Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Carbon Dioxide Flux Measurement System (CO2FLX) Instrument Handbook

The Southern Great Plains (SGP) carbon dioxide flux (CO2 flux) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), and sensible heat. The fluxes are obtained by the eddy covariance technique, which computes the flux as the mean product of the vertical wind component with CO2 and H2O densities, or estimated virtual temperature. A three-dimensional sonic anemometer is used to obtain the orthogonal wind components and the virtual (sonic) temperature. An infrared gas analyzer is used to obtain the CO2 and H2O densities. A separate sub-system also collects half-hour average measures of meteorological and soil variables from separate 4-m towers.

54 ENVIRONMENTAL SCIENCES↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Leakage Spectra of the EUCLID Experiment [Abstract]

Integral experiments with sub-critical and critical configurations of special nuclear material are performed in support of nuclear data validation and adjustment. Different nuclear data evaluations may have different values for individual cross sections due to uncertainties in (or lack of) differential experiments, but compensating errors in these data sets can lead to the same k eff results for one application while vastly different for another application. One example of this is 239 Pu, where both ENDF/B-VIII.0 and JEFF-3.3 correctly compute k eff of the Jezebel critical assembly, but the individual contributions from each reaction are vastly different. To help resolve this specific case, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project used machine learning to design a set of experiments to help resolve the compensating errors in 239 Pu. A total of six responses were measured during the experimental campaign, which constrain the data in ways that k eff alone cannot and will be used for adjustment of the nuclear data. One of these responses is the neutron leakage spectrum, which recent work has shown to be useful for constraining the prompt fission neutron spectrum and inelastic scattering. The neutron leakage spectra were measured utilizing a 3 in. right cylinder EJ-301D detector. The measured signal in the detector was deconvoluted using spectrum unfolding techniques, which are presented and compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel X-Ray Probes of Electronically Heterogeneous Quantum Materials

The goal of this research was to advance the use of resonant soft x-ray scattering (RSXS) by deepening our theoretical understanding of the technique and expanding its use to a wide range of materials. Under this award, we showed how RSXS techniques can be applied to oxide heterostructures, studied commensuration effects in Wigner crystals, discovered a charge density wave in nickel-arsenide superconductors, and measured time-resolved dynamics of charge order in copper-oxide superconductors, among many other achievements. This award contributed to adoption of RSXS techniques by researchers around the nation and the world.

36 MATERIALS SCIENCE↗

Anatomy of Continuous Mars SEIS and Pressure Data from Unsupervised Learning

The seismic noise recorded by the Interior Exploration using Seismic Investigations, Geodesy, and Heat Transport (InSight) seismometer (Seismic Experiment for Interior Structure [SEIS]) has a strong daily quasi-periodicity and numerous transient microevents, associated mostly with an active Martian environment with wind bursts, pressure drops, in addition to thermally induced lander and instrument cracks. That noise is far from the Earth’s microseismic noise. Quantifying the importance of nonstochasticity and identifying these microevents is mandatory for improving continuous data quality and noise analysis techniques, including autocorrelation. Cataloging these events has so far been made with specific algorithms and operator’s visual inspection. We investigate here the continuous data with an unsupervised deep-learning approach built on a deep scattering network. This leads to the successful detection and clustering of these microevents as well as better determination of daily cycles associated with changes in the intensity and color of the background noise. We first provide a description of our approach, and then present the learned clusters followed by a study of their origin and associated physical phenomena. We show that the clustering is robust over several Martian days, showing distinct types of glitches that repeat at a rate of several tens per sol with stable time differences. We show that the clustering and detection efficiency for pressure drops and glitches is comparable to or better than manual or targeted detection techniques proposed to date, noticeably with an unsupervised approach. Finally, here we discuss the origin of other clusters found, especially glitch sequences with stable time offsets that might generate artifacts in autocorrelation analyses. We conclude with presenting the potential of unsupervised learning for long-term space mission operations, in particular, for geophysical and environmental observatories.

