Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Online thermal profile prediction for large format additive manufacturing: A hybrid CNN-LSTM based approach

Large format additive manufacturing (LFAM) is an advanced 3D printing technique that efficiently fabricates large-scale components through a layer-by-layer extrusion and deposition process. Accurate surface layer temperature monitoring is essential to prevent manufacturing failures and ensure final product quality. Traditional physics-based offline approaches for simulating thermal behavior are often inefficient and complex, posing challenges on real-time, in-situ monitoring. Here, to address this, we propose a data-driven hybrid CNN-LSTM model to predict sequential thermal images of arbitrary length using real-time infrared thermal imaging. In this approach, a Convolutional Neural Networks (CNN) is trained offline to capture spatial features, reduce dimensional complexity, and enhance time efficiency, while a stacked Long Short-Term Memory (LSTM) is applied online to capture temporal information for improved prediction of future thermal behavior in subsequent printing layers. Model performance is evaluated using MSE, SSIM, and PSNR metrics and is benchmarked against stacked LSTM and convolutional LSTM models, demonstrating superior accuracy and applicability. Additionally, to mitigate noise from moving extruders and gantry backgrounds in thermal images, a fine-tuned semantic segmentation model is implemented offline to extract printing geometry, enabling precise temperature tracking along the tool path for further thermal analysis. The frameworks developed in this study significantly advance temperature monitoring, thermal analysis, and in-situ manufacturing control for LFAM, bridging the gap between theoretical modeling and practical application.

Geometry extraction↗

Application of a Physics-Informed Convolutional Neural Network for Monitoring the Temperature Fields in High-Temperature Gas Reactors

Here, this work presents current advances in applying a physics-informed convolutional neural network (CNN) to evaluate temperature distributions in advanced reactors. Our goal is to demonstrate that the CNN can reconstruct temperature fields within the solid region of a prismatic fuel assembly in a high-temperature gas reactor (HTGR) with sensor data available in only a few cooling channels. Before that, we showcase the superior performance of the physics-informed CNN in comparison to a purely data-driven multilayer perceptron (MLP), considering a canonical heated channel setup. This analysis shows the advantages of our approach and justifies its choice. The datasets employed here are obtained upon numerical simulations performed with codes under the Nuclear Energy Advanced Modeling and Simulation program. This work is important, as industry experience indicates that the assembly material in HTGR concepts is prone to large thermal-mechanical loads nearing operational limits. This makes it crucial to characterize peak temperatures and their distributions near hot spots. Modern thermocouples are unreliable in these types of harsh environments because of the high neutron fluxes and elevated temperatures involved. The CNN-based field reconstruction represents an attractive solution, enabling sensor arrays in less aggressive locations and augmenting indirect predictions for less accessible regions. The results show that the CNN reduces prediction errors by orders of magnitude in comparison to the MLP, considering the simple yet well-representative heated channel case. In the case of the HTGR fuel assembly, the CNN can successfully reconstruct temperature fields over various cooling regimes. Furthermore, we also explore the algorithm’s ability to detect abnormalities. Interestingly, the CNN proves it has the capacity to detect blockage in one of the noninstrumented cooling channels.

Machine learning↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TDD LoRa and Delta Encoding in Low-Power Networks of Environmental Sensor Arrays for Temperature and Deformation Monitoring: Supporting Data

This dataset was used to assess the performance of a compression algorithm for Soil Deformation and Temperature Monitoring data. The development of this technology is presented in the article named time division duplex (TDD) "TDD LoRa and Delta Encoding in Low-Power Networks of Environmental Sensor Arrays for Temperature and Deformation Monitoring" and published in Springer's Journal on Signal Processing Systems. [Time Division Duplex (TDD); Long Range (LoRa)]Field experiment data includes: 1) soil temperature measurements, 2) snow temperature data, 3) soil temperature and deformation data. In these files, the first column contains the time (UTC), followed by the sensor's battery voltage and temperature and acceleration values (X, Y, Z) in subsequent columns. The measurements were acquired every 15 minutes. Lists included for probe, datalogger, and packaging components. The two temperature data sets were acquired at a site at the East River Watershed, Colorado, while the temperature/deformation data were collected at the Teller Road (mile 27) site near Nome, Alaska. The package includes 8 comma-separated files (.csv) and one .pdf file.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Design Optimization for Printed Melt Wire Arrays Encapsulation

