Search NASA⌕ Search

SEARCH · Search NASA

Results for “Balancer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

32.9% Efficient Tandem Solar Cell with Strain-Balanced GaInAs/GaAsP Quantum Wells

We demonstrate single and dual junction solar cells with up to 80 strain-balanced GaInAs/GaAsP quantum wells (QWs), in order to extend the range of photon absorption. The net average stress in the quantum well layers is =12 MPa, despite coherent stresses in the individual layers that are 35-70 times greater. The GaAs-QW cell has a certified efficiency of (27.2 ± 0.2)% at one-sun; the GaInP/GaAs-QW tandem has a certified record one-sun efficiency of (32.9 ± 0.5)%. We will discuss the architecture of the devices, the physics behind the high performance, and pathways to further improvement.

III-V↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Evaluation of Production Cost Savings from Consolidation of Balancing Authorities in the US Western Interconnection under High Wind and Solar Penetration

This paper introduces a comprehensive analysis to quantify the potential savings in production cost due to consolidation of 32 US western interconnection Balancing Authorities (BAs). Three simulation scenarios are developed: current Western Electricity Coordinating Council (WECC) BAs structure, full copper-sheet consolidation, and full consolidation with transmission congestion considered. The study uses WECC Transmission Expansion Planning Policy Committee (TEPPC) model that was developed for the year 2020. The model assumes 8% wind and 3% solar energy penetration as percentage of total WECC demand in 2020. Sensitivity analyses are carried out to assess the impact of transmission hurdle rates between WECC BAs on potential benefits. The study shows savings that ranges from $400 Million (2.4% of total one year production cost) to $600 Million (3.2%) per year in thermal units production cost due to consolidation can be achieved. The copper sheet consolidation scenario shows an extra savings of $240 Million (1.4%) per year.

Balancing authorities, hurdle rates, economic disp↗

Imbalance Mechanism and Balanced Control of Capacitor Voltage for a Hybrid Modular Multilevel Converter

Due to different charging and discharging characteristics of full-bridge submodules and half-bridge submodules in hybrid modular multilevel converters (MMC), capacitor voltage imbalance will occur under boosted ac voltage or reduced dc voltage conditions. To address this issue, the mechanism of capacitor voltage imbalance is carefully studied, with three main factors-modulation index, power angle, and hybridization ratio-summarized and their effect on capacitor voltage imbalance analyzed. Further, a control strategy based on fundamental frequency reactive circulating current injection is proposed to keep the capacitor voltage balanced in the hybrid MMC. The amplitude and phase angle of the injected circulating current are calculated and their influence on the energy fluctuation in the submodules' capacitors and the semiconductors' current stress is explored. Lastly, experimental results under boosted ac voltage and reduced dc voltage conditions demonstrate the feasibility and validity of the proposed scheme.

42 ENGINEERING↗

COMPASS-U Global Heat Balance Calculations

COMPASS-U is a medium size, high magnetic field experimental tokamak (R = 0.9 m, B t = 5 T, and I p = 2 MA), built at the Institute of Plasma Physics, Czech Academy of Sciences (IPP-CAS). This global heat balance calculation for COMPASS-U was done at Princeton Plasma Physics Laboratory (PPPL). Based on our previous experience of building global thermal model for National Spherical Torus Experiment-Upgrade (NSTX-U) at PPPL, this 2-D global thermal model geometry represents a typical cross section of COMPASS-U machine. The model includes thermal radiation, conduction, and convection among components and also between the machine and outer environment. Helium gas heating/cooling was modeled with fluid element and surface element. This model was used to calculate component temperatures and heat distribution during heat up, cryogenic cool down, normal operation, and fault operation scenarios. Definition of 14 main thermal scenarios was provided by IPP-CAS. First nine are normal operation scenarios. Scenarios #10–#14 are fault scenarios. Results of thermal scenario #5 will be given and discussed in this article, including peak temperatures, temperature ratcheting, energy distribution, and required cooling power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reinforcement Learning for Load-balanced Parallel Particle Tracing

