Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Cascading Tesla Oscillating Flow Diode for Stirling Engine Gas Bearings

Replacing the mechanical check-valve in a Stirling engine with a micromachined, non-moving-part flow diode eliminates moving parts and reduces the risk of microparticle clogging. At very small scales, helium gas has sufficient mass momentum that it can act as a flow controller in a similar way as a transistor can redirect electrical signals with a smaller bias signal. The innovation here forces helium gas to flow in predominantly one direction by offering a clear, straight-path microchannel in one direction of flow, but then through a sophisticated geometry, the reversed flow is forced through a tortuous path. This redirection is achieved by using microfluid channel flow to force the much larger main flow into this tortuous path. While microdiodes have been developed in the past, this innovation cascades Tesla diodes to create a much higher pressure in the gas bearing supply plenum. In addition, the special shape of the leaves captures loose particles that would otherwise clog the microchannel of the gas bearing pads.

Dyson, Rodger↗

Mass and Momentum Transport in Microcavities for Diffusion-Dominant Cell Culture Applications

For the informed design of microfluidic devices, it is important to understand transport phenomena at the microscale. This letter outlines an analytically-driven approach to the design of rectangular microcavities extending perpendicular to a perfusion microchannel for microfluidic cell culture devices. We present equations to estimate the spatial transition from advection- to diffusion-dominant transport inside cavities as a function of the geometry and flow conditions. We also estimate the time required for molecules, such as nutrients or drugs to travel from the microchannel to a given depth into the cavity. These analytical predictions can facilitate the rational design of microfluidic devices to optimize and maintain long-term, physiologically-based culture conditions with low fluid shear stress.

Yew, Alvin G.↗

APES: Acute Precipitating Electron Spectrometer - A High Time Resolution Monodirectional Magnetic Deflection Electron Spectrometer

We present a description of the Acute Precipitating Electron Spectrometer (APES) that was designed and built for the Ground-to-Rocket Electron Electrodynamics Correlative Experiment (GREECE) auroral sounding rocket mission. The purpose was to measure the precipitating electron spectrum with high time resolution, on the order of milliseconds. The trade-off made in order to achieve high time resolution was to limit the aperture to only one look direction. The energy selection was done by using a permanent magnet to separate the incoming electrons, such that the different energies would fall onto different regions of the microchannel plate and therefore be detected by different anodes. A rectangular microchannel plate (MCP) was used (15 mm x 100 mm), and there was a total of 50 discrete anodes under the MCP, each one 15 mm x 1.5 mm, with a 0.5 mm spacing between anodes. The target energy range of APES was 200 eV to 30 keV.

Michell, R. G.↗

Experimental Characterization of Surface Roughness and Geometric Evaluations of Thin-Wall Laser Powder Directed Energy Deposition

Additive Manufacturing (AM) has offered many new design and manufacturing opportunities for components across various industries. As AM evolves there is a need to better understand outputs of the process including geometric limitations and surface roughness based on specific application requirements. One possible application area of AM are components using thin-wall (<2 mm) microchannel heat exchangers for subsystems across aerospace, and industrial applications. AM offers the opportunity to significantly reduce the cost and lead time associated with fabricating these complex parts with internal features such as an array of cooling channels. Laser Powder Bed Fusion (L-PBF) has been continuously demonstrated as a technique to fabricate heat exchangers with internal geometric complexities. However, L-PBF is limited in the scale at which parts can be fabricated. Laser Powder Directed Energy Deposition (LP-DED) has been demonstrated as an AM technology to significantly increase the scale of which thin-wall microchannel heat exchangers could be manufactured. Successful deployment of the LP-DED technology requires critical understanding of the resulting features from the build process. Surface roughness is one of the critical areas that effects the friction factor and pressure drop within a heat exchanger and must be well understood. This presentation will provide an overview of the characterization work completed to understand the LP-DED process for thin-walls representative of hydrogen resistant alloy NASA HR-1 that would be used in a Hydrogen-environment application. An overview of the experiments conducted with varying LP-DED parameters, evaluation of various geometric channel and geometric build features and resulting surface finish will be provided along with a summary of conclusions from these experiments. Results indicate that powder size is a major contributor and surface roughness varies between closed channel shapes and external surfaces.

