Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Mapping strain fields induced in Zr-based bulk metallic glasses during in-situ nanoindentation by X-ray nanodiffraction

A pioneer in-situ synchrotron X-ray nanodiffraction approach for characterization and visualization of strain fields induced by nanoindentation in amorphous materials is introduced. In-situ nanoindentation experiments were performed in transmission mode using a monochromatic and highly focused sub-micron X-ray beam on 40 μm thick Zr-based bulk metallic glass under two loading conditions. Spatially resolved X-ray diffraction scans in the deformed volume of Zr-based bulk metallic glass covering an area of 40 × 40 μm{sup 2} beneath the pyramidal indenter revealed two-dimensional map of elastic strains. The largest value of compressive elastic strain calculated from diffraction data at 1 N load was −0.65%. The region of high elastic compressive strains (<−0.3%) is located beneath the indenter tip and has radius of 7 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Provenance-Enabling DOE Visualization Applications

VisTrails, Inc.’s goal main charter has been to develop provenance management solutions for software tools. As the use of computation increases, keeping track of computational processes and the data they consume and derive is essential for many applications. Provenance (also referred to as audit trail, lineage, and pedigree) captures information about the steps used to generate a given data product. Such information provides important documentation that is key to preserving the data, to determining the data’s quality and authorship, and to reproducing as well as validating the results. Given the growing complexity of the computational processes and the volume of data they manipulate, manual approaches to maintaining provenance are both tedious and error-prone. At VisTrails, Inc., we have implemented infrastructure that can be used to provenance-enable existing tools. We have developed a series of plugins for specific applications, including ParaView and VisIt, which enable these applications to capture provenance. While developing these plugins, we identified general patterns across different applications, and these were used to inform the design of a general framework: the VisTrails Provenance Software Development Kit (SDK). The SDK encapsulates a set of core functionality including methods for capture, navigation, analysis and re-use of provenance. It allows application or plugin developers to more effectively provide provenance support: they can use the core functionality and write code only to handle application specific components. The SDK includes features that can be used in any application, for example, a refined interface for browsing the intermediate and final results captured. While the application-specific plugins were written in Python, the SDK was written from scratch in C++. This has led not only to substantial gains in performance but also the ability to integrate the SDK with applications written in other languages, including Java. To ensure that the SDK supported all of the functionality in the application-specific plugins, we have rewritten some of the existing plugins using the SDK. The SDK can be downloaded from www.vistrals.com/sdk.html.

97 MATHEMATICS AND COMPUTING↗

Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production. This technique is widely applicable and is not limited to crystal growth processes.

36 MATERIALS SCIENCE↗

X-ray Spray Diagnostics: Comparing Sources and Techniques

Unveiling the internal structure of sprays for propulsion applications is difficult under conditions with high optical extinction. While a number of laser-based techniques have been utilized at intermediate to high optical densities of 2 to 4 (Log10 scale), it is difficult to extract quantitative information under these conditions. The ability of X-rays to penetrate even the most optically dense sprays has enabled quantitative investigation of liquid volume fractions for a variety of applications. Much of the development in this area has taken place utilizing the Advanced Photon Source at Argonne National Laboratory. This paper makes a comparison between two sources: including the bright, coherent, monochromatic, pulsed beam at the Advanced Photon Source and an incoherent, polychromatic, sealed-tube source at the X-ray Flow Visualization Facility at Iowa State University. Studies of dense sprays and static fluid samples were conducted at both facilities to compare performance characteristics of each source for a variety of operating conditions. Data for solid-cone and impinging-jet sprays are presented, and challenges with utilizing polychromatic, incoherent sources are discussed.

