Summary of recent Raman Spectroscopy testing of SRS processes

This report describes several scoping projects conducted at SRNL using Raman spectroscopic methods for monitoring different aspects of nuclear waste and materials processing. One project examined the suitability of a Raman telescope for in situ measurement of solid residues in waste tanks. Characteristics evaluated for this equipment included radiation resistance, ease of use, and sensitivity. A second project monitored the nitrate content in liquid filtrate from the testing of a rotary microfilter using a fiber-based insertion probe. The third project made Raman measurements of various gases, including H 2 and NO x , in the headspace of a vessel while dissolving aluminum coupons in nitric acid. Measurements followed the evolution of these species in real time. Although the majority of these projects occurred in the laboratory environment, SRNL has substantial experience with implementing other optical techniques into nuclear materials processing environments. The work described in this report shows the potential of the Raman technology to provide real time measurements of species such as nitrate or hydroxide during sludge washing or evolved gases such as hydrogen or NO x during waste processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DoE Plasma Center for Momentum Transport and Flow Self-Organization in Plasmas: Non-linear Emergent Structure Formation in magnetized Plasmas and Rotating Magnetofluids

This report covers the UW-Madison activities that took place within a larger DoE Center Administered and directed by Professor George Tynan at the University of California, San Diego. The work at Wisconsin will also be covered in the final reporting for the entire center, which will be submitted by UCSD. There were two main activities, one experimental and one that was theoretical in nature, as part of the Center activities at the University of Wisconsin, Madison. First, the Center supported an experimentally focused postdoc (Chris Cooper) to carry out fundamental studies of momentum transport in rotating and weakly magnetized plasma. His experimental work was done on the Plasma Couette Experiment, a cylindrical plasma confinement device, with a plasma flow created through electromagnetically stirring plasma at the plasma edge facilitated by arrays of permanent magnets. Cooper's work involved developing optical techniques to measure the ion temperature and plasma flow through Doppler-shifted line radiation from the plasma argon ions. This included passive emission measurements and development of a novel ring summing Fabry-Perot spectroscopy system, and the active system involved using a diode laser to induce fluorescence. On the theoretical side, CMTFO supported a postdoc (Johannes Pueschel) to carry out a gyrokinetic extension of residual zonal flow theory to the case with magnetic fluctuations, showing that magnetic stochasticity disrupts zonal flows. The work included a successful comparison with gyrokinetic simulations. This work and its connection to the broader CMTFO will be covered more thoroughly in the final CMTFO report from Professor Tynan.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved chemical imaging based on stimulated TERS (Final Scientific-Technical Report-Phase-II-DE-SC0013172)

This is the Final Scientific/Technical Report for the DOE FastTrack SBIR Grant from Fiscal Year 2015. The report details the work pursued to scientifically demonstrate ultrahigh spatial resolution in ultrafast spectroscopy and commercially develop a product offering that provides the similar capability to other researchers. Chemical and electronic information associated with molecular-scale processes can be interrogated via optical spectroscopy. By utilizing two ultrafast lasers, one to “pump” and the other to “probe” with time delay between them, researchers are able to study various molecular and electronic dynamics with time resolution in femtosecond range. Due to the diffraction limit associated with these optical techniques, these techniques measure average behavior of ensemble of molecules since individual molecules are typically much smaller than the wavelengths of the lasers being utilized. This report presents the successful demonstration of ultrafast spectroscopy (temporal resolution of 150 femtosecond limited by the laser pulse width) of electronic recovery in carbon nanotubes, revealing different recovery dynamics for individual carbon nanotubes with spatial resolution of ~ 10 nm, more than 50X smaller than the wavelengths used to study them. The report also details the required instrumentation for such measurements and how it plans to offer a turnkey solution to the research community to provide such capability in a user-friendly and low maintenance package.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy-Recovery Linacs for Commercial Radioisotope Production - Phase I

