The German product quality control of the compacted metallic nuclear waste - 15311

The treatment and safe disposal of spent nuclear fuel is a key challenge of nuclear energy utilization and has to be accomplished regardless the future nuclear of electricity production or phase-out policies. Until June 2005 approx. 6662 tons of spent fuel from German nuclear power plants was sent to the La Hague (France) and Sellafield (UK) plants for reprocessing. An equivalent amount of nuclear waste compounds has contractually to be returned to Germany, which is currently in progress. The returnable waste streams comprise mainly highly-active vitrified waste containing a major part of fission products and actinides, and intermediate-active super-compacted metallic waste containing reprocessed fuel element's structural materials and some technological waste from the reprocessing process itself. Shearing and dissolution of spent fuel leaves scraps of fuel metal cladding, the end-pieces and spacers which are contaminated, activated and irradiating from their life in a reactor core. In fact, this metallic intermediate level radioactive waste makes up a bit more than half of the total volume of the reprocessed waste. At La Hague the metallic waste is super-compacted. Several, typically eight, compacted discs are stacked in a stainless steel container, named CSD-C as for 'Colis Standard de Dechets Compactes'. 4104 containers of such CSD-Cs in 152 transport/storages casks have to be returned to Germany. Each one of them has to be checked and quality certified for its conformity with German national product specifications and acceptance criteria by independent national product quality control inspectors (PKS). The residue package documentation has to be complete and the characterization methods have to be comprehensive. Due to the heterogeneity of metallic waste the characterization and control of its properties is very complex. The nuclear characterization is performed by means of non-destructive measurements, where only a few key nuclides are measured directly. In fact, the proper calculation of the whole nuclear inventory relies on numerous supplementary simulations. The measurement and calculation methodology is scrutinized by PKS in detail and key points are benchmarked with our own simulations for the sake of an independent nuclear inventory declaration check. With respect to the vast amount of documentation and parameters, which have to be checked and verified, PKS had to optimize their checking procedures. For this purpose dedicated proof tools have been developed that shall be applied for selected indicative cross-checks of the relevant parameters. This contribution is dedicated to the procedure of quality control by PKS and examples of actually performed computational verifications of declared nuclear inventory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minimizing Error Potential Using Computer Applications - 18498

Many Savannah River Site (SRS) liquid waste facility operations depend upon repetitive engineering calculations and operator actions. Although these calculations and actions are formalized in technical reports and paper procedures, they can still be vulnerable to data entry errors, calculation errors, equipment alignment errors, and occasional changes caused by different people performing these activities. Savannah River Remediation (SRR) is using computer automation to reduce these error precursors by standardizing repetitive calculations and by performing plant alignment checks for repetitive operation processes. Data entry can be automated, calculation methodologies can be standardized, and computers can check to see that predefined plant conditions exist before equipment operation. In addition to improving quality, the time required for these activities to generate technical reports, to perform independent reviews, and to perform equipment alignment checks can be significantly reduced. In the case of operator-performed calculations, error precursors involve distractions that can occur over a multi-page paper procedure, confusing displays and controls from equipment, mathematical errors, complacency, and unfamiliarity with the procedure among many others. Repetitive engineering calculations suffer from similar error precursors and are often compounded by high workloads, lack of proficiency, lack of standard methodology, mental shortcuts, and biases. Web-based computer applications can eliminate many of these precursors through standardization. Calculation methods are fixed, inputs are fixed, and computer checks can highlight potentially wrong inputs and outputs. Automated calculations are performed almost instantaneously once input is provided. Operators and engineers can spend more time focusing on the results than on the process to achieve the results. Similarly, when operators use repetitive procedures involving equipment manipulation, the same error precursors apply. Automated operation sequences and equipment checks can be programmed into the distributed control system to provide standard operating processes that reduce and eliminate error precursors. This paper describes how SRR incorporates Human Performance Improvement (HPI) principles when automating calculations and operation processes. Computer applications will be reviewed in detail, highlighting the software development life-cycle that includes requirements gathering, prototyping, design, development, testing, and implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a novel passive top-down uniflow scavenged two-stroke GDI engine