43 PARTICLE ACCELERATORS↗

Evaluation of Geologic Carbon Storage Resource Estimates (SREs) of Cambrian Ordovician Units within the CarbonSAFE Prefeasibility Study Region Subtasks 4.2 and 4.3 – Topical Report

This report by the Indiana Geological & Water Survey (IGWS) assessed the storage resource estimate (SRE) of Cambrian-Ordovician stratigraphic units located within the CarbonSAFE prefeasibility area within the Illinois Basin. A comprehensive data set of wireline logs and petrophysical information was used. These data include core analysis for porosity and permeability, and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for four potential storage reservoirs (Upper Ordovician Trenton Limestone/Black River Group, Middle Ordovician St. Peter Sandstone, Lower Ordovician and Upper Cambrian Knox Supergroup, including a separate assessment for the lower Knox Potosi Dolomite. The resultant SREs volumes are displayed using georeferenced maps and boxplots. The latter allow for comparing data statistics (mean values and variability) between five methods employed for the SRE calculations. Differences observed in SRE results from the five methods are mainly attributable to differences in the data used for porosity in each method. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Accurate Analysis of the Change in Volume, Location, and Shape of Metastatic Cervical Lymph Nodes During Radiotherapy

Purpose: To establish a method for the accurate acquisition and analysis of the variations in tumor volume, location, and three-dimensional (3D) shape of tumors during radiotherapy in the era of image-guided radiotherapy. Methods and Materials: Finite element models of lymph nodes were developed based on computed tomography (CT) images taken before the start of treatment and every week during the treatment period. A surface geometry map with a volumetric scale was adopted and used for the analysis. Six metastatic cervical lymph nodes, 3.5 to 55.1 cm{sup 3} before treatment, in 6 patients with head and neck carcinomas were analyzed in this study. Three fiducial markers implanted in mouthpieces were used for the fusion of CT images. Changes in the location of the lymph nodes were measured on the basis of these fiducial markers. Results: The surface geometry maps showed convex regions in red and concave regions in blue to ensure that the characteristics of the 3D tumor geometries are simply understood visually. After the irradiation of 66 to 70 Gy in 2 Gy daily doses, the patterns of the colors had not changed significantly, and the maps before and during treatment were strongly correlated (average correlation coefficient was 0.808), suggesting that the tumors shrank uniformly, maintaining the original characteristics of the shapes in all 6 patients. The movement of the gravitational center of the lymph nodes during the treatment period was everywhere less than {+-}5 mm except in 1 patient, in whom the change reached nearly 10 mm. Conclusions: The surface geometry map was useful for an accurate evaluation of the changes in volume and 3D shapes of metastatic lymph nodes. The fusion of the initial and follow-up CT images based on fiducial markers enabled an analysis of changes in the location of the targets. Metastatic cervical lymph nodes in patients were suggested to decrease in size without significant changes in the 3D shape during radiotherapy. The movements of the gravitational center of the lymph nodes were almost all less than {+-}5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrafast three-dimensional x-ray computed tomography

X-ray computed tomography (CT) is a well established visualization technique in medicine and nondestructive testing. However, since CT scanning requires sampling of radiographic projections from different viewing angles, common CT systems with mechanically moving parts are too slow for dynamic imaging, for instance of multiphase flows or live animals. Here, we introduce an ultrafast three-dimensional x-ray CT method based on electron beam scanning, which achieves volume rates of 500 s{sup -1}. Primary experiments revealed the capability of this method to recover the structure of phase boundaries in gas-solid and gas-liquid two-phase flows, which undergo three-dimensional structural changes in the millisecond scale.

42 ENGINEERING↗

Collimator design for a multipinhole brain SPECT insert for MRI

Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial sampling (in a Defrise phantom) and a reconstructed resolution of 5.0 mm (in a cold-rod phantom). The authors compared the 24-pinhole setup with a 34-pinhole system (with the same detector radius but a collimator radius of 156.63 mm) and found that 34 pinholes result in better uniformity but a worse reconstruction of the cold-rod phantom. The authors also compared the 24-pinhole system with a clinical triple-head UHR fan beam system based on contrast-to-noise ratio and found that the 24-pinhole setup performs better for the 6 mm hot and the 16 mm cold lesions and worse for the 8 and 10 mm hot lesions. Finally, the authors reconstructed noisy projection data of a Hoffman phantom with a 9 mm cold lesion and found that the lesion was slightly better visible on the multipinhole image compared to the fan beam image. Conclusions: The authors have optimized a stationary multipinhole SPECT insert for MRI and showed the feasibility of doing brain SPECT imaging inside a MRI with an image quality similar to the best clinical SPECT systems available.