Most radioisotopes are produced by nuclear reactors or positive ion accelerators, which are expensive to construct and to operate. Photonuclear reactions using bremsstrahlung photon beams from less-expensive electron linacs can generate isotopes of critical interest, but much of the beam energy in a conventional electron linac is dumped at high energy, making unwanted radioactivation. The largest part of this radioactivation may be completely eliminated by applying energy recovery linac technology to the problem with an additional benefit that the energy cost to produce a given amount of isotope is reduced. Consequently a Superconducting Radio Frequency (SRF) Energy Recovery Linac (ERL) is a path to a more diverse and reliable domestic supply of short-lived, high-value, high-demand isotopes at a cost lower than that of isotopes produced by reactors or positive-ion accelerators. A Jefferson Lab approach to this problem involves a thin photon production radiator, which allows the electron beam to recirculate through rf cavities so the beam energy can be recovered while the spent electrons are extracted and absorbed at a low enough energy to minimize unwanted radioactivation. The thicker isotope photoproduction target is not in the beam. MuPlus, with Jefferson Lab and Niowave, proposed to extend this ERL technology to the commercial world of radioisotope production. In Phase I we demonstrated that 1) the ERL advantage for producing radioisotopes is at high energies (~100 MeV), 2) the range of acceptable radiator thickness is narrow (too thin and there is no advantage relative to other methods and too thick means energy recovery is too difficult), 3) using optics techniques developed under an earlier STTR for collider low beta designs greatly improves the fraction of beam energy that can be recovered (patent pending), 4) many potentially useful radioisotopes can be made with this ERL technique that have never before been available in significant commercial quantities. We developed a plan for the Phase II project that started with a Conceptual Design Report (CDR) based on the results of the Phase I studies and concluded with a Technical Design Report (TDR) for a facility to make isotopes that are most attractive based on market analyses.

07 ISOTOPE AND RADIATION SOURCES↗

Basic Research of Intrinsic Tamper Indication Markings and Patterns Defined by Pulsed Laser Irradiation (Final Report)

Pulsed laser irradiation has been used to create complex, intrinsic markings that can be used as unique identifiers for authentication and asset protection. Markings have been made on the surface of various materials by rapidly scanning a focused laser beam across a designated area as large as several square inches. Markings include macro-scale patterns, such as barcodes, that contain encrypted information. More complex markings are comprised of macro-scale patterns and embedded, unique micro-scale features. Micro-scale features form spontaneously during scanned laser irradiation and have different shapes, spacings, color and other characteristics that are virtually impossible to recreate. The macro-scale patterns can be interrogated rapidly in the field using a digital camera, while the embedded micro-scale features are best evaluated in the laboratory using microscopy or related optical techniques. Interrogated markings are compared with archived maps of the original patterns (obtained at the time of their manufacture) to determine component authenticity. The majority of experiments have involved marking planar solids. A new instrument that marks non-planar substrates is described for future work.

36 MATERIALS SCIENCE↗

Acoustic Wafer Defect Detection System

Researchers at Los Alamos have developed the Acoustic Wafer Defect Detection System, a technology that enables rapid diagnosis of critical defects during wafer production. This technology is capable of both efficient and accurate detection of defects in wafers, including defects that are undetectable through current optical techniques. The system identifies the wafer defects by exciting resonant vibrations in the wafers and by exciting “crack breathing” modes. These vibrations cause the crack to periodically open and close. Specific resonance characteristics, combined with acoustic signatures resulting from crack breathing, result in a technique that is highly sensitive to cracked wafers. There are minimal custom parts used to build the system, and it can be easily implemented in nearly any wafer production plant with minimal modifications. We are seeking a commercialization partner to license the technology or partner through a Cooperative Research and Development Agreement (CRADA) to develop into a usable product for commercial purposes.

42 ENGINEERING↗

Generating Orbital Angular Momentum Beams in an FEL Oscillator

With the storage ring FEL at Duke University, we have established fundamental harmonic FEL lasing in a variety of coherently mixed orbital angular momentum (OAM) modes, with photons in the |l> and |-l> superposition states (l = 1, 2, 3) and with each eigenstate carrying l_h OAM. Spatially organized in Laguerre Gaussian modes, stable FEL lasing of these OAM beams has been achieved with reasonable power. Optical techniques have been developed to characterize these beams. The operation of such an OAM FEL paves the way for the generation of OAM gamma-ray beams via Compton scattering.

