Search NASA⌕ Search

SEARCH · Search NASA

Results for “High-performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Pathways for Sustainable Reaction Kinetics in Li-CO2 Batteries

Lithium-carbon dioxide (Li-CO2) batteries hold great promise for high-energy-density storage applications. However, advancing this technology as a sustainable alternative to Li-ion systems requires a deeper understanding of the underlying reaction mechanisms, which remain elusive. A key challenge stems from the added complexity introduced by the presence of oxygen (O2) in CO2 environment. In this study, we employed a stable Cu3(VBi)0.5Se4 mid-entropy catalyst and conducted a comprehensive investigation to uncover the underlying reaction mechanisms in Li-CO2 batteries under varying CO2/O2 ratios. Under pure CO2 conditions, the battery exhibits excellent rechargeability, sustaining up to 1200 cycles. However, at high current densities, the discharge potential drops significantly (below 2.0 V), primarily due to sluggish reaction kinetics caused by solid carbon formation. Interestingly, introducing O2 mitigates this limitation, leading to a 58% increase of the discharge potential (from 1.7 V to 2.7 V) at the high current density of 0.8 mA/cm2, signifying a substantial boost in energy output. Our results reveal that the reactions follow distinct pathways, shifting from surface- to solution-based mechanism, and may even exhibit coexistence of both mechanisms, depending on the CO2/O2 ratio. These findings offer new insights for designing high-performance and sustainable Li-gas batteries utilizing CO2 and O2 mixtures.

Ngo, Anh [University of illinois Chicago]↗

G2CFX Final Technical Report - Release

The primary objective of this project is to develop a process for production of high-performance, high-value carbon derived from wellhead natural gas. This will be done either by direct graphitization of pyrolysis carbon produced at the wellhead, or through precipitation of the carbon from a molten metal solution to form high-value graphite.

03 NATURAL GAS↗

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine Learning-Driven Optimization of Building Enclosures for Moisture Durability and Thermal Performance

The design of moisture-durable building enclosures with low embodied carbon often involves an iterative process of selecting the materials for the specific exposure conditions to meet the performance requirements. While hygrothermal simulations are commonly used to evaluate moisture durability, they often require advanced expertise for proper implementation. Machine learning (ML) provides a promising alternative by streamlining the design process and minimizing the reliance on complex simulations. This study presents a machine learning-based approach for predicting moisture durability in residential wall assemblies. The ML model was trained to estimate the mold index and maximum moisture content of various layers under typical exposure conditions. The model achieved a high predictive accuracy, with a coefficient of determination (R²) exceeding 0.90 when compared to traditional hygrothermal simulations on materials that were not part of training the ML model. Building on these results, the ML model was developed into a practical tool for optimizing wall assembly designs. This tool allows users to automatically optimize material selections based on energy, moisture, and carbon performance criteria. By incorporating multi-objective optimization, the tool identifies configurations that minimize embodied carbon while maintaining moisture safety and code-compliant thermal performance. Additionally, it provides insights into how material choices influence assembly durability, energy efficiency, and carbon reduction. The tool will be implemented in the Building Science Advisor (BSA) to enhance its performance and provide more granularity on the results. This research highlights the potential for ML-driven tools to simplify the design of high-performance building enclosures, offering architects and engineers a faster, more efficient way to balance critical performance factors.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.

97 - MATHEMATICS AND COMPUTING↗

Single Primary Heat Extraction and Removal Emulator (SPHERE) Long Duration Testing

For the development of heat-pipe cooled microreactors, it is crucial to thoroughly understand the characteristics and functioning of heat pipes across a wide spectrum of operating conditions. Passive heat removal and its long-term performance stability are critical factors in this context. Enhanced experimental data is vital for evaluating the operational lifespan of alkali metal heat pipes. Idaho National Laboratory (INL) has successfully conducted an extended duration test on a high-performance sodium-filled heat pipe, closely monitoring the axial temperature profile, power supplied by the heaters, and heat removed by a gas-gap calorimeter. The results from this testing provide valuable data that are instrumental in supporting heat pipe validation efforts. Specifically, this data aids in the development and validation of Sockeye, the Multiphysics Object-Oriented Simulation Environment (MOOSE) tool under the US-DOE NEAMS program designed for heat pipe modeling. By comparing experimental results with Sockeye’s predictions, the tool's accuracy and reliability can be assessed and improved, thereby enhancing its capability to simulate heat pipe operations under various conditions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

REFRACTORY COMPACT HEAT EXCHANGERS WITH EMBEDDED SENSORS ENABLED BY HYBRID ADVANCED SINTERING AND ADDITIVE APPROACH

Structural health monitoring (SHM) of compact heat exchangers (CHXs) operating in extreme environments is essential for ensuring system reliability, safety, and longevity. This study presents the development of high-temperature sensors fabricated via aerosol jet printing (AJP) using platinum ink, selected for its exceptional thermal stability, oxidation resistance, and electrical conductivity. AJP enables precise deposition of fine-feature sensor patterns onto complex geometries, making it well-suited for integration within CHX architectures. To enhance sensor durability, an alumina-based ceramic protective layer was printed over the platinum sensing elements. The sensors demonstrated stable, repeatable performance up to 900?°C during extended thermal cycling. A custom test setup was developed to evaluate sensor accuracy and robustness under steady-state and transient conditions. Substrate screening identified HG-1 ceramic-coated stainless steel as the most effective platform, offering strong adhesion and low resistance. Furthermore, electric field-assisted sintering (EFAS) was employed to embed the sensors into stainless steel 316L matrices without degrading their functionality. Post-embedding electrical tests confirmed sensor integrity, and initial characterization suggests strong potential for in-situ monitoring. This work provides a scalable strategy for integrating high-performance temperature sensors directly into refractory components, advancing embedded SHM technologies for harsh operating environments.

