Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIO INTERFERENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Vacuum compatible sample positioning device for matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry imaging

The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in {approx}1 x 10{sup -8} mbar vacuum. The range of motion is set to 100 mm x 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption/ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The ''oversampling'' MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalized Theory and Realization of Continuously Loss-Programmable Bandpass Filtering Attenuators

With the increased demand for modern wireless systems in various applications, the need for adjustable radio frequency (RF) systems has dramatically increased. These modern systems rely on operating in the microwave frequency spectrum (1 GHz to 1 THz) without interference from other devices while also retaining the ability to detect very low and very high power signals simultaneously. There is also an ever-increasing demand for reducing the cost, size, weight, and power (C-SWaP) of these modern RF systems, driving the demand for more agile filters in the microwave frequency spectrum. In this paper, a generalized theory of bandpass filtering attenuators (filtenuators) is proposed. A filtenuator is a device that combines the frequency- selective characteristics of a filter and the loss-programmable characteristics of an attenuator into a single component. The loss- programmable aspect of the filtenuator is based on the tuning of a π-network of resistances, which are implemented using PIN diodes to control the individual resistance values electronically. A loss-programmable, third-order Chebyshev bandpass filtenuator is designed, fabricated, and measured to verify the generalized theory. The filtenuator is designed to operate at 1 GHz and have a tunable attenuation range of 2-10 dB. This proposed filtenuator demonstrates the feasibility of a tunable, low C-SWaP solution to increase RF system dynamic range and a design process that allows for future development of filtenuators.

42 ENGINEERING↗

136 MHz interferometer error due to galactic nucleus.

Extraneous interfering signals are discussed which limit the basic accuracy of the 136 MHz Minitrack radio-interferometer system providing electrical phase data from which direction cosines for determining spacecraft orbits are generated. In particular, the fundamental error due to interference caused by the passage of the galactic nucleus is investigated. An expression is developed for the lower bound of the phase error when the noise source is not uniformly distributed across the Minitrack's zenith-pointed fan beam. In addition, the threshold of the Minitrack input power levels is determined below which the electrical phase is no longer determined unambiguously. The effect of the passage of the galactic nucleus coincident with the presence of a spacecraft is analyzed, and the corresponding phase error established.

Kyriakopoulos, N.↗

Geophysical subsurface probing with radio-frequency interferometry

The radio-frequency interferometry method can be used to probe interiors of celestial bodies and terrestrial areas with low conductivity. In order to interpret the interference patterns, a theoretical study is made of the electromagnetic fields due to a dipole antenna on the surface of a horizontally stratified n-layered medium. Three approaches are used to calculate the interference patterns: direct numerical integration, asymptotic evaluation by the saddle point method, and a residue series approach. The asymptotic approach leads to the geometrical-optics interpretation. The residue approach leads to modal analysis. The validity of the formulation is checked by comparisons with analog model tank experiments and actual field data obtained from glaciers.

Kong, J. A.↗

The impact of WARC '79 on space applications and research

Prior to the 1979 World Administrative Radio Conference (WARC), no frequency bands were allocated for remote sensing measurements. Actions taken by the WARC insure that frequencies will be available for such use, and that operations can be conducted without harmful interference on a worldwide basis for the benefit of all nations. New global allocations for Space Research will permit worldwide acquisition of research data via relay satellites. Wideband allocations for deep-space research will allow more accurate position determination of deep-space probes and transmission of higher resolution data. The WARC had an impact on a number of other applications and research areas such as: meteorological satellites, land-mobile satellites, search and rescue systems, solar power satellites, standard-frequency satellites, radio astronomy and the search for extraterrestrial intelligence. The actions taken at the WARC affecting these services and applications will be described in the paper.

