Search NASA⌕ Search

SEARCH · Search NASA

Results for “processes control processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Controls Status for Fermilab’s PIP-II Project

Testing of Cryomodule first articles at PIP-II's on-site Cryomodule Test Facility (CMTF), where EPICS based controls are already being used, has been invaluable to the project. In addition to validating hardware and controls components, it has provided opportunities to build buy-in and illicit meaningful feedback early-on. A device naming convention has also been significantly refined with an internal working group and the PIP-II integration team. Compressed air and Process Control Water (PCW) systems have been installed, and operations has been engaged in Phoebus display development in preparation for a transition to operations for these systems by 2026. Cryoplant hardware has been put in place, and collaboration between controls and PIP-IIs cryo group for IOC and display development is well underway for commissioning of cryoplant systems to begin early 2026. The project has also received beneficial occupancy of the High-Bay Building in October 2025, keeping us on schedule for Warm Front End commissioning to begin in 2027.

Crisp, Dan [Fermilab]↗

Freeze-Drying Makes Improved IPN And Semi-IPN Polymers

Novel process developed for production of interpenetrating polymer networks (IPN's) or semi-IPN's with greater fracture toughness and resistance to microcracks. Process controls degree of phase separation in IPN's. In experiment, IPN's and semi-IPN's formed by dissolving constituents in another common solvent in traditional method. Resins and composite materials produced were tested for both traditional and freeze-drying processes. Glass-transition temperatures and data from dynamic mechanical tests of freeze-dried IPN's and semi-IPN's demonstrated freeze-drying process provided much improved IPN's and semi-IPN's.

Pater, Ruth H.↗

A Reactive-Ion Etch for Patterning Piezoelectric Thin Film

Reactive-ion etching (RIE) under conditions described below has been found to be a suitable means for patterning piezoelectric thin films made from such materials as PbZr(1-x)Ti(x)O3 or Ba(x)Sr(1.x)TiO3. In the original application for which this particular RIE process was developed, PbZr(1-x)Ti(x)O3 films 0.5 microns thick are to be sandwiched between Pt electrode layers 0.1 microns thick and Ir electrode layers 0.1 microns thick to form piezoelectric capacitor structures. Such structures are typical of piezoelectric actuators in advanced microelectromechanical systems now under development or planned to be developed in the near future. RIE of PbZr(1-x)Ti(x)O3 is usually considered to involve two major subprocesses: an ion-assisted- etching reaction, and a sputtering subprocess that removes reactive byproducts. RIE is favored over other etching techniques because it offers a potential for a high degree of anisotropy, high-resolution pattern definition, and good process control. However, conventional RIE is not ideal for patterning PbZr(1-x)Ti(x)O3 films at a thickness as great as that in the original intended application. In order to realize the potential benefits mentioned above, it is necessary to optimize process conditions . in particular, the composition of the etching gas and the values of such other process parameters as radio-frequency power, gas pressure, gas-flow rate, and duration of the process. Guidelines for determining optimum conditions can be obtained from experimental determination of etch rates as functions of these parameters. Etch-gas mixtures of BCl3 and Cl2, some also including Ar, have been found to offer a high degree of selectivity as needed for patterning of PbZr(1-x)Ti(x)O3 films on top of Ir electrode layers in thin-film capacitor structures. The selectivity is characterized by a ratio of approx.10:1 (rate of etching PbZr(1-x)Ti(x)O3 divided by rate of etching Ir and IrO(x)). At the time of reporting the information for this article, several experiments on RIE in BCl3 and Cl2 (and sometimes Ar) had demonstrated the 10:1 selectivity ratio, and further experiments to enhance understanding and obtain further guidance for optimizing process conditions were planned.

Yang, Eui-Hyeok↗

Development Status of a CVD System to Deposit Tungsten onto UO2 Powder via the WCI6 Process

Nuclear Thermal Propulsion (NTP) is under development for deep space exploration. NTP's high specific impulse (> 850 second) enables a large range of destinations, shorter trip durations, and improved reliability. W-60vol%UO2 CERMET fuel development efforts emphasize fabrication, performance testing and process optimization to meet service life requirements. Fuel elements must be able to survive operation in excess of 2850 K, exposure to flowing hydrogen (H2), vibration, acoustic, and radiation conditions. CTE mismatch between W and UO2 result in high thermal stresses and lead to mechanical failure as a result UO2 reduction by hot hydrogen (H2) [1]. Improved powder metallurgy fabrication process control and mitigated fuel loss can be attained by coating UO2 starting powders within a layer of high density tungsten [2]. This paper discusses the advances of a fluidized bed chemical vapor deposition (CVD) system that utilizes the H2-WCl6 reduction process.