36 - MATERIALS SCIENCE↗

Compressing Vision Transformers in Geospatial Transfer Learning with Manifold-Constrained Optimization

Deploying geospatial foundation models on resource-constrained edge devices demands compact architectures that maintain high downstream performance. However, their large parameter counts and the accuracy loss often induced by compression limit practical adoption.In this work, we leverage manifold-constrained optimization framework DLRT to compress large vision transformer–based geospatial foundation models during transfer learning. By enforcing structured low-dimensional parameterizations aligned with downstream objectives, this approach achieves strong compression while preserving task-specific accuracy. We show that the method outperforms of-the-shelf low-rank methods as LoRA. Experiments on diverse geospatial benchmarks confirm substantial parameter reduction with minimal accuracy loss, enabling high-performing, on-device geospatial models.

Snyder, Thomas [Yale University]↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2025

A summary of NLR's stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, capability upgrades, and examples of R&D impact. 2025 brought a national focus on energy and ESIF is meeting the moment. All eyes are on data centers and domestic manufacturing and bringing the benefits of artificial intelligence to power system planning and operations. In step with national priorities, ESIF is building out capabilities that advance secure, reliable, and affordable power. ESIF hosted 190 multidisciplinary research projects, 855 high-performance computer users, and collaborated with 81 partners from industry, academia, research, and federal agencies. These research projects resulted in an AI method for detecting high-impedance faults with 90% accuracy, a grid controls demonstration in Connecticut, power quality validation of CorePower's flagship inductor, and a cybersecurity assessment of potential rogue capabilities in digitally connected energy devices. Facility infrastructure improvements enhanced the thermal research network, the SCADA system, the cyber range, power hardware-in-the-loop testing, and more. With support from the U.S Department of Energy (DOE), the ESIF laboratories continue to deliver leading solutions for secure, reliable, and affordable power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.

97 - MATHEMATICS AND COMPUTING↗

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

Classic and Quantum Task-Based Intelligent Runtime for QIRs Running on Multiple QPUs

High-performance computing systems are rapidly evolving into heterogeneous platforms that fuse quantum accelerators with traditional classical processing units (CPUs) and graphical processing units (GPUs). This convergence calls for runtimes capable of managing both classical and quantum workloads in a unified manner. We introduce an intelligent, task-based runtime that marries the Intelligent RuntIme System (IRIS) asynchronous scheduler with a quantum programming stack through the Quantum Intermediate Representation Execution Engine (QIR-EE). Our design allows programs written in the quantum intermediate representation (QIR) to be dispatched concurrently to a variety of back-ends, including multiple quantum simulators and nascent quantum processors, enabling genuine hybrid execution on a single node. To illustrate its practicality, we partition a 4-qubit and 20-qubit circuit into three sub-circuits using quantum circuit cutting via the QCut library. Each sub-circuit is simulated independently by the QIR-EE driver within IRIS, after which a classical post-processing step merges the simulation results to recover the outcome of the original full-circuit computation. This case study demonstrates how finer task granularity can enable the parallel execution and lower the simulation burden per quantum task while preserving overall accuracy, highlighting the feasibility of our hybrid approach.

Miniskar, Narasinga Rao [ORNL] (ORCID:000000018259↗

Development of Innovative Non-Concentrated Alloy (NCA) Fuel Cladding for Advanced Nuclear Reactors

As the nuclear energy sector advances toward next-generation reactors, the need for high-performance fuel cladding materials has become increasingly urgent. Traditional alloys like zirconium and stainless steel are reaching their performance limits under higher temperatures, more corrosive coolants, and extended irradiation. This report presents the development of a new class of fuel cladding materials based on Non-Concentrated Alloys (NCAs) ? multi-element systems designed to deliver enhanced mechanical strength, corrosion resistance, and radiation tolerance. Through a combination of computational modeling (Computer Coupling of Phase Diagrams and Thermochemistry: CALPHAD), simulation-guided alloy selection, and experimental fabrication via arc melting and spark plasma sintering (SPS), three strategic alloy design paths were explored: (1) FeCrAl-based NCAs, (2) refractory-lean neutron-efficient alloys, and (3) equimolar high-entropy compositions. Microstructural analysis confirmed the formation of stable body-centered cubic BCC_A2 phases, while mechanical testing demonstrated hardness values significantly exceeding those of conventional cladding materials. The results highlight the tunability of NCA systems and their potential for balancing strength and ductility ? a critical consideration for in-reactor performance. Looking forward, future work will focus on thermomechanical optimization, CALPHAD refinement, and benchmarking against industry standards to enable scalable deployment. This work not only advances the science of nuclear materials but also supports broader goals in nuclear safety, performance, and nuclear energy innovation.

36 - MATERIALS SCIENCE↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons learned from the development and implementation of a workforce training curriculum for advanced controls for high performance HVAC systems

Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.

Casillas, Armando↗