Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗

Investigation of magnetic noise from conductive shields in the 10–300 kHz frequency range

Here we present experimental and theoretical investigations of magnetic noise originating from radio-frequency (RF) conductive shields of flat geometry in the inductance-dominated impedance regime below 300 kHz. The measurement is based on a Q-factor determination of a coil that provides a sufficient sensitivity, placed at the position where the shield magnetic noise is measured. The theory is based on calculations of magnetic field and inductance of one or a few flat rings that emulate a conductive shield. The theoretical model is found to be in close agreement with experimental data. It can be used to predict the magnetic noise of a conductive shield with different thicknesses, conductivities, and temperatures at different distances for a wide range of frequencies. Although the model can be generalized for a more arbitrary shield geometry, in its presented form, it can be applied to the magnetic noise predictions when the shield surface curvature is not large. One important conclusion is that the RF conductive shield can generate the magnetic noise much lower than femtotesla, and, thus, it can be used in many precision experiments targeting minute high-frequency magnetic signals, such as detection of magnetic resonance imaging and nuclear quadrupole resonance signals and search for axion dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal evaluation method for Klystron RF power

The feasibility of adding instrumentation to the cooling system of a microwave transmitter for use as a calorimetric power measurement calibration is examined. It considers the accuracy of the basic measurements as well as heat sources and losses not measured. Experimental results are presented in support of the theory.

Conroy, B. L.↗

Effect of reactor loading on atomic oxygen concentration as measured by NO chemiluminescence

It has previously been observed that the etch rate of polyethylene samples in the afterglow of an RF discharge in oxygen increases with reactor loading. This enhancement of the etch rate is attributed to reactive gas phase products of the polymer etching. In the present work, emission spectroscopy is employed to examine the species present in the gas phase during etching of polyethylene. In particular, the concentration of atomic oxygen downstream from the polyethylene samples is studied as a function of the reactor loading. It is found that the concentration of atomic oxygen increases as the reactor loading is increased. The increase of etch rate with increased reactor loading is attributed to the increase of atomic oxygen concentration in the vicinity of the sample.

Lerner, N. R.↗

Machine learning-aided line intensity ratio technique applied to deuterium plasmas

It has been demonstrated that the electron density, n e , and temperature, T e , are successfully evaluated from He I line intensity ratios coupled with machine learning (ML). In this paper, the ML-aided line intensity ratio technique is applied to deuterium (D) plasmas with 0.031 < n e (10 18 m –3 ) < 0.67 and 2.3 < T e (eV) < 5.1 in the PISCES-A linear plasma device. Two line intensity ratios, D α /D γ and D α /D β , are used to develop a predictive model for n e and T e separately. Reasonable agreement of both ne and Te with those from single Langmuir probe measurements is obtained at n e > 0.1 × 10 18 m –3 . Addition of the D 2 /D α intensity ratio, where the D 2 band emission intensity is integrated in a wavelength range of λ ~ 557.4–643.0 nm, is found to improve the prediction of, in particular, n e , and T e . It is also confirmed that the technique works for D plasmas with 0.067 < n e (10 18 m –3 ) < 6.1 and 0.8 < T e (eV) < 15 in another linear plasma device, PISCES-RF. The two training datasets from PISCES-A and PISCES-RF are combined, and unified predictive models for n e and T e give reasonable agreement with probe measurements in both devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Combined Beacon Receiver and Digital Radiometer for 40 GHz Propagation Measurements at the Madrid Deep Space Communications Complex

NASA Glenn Research Center (GRC) and the Jet Propulsion Laboratory (JPL) have jointly developed an atmospheric propagation terminal to measure and characterize propagation phenomena at 40 GHz at the Madrid Deep Space Communications Complex (MDSCC) in Robledo de Chavela, Spain. The hybrid Q-band system combines a 40 GHz beacon receiver and digital radiometer into the same RF front-end and observes the 39.402 GHz beacon of the European Space Agencys Alphasat Aldo Paraboni TDP5 experiment. The goals of these measurements are to assist MDSCC mission operations as well as to contribute to the development and improvement of International Telecommunications Union (ITU) models for prediction of communications systems performance within the Q-band. Herein, we provide an overview of the system design, characterization, and plan of operations to commence at the MDSCC beginning in March 2017.