Mireles, O. R.↗

Picosecond Pulsed Laser Ablation for the Surface Preparation of Epoxy Composites

As part of a technical challenge under the Advanced Composites Program, methods for improving pre-bond process control for aerospace composite surface treatments and inspections, in conjunction with Federal Aviation Administration guidelines, are under investigation. The overall goal is to demonstrate high fidelity, rapid and reproducible surface treatment and surface characterization methods to reduce uncertainty associated with the bonding process. The desired outcomes are reliable bonded airframe structure, and reduced timeline to certification. In this work, laser ablation was conducted using a q-switched Nd:YVO4 laser capable of nominal pulse durations of 8 picoseconds (ps). Aerospace structural carbon fiber reinforced composites with an epoxy resin matrix were laser treated, characterized, processed into bonded assemblies and mechanically tested. The characterization of ablated surfaces were conducted using scanning electron microscopy (SEM), water contact angle (WCA) goniometry, micro laser induced breakdown spectroscopy (uLIBS), and electron spin resonance (ESR). The bond performance was assessed using a double cantilever beam (DCB) test with an epoxy adhesive. The surface characteristics and bond performance obtained from picosecond ablated carbon fiber reinforced plastics (CFRPs) are presented herein.

Palmieri, Frank↗

Development of an Uncertainty Model for the National Transonic Facility

This paper introduces an uncertainty model being developed for the National Transonic Facility (NTF). The model uses a Monte Carlo technique to propagate standard uncertainties of measured values through the NTF data reduction equations to calculate the combined uncertainties of the key aerodynamic force and moment coefficients and freestream properties. The uncertainty propagation approach to assessing data variability is compared with ongoing data quality assessment activities at the NTF, notably check standard testing using statistical process control (SPC) techniques. It is shown that the two approaches are complementary and both are necessary tools for data quality assessment and improvement activities. The SPC approach is the final arbiter of variability in a facility. Its result encompasses variation due to people, processes, test equipment, and test article. The uncertainty propagation approach is limited mainly to the data reduction process. However, it is useful because it helps to assess the causes of variability seen in the data and consequently provides a basis for improvement. For example, it is shown that Mach number random uncertainty is dominated by static pressure variation over most of the dynamic pressure range tested. However, the random uncertainty in the drag coefficient is generally dominated by axial and normal force uncertainty with much less contribution from freestream conditions.

Walter, Joel A.↗

Evaluation of control parameters for Spray-In-Air (SIA) aqueous cleaning for shuttle RSRM hardware

HD-2 grease is deliberately applied to Shuttle Redesigned Solid Rocket Motor (RSRM) D6AC steel hardware parts as a temporary protective coating for storage and shipping. This HD-2 grease is the most common form of surface contamination on RSRM hardware and must be removed prior to subsequent surface treatment. Failure to achieve an acceptable level of cleanliness (HD-2 calcium grease removal) is a common cause of defect incidence. Common failures from ineffective cleaning include poor adhesion of surface coatings, reduced bond performance of structural adhesives, and failure to pass cleanliness inspection standards. The RSRM hardware is currently cleaned and refurbished using methyl chloroform (1,1,1-trichloroethane). This chlorinated solvent is mandated for elimination due to its ozone depleting characteristics. This report describes an experimental study of an aqueous cleaning system (which uses Brulin 815 GD) as a replacement for methyl chloroform. Evaluation of process control parameters for this cleaner are discussed as well as cleaning mechanisms for a spray-in-air process.

Davis, S. J.↗

Real Time, In-line Monitoring of Hanford Tank Wastes - Year 1 Report

The team comprised of students, postdocs, early, mid and senior career scientists from Los Alamos National Laboratory, Savanah River National Laboratory, Georgia Tech and Florida International University, with the guidance of H2C, is developing a suite of in-line instruments for the Hanford high level waste (HLW) and low active waste (LAW) processes to provide near-real-time analysis of waste form physical properties and composition. The work builds on results from the recent DOE-ORP, EM Technology Development and other projects that demonstrated promise for the use of real-time in-line monitoring (RTIM) to measure chemical compositions of slurries of up to 20 weight % solids. The goal is for this instrument suite is to substantially reduce the need for sampling for process control. Sample waste, exposure associated with sample analysis, and the demand for an external laboratory facility would be greatly reduced. The throughput of waste treatment systems would be improved by elimination of the downtime caused by waiting for sample results. This translates into reduced process storage as process knowledge will be continuously updated in near-real-time. These breakthrough technologies would significantly reduce the life cycle cost and accelerate the schedule for the Hanford tank waste mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Global Positioning System Synchronized Active Light Autonomous Docking System