The design and performance characteristics of a novel top-down uniflow scavenged gasoline direct-injection two-stroke engine are presented. The novelty of the engine lies in the cylinder head that contains multiple check valves that control scavenging airflow into the cylinder from a supercharged air plenum. When the cylinder pressure drops below the intake plenum pressure during the expansion stroke, air flows into the cylinder through the check valves. During compression the cylinder pressure increases to a level above the intake plenum pressure and the check valves close preventing back-flow into the intake plenum. The engine head design provides asymmetrical intake valve timing without the use of poppet valves and the associated valve-train. In combination with an external Roots-type supercharger that supplies the plenum and exhaust ports at the bottom of the cylinder wall, the novel head provides top-down uniflow air scavenging. Motoring tests indicated that the check valves seal and the peak pressure is governed by the compression ratio. The only drawback observed is that valve closing is delayed as the engine speed increases. In order to investigate the valve dynamics, additional tests were performed in an optically-accessible cold flow test rig that enabled the direct measurement of valve opening and closing time under various conditions. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Initial plant community responses to hardwood control treatments in restoration of remnant longleaf pine (Pinus palustris) woodlands

Changes in land use over the past century have contributed to substantial losses of longleaf pine (Pinus palustris) woodlands in the southeastern USA and replacement with higher density, mixed pine and hardwood stands that suppress understory development and limit application of prescribed fire. To increase understanding of limiting factors and identify potential approaches for restoring longleaf pine woodlands, we studied in this work initial availability of light and soil water and 2-year (2018–2019) plant community responses after controlling overstory hardwoods in five remnant longleaf pine woodlands having no evidence of previous agriculture at the Savannah River Site near Aiken, SC, USA. Seven hardwood control treatments and a non-treated check were compared in a randomized compete block experiment: cutting, cutting + shredding of logging residues, stem injection with imazapyr herbicide, cutting + basal spray with imazapyr herbicide, cutting + basal spray with triclopyr herbicide, cutting + directed foliar spray with a mixture of glyphosate and imazapyr herbicides, and cutting + broadcast foliar spray with the same herbicide mixture. In the year prior to hardwood cutting (2016), understory light availability averaged 23% of full sun. Throughout the year of treatment installation (2017), average soil water content (SWC) was below permanent wilting point (5.5% SWC) where overstory hardwoods were retained; whereas, it was above wilting point (7.5%) where they had been cut. Thus, combined effects of shade and root competition from overstory hardwoods probably limited cover of herbaceous species in the non-treated check. In the 2 years following treatment, hardwood survival averaged > 99%, 62%, 42% and < 1% for the non-treated check, cutting, shredding, and herbicide treatments, respectively. Relative to the non-treated check, herbaceous species richness was increased by shredding, stem injection, basal spray, or directed foliar treatments; herbaceous cover was increased by basal spray or directed foliar treatments; and woody cover was decreased by directed or broadcast foliar treatments. The directed foliar spray was the most effective treatment for achieving many of the desired understory characteristics of a longleaf pine woodland, including a diverse understory dominated by herbaceous vegetation capable of supporting periodic prescribed fires. Although the imazapyr basal spray treatment increased cover of remnant woodland indicator species, none of the treatments increased richness of this species group, suggesting that restoration of native species composition will be expedited by enrichment seedings or plantings.

60 APPLIED LIFE SCIENCES↗

The Diagnostic Method of Inner Parts of Welded Joints at Nuclear Power Plant

There is no possibility to check any inner part at real welded joint at nuclear power station (NPS) during operation because any destructive test cannot be used. In practice there is checked surface of weld. There are used four methodical instructions for the check of real welds: 1. The visual inspection, 2. The measurement of hardness, 3. The chemical composition checking and 4. The microstructure replica analysis. It is necessary to know how these information of weld surface are in accordance with characteristics of inner parts of weld. If there is not any difference between surface weld microstructure and internal weld microstructure of experimental weld it is supposed to that there is not any difference in other measured properties of welds. If is changed structural characteristics of microstructure, it is changed also hardness, chemical analysis etc. It was observed that the microstructure of real welds is almost the same with simulated weld and also the surface microstructure of experimental weld is in accordance with microstructure of inner parts of this weld. It can be supposed extension of lifetime of NPS if there is not any difference between replicas microstructure taken after six year operation of NPS and microstructure of inner parts of simulated weld is almost the same with surface microstructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DISTRIBUTED FLAMES IN TYPE Ia SUPERNOVAE