Kiebler, J. W.↗

Alternate current magnetic property characterization of nonstoichiometric zinc ferrite nanocrystals for inductor fabrication via a solution based process

We investigate the ac magnetic behavior of solution processable, non-stoichiometric zinc ferrite nanocrystals with a series of sizes and zinc concentrations. Nearly monodisperse Zn{sub x}Fe{sub 3−x}O{sub 4} nanocrystals (x = 0–0.25) with an average size ranging from 7.4 nm to 13.8 nm are synthesized by using a solvothermal method. All the nanocrystals are in a superparamagnetic state at 300 K, which is confirmed by Superconductive Quantum Interference Device magnetometry. Due to the doping of non-magnetic Zn{sup 2+} into A site of ferrite, the saturation magnetization of nanocrystals increases as the size and Zn concentration increases. The ac magnetic permeability measurements at radio frequencies reveal that the real part of the magnetic permeability of similarly sized ferrite nanocrystals can be enhanced by almost twofold as the Zn{sup 2+} doping level increases from 0 to 0.25. The integration of 12.3 nm Zn{sub 0.25}Fe{sub 2.75}O{sub 4} nanocrystals into a toroidal inductor and a solenoid inductor prepared via a simple solution cast process yields a higher quality factors than air core inductors with the same geometries up to 5 MHz and 9 MHz, respectively, which is in the regime of the switching frequencies for the advanced integrated power converters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of antenna polar diagrams and efficiencies using a phase-switched interferometer

It is desirable to know antenna polar patterns and efficiencies accurately. In the past, calibration measurements have been made using balloons and aircraft and more recently satellites. These techniques are usually very expensive. It is shown that under certain circumstances it is possible to use a simpler and inexpensive technique by connecting together the antenna under test with another antenna to form a phase switched interferometer as first described by Ryle (1952). The technique does require a suitable radio source which gives measurable powers when using small antennas and since dipoles have broad patterns, radio sources with similar right ascensions but different declinations to the primary source can be a problem. These problems can partly be overcome by filtering the interference pattern.

Vincent, R. A.↗

Reducing Field Distortion in Magnetic Resonance Imaging

A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

Eom, Byeong Ho↗

Scheduled Sequential Compressed Spectrum Sensing for Wideband Cognitive Radios

The support for high data rate applications with the cognitive radio technology necessitates wideband spectrum sensing. However, it is costly to apply long-term wideband sensing and is especially difficult in the presence of uncertainty, such as high noise, interference, outliers, and channel fading. In this paper, we propose scheduling of sequential compressed spectrum sensing which jointly exploits compressed sensing (CS) and sequential periodic detection techniques to achieve more accurate and timely wideband sensing. Instead of invoking CS to reconstruct the signal in each period, our proposed scheme performs backward grouped-compressed-data sequential probability ratio test (backward GCD-SPRT) using compressed data samples in sequential detection, while CS recovery is only pursued when needed. This method on one hand significantly reduces the CS recovery overhead, and on the other takes advantage of sequential detection to improve the sensing quality. Furthermore, we propose (a) an in-depth sensing scheme to accelerate sensing decision-making when a change in channel status is suspected, (b) a block-sparse CS reconstruction algorithm to exploit the block sparsity properties of wide spectrum, and (c) a set of schemes to fuse results from the recovered spectrum signals to further improve the overall sensing accuracy. Finally, extensive performance evaluation results show that our proposed schemes can significantly outperform peer schemes under sufficiently low SNR settings.

42 ENGINEERING↗

MILLISECOND IMAGING OF RADIO TRANSIENTS WITH THE POCKET CORRELATOR

We demonstrate a signal-processing concept for imaging the sky at millisecond rates with radio interferometers. The 'Pocket Correlator' (PoCo) correlates the signals from multiple elements of a radio interferometer fast enough to image brief, dispersed pulses. By the nature of interferometry, a millisecond correlator functions like a large, single-dish telescope, but with improved survey speed, spatial localization, calibration, and interference rejection. To test the concept, we installed PoCo at the Allen Telescope Array (ATA) to search for dispersed pulses from the Crab pulsar, B0329+54, and M31 using total-power, visibility-based, and image-plane techniques. In 1.7 hr of observing, PoCo detected 191 giant pulses from the Crab pulsar brighter than a typical 5{sigma} sensitivity limit of 60 Jy over pulse widths of 3 ms. Roughly 40% of pulses from pulsar B0329+54 were detected by using novel visibility-based techniques. Observations of M31 constrain the rate of pulses brighter than 190 Jy in a three-degree region surrounding the galaxy to <4.3 hr{sup -1}. We calculate the computational demand of various visibility-based pulse search algorithms and demonstrate how compute clusters can help meet this demand. Larger implementations of the fast imaging concept will conduct blind searches for millisecond pulses in our Galaxy and beyond, providing a valuable probe of the interstellar/intergalactic media, discovering new kinds of radio transients, and localizing them to constrain models of their origin.