A Global Positioning System Synchronized Active Light Autonomous Docking System (GPSSALADS) for automatically docking a chase vehicle with a target vehicle comprises at least one active light emitting target which is operatively attached to the target vehicle. The target includes a three-dimensional array of concomitantly flashing lights which flash at a controlled common frequency. The GPSSALADS further comprises a visual tracking sensor operatively attached to the chase vehicle for detecting and tracking the target vehicle. Its performance is synchronized with the flash frequency of the lights by a synchronization means which is comprised of first and second internal clocks operatively connected to the active light target and visual tracking sensor, respectively, for providing timing control signals thereto, respectively. The synchronization means further includes first and second Global Positioning System receivers operatively connected to the first and second internal clocks, respectively, for repeatedly providing simultaneous synchronization pulses to the internal clocks, respectively. In addition, the GPSSALADS includes a docking process controller means which is operatively attached to the chase vehicle and is responsive to the visual tracking sensor for producing commands for the guidance and propulsion system of the chase vehicle.

Howard, Richard↗

Global Positioning System Synchronized Active Light Autonomous Docking System

A Global Positioning System Synchronized Active Light Autonomous Docking System (GPSSALADS) for automatically docking a chase vehicle with a target vehicle comprising at least one active light emitting target which is operatively attached to the target vehicle. The target includes a three-dimensional array of concomitantly flashing lights which flash at a controlled common frequency. The GPSSALADS further comprises a visual tracking sensor operatively attached to the chase vehicle for detecting and tracking the target vehicle. Its performance is synchronized with the flash frequency of the lights by a synchronization means which is comprised of first and second internal clocks operatively connected to the active light target and visual tracking sensor, respectively, for providing timing control signals thereto, respectively. The synchronization means further includes first and second Global Positioning System receivers operatively connected to the first and second internal clocks, respectively, for repeatedly providing simultaneous synchronization pulses to the internal clocks, respectively. In addition, the GPSSALADS includes a docking process controller means which is operatively attached to the chase vehicle and is responsive to the visual tracking sensor for producing commands for the guidance and propulsion system of the chase vehicle.

Howard, Richard T.↗

MAVEN - Mars Atmosphere and Volatile EvolutioN Mission

NASA's MAVEN mission (to be launched in late 2013) is the first mission to Mars devoted to sampling all of the upper atmosphere neutral and plasma environments, including the well-mixed atmosphere, the exosphere, ionosphere, outer magnetosphere and near-Mars solar wind. It will fill in some measurement gaps remaining from the successful Mars Global Surveyor and the on-going Mars Express missions. The primary science objectives of MAVEN are: 1. Provide a comprehensive picture of the present state of the upper atmosphere and ionosphere of Mars; 2. Understand the processes controlling the present state; and 3. Determine how loss of volatiles to outer space in the present epoch varies with changing solar condition - EUY, solar wind and interplanetary magnetic field measurements will provide the varying solar energy inputs into the system. Knowing how these processes respond to the Sun's energy inputs in the current epoch will provide a framework for projecting atmospheric processes back in time to profile MARS' atmospheric evolution and to explore "where the water went", A description will be given of the science objectives, the instruments, and the current status of the project, emphasizing the value of having collaborations between the MAVEN project and the Mars upper atmosphere science community.

Grebowsky, Joseph M.↗

International Space Station Acoustics – A Status Report

It is important to control acoustic noise aboard the International Space Station (ISS) to provide a satisfactory environment for voice communications, alarm audibility, and restful sleep, and to minimize the risk for hearing loss. Acoustic monitoring is an important part of the noise control process on ISS, providing critical data for trend analysis, noise exposure analysis, validation of acoustic analyses and predictions, and to provide strong evidence for ensuring crew health and safety, thus allowing Flight Certification. And since the primary noise sources on ISS include the environmental control and life support system’s air revitalization system (fans and airflow) and active thermal control system (pumps and water flow), acoustic monitoring will indicate changes in hardware noise emissions that may indicate system degradation or performance issues. This paper provides the current acoustic levels in the ISS modules and sleep stations, and is an update to the status presented in 2018. Since this last status report, noise levels have remained consistent, but issues with stalled fan noise and unexplained low frequency spectral peaks have caused some exceedances to requirements. Noise levels in the Russian Segment have either remained consistent or have been reduced slightly, except for the new Multipurpose Laboratory Module, which has some significant noise exceedances.

Christopher S Allen↗

Optical property measurements as a diagnostic tool for control of materials processing in space and on Earth

A new method is described, including results, to measure, control, and follow containerless processing in ground based levitators. This technique enables instantaneous optical property measurements from a transient solid or liquid surface concurrent with true temperature measurement. This was used successfully as a diagnostic tool to follow processing of Al, Si, and Ti during electromagnetic levitation. Experiments on Al show the disappearance of the oxide (emittance 0.33) at ca. 1300 C leaving a liquid surface with an emittance of 0.06. Electromagnetic levitation of silicon shows a liquid with a constant emittance (0.2) but with a solid whose emittance decreases very rapidly with increasing temperature. Consequently, the processing of materials at high temperatures can be controlled quite well through the control of surface optical properties.