At a density near a few x10{sup 7} g cm{sup -3}, the subsonic burning in a Type Ia supernova (SN) enters the distributed regime (high Karlovitz number). In this regime, turbulence disrupts the internal structure of the flame, and so the idea of laminar burning propagated by conduction is no longer valid. The nature of the burning in this distributed regime depends on the turbulent Damkoehler number (Da{sub T}), which steadily declines from much greater than one to less than one as the density decreases to a few x10{sup 6} g cm{sup -3}. Classical scaling arguments predict that the turbulent flame speed s{sub T} , normalized by the turbulent intensity u-check, follows s{sub T}/u-check = Da{sub T}{sup 1/2} for Da{sub T} {approx}< 1. The flame in this regime is a single turbulently broadened structure that moves at a steady speed, and has a width larger than the {integral} scale of the turbulence. The scaling is predicted to break down at Da{sub T} {approx} 1, and the flame burns as a turbulently broadened effective unity Lewis number flame. This flame burns locally with speed s{sub l}ambda and width l{sub l}ambda, and we refer to this kind of flame as a lambda-flame. The burning becomes a collection of lambda-flames spread over a region approximately the size of the {integral} scale. While the total burning rate continues to have a well-defined average, s{sub T}{approx}u-check, the burning is unsteady. We present a theoretical framework, supported by both one-dimensional and three-dimensional numerical simulations, for the burning in these two regimes. Our results indicate that the average value of s{sub T} can actually be roughly twice u-check for Da{sub T} {approx}> 1, and that localized excursions to as much as 5 times u-check can occur. We also explore the properties of the individual flames, which could be sites for a transition to detonation when Da{sub T} {approx} 1. The lambda-flame speed and width can be predicted based on the turbulence in the star (specifically the energy dissipation rate epsilon*) and the turbulent nuclear burning timescale of the fuel tau {sup T}{sub nuc}. We propose a practical method for measuring s{sub l}ambda and l{sub l}ambda based on the scaling relations and small-scale computationally inexpensive simulations. This suggests that a simple turbulent flame model can be easily constructed suitable for large-scale distributed SNe flames. These results will be useful both for characterizing the deflagration speed in larger full-star simulations, where the flame cannot be resolved, and for predicting when detonation occurs.

79 ASTRONOMY AND ASTROPHYSICS↗

An analysis of the control hierarchy modelling of the CMS detector control system

The supervisory level of the Detector Control System (DCS) of the CMS experiment is implemented using Finite State Machines (FSM), which model the behaviours and control the operations of all the sub-detectors and support services. The FSM tree of the whole CMS experiment consists of more than 30.000 nodes. An analysis of a system of such size is a complex task but is a crucial step towards the improvement of the overall performance of the FSM system. This paper presents the analysis of the CMS FSM system using the micro Common Representation Language 2 (mcrl2) methodology. Individual mCRL2 models are obtained for the FSM systems of the CMS sub-detectors using the ASF+SDF automated translation tool. Different mCRL2 operations are applied to the mCRL2 models. A mCRL2 simulation tool is used to closer examine the system. Visualization of a system based on the exploration of its state space is enabled with a mCRL2 tool. Requirements such as command and state propagation are expressed using modal mu-calculus and checked using a model checking algorithm. For checking local requirements such as endless loop freedom, the Bounded Model Checking technique is applied. This paper discusses these analysis techniques and presents the results of their application on the CMS FSM system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Consistency testing for robust phase estimation

In this work, we present an extension to the robust phase estimation protocol, which can identify incorrect results that would otherwise lie outside the expected statistical range. Robust phase estimation is increasingly a method of choice for applications such as estimating the effective process parameters of noisy hardware, but its robustness is dependent on the noise satisfying certain threshold assumptions. We provide consistency checks that can indicate when those thresholds have been violated, which can be difficult or impossible to test directly. We test these consistency checks for several common noise models, and identify two possible checks with high accuracy in locating the point in a robust phase estimation run at which further estimates should not be trusted. One of these checks may be chosen based on resource availability, or they can be used together in order to provide additional verification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lazy Checkpointing: Exploiting Temporal Locality in Failures to Mitigate Checkpointing Overheads on Extreme-Scale Systems, In: 2014 44th Annual IEEE/IFIP International Conference on Dependable Systems and Networks