Wu, Y.K.↗

Brazil disc Testing of LX-17-1

When considering alternate test methods for assessing the tensile performance of insensitive plastic bonded explosive (PBX) materials, Brazil disc tensile testing is attractive from several standpoints. First, compared to the traditional dog-bone shaped specimen normally used in the direct tensile test, the Brazil test specimen is considerably easier to produce. Second, the Brazil specimen is compact, with a low aspect ratio that allows it to be machined from a wide variety of pressed geometries. Assuming test results are consistent and interpretable, the method could open up possibilities for rapid assessment of ultimate tensile strengths, and might be especially attractive when a large number of samples are to be tested. The trade-off for specimen simplicity is, however, that interpretation of the results from Brazil tests is inherently far less intuitive, and more difficult, than is the case with traditional tensile testing, since the method involves complex stress loading. As a result, the derivation of what one hopes are equivalent tensile failure stresses from Brazil testing necessitates some fairly involved calculations, requiring parameters that are not always readily obtained. In addition to some significant uncertainties, the specimen geometry does not lend itself easily to the accommodation of traditional strain measurement devices such as extensometers. As a consequence, optical techniques such as digital image correlation (DIC) are preferred when stress-strain curves are needed. In this test series we performed a sequence of experiments using Brazil discs made from LX-17-1. Tests were performed on samples at two different scaled sizes: discs that were 0.5 inches in diameter and 0.25 inch thick, and discs that were 1 inch in diameter and a 0.5 inch thick. Each of the specimen sets was tested using matching, equivalently scaled test fixtures, each with anvils whose radii were 0.25% greater than their respective specimen radii. All specimens tested were machined from billet pressed material made from Holston #851009 (LLNL tag #C-329) LX-17-1 molding powder. Tests were performed at two temperatures, +23 °C and +50 °C, with three each test redundancies at each condition. Based on data from this set of experiments we hoped to provide preliminary answers to a number of questions, including: 1) Roughly, what is the level of scatter in the data? 2) Are results scale independent, at least within the limited range of specimen sizes tested? 3) Using a consistent set of parameters, can we use the equations given by Sato and Awaji1 to calculate peak tensile stresses that are nearly equivalent to those measured using traditional dog-bone tensile testing methods.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Study of Chemical Changes in Uranium Oxyfluoride Particles Progress Report June 2008 - February 2009

The present study aims to demonstrate how knowledge of time-dependent changes in uranium oxyfluoride particles can benefit particle analyses for environmental sampling. Environmental sampling depends upon laboratory analysis of nuclear material that has often been exposed to the environment after it was produced. It is therefore important to understand how those environmental conditions might have changed the chemical composition of the material over time. To investigate this, we prepared a set of uranium oxyfluoride particles at the Institute for Reference Materials and Measurements (IRMM-DG Joint Research Centre of the European Commission, Belgium). These UO{sub 2}F{sub 2} particles were prepared from the release and subsequent hydrolysis of UF{sub 6} gas, and were stored at LLNL in environmental chambers, set to different humidity, temperature and lighting conditions. An experimental plan was drafted to assess the number of analyses required to track the changes in particle composition, morphology, and structure. Due to its high spatial resolution and excellent transmission, the NanoSIMS secondary ion mass spectrometer at LLNL was found to be the optimal tool to measure individual oxyfluoride particles. This was confirmed by our participation in the inter-laboratory measurement campaign for particle analysis (NUSIMEP-6), organized by the IRMM in June last year. The reported uranium isotope ratios demonstrated the precision and accuracy of the NanoSIMS and ims 3f SIMS measurements at LLNL, and provided a high degree of confidence that the new measurements on the UO{sub 2}F{sub 2} samples will be of comparable high quality. As fluorine is known to be a chemically-sensitive compound, we measured the intensity of the fluorine secondary ions relative to the ions generated by the matrix to evaluate the rate of particle degradation under different environmental conditions. A relative sensitivity factor was empirically determined to convert these measurements to absolute fluorine concentrations. Additional measurements in selected uranium compounds were carried out to account for variations in matrix composition. Because of the complexity of both the SIMS instruments, as well as the nature of the samples, we spent a substantial amount of time on instrument training and instrument set up. The latest NanoSIMS measurements on the freshly-prepared UO{sub 2}F{sub 2} particles however, showed that we are on the right track when it comes to determining the chemical changes in individual uranium particles. At PNNL, several optical techniques including cryogenic laser-induced time-resolved U(VI) fluorescence micro-spectroscopy, Raman spectroscopy, and Fourier transform infrared spectroscopy will be applied to investigate molecular transformations of the particles. As a control, dynamic SIMS measurements will also be performed on a subset of the samples sent to PNNL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of advanced laser diagnostics to hypersonic wind tunnels and combustion systems.