Krishnan, Shankar↗

Requirements for theoretical models of outflows

Recent observational and theoretical investigations of astrophysical mass outflows are reviewed, with a focus on the basic physical principles. Specific limitations on the observational data and their interpretation are listed and discussed. Modeling problems considered include the role of the critical point in determining the mass-loss rate and terminal velocity, the physical processes controlling density at the critical point, the possible coexistence of multiple mass-loss mechanisms, time scales, instabilities and phase changes, multiphase atmospheres and winds, the definition of geometries, the role of the environment, explosive transient events, stochastic phenomena, mode-mode coupling and damping processes, departures from ionization equilibrium, and nonthermal phenomena.

Linsky, Jeffrey L.↗

Core-Plasma Refilling and Erosion: Science Justification

Global magnetospheric models do not currently couple dynamic plasmaspheric plasma due to computational limitations that will be overcome by 2050. A true GGCM will need to include a dynamic plasmasphere for both physics and space weather prediction. Such inclusion requires that we answer longstanding, fundamental questions about the life cycle of core (<10 eV, plasmaspheric) plasma: how it gets into the inner magnetosphere, and how it is eroded. Erosion and refilling are processes controlling a fundamental space plasma population. During every geomagnetic disturbance, tens of metric tons of plasma are rapidly eroded away, then slowly and unevenly replenished. After several decades we still do not understand the cross-scale mechanisms proposed to be responsible for these 2 processes. Removal and replacement of this enormous plasma mass is as important to the dynamics of the magnetosphere as solar-wind driving. Our community must dedicate the resources and effort needed to solve this enduring puzzle. Other white papers submitted in response to the HP2050 call are discussing cold plasma and ionospheric outflow in more general contexts. This white paper deals specifically with the science justification for studying refilling and erosion.

Plasmasphere, core-plasma, erosion, refilling↗

Unsupervised multimodal fusion of in-process sensor data for advanced manufacturing process monitoring

Effective monitoring of manufacturing processes is crucial for maintaining product quality and operational efficiency. Modern manufacturing environments often generate vast amounts of complementary multimodal data, including visual imagery from various perspectives and resolutions, hyperspectral data, and machine health monitoring information such as actuator positions, accelerometer readings, and temperature measurements. However, fusing and interpreting this complex, high-dimensional data presents significant challenges, particularly when labeled datasets are unavailable or impractical to obtain. This paper presents a novel approach to multimodal sensor data fusion in manufacturing processes, inspired by the Contrastive Language-Image Pre-training (CLIP) model. We leverage contrastive learning techniques to correlate different data modalities without the need for labeled data, overcoming limitations of traditional supervised machine learning methods in manufacturing contexts. Our proposed method demonstrates the ability to handle and learn encoders for five distinct modalities: visual imagery, audio signals, laser position (x and y coordinates), and laser power measurements. By compressing these high-dimensional datasets into low-dimensional representational spaces, our approach facilitates downstream tasks such as process control, anomaly detection, and quality assurance. The unsupervised nature of our method makes it broadly applicable across various manufacturing domains, where large volumes of unlabeled sensor data are common. We evaluate the effectiveness of our approach through a series of experiments, demonstrating its potential to enhance process monitoring capabilities in advanced manufacturing systems. This research contributes to the field of smart manufacturing by providing a flexible, scalable framework for multimodal data fusion that can adapt to diverse manufacturing environments and sensor configurations. The proposed method paves the way for more robust, data-driven decision-making in complex manufacturing processes.

Contrastive Learning↗

Condensate Recycling in Closed Plant Growth Chambers

Water used in the the Controlled Ecological Life Support System (CELSS) Breadboard Project at the Kennedy Space Center is being recycled. Condensation is collected in the air ducts, filtered and deionized, and resupplied to the system for nutrient solutions, supplemental humidification, solvents and diluents. While the system functions well from a process control standpoint, precise and accurate tracking of water movement through the system to answer plant physiological questions is not consistent. Possible causes include hardware errors, undetected vapor loss from chamber leakage, and unmeasured changes in water volume in the plant growth trays.

Bledsoe, J. O.↗

Annealing effects in plated-wire memory elements. II - Recrystallization in Permalloy films.

Results of grain-size measurements in Permalloy platings suggest that recrystallization is possible at temperatures as low as 200 C, but that it is an extremely heterogeneous process. No worthwhile correlation was found to exist between observed grain size and magnetic dispersion in samples aged in the temperature range from 180 to 230 C. It is suggested that the magnetic aging which occurs under these conditions may be due to some other diffusion-controlled process than recrystallization; a process such as chemical homogenization is tentatively preferred.

Marquardt, S. J.↗