79 ASTRONOMY AND ASTROPHYSICS↗

System to Perform Radio Frequency Interferometry Using Optical Fiber Sensing Signal Processing Techniques

Aspects of the present disclosure involve a system and method for performing radio frequency interferometry using optical fiber sensing. Optical fiber sensing is performed as a reference signal is defined and compared, in the optical domain, to incoming signals to obtain interference fringe patterns that can be used to decode phase shift offsets with respect to the designated reference signal. The phase shift offsets can be determined by first optically modulating the reference and incoming signals using a laser source as the carrier. In the optical domain, the reference and incoming signals are combined using an optical coupler and then converted back to the electrical domain for processing.

Ott, Melanie N.↗

Discrete magic angle turning system, apparatus, and process for in situ magnetic resonance spectroscopy and imaging

Described are a "Discrete Magic Angle Turning" (DMAT) system, devices, and processes that combine advantages of both magic angle turning (MAT) and magic angle hopping (MAH) suitable, e.g., for in situ magnetic resonance spectroscopy and/or imaging. In an exemplary system, device, and process, samples are rotated in a clockwise direction followed by an anticlockwise direction of exactly the same amount. Rotation proceeds through an angle that is typically greater than about 240 degrees but less than or equal to about 360 degrees at constant speed for a time applicable to the evolution dimension. Back and forth rotation can be synchronized and repeated with a special radio frequency (RF) pulse sequence to produce an isotropic-anisotropic shift 2D correlation spectrum. The design permits tubes to be inserted into the sample container without introducing plumbing interferences, further allowing control over such conditions as temperature, pressure, flow conditions, and feed compositions, thus permitting true in-situ investigations to be carried out.

47 OTHER INSTRUMENTATION↗

Modelling an electro-optical modulator based on a vertical p – n junction in a silicon-on-insulator structure

We report the results of numerical simulation of a Mach – Zehnder electro-optical modulator using beam splitters based on multimode interference in a silicon-on-insulator structure. The control is provided due to the depletion effect in the vertical p – n junction, which can be fabricated using the self-alignment technology. An optimal modulator design is proposed, which impedance is matched with an external 50-Ω load, for which, with a reverse bias of – 5 V and an active length of 1.7 mm, the optical frequency bandwidth of ∼ 50 GHz can be achieved. A special doping profile of the p – n junction of the modulator is presented, which provides an optical frequency bandwidth of 30 GHz with a reverse bias of –3 V and a modulator length of 2.5 mm. Such modulators can be used in integrated optics, optical communications and radio photonics devices. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Methodology for Conducting Hall Thruster EMI Tests in Metal Vacuum Chambers of Arbitrary Shape and Size

While the closed-drift Hall thruster (CDT) offers significant improvement in performance over conventional chemical rockets and other advanced propulsion systems such as the arcjet, its potential impact on spacecraft communication signals must be carefully assessed before widespread use of this device can take place. To this end, many of the potentially unique issues that are associated with these thrusters center on its plume plasma characteristics and the its interaction with electromagnetic waves. Although a great deal of experiments have been made in characterizing the electromagnetic interference (EMI) potential of these thrusters, the interpretation of the resulting data is difficult because most of these measurements have been made in vacuum chambers with metal walls which reflect radio waves emanating from the thruster. This project developed a means of assessing the impact of metal vacuum chambers of arbitrary size or shape on EMI experiments, thereby allowing for test results to be interpreted properly. Chamber calibration techniques were developed and initially tested at RIAME using their vacuum chamber. Calibration experiments were to have been made at Tank 5 of NASA GRC and the 6 m by 9 m vacuum chamber at the University of Michigan to test the new procedure, however the subcontract to RIAME was cancelled by NASA memorandum on Feb. 26. 1999.

Gallimore, Alec D.↗

Design and Characterization of the Engineering Model of the Spectrometer Onboard LuSEE-Night

The Lunar Surface Electromagnetics Explorer - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio quiet farside of the Moon. The LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA's Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5−50MHz band. The engineering model (EM) of the four-channel spectrometer has been developed. The EM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the EM meets all the requirements for LuSEE-Night. Three mitigation techniques have been implemented and verified to suppress self-induced electromagnetic interference (EMI). The flight model of the spectrometer is currently being developed and is scheduled to be shipped to the integration site in early 2024

47 OTHER INSTRUMENTATION↗