Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Microsecond-latency feedback at a particle accelerator by online reinforcement learning on hardware

The commissioning and operation of future large-scale scientific experiments will challenge current tuning and control methods. Reinforcement learning (RL) algorithms are a promising solution due to their ability to dynamically adapt to changing environments and consider delayed consequences. In many real-world applications, RL policies must produce actions in real time, often within microseconds to milliseconds, imposing significant constraints on system latency and computational overhead that conventional machine learning libraries are not designed to handle. To control phenomena in real time at these timescales, RL needs to be deployed on-the-edge, namely on dedicated hardware located near the system it controls, without relying on a host CPU or cloud-based inference. In this work we present the design and deployment of an experience accumulator system in a particle accelerator. In this system, deep-RL algorithms run using hardware acceleration and act within a few microseconds, enabling the use of RL for control of phenomena like beam instabilities. The training uses the collected data offline to reduce the number of operations carried out on the acceleration hardware. The proposed architecture was tested in real experimental conditions at the Karlsruhe research accelerator, a synchrotron light source, where the system was used to control artificially induced horizontal betatron oscillations in real-time, with a control loop period of just 2.7 μs. The results showed a performance comparable to the commercial feedback system available at the accelerator, demonstrating the viability and potential of this approach. Due to the self-learning and reconfiguration capability of this implementation, a seamless application to other control problems is possible. Applications range from particle accelerators to large-scale research and industrial facilities.

FPGA↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Facile Integration of Robots into Experimental Orchestration at Scientific User Facilities

Integration of robots into scientific user facilities, such as the National Synchrotron Light Source II, improves their efficiency and capacity. Many such facilities use the opensource Bluesky project for experimental control and orchestration. However, there remains an open challenge in deploying robotic solutions at these facilities that are reconfigurable, extensible, and compatible with pre-existing software infrastructure. Herein, we introduce a framework that uses the Robotic Operating System 2 (ROS2) and Bluesky to provide extensible robotic applications, while working under the operational constraints of a large-scale user facility. We demonstrated this framework by integrating a robotic arm to pick and place a sample holder at a beamline, recording a 90% repeatability rate. This provides the groundwork for further new robotics applications at large-scale scientific user facilities that depend on Bluesky.

36 MATERIALS SCIENCE↗

Isotropic negative thermal expansion in ZrW 2 O 8 and HfW 2 O 8 from 1100 to 1275°C

Abstract ZrW 2 O 8 (ZrO 2 •2WO 3 ) and HfW 2 O 8 (HfO 2 •2WO 3 ) have been the focus of thermal expansion studies due to their isotropic negative thermal expansion (NTE) measured previously at temperatures below 775°C. This work presents measurements of these materials at their thermodynamically stable temperature ranges of 1105 and 1257°C for ZrW 2 O 8 and 1105–1276°C for HfW 2 O 8 , where they were characterized with in situ, powder X‐ray diffraction. The linear coefficients of thermal expansion were measured to be −5.52 × 10 −6 and −4.87 × 10 −6 °C −1 for ZrW 2 O 8 and HfW 2 O 8 , respectively. The mechanism leading to this NTE is discussed. Powder samples were synthesized by a solution‐based process called the organic–inorganic steric entrapment method. In situ characterization in air was carried out at the National Synchrotron Light Source II using a hexapole lamp, optical furnace and the Advanced Photon Source using a quadrupole lamp, optical furnace to achieve elevated temperatures.

Materials Science↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B×B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincar´e map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. These action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 µrad. Utilizing the BPMs’ B×B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

43 PARTICLE ACCELERATORS↗

Sextupole reduction via chaos suppression at NSLS-II

We revisit the nonlinear lattice design approach for the National Synchrotron Light Source II (NSLS-II) storage ring. By suppressing chaos, we identify alternative sextupole configurations to the original design, which relied on the conventional approach of simultaneously minimizing Resonance Driving Terms (RDTs) and Amplitude-Dependent Detuning (ADD). These alternatives achieve comparable performance while requiring fewer sextupoles. A detailed comparison of two representative solutions is presented and supported by experimental validation. Our results indicate that dynamic aperture correlates more strongly with global chaos than with individual RDTs, and that the importance of minimizing ADD may have been overstated in earlier design approach.

43 PARTICLE ACCELERATORS↗

GPU Acceleration in SRW: Design and Considerations

Synchrotron Radiation Workshop (SRW) is a powerful tool for simulation synchrotron radiation emission and propagation through beamline elements, enabling advanced beamline design and experimental optimization. Recently, GPU acceleration has been developed for SRW to support highly detailed end-to-end simulations of experiments at synchrotron light sources. This work documents the design and implementation of this GPU acceleration support, addressing the complexities of adapting CPU-based components to heterogeneous computing architectures.

43 PARTICLE ACCELERATORS↗

Pulsed Magnet Power Systems at NSLS-II

The National Synchrotron Light Source - II (NSLS-II) is a 3 GeV X-ray user facility with 29 beamlines. The NSLS-II pulsed power system consists of an event generator for timely injection and extraction of beam in the transport line from linac to booster at 170 MeV, and from booster to storage ring at 3 GeV. We will discuss current pulsed power systems and the future upgrades/improvements on those systems.

