Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

LISA Technology Development and Risk Reduction at NASA

The Laser Interferometer Space Antenna (LISA) is a joint ESA-NASA project to design, build and operate a space-based gravitational wave detector based on a laser interferometer. LISA relies on several technologies that are either new to spaceflight or must perform at levels not previously demonstrated in a spaceflight environment. The ESA-led LISA Pathfinder mission is the main effort to demonstrate LISA technology. NASA also supports complementary ground-based technology development and risk reduction activities. This presentation will report the status of NASA work on micronewton thrusters, the telescope, the optical pointing subsystem and mission formulation. More details on some of these topics will be given in posters. Other talks and posters will describe NASA-supported work on the laser subsystem, the phasemeter, and aspects of the interferometry. Two flight-qualified clusters of four colloid micronewton thrusters, each capable of thrust Levels between 5 and 30 microNewton with a resolution less than 0.l microNewton and a thrust noise less than 0.1 microNewton/vHz (0.001 to 4 Hz), have been integrated onto the LISA Pathfinder spacecraft. The complementary ground-based development focuses on lifetime demonstration. Laboratory verification of failure models and accelerated life tests are just getting started. LISA needs a 40 cm diameter, afocal telescope for beam expansion/reduction that maintains an optical pathlength stability of approximately 1 pm/vHz in an extremely stable thermal environment. A mechanical prototype of a silicon carbide primary-secondary structure has been fabricated for stability testing. Two optical assemblies must point at different distant spacecraft with nanoradian accuracy over approximately 1 degree annual variation in the angle between the distant spacecraft. A candidate piezo-inchworm actuator is being tested in a suitable testbed. In addition to technology development, NASA has carried out several studies in support of the mission formulation. The results of systems engineering work on flight software, avionics and reliability will be summarized.

Stebbins, Robin T.↗

Angular navigation on short baselines using phase delay interferometry

Results are presented for two recent short baseline experiments, with baseline lengths of 6 and 253 km, showing delay residuals of 10 ps or less for angularly close sources. On the 6-km baseline, a fiber-optic link was used to distribute a common frequency reference, enabling coherent operation of the two stations. The observed delay residuals correspond to a differential angular accuracy of about 10 nrad on the 253-km baseline. Future plans are discussed, including the development of a realtime correlation capability on a 22-km baseline at Goldstone, CA.

Edwards, Charles D.↗

Error Modeling of Multibaseline Optical Truss: Part 1: Modeling of System Level Performance

Global astrometry is the measurement of stellar positions and motions. These are typically characterized by five parameters, including two position parameters, two proper motion parameters, and parallax. The Space Interferometry Mission (SIM) will derive these parameters for a grid of approximately 1300 stars covering the celestial sphere to an accuracy of approximately 4uas, representing a two orders of magnitude improvement over the most precise current star catalogues. Narrow angle astrometry will be performed to a 1uas accuracy. A wealth of scientific information will be obtained from these accurate measurements encompassing many aspects of both galactic (and extragalactic science. SIM will be subject to a number of instrument errors that can potentially degrade performance. Many of these errors are systematic in that they are relatively static and repeatable with respect to the time frame and direction of the observation. This paper and its companion define the modeling of the, contributing factors to these errors and the analysis of how they impact SIM's ability to perform astrometric science.

meterology modeling↗

Combined single-pulse holography and time-resolved laser schlieren for flow visualization

A pulsed ruby laser and continuous-wave argon ion laser were used in a combined setup at the Langley Expansion Tube for single pulse holography and time resolved laser schlieren with a common optical axis. The systems can be operated simultaneously for a single run. For a single frame, the pulsed holographic setup offers the options of shadowgraph, Schlieren, and interferometry from the reconstructed hologram as well as the advantage of post-run sensitivity adjustments. For flow establishment studies the time resolved laser Schlieren provides visualization of the flow field every 12.5 microns for up to 80 frames with an exposure time per frame of 5.4 microns.

Burner, A. W.↗

Separation processes during binary monotectic alloy production

Observation of microgravity solidification processes indicates that outside of sedimentation, at least two other important effects can separate the phases: critical-point wetting and spreading; and thermal migration of second-phase droplets due to interfacial tension gradients. It is difficult to study these surface tension effects while in a unit gravity field. In order to investigate the processes occurring over a temperature range, i.e., between a consolute point and the monotectic temperature, it is necessary to use a low-gravity environment. The MSFC drop tube (and tower), the ballistic trajectory KC-135 airplane, and the Space Shuttle are ideal facilities to aid formation and testing of hypotheses. Much of the early work in this area focuses on transparent materials so that process dynamics may be studied by optical techniques such as photography for viewing macro-processes; holography for studying diffusional growth; spinodal decomposition and coalescence; ellipsometry for surface wetting and spreading effects; and interferometry and spectroscopy for small-scale spatial resolution of concentration profiles.