Radio Attenuation↗

Design Considerations for Controlling Silicon Nanoparticle Nucleation and Growth in a Nonthermal Plasma

Controlling the nucleation and growth of nanoparticles in low temperature plasma systems is imperative for controlling nanoparticle size distributions; and for some applications such as deposition and etching in microelectronic processing, preventing particle contamination. In this work, silicon nanoparticle (NP) production from silane is used as a model system to investigate the nucleation process. Although the mechanisms responsible for silicon NP nucleation and growth have been studied, it is unclear how controllable system parameters (e.g., pressure, system geometry, and gas composition) can be used to inhibit or promote NP formation. For example, the transport of reactive silane species is expected to significantly affect the feed fraction of silane required to nucleate silicon NP (the nucleation onset fraction) due to losses at the reactor walls. In this work, NP mass density was determined as a function of system pressure, gas composition, and reactor diameter for a tubular flow-through radiofrequency (RF) plasma using Ar/H2/He/SiH4 gas mixtures. A quartz crystal microbalance (QCM) impactor was developed to measure the total aerosol mass density downstream of the plasma and thereby identify the nucleation onset and its dependence on process parameters. Finally, a reaction mechanism was developed and incorporated into a global plasma chemistry model to better understand the nucleation onset and NP growth.

36 MATERIALS SCIENCE↗

NO formation by N 2 /O 2 plasma catalysis: The impact of surface reactions, gas-phase reactions, and mass transport

Pathways and timescales relevant to facilitate plasma-assisted N 2 -O 2 reactions are assessed by measuring the consumption of plasma-derived N and the formation of NO in the gas phase and over Ag catalytic surfaces. These measurements are enabled by a setup that enables N 2 activation in an atmospheric pressure RF plasma jet, enables O 2 addition in the plasma afterglow, facilitates reactions over an Ag wire catalyst, and allows species density quantification by molecular beam mass spectrometry. Gas-phase reactions consume N but do not form NO with high selectivity. The presence of the non-porous Ag wire catalyst increases the rate of N conversion to NO, though mass transfer processes, not surface reactions, dictate the rate of N consumption. When O 2 concentrations and the ratio of the surface area of the catalyst to the void volume of the reactor are high (3–5 mol% O 2 , 10900 m –1 ), N conversion to NO reaches 100 % selectivity. When both N 2 and O 2 are fed through the plasma jet, gas-phase NO production increases 10×, although plasma and gas-phase processes do not exclusively produce NO. Above a threshold NO density, N cannot diffuse to the catalyst surface faster than it is consumed in the gas phase by reactions with NO. Furthermore, the use of heterogeneous catalysts to enhance plasma-driven N x O y formation and control N x O y product selectivity is limited to cases where diffusive transport of N from the gas phase to the catalyst surface is faster than consumption of N from gas-phase reactions with NO.

Engineering↗

Frequency dependence of BCS and residual resistance using multi-mode measurement of nitrogen-doped single-cell elliptical cavities

Various cavity surface treatments have been found to significantly improve cavity quality factor, Q0, with one such treatment being nitrogen-doping (N-doping). N-doped 1.3 GHz cavities were the first found to exhibit anti-Q slope, the increase of Q0 with accelerating field, Eacc. However, even with the use of the same N-doping recipes, this anti-Q slope behavior has not been realized in sub-GHz frequency cavities. In this study, we measured the Q0 and surface resistance, RS, of our N-doped, single-cell, elliptical cavity for both the 644 MHz fundamental mode (FM) and 1.45 GHz higher-order mode (HOM). As a result of multi-mode measurements, the BCS and residual resistances, the temperature-dependent and temperature-in-dependent RF surface resistances, could be determined without the influence of cavity-to-cavity surface treatment variations. We will discuss the frequency-dependent behaviors of the BCS and residual resistances.

Accelerator Physics↗

Study of ponderomotive instability in the FRIB beta=0.53 half-wave resonator

Superconducting radio-frequency niobium cavities are susceptible to deformations caused by external or internal forces, leading to shifts in the cavity resonant frequency. One source of deformation comes from the radiation pressure of the cavity fields, producing the so-called Lorentz force detuning effect. This effect can couple to the cavity mechanical modes in generator driven mode, leading to ponderomotive instability. In the FRIB 322 MHz, β=0.53 Half-wave Resonators (HWR), the instability appeared when the cavity was detuned, with thresholds depending on low-level RF control parameters, such as closed loop gain, as well as accelerating gradient. Using a measured Lorentz Transfer Function, Simulink simulations were conducted to predict the instability thresholds, which were then compared with the experimental results. We will discuss how these thresholds can be broadened to enable stable operation at higher gradients.

