Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Voltage Sensors Monitor Harmful Static

A tiny sensor, small enough to be worn on clothing, now monitors voltage changes near sensitive instruments after being created to alert Agency workers to dangerous static buildup near fuel operations and avionics. San Diego s Quasar Federal Systems received a Small Business Innovation Research (SBIR) contract from Kennedy Space Center to develop its remote voltage sensor (RVS), a dime-sized electrometer designed to measure triboelectric changes in the environment. One of the unique qualities of the RVS is that it can detect static at greater distances than previous devices, measuring voltage changes from a few centimeters to a few meters away, due to its much-improved sensitivity.

Source record↗

Superconducting switch permits measurement of small voltages at cryogenic temperatures

Dual-coil, superconducting, on-off switch measures small, thermoelectrically generated voltages produced by thermocouples in a liquid helium bath. Placed in a shunt configuration between the thermocouple and the measuring device, the measuring device sees the sum of the voltage to be measured and the spurious thermoelectric voltages.

Govednik, R. E.↗

The LeRC rail accelerators: Test designs and diagnostic techniques

The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed.

Zana, L. M.↗

LeRC rail accelerators - Test designs and diagnostic techniques

The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. Previously announced in STAR as N83-35053

Zana, L. M.↗

Cross-contact chain

A system is provided for use with wafers that include multiple integrated circuits that include two conductive layers in contact at multiple interfaces. Contact chains are formed beside the integrated circuits, each contact chain formed of the same two layers as the circuits, in the form of conductive segments alternating between the upper and lower layers and with the ends of the segments connected in series through interfaces. A current source passes a current through the series-connected segments, by way of a pair of current tabs connected to opposite ends of the series of segments. While the current flows, voltage measurements are taken between each of a plurality of pairs of voltage tabs, the two tabs of each pair connected to opposite ends of an interface that lies along the series-connected segments. A plot of interface conductances on normal probability chart enables prediction of the yield of good integrated circuits from the wafer.

Lieneweg, U.↗

Cross-contact chain

A system is provided for use with wafers that include multiple integrated circuits that include two conductive layers in contact at multiple interfaces. Contact chains are formed beside the integrated circuits, each contact chain formed of the same two layers as the circuits, in the form of conductive segments alternating between the upper and lower layers and with the ends of the segments connected in series through interfaces. A current source passes a current through the series-connected segments, by way of a pair of current tabs connected to opposite ends of the series of segments. While the current flows, voltage measurements are taken between each of a plurality of pairs of voltage tabs, the two tabs of each pair connected to opposite ends of an interface that lies along the series-connected segments. A plot of interface conductances on a normal probability chart, enables prediction of the yield of good integrated circuits from the wafer.

Lieneweg, Udo↗

Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring

An ambient temperature oxygen microsensor, based on a Nafion polymer electrolyte, has been developed and was microfabricated using thin-film technologies. A challenge in the operation of Nafion-based sensor systems is that the conductivity of Nafion film depends on the humidity in the film. Nafion film loses conductivity when the moisture content in the film is too low, which can affect sensor operation. The advancement here is the identification of a method to retain the operation of the Nafion films in lower humidity environments. Certain salts can hold water molecules in the Nafion film structure at room temperature. By mixing salts with the Nafion solution, water molecules can be homogeneously distributed in the Nafion film increasing the film s hydration to prevent Nafion film from being dried out in low-humidity environment. The presence of organics provides extra sites in the Nafion film to promote proton (H+) mobility and thus improving Nafion film conductivity and sensor performance. The fabrication of ambient temperature oxygen microsensors includes depositing basic electrodes using noble metals, and metal oxides layer on one of the electrode as a reference electrode. The use of noble metals for electrodes is due to their strong catalytic properties for oxygen reduction. A conducting polymer Nafion, doped with water-retaining components and extra sites facilitating proton movement, was used as the electrolyte material, making the design adequate for low humidity environment applications. The Nafion solution was coated on the electrodes and air-dried. The sensor operates at room temperature in potentiometric mode, which measures voltage differences between working and reference electrodes in different gases. Repeat able responses to 21-percent oxygen in nitrogen were achieved using nitrogen as a baseline gas. Detection of oxygen from 7 to 21 percent has also been demonstrated. The room-temperature oxygen micro sensor developed has extremely low power consumption (no heating for operation, no voltage applied to the sensor, only a voltmeter is needed to measure the output), is small in size, is simple to batch-fabricate, and is high in sensor yield. It is applicable in a wide humidity range, with improved operation in low humidity after the additives were added to the Nafion film. Through further improvement and development, the sensor can be used for aerospace applications such as fuel leak detection, fire detection, and environmental monitoring.