58 GEOSCIENCES↗

Biomolecular complex viewed by dynamic nuclear polarization solid-state NMR spectroscopy

Solid-state nuclear magnetic resonance (ssNMR) is an indispensable tool for elucidating the structure and dynamics of insoluble and non-crystalline biomolecules. The recent advances in the sensitivity-enhancing technique magic-angle spinning dynamic nuclear polarization (MAS-DNP) have substantially expanded the territory of ssNMR investigations and enabled the detection of polymer interfaces in a cellular environment. This article highlights the emerging MAS-DNP approaches and their applications to the analysis of biomolecular composites and intact cells to determine the folding pathway and ligand binding of proteins, the structural polymorphism of low-populated biopolymers, as well as the physical interactions between carbohydrates, proteins, and lignin. Furthermore, these structural features provide an atomic-level understanding of many cellular processes, promoting the development of better biomaterials and inhibitors. It is anticipated that the capabilities of MAS-DNP in biomolecular and biomaterial research will be further enlarged by the rapid development of instrumentation and methodology.

36 MATERIALS SCIENCE↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ spin coater for multimodal grazing incidence x-ray scattering studies

We present herein a custom-made, in situ, multimodal spin coater system with an integrated heating stage that can be programmed with spinning and heating recipes and that is coupled with synchrotron-based, grazing-incidence wide- and small-angle x-ray scattering. The spin coating system features an adaptable experimental chamber, with the ability to house multiple ancillary probes such as photoluminescence and visible optical cameras, to allow for true multimodal characterization and correlated data analysis. This system enables monitoring of structural evolutions such as perovskite crystallization and polymer self-assembly across a broad length scale (2 Å–150 nm) with millisecond temporal resolution throughout a complete thin film fabrication process. The use of this spin coating system allows scientists to gain a deeper understanding of temporal processes of a material system, to develop ideal conditions for thin film manufacturing.

47 OTHER INSTRUMENTATION↗

Suppression of Deflecting Forces in Planar-Symmetric Dielectric Wakefield Accelerating Structures with Elliptical Bunches

Wakefield based accelerators capable of accelerating gradients two orders of magnitude higher than present accelerators offer a path to compact high energy physics instruments and light sources. However, for high gradient accelerators, beam instabilities driven by commensurately high transverse wakefields limit beam quality. It has been previously theoretically shown that transverse wakefields can be reduced by elliptically shaping the transverse sizes of beams in dielectric structures with planar symmetry. We report here experimental measurements that demonstrate reduced transverse wakefields for elliptical beams in planar symmetric structures which are consistent with theoretical models. Furthermore, these results may enable the design of gigavolt-per-meter gradient wakefield based accelerators that produce and stably accelerate high quality beams.

47 OTHER INSTRUMENTATION↗

Bayesian Component Separation for DESI LAE Automated Spectroscopic Redshifts and Photometric Targeting

Lyα emitters (LAEs) are valuable high-redshift cosmological probes traditionally identified using specialized narrowband photometric surveys. In ground-based spectroscopy, it can be difficult to distinguish the sharp LAE peak from residual sky emission lines using automated methods, leading to misclassified redshifts. We present a Bayesian spectral component separation technique to automatically determine spectroscopic redshifts for LAEs while marginalizing over sky residuals. We use visually inspected spectra of LAEs obtained using the Dark Energy Spectroscopic Instrument (DESI) to create a data-driven prior and can determine redshift by jointly inferring sky residual, LAE, and residual components for each individual spectrum. We demonstrate this method on 881 spectroscopically observed z = 2–4 DESI LAE candidate spectra and determine their redshifts with >90% accuracy when validated against visually inspected redshifts. Using the Δχ$^{2}$ value from our pipeline as a proxy for detection confidence, we then explore potential survey design choices and implications for targeting LAEs with medium-band photometry. This method allows for scalability and accuracy in determining redshifts from DESI spectra, and the results provide recommendations for LAE targeting in anticipation of future high-redshift spectroscopic surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Scientific Case for Concurrent Neutron and X-ray Scattering and Spectroscopy