Accelerator Physics↗

Parametric testing of an externally configured thermionic converter

A 25.4-cm long externally configured converter was performance tested by electrically heating the emitter to simulate reactor thermal power input. The measured maximum output power was limited by the maximum input power available from the electric RF induction heater. With maximum heater input power, the converter electric output was 178 W (1.95 W/sq cm) at an emitter temperature of 1946 K. This electric output power was smaller than expected. A reactor-core-length (25.4-cm long) cylindrical thermionic converter power and maintaining the emitter-to-collector gap without shorting are of major importance to the feasibility of a 25.4-cm-long reactor fuel element. The emitter of the converter is located externally to the collector to increase the fuel-volume fraction and to allow redundant collector cooling in a reactor configuration.

Shimada, K.↗

An active radar calibration target

An active radar calibrator (ARC), consisting of a receive antenna and a transmit antenna with an RF amplifier in between, is proposed as a tool for conducting high-precision calibration measurements of radar systems. The ARC can be designed to have a large radar cross-section with a broad pattern. Its major advantages over passive reflectors are its small physical size and its suitability for calibrating radars operating in a cross-polarized antenna configuration.

Brunfeldt, D. R.↗

Materials screening chamber for testing materials resistance to atomic oxygen

A unique test chamber for exposing material to a known flux of oxygen atoms is described. The capabilities and operating parameters of the apparatus include production of an oxygen atom flux in excess of 5 x 10 to the 16th atoms/sq cm-sec, controlled heating of the sample specimen, RF circuitry to contain the plasma within a small volume, and long exposure times. Flux measurement capabilities include a calorimetric probe and a light titration system. Accuracy and limitations of these techniques are discussed. An extension to the main chamber to allow simultaneous ultraviolet and atomic oxygen exposure is discussed. The oxygen atoms produced are at thermal energies. Sample specimens are maintained at any selected temperature between ambient and 200 C, to within + or - 2 C. A representative example of measurements made using the chamber is presented.

Pippin, H. G.↗

Linear ion trap based atomic frequency standard

In order to develop a trapped ion-based fieldable frequency standard with stability 1 x 10 to the -13th/sq rt tau for averaging times tau greater than 10,000 s, a hybrid RF/DC linear ion trap was developed which permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. The authors have confined Hg-199(+) ions in this trap and have measured very high Q transitions with good SNRs. In preliminary measurements they obtained stabilities of 1.6 x 10 to the -13th/sq rt tau (tau between 50 and 800 s) with a 160-mHz wide atomic resonance linewidth and a signal-to-noise ratio of 40 for each measurement cycle. Atomic resonance lines as narrow as 30 mHz on the 40.5-GHz clock transition have been measured with no appreciable reduction in the ion signal. A stability of 7 x 10 to the -14th/sq rt tau is made possible by the signal-to-noise and line Q of this measured transition. Analysis of fundamental sources of frequency instability indicates that a long-term stability of 2 x 10 to the -16th is feasible for this device with existing technology for tau = 10 to the 6th s or more.

Prestage, John D.↗

K- and Ka-band mobile-vehicular satellite-tracking reflector antenna system for the NASA ACTS mobile terminal

This paper describes the development of the K- and Ka-band mobile-vehicular satellite-tracking reflector antenna system for NASA's ACTS Mobile Terminal (AMT) project. ACTS is NASA's Advanced Communications Technology Satellites. The AMT project will make the first experimental use of ACTS soon after the satellite is operational, to demonstrate mobile communications via the satellite from a van on the road. The AMT antenna system consists of a mechanically steered small reflector antenna, using a shared aperture for both frequency bands and fitting under a radome of 23 cm diameter and 10 cm height, and a microprocessor controlled antenna controller that tracks the satellite as the vehicle moves about. The RF and mechanical characteristics of the antenna and the antenna tracking control system are discussed. Measurements of the antenna performance are presented.

Densmore, Art↗

RF Properties of Epitaxial Lift-Off HEMT Devices

Epitaxial layers containing GaAs HEMT and P-HEMT structures have been lifted-off the GaAs substrate and attached to other host substrates using an AlAs parting layer. The devices were on-wafer RF probed before and after the lift-off step showing no degradation in the measured S-parameters. The maximum stable gain indicates a low frequency enhancement of the gain of 1-2 dB with some devices showing an enhancement of F(sub max)F(sub T) consistently shows an increase of 12-20% for all lifted-off HEMT structures. Comparison of the Hall measurements and small signal models show that the gain is improved and this is most probably associated with an enhanced carrier concentration.

Young, Paul G.↗

Ultra-stable superconducting cavity maser oscillator

An ultra-stable superconducting triple cavity ruby maser oscillator (10) is obtained by providing the oscillator with a superconducting quantum interference device (SQUID) (50), which measures the magnetic field at the ruby (14) and compensates for changes by adjusting the RF pump signal amplitude (42), thereby attaining stabilities of about four orders of magnitude greater than presently attainable.

Strayer, Donald M.↗