Hunter, Gary W.↗

Silicon device performance measurements to support temperature range enhancement

The results of the NPN bipolar transistor (BJT) (2N6023) breakdown voltage measurements were analyzed. Switching measurements were made on the NPN BJT, the insulated gate bipolar transistor (IGBT) (TA9796) and the N-channel metal oxide semiconductor field effect transistor (MOSFET) (RFH75N05E). Efforts were also made to build a H-bridge inverter. Also discussed are the plans that have been made to do life testing on the devices, to build an inductive switching test circuit and to build a dc/dc switched mode converter.

Johnson, R. Wayne↗

An investigation of impurity redistribution in diffused layer on /n+/-p silicon solar cells parameters

Recent calculations by Wang et al. (1974) have shown that the short-circuit current for silicon solar cells is sensitive to the impurity distribution in the diffused and base region. In the present work, these theoretical results were verified by experimentally investigating the impurity profile and sheet resistance of the diffused layers of (n+)-p silicon solar cells fabricated by normal diffusion processes and at subsequently various drive-in times. Impurity profiles of the n+ diffused layer, measured by differential Hall and resistivity technique, resemble the erfc distribution. The junction depth is larger as drive-in time increases. Measured short-circuit current is in agreement with calculated ones. Open-circuit voltage is independent of drive-in times, and its calculated values are consistent with capacitance-voltage measurements.

Wang, E. Y.↗

Direct-Current Unbalance Detector

Short circuits to ground indicated by voltage changes. Current transducer connected in bridge circuit with floating 30-Vdc power supply measures voltage unbalance between positive and negative powerlines and ground. Detection circuit output swings higher or lower than normal balanced condition voltage to signify unbalance toward positive or negative side respectively. Circuit configuration adaptable to monitor 4- to 20-mA current loops often found in industrial controls.

Wagner, A. P.↗

Programmable Multiple-Ramped-Voltage Power Supply

Ramp waveforms range up to 2,000 V. Laboratory high-voltage power-supply system puts out variety of stable voltages programmed to remain fixed with respect to ground or float with respect to ramp waveform. Measures voltages it produces with high resolution; automatically calibrates, zeroes, and configures itself; and produces variety of input/output signals for use with other instruments. Developed for use with ultraviolet spectrometer. Also applicable to control of electron guns in general and to operation of such diverse equipment used in measuring scattering cross sections of subatomic particles and in industrial electron-beam welders.

Ajello, Joseph M.↗

Minority-carrier mobility anomalies in low-resistivity silicon solar cells

Measurement of the minority-carrier mobility in the base region of a high-voltage metal-insulator-N-P solar cell (Green et al., 1984), as well as in other 0.1-ohm cm cells, provides direct proof that the high voltages measured for that cell are due not only to improved emitter characteristics but to an improved base region as well. The base characteristics are shown to be quite sensitive to the effects of diffusion-induced lattice stress originating in the emitter. The implications of these findings for the fabrication of high-efficiency cells are discussed.