43 PARTICLE ACCELERATORS↗

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS↗

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE↗

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

Reaction Mechanism of Electrodeposited ε-MnO 2 : A Proton-Centered Pathway in Aqueous Zn-Ion Systems

Aqueous Zn/MnO 2 batteries have garnered significant interests owing to their abundance, high theoretical specific capacity, safety, and low cost. However, large-scale application of these systems is limited by the incomplete understanding of the MnO 2 reaction chemistry. The different crystal lattice structures among MnO 2 polymorphs contribute to the variations in reported reaction mechanisms. Among them, ε-MnO 2 polymorph, the dominant phase in electrolytic manganese dioxide (EMD), is notably observed during the charge cycles of aqueous Zn/MnO 2 batteries. Here, in this work, we investigate the electrochemical behavior of an ε-MnO 2 cathode synthesized via electrodeposition from a ZnSO 4 and MnSO 4 electrolyte, onto a 3-dimensional carbon cloth substrate. Proton intercalation emerges as the dominant charge storage mechanism, critically enabling the reversibility of ε-MnO 2 during cycling, as revealed by operando synchrotron X-ray diffraction and X-ray absorption spectroscopy. Additionally, a proton-coupled dissolution/redeposition pathway operates alongside minor Zn 2+ intercalation, as quantified by Rietveld refinement. Morphological and chemical heterogeneities are studied by transmission X-ray microscopy further validates this reaction mechanism. These mechanistic insights provide the foundation for rationally designing Zn/MnO 2 batteries with optimized proton dynamics and charge transfer, advancing these systems as a viable solution for safe, cost-effective grid-scale energy storage.

36 MATERIALS SCIENCE↗

Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography

We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.

36 MATERIALS SCIENCE↗

Charge correlations and magnetoelastic coupling in intercalated transition metal dichalcogenides

The large van der Waals gap in transition metal dichalcogenides (TMDs) offers an avenue to tune the ground state of 2D materials through the intercalation of magnetic atoms. Here, we investigate the charge correlations in Fe 1/3 ⁢TaS 2 , Co 1/3 ⁢TaS 2 , and Fe 0.35 ⁢NbS 2 by combining angle-resolved photoemission spectroscopy (ARPES), x-ray scattering, magnetometry, and density functional theory (DFT). We find that, while short-range charge fluctuations develop in Ta-based compounds, Fe 0.35 ⁢NbS 2 exhibits long-range charge order which is strongly coupled with magnetic order and tunable by external magnetic field. Our electronic structure analysis reveals that intercalation reconstructs the Fermi surface via charge transfer and band renormalization, yet does not generate the nesting conditions compatible with the observed ordering vectors. Complementary phonon calculations further exclude a conventional electron-phonon origin of charge order. Together, these results establish magnetoelastic coupling as the dominant mechanism behind charge ordering in Fe 0.35 ⁢NbS 2 and highlight the contrasting role of Nb and Ta hosts in stabilizing correlated ground states in intercalated TMDs.

36 MATERIALS SCIENCE↗

Mechanical design of a parallel flexure-based RADSI instrument for curved x-ray mirror metrology

Modern synchrotron x-ray beamlines demand reflective optics with higher surface profile accuracy to achieve diffraction-limited focusing. This necessitates advanced metrology instruments capable of delivering repeatable measurements in the nanometer to sub-nanometer range. Slope ranges exceeding 15 mrad (0.86°) and greater pose significant challenges for mirror metrology using conventional interferometric methods. Here, to address this, we present a new relative angle determinable stitching interferometry instrument featuring a parallel flexure-based mechanical design. This approach enhances vibration and thermal stability while maintaining a compact and lightweight system. Initial measurements of a cylindrical mirror with a 16 m radius of curvature and a slope range of 5 mrad demonstrate nanometer-level repeatability. Comprehensive system characterization suggests the potential for achieving sub-nanometer repeatability with further refinement to the instrument.

36 MATERIALS SCIENCE↗

Understanding Electrochemical Sulfur-Based Phase Evolution via Complementary Insight from Operando Spatially Resolved X-ray Diffraction and X-ray Absorption Spectroscopy

Lithium/sulfur batteries are emerging as promising candidates for use in large-scale energy storage, but practical challenges, including insufficient power density and polysulfide shuttling, remain. Here, this work presents the first use of operando energy dispersive X-ray diffraction (EDXRD) to monitor Li/S electrochemistry within a liquid electrolyte. Complementary operando synchrotron-based EDXRD, X-ray absorption spectroscopy (XAS), X-ray powder diffraction (XPD), and ex situ laboratory Raman analysis provide evidence for α-S 8 conversion upon discharge into Li 2 S x polysulfide phases and conversion into β-S 8 during charge. Understanding the underlying mechanisms of sulfur reduction and oxidation within thick electrodes will enable advances in next-generation Li/S batteries and material design.

36 MATERIALS SCIENCE↗