We explore an online reinforcement learning (RL) paradigm to dynamically optimize parallel particle tracing performance in distributed-memory systems. Our method combines three novel components: (1) a work donation algorithm, (2) a high-order workload estimation model, and (3) a communication cost model. First, we design an RL-based work donation algorithm. Our algorithm monitors workloads of processes and creates RL agents to donate data blocks and particles from high-workload processes to low-workload processes to minimize program execution time. The agents learn the donation strategy on the fly based on reward and cost functions designed to consider processes' workload changes and data transfer costs of donation actions. Second, we propose a workload estimation model, helping RL agents estimate the workload distribution of processes in future computations. Third, we design a communication cost model that considers both block and particle data exchange costs, helping RL agents make effective decisions with minimized communication costs. We demonstrate that our algorithm adapts to different flow behaviors in large-scale fluid dynamics, ocean, and weather simulation data. Our algorithm improves parallel particle tracing performance in terms of parallel efficiency, load balance, and costs of I/O and communication for evaluations with up to 16,384 processors.

Distributed and parallel particle tracing↗

Understanding the effects of PEMFC contamination from balance of plant assembly aids materials: In situ studies

In this study, in situ performance data were measured to assess the degree of contamination from leachates of five families of balance of plant (BOP) materials (i.e., 2-part adhesive, grease, thread lock/seal, silicone adhesive/seal and urethane adhesive/seal) broadly classified as assembly aids that may be used as adhesives and lubricants in polymer electrolyte membrane fuel cell (PEMFC) systems. Leachate solutions, derived from soaking the materials in deionized (DI) water at elevated temperature, were infused into the fuel cell to determine the effect of the leachates on fuel cell performance. During the contamination phase of the experiments, leachate solution was introduced through a nebulizer into the cathode feed stream of a 50 cm 2 PEMFC operating at 0.2 A/cm 2 at 80°C and 32%RH. Voltage loss and high frequency resistance (HFR) were measured as a function of time and electrochemical surface area (ECA) before and after contamination were compared. Two procedures of recovery, one self-induced recovery with DI water and one driven recovery through cyclic voltammetry (CV) were investigated. Finally, performance results measured before and after contamination and after CV recovery are compared and discussed.

14 SOLAR ENERGY↗

Scaling trends for balance-of-system costs at land-based wind power plants: Opportunities for innovations in foundation and erection

Wind power plant sizes, hub heights, and turbine ratings have increased since 2008 to optimize the cost and performance of wind power; however, the limits of these economies of scale remain unclear. Here, we explore how the costs incurred to install turbines at a wind power plant—the balance-of-system (BOS) costs—scale with turbine rating, hub height, and plant size. We also investigate how these changes in BOS costs influence the levelized cost of energy (LCOE). We show that increasing the plant size from 150 to 400 MW could reduce the BOS costs by 21%. We also show that if the foundation costs decreased by 50%, building a wind power plant with 5-MW turbines (having rotor diameters of 166 m and hub heights of 120 m) could decrease the LCOE by 5%. These results could help inform future BOS cost-reduction opportunities and thereby reduce future capital costs for land-based wind power.

17 WIND ENERGY↗

Profiling the BLAST bioinformatics application for load balancing on high-performance computing clusters

