for X-ray scattering. Beamline X9 has the capability to perform small/wide-angle X-ray scattering (SAXS/WAXS) all in one single instrument. This is accomplished by utilizing a vacuum sample/detector chamber that is an integral part of the SAXS scattering flight path. This vacuum chamber allows a WAXS detector to be positioned at a close distance from the sample, while not interfering with scattered X-rays at small angles from reaching the SAXS detector. A regular training program, the X9 workbench, has also been established to allow users to become familiar with beamline X9 for solution X-ray scattering.

47 OTHER INSTRUMENTATION↗

Performance Improvement of LTS Undulators for Synchrotron Light Sources

The joint expertise of ANL and FNAL has led to the production of $\text{Nb}_{3}\text{Sn}$ undulator magnets in operation in the ANL Advanced Photon Source (APS). These magnets showed performance reproducibility close to the short sample limit, and a design field increase of 20% at 820 A. However, the long training did not allow obtaining the expected 50% increase of the on-axis magnetic field with respect to the ∼1 T produced at 450 A current in the ANL NbTi undulator. To address this, 10-pole long undulator prototypes were fabricated, and CTD-101K was replaced as impregnation material with TELENE, an organic olefin-based thermosetting dicyclopentadiene resin produced by RIMTEC Corporation, Japan. Training and magnet retraining after a thermal cycle were nearly eliminated, with only a couple of quenches needed before reaching short sample limit at over 1,100 A. TELENE will enable operation of $\text{Nb}_{3}\text{Sn}$ undulators much closer to their short sample limit, expanding the energy range and brightness intensity of light sources. TELENE is Co-60 gamma radiation resistant up to 7–8 MGy, and therefore already applicable to impregnate planar, helical and universal devices operating in lower radiation environments than high energy colliders.

43 PARTICLE ACCELERATORS↗

Biomolecular solution X-ray scattering at the National Synchrotron Light Source

In recent years there has been a growing interest in the application of X-ray scattering techniques to biomolecules in solution. At NSLS, a new undulator-based beamline, X9, has been constructed to address the oversubscribed user demand for X-ray scattering. Beamline X9 has the capability to perform small/wide-angle X-ray scattering (SAXS/WAXS) all in one single instrument. This is accomplished by utilizing a vacuum sample/detector chamber that is an integral part of the SAXS scattering flight path. This vacuum chamber allows a WAXS detector to be positioned at a close distance from the sample, while not interfering with scattered X-rays at small angles from reaching the SAXS detector. A regular training program, the X9 workbench, has also been established to allow users to become familiar with beamline X9 for solution X-ray scattering.

43 PARTICLE ACCELERATORS↗