This LDRD was a Sandia Fellowship that supported Andrea Hsu's PhD research at Texas A&M University and her work as a visitor at Sandia's Combustion Research Facility. The research project at Texas A&M University is concerned with the experimental characterization of hypersonic (Mach>5) flowfields using experimental diagnostics. This effort is part of a Multidisciplinary University Research Initiative (MURI) and is a collaboration between the Chemistry and Aerospace Engineering departments. Hypersonic flight conditions often lead to a non-thermochemical equilibrium (NTE) state of air, where the timescale of reaching a single (equilibrium) Boltzmann temperature is much longer than the timescale of the flow. Certain molecular modes, such as vibrational modes, may be much more excited than the translational or rotational modes of the molecule, leading to thermal-nonequilibrium. A nontrivial amount of energy is therefore contained within the vibrational mode, and this energy cascades into the flow as thermal energy, affecting flow properties through vibrational-vibrational (V-V) and vibrational-translational (V-T) energy exchanges between the flow species. The research is a fundamental experimental study of these NTE systems and involves the application of advanced laser and optical diagnostics towards hypersonic flowfields. The research is broken down into two main categories: the application and adaptation of existing laser and optical techniques towards characterization of NTE, and the development of new molecular tagging velocimetry techniques which have been demonstrated in an underexpanded jet flowfield, but may be extended towards a variety of flowfields. In addition, Andrea's work at Sandia National Labs involved the application of advanced laser diagnostics to flames and turbulent non-reacting jets. These studies included quench-free planar laser-induced fluorescence measurements of nitric oxide (NO) and mixture fraction measurements via Rayleigh scattering.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Stacking Faults Originating from Star-Defects in 4H-SiC

Intense efforts are currently in progress to study various sources of basal plane dislocations (BPDs) in SiC epitaxial layers. BPDs can generate Shockley-type stacking faults (SSFs) in SiC epitaxial layers, which have been shown to be associated with the degradation of power devices. This study shows that the star-shaped defect can be a source of several BPDs in the epitaxial layer. We investigate the complex microstructure of the star defect, the generation of BPDs, and expansion of SSFs using various complementary microscopy and optical techniques. We show direct evidence that star-defects can be a nucleation point of single-SSFs that can expand at the core of the defect. Newly found secondary dislocation arrays extending over a few centimeters away are found to be emanating from the primary arms of the star defect. The presence of such dislocation walls and the expansion of single-SSFs will affect the yield of numerous die on a wafer. Further understanding of the formation mechanism of stacking faults generated from star-defects as provided in this study helps understand their effect on SiC-based devices, which is crucial to assess device reliability.

36 MATERIALS SCIENCE↗

Mini-Micropulse Lidar data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (mini-MPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. The mini-MPL deployed with ROAM-V is a 532 nm elastic and polarization lidar. The mini-MPL outputs normalized relative backscatter (NRB) derived from raw signal after after-pulse, overlap, and dead-time correction calibration. The depolarization ratio is calculated from the co-polarized and cross-polarized NRB (Flynna et al., 2007). The NRB and depolarization ratio data are resampled from the original data at 1-minute intervals. The vertical resolution of the mini-MPL data is 15 meters. The mini-MPL data can be used to determine the boundary layer, cloud top, and cloud bottom height and can be used to retrieve aerosol type and concentration profile. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu . Flynna, C. J., Mendozaa, A., Zhengb, Y., & Mathurb, S. (2007). Novel polarization-sensitive micropulse lidar measurement technique. Optics express, 15(6), 2785-2790.

54 ENVIRONMENTAL SCIENCES↗

Facilities office

Variable optical techniques applied to solar simulators

Source record↗