Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

JPSS-2 VIIRS Polarization Sensitivity Performance Comparison with Heritage VIIRS Sensors

The Joint Polar Satellite System 2 (JPSS-2) is the follow-on for the Suomi-National Polar-orbiting Partnership (S-NPP) and Joint Polar Satellite System 1 (JPSS-1) missions. These spacecrafts provide critical weather and global climate products to the user community. A primary sensor on both JPSS and S-NPP is the Visible-Infrared Imaging Radiometer Suite (VIIRS) with Earth observations covering the Reflective Solar Band (RSB), Thermal Emissive Band (TEB) and Day Night Band (DNB) spectral regions. The VIIRS Sensor Data Records (SDRs) contain the calibrated Earth observations that are used in Environmental Data Record (EDR) products such as Ocean Color/Chlorophyll (OCC) and Sea Surface Temperature (SST). This SDR calibration is performed using unpolarized sources such as the Solar Diffuser (SD) for the RSBs and an On-Board Calibrator BlackBody (OBCBB) for the TEBs. Therefore, polarized Earth scenes will have radiometric bias errors within the SDRs based on how sensitive VIIRS is to polarized illumination and is corrected in some EDR algorithms. This paper will discuss the JPSS-2 VIIRS polarization characterization methodology, polarization sensitivity results and compare its performance to its predecessors S-NPP and JPSS-1 VIIRS. Optical modifications to the JPSS-2 VIIRS sensor to address heritage polarization sensitivity issues will be discussed.

S-NPP↗

Jpss-4 VIIRS Polarization Sensitivity Performance Comparison With Heritage VIIRS Sensors

The Joint Polar Satellite System 4 (JPSS-4) is the follow-on for the Suomi-National Polar-orbiting Partnership (S-NPP) and Joint Polar Satellite Systems 1-3 (JPSS-1, -2 and -3) missions. A primary sensor on both JPSS and S-NPP spacecrafts is the Visible-Infrared Imaging Radiometer Suite (VIIRS) that provides valuable weather and climate products to the user community. VIIRS covers the Reflective Solar Band (RSB) and Thermal Emissive Band (TEB) spectral regions and contains a Day Night Band (DNB) that uses Lunar illumination at night. VIIRS provides top-of-atmosphere radiance, reflectance, and brightness temperature within the Sensor Data Records (SDRs) that are used in sea surface temperature, cloud characterization, land surface properties and ocean color/chlorophyll Environmental Data Record (EDR) products. The SDR calibration is performed using unpolarized sources such as a Solar Diffuser (SD) for the RSBs or an On-Board Calibrator BlackBody (OBCBB) for the TEBs. Earth scenes with polarizing properties will create radiometric bias errors within the SDRs based on how sensitive VIIRS is to polarized illumination and must be corrected in some EDR algorithms. This paper will discuss the JPSS-4 VIIRS polarization characterization methodology, polarization sensitivity results and compare its performance to its predecessors S-NPP and JPSS-1 through -3 VIIRS.

David Moyer↗

Modeling the X-Ray Process, and X-Ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Khoshti, Ajay↗

Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Koshti, Ajay M.↗

Accuracy of High Explosive Data used for Reactive Burn Model Calibration

Reactive burn models for a high explosive (HE) have three components: an equation of state (EOS) for the products, an EOS for the reactants and a reaction rate. For the products, we discuss the uncertainty in data for the planar detonation state and its release isentrope. For the reactants, the uncertainty in the principal shock locus data is discussed. For the reaction rate, we discuss uncertainties in shock initiation data (distance-of-run to detonation as a function of shock pressure), and curvature effect data (detonation speed as a function of front curvature). An important source of uncertainty for calibrating the reaction rate for a plastic-bonded explosive (PBX) results from variations in heterogeneities; that is the mesoscale structure of HE grains, binder and porosity. This shows up in the scatter of both shock initiation data and curvature effect data with small changes in initial density and initial temperature, and systematic changes with PBX lot. As illustrative examples, we use data for the conventional HMX based PBX 9501 and the insensitive TATB based PBX 9502 since these explosives have been extensively studied and high quality data are readily available in the literature.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ expects to detect coherent neutrino-nucleus scattering of $^{8}$B solar neutrinos, the signal from which is very similar to a dark matter particle with mass of about 5.5 GeV/$c^{2}$, which result in typical nuclear recoil energies of $<$5 keV$_{\text{nr}}$. Therefore, it is of crucial importance to calibrate the response of recoiling xenon nuclei to keV-energy recoils. This analysis details the first in situ photoneutron calibration of the LZ detector and probes its response in this energy regime.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Photometric calibration of NGS/POSS and ESO/SRC plates using the NOAO PDS measuring engine. II - Surface photometry