Weizer, V. G.↗

Effects of high doping levels on silicon solar cell performance

Open-circuit voltages measured in silicon solar cells made from 0.01 ohm-cm material are 150 mV lower than voltages calculated from simple diffusion theory and cannot be explained by poor diffusion lengths or surface leakage currents. An analytical study was made to determine whether high doping effects, which increase the intrinsic carrier concentration, could account for the low observed voltages and to determine the limits on voltage and efficiency imposed by high doping effects. The results indicate that the observed variation of voltage with base resistivity is predicted by these effects. A maximum efficiency of 19% (AMO) and a voltage of 0.7 volts were calculated for 0.1 ohm-cm cells assuming an optimum diffused layer impurity profile.

Godlewski, M. P.↗

MPD thruster technology

The topics are presented in viewgraph form and include the following: in house program elements; performance measurements; applied-field magnetoplasmadynamic (MPD) thruster performance scaling; MPD thruster technology; thermal efficiency scaling; anode fall voltage measurements; anode power deposition studies; MPD thruster plasma modeling; MPD thruster lifetime studies; and MPD thruster performance studies.

Myers, Roger M.↗

Flux-flow voltages during guided flux collapse from hollow superconducting cylinders

Voltages across diametrically opposite contact pairs on the outer surface of superconducting Nb tubes are found to depend dramatically upon the spatial configuration of the voltage-measuring leads relative to the positions of the moving magnetic flux lines. Experiments have been conducted to study these voltages for different wall thicknesses and for a variety of arrangements of the leads when flux in the hole and the wall of the Nb tube is made to exit or enter, completely or partially, by applying heat at a narrow strip along its length. Using the critical-state concept, a model for the change of flux and the resulting electric fields in the Nb tube on application of a heat pulse is presented. The resulting time-dependent and time-integrated voltages are calculated in excellent quantitative agreement with the experimental results. These results show that the flux-flow voltages across two contact points on a superconductor arise from the generation of an induced electric field over a chosen path in the superconductor between the contact points and from a change of magnetic flux through the surface bounded by the measuring leads and the chosen path in the superconductor.

Khanna, S. M.↗

Interpolation Errors in Spectrum Analyzers

To obtain the proper measurement amplitude with a spectrum analyzer, the correct frequency-dependent transducer factor must be added to the voltage measured by the transducer. This report examines how entering transducer factors into a spectrum analyzer can cause significant errors in field amplitude due to the misunderstanding of the analyzer's interpolation methods. It also discusses how to reduce these errors to obtain a more accurate field amplitude reading.

Martin, J. L.↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with long cathodes in a high power, quasi-steady MPD discharge show that the critical current for the onset of voltage fluctuations, which was previously shown to be a function of cathode area, approaches an asymptote for cathodes of very large surface area. Floating potential measurements and photographs of the discharge luminosity indicate that the fluctuations are confined to the vicinity of the cathode and hence reflect a cathode emission process rather than a fundamental limit on MPD performance. Photoelectric measurements of particular argon neutral and ion transitions show that the higher electronic states are populated more heavily than would be calculated on the basis of Saha-Boltzmann equilibrium at the local electron temperature and number density. Preliminary optical depth measurements show that for a current of 4 kA and an argon mass flow of 12 g/sec, a population inversion exists between the upper and lower states of the 4880 A argon ion transition.

Jahn, R. G.↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with various cathodes and anodes in a high power, quasi-steady magnetoplasmadynamic (MPD) are discussed. The magnitude of the current at the onset of voltage fluctuations is shown to be an increasing function of cathode area and a weaker decreasing function of anode area. Tests with a fluted cathode indicated that the fluctuations originate in the plasma adjacent to the cathode rather than at the cathode surface. Measurements of radiative output from an optical cavity aligned to examine the current-carrying portion of a two-dimensional, 56 kA magnetoplasmadynamic discharge reveal no lasing in that region, consistent with calculations of electron excitation and resonance radiation trapping. A voltage-swept double probe technique allows single-shot determination of electron temperature and electron number density in the recombining MPD exhaust flow. Current distributions within the cavity of MPD hollow cathodes for various static prefills with no injected mass flow are examined.

Jahn, R. G.↗