Abstract Background The Basic Local Alignment Search Tool (BLAST) is a suite of commonly used algorithms for identifying matches between biological sequences. The user supplies a database file and query file of sequences for BLAST to find identical sequences between the two. The typical millions of database and query sequences make BLAST computationally challenging but also well suited for parallelization on high-performance computing clusters. The efficacy of parallelization depends on the data partitioning, where the optimal data partitioning relies on an accurate performance model. In previous studies, a BLAST job was sped up by 27 times by partitioning the database and query among thousands of processor nodes. However, the optimality of the partitioning method was not studied. Unlike BLAST performance models proposed in the literature that usually have problem size and hardware configuration as the only variables, the execution time of a BLAST job is a function of database size, query size, and hardware capability. In this work, the nucleotide BLAST application BLASTN was profiled using three methods: shell-level profiling with the Unix “time” command, code-level profiling with the built-in “profiler” module, and system-level profiling with the Unix “gprof” program. The runtimes were measured for six node types, using six different database files and 15 query files, on a heterogeneous HPC cluster with 500+ nodes. The empirical measurement data were fitted with quadratic functions to develop performance models that were used to guide the data parallelization for BLASTN jobs. Results Profiling results showed that BLASTN contains more than 34,500 different functions, but a single function, RunMTBySplitDB, takes 99.12% of the total runtime. Among its 53 child functions, five core functions were identified to make up 92.12% of the overall BLASTN runtime. Based on the performance models, static load balancing algorithms can be applied to the BLASTN input data to minimize the runtime of the longest job on an HPC cluster. Four test cases being run on homogeneous and heterogeneous clusters were tested. Experiment results showed that the runtime can be reduced by 81% on a homogeneous cluster and by 20% on a heterogeneous cluster by re-distributing the workload. Discussion Optimal data partitioning can improve BLASTN’s overall runtime 5.4-fold in comparison with dividing the database and query into the same number of fragments. The proposed methodology can be used in the other applications in the BLAST+ suite or any other application as long as source code is available.

59 BASIC BIOLOGICAL SCIENCES↗

Optical heterodyne accelerometry: passively stabilized, fully balanced velocity interferometer system for any reflector

We formalize the physics of an optical heterodyne accelerometer that allows measurement of low and high velocities from material surfaces under high strain. The proposed apparatus incorporates currently common optical velocimetry techniques used in shock physics, with interferometric techniques developed to self-stabilize and passively balance interferometers in quantum cryptography. The result is a robust telecom-fiber-based velocimetry system insensitive to modal and frequency dispersion that should work well in the presence of decoherent scattering processes, such as from ejecta clouds and shocked surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mass Balance Accounting for CO2 Storage with Enhanced Oil Recovery in Northern Michigan

Battelle’s MRCSP Phase III monitoring efforts began on February 3, 2013, with an overarching goal of monitoring at least 1 million metric tons (MT) of net CO2 stored within Core Energy’s EOR complex. For the purposes of this report, most of the mass balance accounting data is shown through September 30, 2019, a period of 6 years, 10 months..

Bagley↗

Oxalate Mass Balance During Chemical Cleaning in Tank 5F

The Savannah River Site (SRS) is preparing Tank 5F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning to determine whether the tank is ready for closure. SRS personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. Analysis of the anions showed the measured oxalate removed from Tank 5F to be approximately 50% of the amount added in the oxalic acid. To close the oxalate mass balance, the author collected solid samples, leached them with nitric acid, and measured the concentration of cations and anions in the leachate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Steam Balancing and Tuning for Multifamily Residential Buildings in Chicagoland

Older heating systems often suffer from mis-investment—multiple contractors upgrading parts of systems in inadequate or inappropriate ways that reduce system functionality and efficiency—or from a lack of proper maintenance. This technical report addresses these barriers to information, contractor resources, and cost-savings. Building off of previous research, CNT Energy conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam; system balancing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of a Double Bubbler for Material Balance in Liquids (Training Report 2013)