In this paper we present a method to calibrate surface photometry of faint sources measured from direct photographic plates, such as those of the NGS/POSS and ESO/SRC Sky Survey. This calibration procedure does not require scanning sensitometer spots on the plates, but instead uses measurements of the brightness profiles of many faint stars of known brightness to fit a linearized approximation to the characteristic curve. The approximation is valid for only low- to medium-density emulsions, so this technique is appropriate only for relatively faint emission. Comparison between measurements of representative extended sources on the NGS/POSS and CCD images indicates that surface photometry can be obtained from the Sky Survey plates accurate to 0.1-0.3 mag in the range mu(B) between 23 and 27 and mu(R) between 22 and 26 mag/sq arcsec.

Cutri, Roc M.↗

Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

radiometry↗

Analysis and Integration of the Hydraulic Fracturing Test Site-2 (HFTS-2) Comprehensive Dataset

Hydraulic Fracturing Test Site-2 (HFTS-2) is a field-based research experiment performed in the Permian (Delaware) Basin. The unique aspect of this program was the acquisition of a unique, comprehensive, diagnostic dataset. Additionally, shorter parent wells drilled three years before the child wells offered clear distinction between the stages influenced by parent-child effects and the stages without any effects. The goal of this study was to analyze and integrate this comprehensive diagnostic dataset to understand the areal and vertical extent of hydraulic fractures (HF). The paper also provides insights on the effects of parent wells’ depletion on child well HF geometry based on various monitoring methods and subsurface models. Areal and vertical coverage for all HFTS-2 wells during stimulation and depletion was estimated based on analysis and interpretation of diagnostics and advanced modeling results. HFTS-2 diagnostics included microseismic (MS), pre- and post-stimulation logs and cores, bottomhole gauges, and fiber optic (FO) data. The diagnostics results (MS, FO, image logs) were integrated and used to calibrate subsurface models. Additional field tests were designed and implemented for depletion monitoring. The tailored program for monitoring depletion included vertical and slant well pressures, interference testing, and a vertical strain depletion trial. Areal Coverage: Conventional MS (and FO MS) were used to compute HF dimensions, which were compared with diagnostics (FO strain, gauge, image logs) observations and calibrated subsurface models. A post-production interference test did not show offset well communication. Vertical Coverage: Vertical coverage during stimulation was monitored using a vertical monitoring well. The stronger mechanical strain signals showed good correlation with MS event intensities, geomechanical properties, and gauge inferences. Vertical depletion was estimated based on vertical/slant well gauges and strain depletion tests. Parent-Child Effects: Diagnostics and calibrated subsurface models show asymmetry in child well fracture geometries for stages that overlap parent wells. Child well image logs serve as a good indicator for parent Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S031R004/2477423/urtec-2021-5241-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5241 well HF tracking. Child well MS events had an eastward bias, in line with pre-stimulation image logs, and was confirmed by parent well frac hits. Novel/Additive Information: The dataset presents a unique, over-constrained problem space to compare independent techniques to arrive at HF metrics (i.e., stimulation height and/or half-length), unlike a single source dataset, in which calibration is done using available data to guide predictions. Here, the asymmetry in HF geometry seen in the stages influenced by parent-child effects offers unique insights into well spacing and landing, which are key capital decisions the unconventional resources industry is seeking to optimize.

58 GEOSCIENCES↗

Earth Radiation Budget Experiment scanner radiometric calibration results

The Earth Radiation Budget Experiment (ERBE) scanning radiometers are producing measurements of the incoming solar, earth/atmosphere-reflected solar, and earth/atmosphere-emitted radiation fields with measurement precisions and absolute accuracies, approaching 1 percent. ERBE uses thermistor bolometers as the detection elements in the narrow-field-of-view scanning radiometers. The scanning radiometers can sense radiation in the shortwave, longwave, and total broadband spectral regions of 0.2 to 5.0, 5.0 to 50.0, and 0.2 to 50.0 micrometers, respectively. Detailed models of the radiometers' response functions were developed in order to design the most suitable calibration techniques. These models guided the design of in-flight calibration procedures as well as the development and characterization of a vacuum-calibration chamber and the blackbody source which provided the absolute basis upon which the total and longwave radiometers were characterized. The flight calibration instrumentation for the narror-field-of-view scanning radiometers is presented and evaluated.

Lee, Robert B., III↗

Molecular beam simulation of planetary atmospheric entry: Some recent results

Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of the simulation technique are discussed. It is shown that an open cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen. The simulation techniques used provide assistance in designing, developing, and (potentially) in testing and calibrating the required flight instrument.

French, J. B.↗

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeffrey Holt↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