Continuing increase in the computational power of supercomputers has enabled large-scale scientific applications in the areas of astrophysics, fusion, climate and combustion to run larger and longer-running simulations, facilitating deeper scientific insights. However, these long-running simulations are often interrupted by multiple system failures. Therefore, these applications rely on "check pointing'" as a resilience mechanism to store application state to permanent storage and recover from failures. Unfortunately, check pointing incurs excessive I/O overhead on supercomputers due to large size of checkpoints, resulting in a sub-optimal performance and resource utilization. In this paper, we devise novel mechanisms to show how check pointing overhead can be mitigated significantly by exploiting the temporal characteristics of system failures. We provide new insights and detailed quantitative understanding of the check pointing overheads and trade-offs on large-scale machines. Our prototype implementation shows the viability of our approach on extreme-scale machines.

Computer Science↗

SU-E-T-432: A Rapid and Comprehensive Procedure for Daily Proton QA

Purpose: The objective is to develop a rapid and comprehensive daily QA procedure implemented at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. Methods: A scribed phantom with imbedded fiducials is used for checking lasers accuracy followed by couch isocentricity and for X-ray imaging congruence with isocenter. A Daily QA3 device (Sun Nuclear, FL) was used to check output, range and profiles. Five chambers in the central region possess various build-ups. After converting the thickness of the inherent build-ups into water equivalent thickness (WET) for proton, range of any beam can be checked with additional build-up on the Daily QA3 device. In our procedure, 3 beams from 3 bands (large, small and deep) with nominal range of 20 cm are checked daily. 17cm plastic water with WET of 16.92cm are used as additional build-up so that four chambers sit on the SOBP plateau at various depths and one sit on the distal fall off. Reading from the five chambers are fitted to an error function that has been parameterized to match the SOBP with the same nominal range. Shifting of the error function to maximize the correlation between measurements and the error function is deemed as the range shift from the nominal value. Results: We have found couch isocentricity maintained over 180 degrees. Imaging system exhibits accuracy in regard to imaging and mechanical isocenters. Ranges are within 1mm accuracy from measurements in water tank, and sensitive to change of sub-millimeter. Data acquired since the start of operation show outputs, profiles and range stay within 1% or 1mm from baselines. The whole procedure takes about 40 minutes. Conclusion: Taking advantage of the design of Daily QA3 device turns the device originally designed for photon and electron into a comprehensive and rapid tool for proton daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-502: Biometrically Accepted Patient Records

Purpose: To implement a clinically useful palm vein pattern recognition biometric system to treat the correct treatment plan to the correct patient each and every time and to check-in the patient into the department to access the correct medical record. Methods: A commercially available hand vein scanning system was paired to Aria and utilized an ADT interface from the hospital electronic health system. Integration at two points in Aria, version 11 MR2, first at the appointment tracker screen for the front desk medical record access and second at the queue screen on the 4D treatment console took place for patient daily time-out. A test patient was utilized to check accuracy of identification as well as to check that no unintended interactions take place between the 4D treatment console and the hand vein scanning system. This system has been in clinical use since December 2013. Results: Since implementation, 445 patients have been enrolled into our biometric system. 95% of patients learn the correct methodology of hand placement on the scanner in the first try. We have had two instances of patient not found because of a bad initial scan. We simply erased the scanned metric and the patient enrolled again in those cases. The accuracy of the match is 100% for each patient, we have not had one patient misidentified. We can state this because we still use patient photo and date of birth as identifiers. A QA test patient is run monthly to check the integrity of the system. Conclusion: By utilizing palm vein scans along with the date of birth and patient photo, another means of patient identification now exits. This work indicates the successful implementation of technology in the area of patient safety by closing the gap of treating the wrong plan to a patient in radiation oncology. FOJP Service Corporation covered some of the costs of the hardware and software of the palm vein pattern recognition biometric system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-G-BRE-05: Clinical Process Improvement and Billing in Radiation Oncology: A Case Study of Applying FMEA for CPT Code 77336 (continuing Medical Physics Consultation)