Directed Energy Deposition↗

Insulator-based DEP with impedance measurements for analyte detection

Disclosed herein are microfluidic devices for assaying at least one analyte specie in a sample comprising at least one analyte concentration area in a microchannel having insulating structures on or in at least one wall of the microchannel which provide a nonuniform electric field in the presence of an electric field provided by off-chip electrodes; and a pair of passivated sensing electrodes for impedance detection in a detection area. Also disclosed are assay methods and methods of making.

Davalos, Rafael V↗

Pulsed X-ray Characterization of Stripline Micro-Channel Plate Gated Imager

We report on characterization of x-ray imaging arrays developed by National Security Technologies, LLC. These devices are based on a microchannel plate (MCP) with a conventional glass microchannel structure, but the top and bottom conductive coatings, rather than covering the entire area, are configured into several (4 to 8) parallel strips. Since the bias voltage is a pulse launched from one end, these operate as striplines; relative delays between these pulses give different active exposure times. Unlike the case of a static bias voltage, non-uniformities in impedance along a stripline will produce spatial fluctuations in the bias voltage. These are expected to be slight, but the very sensitive dependence of gain on voltage - approximately like Vl/4d, where l and d are the length and diameter of the channel - means there may be very significant spatial non-uniformities in gain. Flat-field calibrations are therefore required so that such effects can be unfolded from the raw images if quantitative data is required. Such flat-field and other characterization measurements, e.g. responsivity and linearity, have therefore been done with a flash X-ray radiographic system. The maximum endpoint energy is 500 keV. The duration is {approx}40 ns, and so is essentially flat (temporally) during the MCP stripline transit time, which is a maximum of 600 ps. Spatial variations are significant, but the data are corrected using independent flat-field measurements. A monochromator selects a particular X-ray transition line (typically K{alpha}) of the anode material, so that characterizations can be done for various well-defined input photon energies.

47 OTHER INSTRUMENTATION↗

Combustor liner cooling system

A combustor liner is disclosed. The combustor liner includes an upstream portion, a downstream end portion extending from the upstream portion along a generally longitudinal axis, and a cover layer associated with an inner surface of the downstream end portion. The downstream end portion includes the inner surface and an outer surface, the inner surface defining a plurality of microchannels. The downstream end portion further defines a plurality of passages extending between the inner surface and the outer surface. The plurality of microchannels are fluidly connected to the plurality of passages, and are configured to flow a cooling medium therethrough, cooling the combustor liner.

42 ENGINEERING↗

Dielectrokinetic chromatography and devices thereof

Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

47 OTHER INSTRUMENTATION↗

Dielectrokinetic chromatography devices

Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel MCP-Based Electron Source Studies

Microchannel plates (MCPs) were recently proposed as novel type of cathodes for electron guns [1], suitable for applications in design of electron lenses. We report results of the first systematic study of microchannel plate based photomultiplier time response and maximum cur-rent density tests using different sources of light pulses. The Burle 85011-501 MCP-PMT is found to have good time response properties being capable of producing na-nosecond long pulses with modest maximum current density and performance strongly dependent on magnetic field strength.

Haughey, M.↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

Heimann, Philip↗

Systems and methods for in-situ formation of nanoparticles and nanofins

Systems and methods for forming nanoparticles in-situ are disclosed herein. The nanoparticles may be formed in-situ through thermocycling a solution comprising at least one of a molten salt, a surfactant, and a catalyst. The nanoparticles may form in the solution itself and/or on surfaces of a vessel in which the solution is formed. Nanofins may be formed from the agglomeration of particles in the solution and on surfaces. Microchannels may be formed by these nanofins, and in some cases microchannels on a surface may have nanofins form on the surface. In some embodiments, a previously formed solution that has nanoparticles formed in-situ may be used to generate nanofins in a vessel, on a wafer in a vessel, in the solution itself, or combinations thereof.

Banerjee, Debjyoti↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes two highly adsorptive structures positioned to receive thermal energy from a thermal energy source, each highly adsorptive structure includes a substrate and a metal-organic framework (MOF) coupled to the respective substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions. The adsorptive cooling system includes a cooling unit and a circulation system adapted for circulating the refrigerant from one of the highly adsorptive structures to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to the same or other highly adsorptive structure. Each substrate may include a plurality of microchannels, providing ingress and egress paths for a refrigerant, defined by grooves in a surface of the substrate nearest the MOF and/or surfaces of a plurality of microcapillaries of the substrate. The microchannels provide ingress and egress paths for a refrigerant.