The interrogation of materials with X-rays or neutrons to determine the structure, energetics, and dynamics of materials is fundamental to advancing materials' physical and chemical science and developing innovative material technologies. A transcending challenge in developing novel materials is that progress hinges on understanding the structure and dynamics across multiple time and length scales in complex materials that feature multiple components, interfaces, and compositions. Despite the ever-growing demands on materials’ characterization, existing approaches are almost exclusively based on isolated X-ray or neutron scattering, i.e., an approach commensurate with the more narrowly defined needs of fifty years ago. A three-day workshop sponsored by the U.S. National Science Foundation (NSF) analyzed the demand for concurrent neutron and X-ray (NeX) experiments. It was held at the Spring Hill Suites, San Jose, California, from June 2 to 4, 2022. In this workshop, 70 national and international experts ascertained the crucial need to establish NeX capabilities to advance the science of complex materials and systems in the US. Here, we illustrate the need for NeX scattering and spectroscopy experiments by showcasing examples that span areas as diverse as biomaterials, energy science, soft matter, and nanomaterials. To provide NeX capability will require new instrumentation that enables concurrent experiments. Affected areas include chemistry, soft matter, quantum materials, pure and applied chemistry, bioscience, geoscience, and applied materials. NeX benefits research outcomes due to the complementarity of the two techniques, which is essential for better model refinement. While joint refinement of data from separate neutron and X-ray experiments is critical to avoid ambiguities, especially in multiphase-multicomponent materials, concurrent experiments overcome scientific and technical barriers associated with single measurements, separated by location and, thus, time. Among all the examples, these factors introduce uncertainties in the results that complicate data analysis. [1,2] [3] While models are strongly sample-dependent, the principles of joint refinement are generally applicable to these disciplines, including the development of advanced parameterization, modeling, and analysis techniques that also consider the temporal and spatial resolutions of the two methods, leading to unambiguous data interpretation. Solutions for technical barriers must be found to realize NeX experiments, including developing robust sample environments that meet the optical requirements of neutrons and X-rays.

36 MATERIALS SCIENCE↗

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

The Spectroscopic Data Processing Pipeline for the Dark Energy Spectroscopic Instrument

Abstract We describe the spectroscopic data processing pipeline of the Dark Energy Spectroscopic Instrument (DESI), which is conducting a redshift survey of about 40 million galaxies and quasars using a purpose-built instrument on the 4 m Mayall Telescope at Kitt Peak National Observatory. The main goal of DESI is to measure with unprecedented precision the expansion history of the universe with the baryon acoustic oscillation technique and the growth rate of structure with redshift space distortions. Ten spectrographs with three cameras each disperse the light from 5000 fibers onto 30 CCDs, covering the near-UV to near-infrared (3600–9800 Å) with a spectral resolution ranging from 2000 to 5000. The DESI data pipeline generates wavelength- and flux-calibrated spectra of all the targets, along with spectroscopic classifications and redshift measurements. Fully processed data from each night are typically available to the DESI collaboration the following morning. We give details about the pipeline’s algorithms, and provide performance results on the stability of the optics, the quality of the sky background subtraction, and the precision and accuracy of the instrumental calibration. This pipeline has been used to process the DESI Survey Validation data set, and has exceeded the project’s requirements for redshift performance, with high efficiency and a purity greater than 99% for all target classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Ion Mobility Spectrometry-Mass Spectrometry for High-Throughput Analysis

Ion mobility spectrometry is a widely used analytical technique providing gas phase separation of molecules. It has received increasing attention in the recent years with the advancement in technology development and the availability of commercial instruments. In this chapter, we introduced the ion mobility fundamental theory and provided examples of IMS applications, especially for isomer separation, collision cross section database generation, high throughput analysis workflows, software tools for IMS data analysis, and ongoing high resolution SLIM IMS development. While IMS is not yet routinely utilized in drug discovery and pharmaceutical industry, there has been increased interest in high throughput library screening and antibody characterization. With all the ongoing development in IMS technology and informatics, we foresee more and more exciting applications of high throughput IMS analysis in different fields including omics studies, drug discovery and clinical applications in the near future.

Ross, Dylan H.↗