Purpose: The improvement of quality in healthcare can be assessed by Failure Mode and Effects Analysis (FMEA). In radiation oncology, FMEA, as applied to the billing CPT code 77336, can improve both charge capture and, most importantly, quality of the performed services. Methods: We created an FMEA table for the process performed under CPT code 77336. For a given process step, each member of the assembled team (physicist, dosimetrist, and therapist) independently assigned numerical values for: probability of occurrence (O, 1–10), severity (S, 1–10), and probability of detection (D, 1–10) for every failure mode cause and effect combination. The risk priority number, RPN, was then calculated as a product of O, S and D from which an average RPN was calculated for each combination mentioned above. A fault tree diagram, with each process sorted into 6 categories, was created with linked RPN. For processes with high RPN recommended actions were assigned. 2 separate R and V systems (Lantis and EMR-based ARIA) were considered. Results: We identified 9 potential failure modes and corresponding 19 potential causes of these failure modes all resulting in unjustified 77336 charge and compromised quality of care. In Lantis, the range of RPN was 24.5–110.8, and of S values – 2–10. The highest ranking RPN of 110.8 came from the failure mode described as “end-of-treatment check not done before the completion of treatment”, and the highest S value of 10 (RPN=105) from “overrides not checked”. For the same failure modes, within ARIA electronic environment with its additional controls, RPN values were significantly lower (44.3 for end-of-treatment missing check and 20.0 for overrides not checked). Conclusion: Our work has shown that when charge capture was missed that also resulted in some services not being performed. Absence of such necessary services may result in sub-optimal quality of care rendered to patients.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center.

60 APPLIED LIFE SCIENCES↗

SU-E-J-199: A Software Tool for Quality Assurance of Online Replanning with MR-Linac

Purpose: To develop a quality assurance software tool, ArtQA, capable of automatically checking radiation treatment plan parameters, verifying plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary MU calculation considering the effect of magnetic field from MR-Linac, and verifying the delivery and plan consistency, for online replanning. Methods: ArtQA was developed by creating interfaces to TPS (e.g., Monaco, Elekta), R&V system (Mosaiq, Elekta), and secondary MU calculation system. The tool obtains plan parameters from the TPS via direct file reading, and retrieves plan data both transferred from TPS and recorded during the actual delivery in the R&V system database via open database connectivity and structured query language. By comparing beam/plan datasets in different systems, ArtQA detects and outputs discrepancies between TPS, R&V system and secondary MU calculation system, and delivery. To consider the effect of 1.5T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA is capable of automatically checking plan integrity and logic consistency, detecting plan data transfer errors, performing secondary MU calculations with or without a transverse magnetic field, and verifying treatment delivery. The tool is efficient and effective for pre- and post-treatment QA checks of all available treatment parameters that may be impractical with the commonly-used visual inspection. Conclusion: The software tool ArtQA can be used for quick and automatic pre- and post-treatment QA check, eliminating human error associated with visual inspection. While this tool is developed for online replanning to be used on MR-Linac, where the QA needs to be performed rapidly as the patient is lying on the table waiting for the treatment, ArtQA can be used as a general QA tool in radiation oncology practice. This work is partially supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-251: Developing a Daily Proton Beam Monitoring System