Baumann, Theodore F.↗

Additively featured plates for heat exchangers

Hybrid additive featured plates used to form an overall microchannel heat exchanger and corresponding method of manufacture are disclosed. Various additive manufacturing (AM) techniques may be used to form walls defining microchannel features on a plate substrate. The manufacturing method is a hybrid process in that leverages both additive and conventional manufacturing techniques to minimize both cost and fabrication time.

Carlson, Matthew David↗

Multimodal imaging of oil-in-water bilgewater emulsion and biofilms

Bilgewater emulsions, consisting of oil and surfactant mixtures in water, affect many aquatic species. Thus development of methods and techniques to treat or mitigate the formation and undesired consequences of shipboard emulsions are urgently needed. This work presents new results of the evolution of the bilgewaer chemical and physical properties using in situ imaging. A Navy O/W emulsion consisting of three oils and a detergent mixture was used as the synthetic bilgewater model [1, 2]. Synthetic oil-in-water (O/W) emulsion droplets were seled in a vacuum compatible microfluidic sample holder and imaged using a suite of tools including scanning electron microscopy (SEM), time-of-flight secondary ion mass spectrometry (ToF-SIMS), confocal laser scanning microscopy, and optical microscopy, highlighting the advantage of multiscale analysis and its applications in waste reduction and treatment in the environment. The transferrable and vacuum compatible microfluidic interface, System for Analysis at the Liquid Vacuum Interface (SALVI), was used in this study. SALVI enabled surface analysis of liquids and liquid-solid interactions using ToF-SIMS and SEM [3, 4]. Its detection window is an aperture of 2 ?m in diameter open to vacuum, permitting direct detection of the liquid surface. Liquid is withheld by surface tension within the aperture. The interface is composed of a silicon nitride membrane and polydimethylsiloxane microchannel [3, 4]. A variety of samples including complex liquid mixtures, ionic liquids, single mammalian cells, live biofilms, and solid-electrolyte interface have been analyzed using in situ imaging [5, 6]. The feasibility of using SALVI for in situ SEM imaging of nanoparticles and colloids in liquid was recently demonstrated [7]. This paper shows new findings of multimodal imaging and analysis of synthesized emulsion particles in water. Figure 1 depicts a schematic of multimodal in situ imaging of bilgewater emulsion using SEM and ToF-SIMS. Furthermore, we study the interactions of microbes and bilgewater emulsion. Microbes play an important role in the ocean. We hypothesize that microbes release organics that can act as surfactants that affect bilgewater formation or weakening. We present the first systematic study of emulsions and biofilms and investigate the effects of biofilms on bilgewater emulsions. Pseudomonas was selected as a model strain. Biofilms were cultured in a microchannel to allow culture [8]. Once a thick layer of biofilms was formed, the medium solution was changed to a mixture consisting of 50 % bilgewater emulsion. Dispersed biofilms were collected at 24 hrs. and 48 hrs. after emulsions were introduced into the channel. Bilgewater emulsions, biofilms, and mixtures of bilgewater emulsions and biofilms were analyzed using multiple in situ and ex situ techniques as described earlier. Our findings indicate that biofilms change the chemical makeup of the emulsion surface compositions and emulsion droplet size distribution, confirming the hypothesis that extracellular polymeric substance (EPS) related components released from biofilms can function as surfactants and change the oil-in-water interfaces.

bilgewater, multimodal imaging, biofilms↗

Dialysis on microchips using thin porous polymer membranes

Laser-induced phase-separation polymerization of a porous acrylate polymer is used for in-situ fabrication of dialysis membranes inside glass microchannels. A shaped 355 nm laser beam is used to produce a porous polymer membrane with a thickness of about 15 .mu.m, which bonds to the glass microchannel and form a semi-permeable membrane. Differential permeation through a membrane formed with pentaerythritol triacrylate was observed and quantified by comparing the response of the membrane to fluorescein and fluorescently tagging 200 nm latex microspheres. Differential permeation was observed and quantified by comparing the response to rhodamine 560 and lactalbumin protein in a membrane formed with SPE-methylene bisacrylamide. The porous membranes illustrate the capability for the present technique to integrate sample cleanup into chip-based analysis systems.

36 MATERIALS SCIENCE↗