As part of the Nuclear Energy Enabling Technology (NEET) Advanced Sensor and Instrumentation (ASI) Program, Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced-manufactured sensors for measuring peak irradiation temperature within a nuclear test reactor. Although methods of real-time temperature monitoring, such as thermocouples, may be used, the complexity of feedthroughs and attachments to collect real-time measurements greatly increases the cost of the experiment. Instead, passive monitoring techniques may be used for peak- temperature measurement that exploit the melting point of well-characterized materials (standard melt wires) to infer peak reactor temperatures. However, limited available space for instrumentation during experiments introduces an additional challenge. To accommodate this, INL has expanded its temperature- detection instrumentation capabilities to include advanced manufactured (AM) melt wires for peak irradiation temperature measurements. These melt wires can determine peak temperatures while also accommodate space limitations in irradiation experiments. In an effort to improve performance reliability of AM meltwire capabilities, a process was developed and tested to identify the significance of entrapping a high purity inert atmosphere within the packaging of printed melt wire arrays. The materials used in this study were aluminum, zinc, and tin encapsulated in high purity helium within a stainless steel (SS) 316 container. Tin, with a low melting point of approximately 230°C, Zn with a mid-melting point of approximately 420°C, and Al with a high melting point of approximately 660°C. This report describes the design, fabrication process, furnace testing and X-ray Computed Tomography (XCT) evaluation. Results show a successful outcome in creating an inert gas encapsulation and high-resolution evaluation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging

Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging in real time, thus falling short in dynamic temperature mapping. Here, we report video-rate upconversion temperature sensing in wide field using single-shot photoluminescence lifetime imaging thermometry (SPLIT). Developed from a compressed-sensing ultrahigh-speed imaging paradigm, SPLIT first records wide-field luminescence intensity decay compressively in two views in a single exposure. Then, an algorithm, built upon the plug-and-play alternating direction method of multipliers, is used to reconstruct the video, from which the extracted lifetime distribution is converted to a temperature map. Using the core/shell NaGdF 4 :Er 3+ ,Yb 3+ /NaGdF 4 upconverting nanoparticles as the lifetime-based temperature indicators, we apply SPLIT in longitudinal wide-field temperature monitoring beneath a thin scattering medium. SPLIT also enables video-rate temperature mapping of a moving biological sample at single-cell resolution.

47 OTHER INSTRUMENTATION↗

AOI [1]: Passive Wireless Sensor Systems Fabricated by Direct-Writing for Temperature and Health Monitoring of Energy Systems in Harsh-Environments (Final Report)

Researchers at West Virginia University (WVU) propose to demonstrate a wireless, high-temperature sensor system for monitoring the temperature and health of energy-system components. The active sensor and electronics for wireless communication will be composed entirely of an electroceramic materials (conductive ceramics) which are capable of withstanding the harsh-environments required for fossil energy-based technologies. This work will focus primarily on the fabrication and testing of temperature (thermocouples and thermistors) and health (strain/stress and crack propagation sensors) that function at extreme temperatures (up to 700-1700ºC). The electronics will accompany the high-temperature sensor, which will include a passive wireless communication circuit that allows the transmission of the data based on the LCR resonance principle to a near-by reader antenna. This passive transmission of data will reduce the need for interconnect wires near the active, and possibly rotating, energy-system component. The research will include process development to permit the 2D/3D direct-writing of the entire sensor and communication circuit onto the energy-system component. The direct-writing will be facilitated by using silicon-based polymer-derived precursors to form the high-temperature, stable electroceramic compositions. In addition, methods for direct-writing the circuit onto a fugitive carrier substrate will be completed, which will permit a “peel-and-stick”-like transfer of the sensor circuit to the energy-system component. This feature will allow the economical and precise placement of the sensor circuit onto components of various shapes and locations, without altering the geometry and active features of the manufactured component, or the removal (or decommissioning) of the component for installation. The proposed work will be directed at the following areas: 1) Investigation of phase formation, sintering/grain growth, and electrical properties of polymer-derived electroceramic composites; 2) Definition of processes to direct-write through ink-jet and robo-casting the polymer-derived electroceramic composites onto oxide and polymer surfaces; 3) Development of methods to form monolithic "peel-and-stick" preforms that will efficiently transfer the sensor circuit to ceramic surfaces after thermal treatment; 4) Design of passive wireless LCR circuits and receiver (reader) antennas for communication and testing at high temperatures; 5) Investigation of the passive wireless sensor system developed (and method of transferring sensor system) for temperature and stress/strain measurements on a SOFC repeat unit and a singular gas turbine blade prototype as example applications.