Purpose: To develop a daily monitoring system for proton beam output check and beam uniformity check. Methods: Designed for continuously irradiated photon and electron beams with a field size of 20 cm x 20 cm, the daily output checker (Sun Nuclear, Inc.) is not suitable for monitoring proton beams with inter-pulse beam-off and a field size smaller than 14–16 cm in diameter. To allow such proton beam monitoring, the following tests were performed. 1. Absolute dose and array calibrations which accept continuous irradiation only, were performed using photon beams. 2. Five ion chambers within the central area of 8 cm x 8 cm were utilized to check constancy of output at the center of beam modulation and at distal edge and to check beam symmetry and flatness. 3. To simplify our evaluation, the array calibration was manually modified, such that all five chambers report equal values in spite of their differences in build-up thicknesses. 4. The chamber at the lower-right corner is placed under a buildup thickness that can offer dose measurement at the distal edge. This buildup thickness was determined by proton beam range measurements, which established buildup thickness for beam output measurement at the central chamber and range measurement at the corner chamber. 5. The beam-off delay which allows receipt of pulsed irradiation was activated and optimal delay times were determined for each proton beam at 149.6, 185.6, and 249.5 MeV. Results: The above system was tested by miss-steering proton beams and altering phantom thickness by 1 mm at a time. The system reliably monitored the beam with: 3% tolerance for beam flatness, symmetry and output. The range difference of 0.5 mm could be detected at all energies by setting a tolerance of 20%. Conclusion: A quick daily proton beam monitoring system was feasible.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-636: ProteusONE Machine QA Procedure and Stabiity Study: Half Year Clinical Operation

Purpose: The objective of this study is to evaluate the stability of ProteusOne, the 1st commercial PBS proton system, throughout the daily QA and monthly over 6 month clinical operation. Method: Daily QA test includes IGRT position/repositioning, output in the middle of SOBP, beam flatness, symmetry, inplane and crossplane dimensions as well as energy range check. Daily range shifter QA consist of output, symmetry and field size checks to make sure its integrity. In 30 mins Daily QA test, all the measurements are performed using the MatriXXPT (IBA dosimetry). The data from these measurement was collected and compare over the first 6 month of clinical operation. In addition to the items check in daily QA, the summary also includes the monthly QA gantry star shots, absolute position check using a novel device, XRV-100. Results: Average machine output at the center of the spread out bragg peak was 197.5±.8 cGy and was within 1%of the baseline at 198.4 cGy. Beam flatness was within 1% cross plane with an average of 0.67±0.12% and 2% in-plane with an average of 1.08±0.17% compared to baseline measurements of 0.6 and 1.03, respectively. In all cases the radiation isocenter shift was less than or equal to 1mm. Output for the range shifter was within 2% for each individual measurement and averaged 34.4±.2cGy compare to a baseline reading of 34.5cGy. The average range shifter in and cross plane field size measurements were 19.8±0.5cm and 20.5±0.4cm compared with baseline values of 20.19cm and 20.79cm, respectively. Range shifter field symmetry had an average of less 1% for both in-plane and cross plane measurements. Conclusion: All machine metrics over the past 6 months have proved to be stable. Although, some averages are outside the baseline measurement they are within 1% tolerance and the deviation across all measurements is minimal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-649: Quality Assurances for Proton Therapy Delivery Equipment

Purpose: The number of proton therapy centers has increased dramatically over the past decade. Currently, there is no comprehensive set of guidelines that addresses quality assurance (QA) procedures for the different technologies used for proton therapy. The AAPM has charged task group 224 (TG-224) to provide recommendations for QA required for accurate and safe dose delivery, using existing and next generation proton therapy delivery equipment. Methods: A database comprised of QA procedures and tolerance limits was generated from many existing proton therapy centers in and outside of the US. These consist of proton therapy centers that possessed double scattering, uniform scanning, and pencil beams delivery systems. The diversity in beam delivery systems as well as the existing devices to perform QA checks for different beam parameters is the main subject of TG-224. Based on current practice at the clinically active proton centers participating in this task group, consensus QA recommendations were developed. The methodologies and requirements of the parameters that must be verified for consistency of the performance of the proton beam delivery systems are discussed. Results: TG-224 provides procedures and QA checks for mechanical, imaging, safety and dosimetry requirements for different proton equipment. These procedures are categorized based on their importance and their required frequencies in order to deliver a safe and consistent dose. The task group provides daily, weekly, monthly, and annual QA check procedures with their tolerance limits. Conclusions: The procedures outlined in this protocol provide sufficient information to qualified medical physicists to perform QA checks for any proton delivery system. Execution of these procedures should provide confidence that proton therapy equipment is functioning as commissioned for patient treatment and delivers dose safely and accurately within the established tolerance limits. The report will be published in late 2015.

62 RADIOLOGY AND NUCLEAR MEDICINE↗