The objective of this project was to determine the potential of a double bubbler to measure density and fluid level of the molten salt contained in an electrorefiner. Such in-situ real-time measurements can provide key information for material balances in the pyroprocessing of the nuclear spent fuel. This theoretical study showed this technique has a lot of promise. Four different experiments were designed and performed. The first three experiments studied the influence of a variety of factors such as depth difference between the two tubes, gas flow rate, the radius of the tubes and determining the best operating conditions. The last experiment purpose was to determine the precision and accuracy of the apparatus during specific conditions. The elected operating conditions for the characterization of the system were a difference of depth of 25 cm and a flow rate of 55 ml/min in each tube. The measured densities were between 1,000 g/l and 1,400g/l and the level between 34cm and 40 cm. The depth difference between the tubes is critical, the larger, the better. The experiments showed that the flow rate should be the same in each tube. The concordances with theoretical predictions were very good. The density precision was very satisfying (spread<0.1%) and the accuracy was about 1%. For the level determination, the precision was also very satisfying (spread<0.1%), but the accuracy was about 3%. However, those two biases could be corrected with calibration curves. In addition to the aqueous systems studied in the present work, future work will focus on examining the behavior of the double bubbler instrumentation in molten salt systems. The two main challenges which were identified in this work are the effect of the temperature and the variation of the superficial tension.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmarking Non-Hardware Balance-of-System (Soft) Costs for U.S. Photovoltaic Systems, Using a Bottom-Up Approach and Installer Survey – Second Edition

This report presents results from the second U.S. Department of Energy (DOE) sponsored, bottom-up data-collection and analysis of non-hardware balance-of-system costs -- often referred to as 'business process' or 'soft' costs -- for U.S. residential and commercial photovoltaic (PV) systems. In service to DOE's SunShot Initiative, annual expenditure and labor-hour-productivity data are analyzed to benchmark 2012 soft costs related to (1) customer acquisition and system design (2) permitting, inspection, and interconnection (PII). We also include an in-depth analysis of costs related to financing, overhead, and profit. Soft costs are both a major challenge and a major opportunity for reducing PV system prices and stimulating SunShot-level PV deployment in the United States. The data and analysis in this series of benchmarking reports are a step toward the more detailed understanding of PV soft costs required to track and accelerate these price reductions.

14 SOLAR ENERGY↗

California Energy Balance Update and Decomposition Analysis for the Industry and Building Sectors (Final Report)

This report on the California Energy Balance version 2 (CALEB v2) database documents the latest update and improvements to CALEB version 1 (CALEB v1) and provides a complete picture of how energy is supplied and consumed in the State of California. The CALEB research team at Lawrence Berkeley National Laboratory (LBNL) performed the research and analysis described in this report. CALEB manages highly disaggregated data on energy supply, transformation, and end-use consumption for about 40 different energy commodities, from 1990 to 2008. This report describes in detail California's energy use from supply through end-use consumption as well as the data sources used. The report also analyzes trends in energy demand for the "Manufacturing" and "Building" sectors. Decomposition analysis of energy consumption combined with measures of the activity driving that consumption quantifies the effects of factors that shape energy consumption trends. The study finds that a decrease in energy intensity has had a very significant impact on reducing energy demand over the past 20 years. The largest impact can be observed in the industry sector where energy demand would have had increased by 358 trillion British thermal units (TBtu) if subsectoral energy intensities had remained at 1997 levels. Instead, energy demand actually decreased by 70 TBtu. In the "Building" sector, combined results from the "Service" and "Residential" subsectors suggest that energy demand would have increased by 264 TBtu (121 TBtu in the "Services" sector and 143 TBtu in the "Residential" sector) during the same period, 1997 to 2008. However, energy demand increased at a lesser rate, by only 162 TBtu (92 TBtu in the "Services" sector and 70 TBtu in the "Residential" sector). These energy intensity reductions can be indicative of energy-efficiency improvements during the past 10 years. The research presented in this report provides a basis for developing an energy-efficiency performance index to measure progress over time in the State of California.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steam System Balancing and Tuning for Multifamily Residential Buildings in Chicagoland

Older heating systems often suffer from mis-investment--multiple contractors upgrading parts of systems in inadequate or inappropriate ways that reduce system functionality and efficiency--or from a lack of proper maintenance. This technical report addresses these barriers to information, contractor resources, and cost-savings. Building off of previous research, CNT Energy conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam system balancing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