Frazier, D. O.↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

NASA Tech Briefs, November 2008

Topics covered include: Digital Phase Meter for a Laser Heterodyne Interferometer; Vision System Measures Motions of Robot and External Objects; Advanced Precipitation Radar Antenna to Measure Rainfall From Space; Wide-Band Radar for Measuring Thickness of Sea Ice; Vertical Isolation for Photodiodes in CMOS Imagers; Wide-Band Microwave Receivers Using Photonic Processing; L-Band Transmit/Receive Module for Phase-Stable Array Antennas; Microwave Power Combiner/Switch Utilizing a Faraday Rotator; Compact Low-Loss Planar Magic-T; Using Pipelined XNOR Logic to Reduce SEU Risks in State Machines; Quasi-Optical Transmission Line for 94-GHz Radar; Next Generation Flight Controller Trainer System; Converting from DDOR SASF to APF; Converting from CVF to AAF; Documenting AUTOGEN and APGEN Model Files; Sequence History Update Tool; Extraction and Analysis of Display Data; MRO DKF Post-Processing Tool; Rig Diagnostic Tools; MRO Sequence Checking Tool; Science Activity Planner for the MER Mission; UAVSAR Flight-Planning System; Templates for Deposition of Microscopic Pointed Structures; Adjustable Membrane Mirrors Incorporating G-Elastomers; Hall-Effect Thruster Utilizing Bismuth as Propellant; High-Temperature Crystal-Growth Cartridge Tubes Made by VPS; Quench Crucibles Reinforced with Metal; Deep-Sea Hydrothermal-Vent Sampler; Mars Rocket Propulsion System; Two-Stage Passive Vibration Isolator; Improved Thermal Design of a Compression Mold; Enhanced Pseudo-Waypoint Guidance for Spacecraft Maneuvers; Altimetry Using GPS-Reflection/Occultation Interferometry; Thermally Driven Josephson Effect; Perturbation Effects on a Supercritical C7H16/N2 Mixing Layer; Gold Nanoparticle Labels Amplify Ellipsometric Signals; Phase Matching of Diverse Modes in a WGM Resonator; WGM Resonators for Terahertz-to-Optical Frequency Conversion; Determining Concentration of Nanoparticles from Ellipsometry; Microwave-to-Optical Conversion in WGM Resonators; Four-Pass Coupler for Laser-Diode-Pumped Solid-State Laser; Low-Resolution Raman-Spectroscopy Combustion Thermometry; Temperature Sensors Based on WGM Optical Resonators; Varying the Divergence of Multiple Parallel Laser Beams; Efficient Algorithm for Rectangular Spiral Search; Algorithm-Based Fault Tolerance Integrated with Replication; Targeting and Localization for Mars Rover Operations; Terrain-Adaptive Navigation Architecture; Self-Adjusting Hash Tables for Embedded Flight Applications; Schema for Spacecraft-Command Dictionary; Combined GMSK Communications and PN Ranging; System-Level Integration of Mass Memory; Network-Attached Solid-State Recorder Architecture; Method of Cross-Linking Aerogels Using a One-Pot Reaction Scheme; An Efficient Reachability Analysis Algorithm.

Source record↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Microdynamic Behavior of a Joint Dominated Structure On-Orbit

The interferometry program experiments (IPEX) I and II are the first free-flying space experiments specifically designed to characterize the sub-micron microdynamic behavior of large flexible optical structures subjected to on-orbit thermal-mechanical disturbances.

flight↗

On-Orbit Microdynamic Behavior of a Flexible Structure: IPEX II

The Interferometry Program EXperiments (IPEX) I and II are the first free-flying space experiments specifically designed to characterize the sub-micron microdynamic behavior of large flexible optical structures subjected to on-orbit thermal-mechanical disturbances.

Microdynamic↗

EPR experiment and 2-photon interferometry: Report of a 2-photon interference experiment

After a very brief review of the historical Einstein, Podolsky, and Rosen (EPR) experiments, a new two-photon interference type EPR experiment is reported. A two-photon state was generated by optical parametric down conversion. Pairs of light quanta with degenerate frequency but divergent directions of propagation were sent to two independent Michelson interferometers. First and second order interference effectors were studied. Different than other reports, we observed that the second order interference visibility vanished when the optical path difference of the interferometers were much less than the coherence length of the pumping laser beam. However, we also observed that the second order interference behaved differently depending on whether the interferometers were set at equal or different optical path differences.

Shih, Y. H.↗

Holographic nondestructive tests performed on composite samples of ceramic-epoxy-fiberglass sandwich structure

When a hologram storing more than one wave is illuminated with coherent light, the reconstructed wave fronts interfere with each other or with any other phase-related wave front derived from the illuminating source. This multiple wave front comparison is called holographic interferometry, and its application is called holographic nondestructive testing (HNDT). The theoretical aspects of HNDT techniques and the sensitivity of the holographic system to the geometrical placement of the optical components are briefly discussed. A unique HNDT system which is mobile and possesses variable sensitivity to stress amplitude is discribed, the experimental evidence of the application of this system to the testing of the hidden debonds in a ceramic-epoxy-fiberglass structure used for sample testing of the radome of the Pershing missile system is presented.

Kurtz, R. L.↗

From Monolithics to Tethers to Freeflyers: The Spectrum of Large Aperture Sensing from Space

As part of NASA's endeavor to push the envelope and go where we have never been before, the Space Science Enterprise has laid out a vision which includes several missions that revolutionize the collection of scientific data from space. Many of the missions designed to meet the objectives of these programs depend heavily on the ability to perform space-based interferometry, which has recently become a rapidly growing field of investigation for both the scientific and engineering communities. While scientists are faced with the challenges of designing high fidelity optical systems capable of making detailed observations, engineers wrestle with the problem of providing s-pace-based platforms that can permit this data gathering to occur. Observational data gathering is desired at's variety of spectral wavelengths and resolutions, calling for interferometers with a range of baseline requirements. Approaches to configuration design are as varied as the missions themselves from large monolithic spacecraft to multiple free-flying small spacecraft and everything in between. As will be discussed, no one approach provides a 'panacea' of solutions rather each has its place in terms of the mission requirements. The purpose here is to identify the advantages and disadvantages of the various approaches, to discuss the driving factors in design selection and determine the relative range of applicability of each design approach.

Leitner, Jesse↗