01 COAL, LIGNITE, AND PEAT↗

Optimizing ensemble NV − spin properties of fluorescent diamond microparticles by systematic low pressure high temperature annealing

Low pressure high temperature annealing is a means for driving nitrogen and defect diffusion in diamond to reduce internal lattice damage without the need for technically complicated high-pressure cells. Herein, we perform a systematic time (5, 15, and 30 min) and temperature (1200 °C–1800 °C) study of effects of low-pressure high temperature annealing on photoluminescence, spin concentrations, and spin relaxation properties of NV centers in ca. 3 μm synthetic type 1b diamond particles. Annealing in the temperature range of ca. 1400 °C–1700 °C for even 5 min leads to a higher optically detected magnetic resonance contrast as compared to standard annealing at 900 °C for 2 h. Particles annealed at 1700 °C for 5 min exhibit a contrast close to about 13% as compared to about 9% for those annealed at 900 °C for 2 h. A reduction in the zero-field splitting strain parameter from E ≈ 4.5 MHz to ≈ 2.5 MHz and spectral linewidth from Δν ≈ 7 MHz to ≈ 4 MHz are observed even after 5 min annealing at 1700 °C. Improvements in these spectral parameters resulted in a roughly 2-fold reduction in the noise level of temperature monitoring experiment utilizing an ensemble of NV centers in the particles. Annealing in the temperature range of 1600 °C for 15 or 30 min or 1700 °C for 5 min resulted in NV T 1 relaxation times approaching ca. 5 ms typically observed for bulk diamond. Quantitative electron paramagnetic resonance (EPR) allowed for estimations of thermal activation energies of paramagnetic center annihilation. Monitoring the primary defect concentration (P1 and other defects with half integer spins) and utilizing second order kinetic modeling, an activation energy of 3.63 ± 0.28 eV was estimated. Alternatively, using the NV half field EPR signal and first order kinetic modeling, a similar activation energy 3.89 ± 0.29 eV was estimated.

NV centers↗

Melt pool temperature measurement and monitoring during laser powder bed fusion based additive manufacturing via single-camera two-wavelength imaging pyrometry (STWIP)

Melt pool (MP) temperature is one of the determining factors and a key signature for evaluating the properties of printed components in metal additive manufacturing (AM). The state-of-the-art measurement systems are hindered, primarily by the large-scale data acquisition and processing demands. In this work, we introduce a novel coaxial, high-speed, single-camera two-wavelength imaging pyrometer (STWIP) system as opposed to the typical utilization of multiple cameras for measuring MP temperature profiles in laser powder bed fusion (LPBF) processes. Developed on a commercial LPBF machine (EOS M290), the STWIP system demonstrated its ability to quantitatively monitor the MP temperature and its variation for 50 layers at high framerates (>30,000 fps) for a real-world application (standard fatigue specimens) print. High performance computing is employed to analyze the acquired big data (MP images), for determining each MP's average temperature and 2D temperature profile. The MP temperature evolution in the gage section of a fatigue specimen is also examined at a temporal resolution of 1 ms, by evaluating the MP temperatures in the samples' first, middle, and last layers. This report is the first of its kind on monitoring MP temperature distribution and evolution at such a large, detailed scale for longer durations in practical applications.

42 ENGINEERING↗

Passive Wireless Sensors for Realtime Temperature and Corrosion Monitoring of Coal Boiler Components Under Flexible Operation (Final Technical Report)

Researchers at West Virginia University (WVU) propose to demonstrate inexpensive wireless, high-temperature sensors for real-time monitoring of the temperature and corrosion of metal components, which are commonly used in coal-fired boilers. This study presents the development of cost-effective wireless high-temperature sensors for real-time temperature and corrosion monitoring in coal-fired boilers' metal components. The focus is on fabricating and evaluating chipless radio-frequency identification (RFID) sensors capable of operating between 25-1300 ºC. Efforts were directed towards designing passive RFID sensor and interrogator antenna with a broad frequency range, optimizing a microstrip patch antenna sensor integrated into a "peel-and-stick" format for efficient application to various metal specimens without altering their geometry. Additionally, this research aimed to assess the sensor responses under accelerated high-temperature conditions, correlating corrosion and cracking mechanisms with sensor data. An investigation of through-wall data acquisition techniques was also planned, facilitating unobtrusive monitoring of sensor responses housed within metal enclosures. Ultimately, this work sought to establish a robust passive wireless sensor system for the continuous health monitoring of metal components in operational settings, thereby contributing to enhanced safety and efficiency in coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