60 APPLIED LIFE SCIENCES↗

SU-F-T-99: Data Visualization From a Treatment Planning Tracking System for Radiation Oncology

Purpose: A treatment planning process tracker database with input forms and a TV-viewable display webpage was developed and implemented in our clinic to collect time data points throughout the process. Tracking plan times is important because it directly affects the patient quality of care. Simply, the longer a patient waits after their initial simulation CT for treatment to begin, the more time the cancer has to progress. The tracker helps to drive workflow through the clinic, while the data collected can be used to understand and manage the process to find and eliminate inefficiencies. Methods: The overall process steps tracked are CT-simulation, mark patient, draw normal contours, draw target volumes, create plan, and review/approve plan. Time stamps for task completion were extracted and used to generate a set of clinic metrics, among which include average time for each step in the process split apart by type of treatment, average time to completion for plans started in a given week, and individual overall completion time per plan. Results: Trends have been tracked for fourteen weeks of clinical data (196 plans). On average, drawing normal contours and target volumes is taking 2–5 times as long as creating the plan itself. This is potentially an issue because it could mean the process is taking too long initially, and it could be forcing the planning step to be done in a short amount of time. We also saw from our graphs that there appears to be no clear trend on the average amount of time per plan week-to-week. Conclusion: A tracker of this type has the potential to provide insight into how time is utilized in our clinic. By equipping our dosimetrists, radiation oncologists, and physicists with individualized metric sets, the tracker can help provide visibility and drive workflow. Funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

A Real-Time Data Dashboard for Monitoring Travel Behavior

When running a smartphone app-based travel behavior study, it is important to keep participants engaged in contributing data. Long study durations and/or large samples make it difficult to engage participants in reporting their travel behavior. We developed a dashboard web application called 'emdash' to facilitate and ease the data collection maintenance task. It allows deployers to view trip trajectories, track which participants are uploading data, and generate report ready plots. Emdash can also be useful for deployers to identify ways to best encourage a particular transportation mode shift and to provide feedback and reporting to participants. Using the dashboard, a single admin was able to support a classic travel study with 80 participants. The dashboard is currently deployed in a two-year electric bike (e-bike) pilot study called CanBikeCO, conducted in six locations across Colorado, USA. CanBikeCO targets carbon emissions reduction and equity improvement by evaluating changes to participants' travel behavior when they are offered free e-bikes. Each CanBikeCO location has access to their own version of emdash to help them monitor and support participants. After testing and gathering feedback, we made improvements to the dashboard's usability and scalability, and proposed a method to make detecting data issues easier. Improvements include configurable options and limiting the volume of data sent to the dashboard as study size and duration increase.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗

Automated Image Segmentation and Processing Pipeline Applied to X–Ray Computed Tomography Studies of Pitting Corrosion in Aluminum Wires

Understanding pitting corrosion is critical, yet its kinetics and morphology remain challenging to study from X-ray computed tomography (XCT) due to manual segmentation barriers. To address this, an automated pipeline leveraging deep learning for efficient large-scale XCT analysis is developed, revealing new corrosion insights. The pipeline enables pit segmentation, 3D reconstruction, statistical characterization, and a topological transformation for visualization. Here, the pipeline is applied to 87 648 XCT images capturing commercial purity aluminum (1100 Al) wire exposed to sodium chloride (NaCl) salt particles over a period of 122 h. The pipeline achieves complete feature extraction and statistical quantification across the entire XCT dataset, leveraging distributed computing environment for high efficiency. Global growth kinetics such as high-level stepwise sigmoidal volume loss patterns and granular individual pit developments are both captured for 36 detected pits. By combining automation, computer vision, and extensive XCT datasets, this research accelerates precise corrosion assessment to enable materials science discoveries at scale.

36 MATERIALS SCIENCE↗

Learning and Memory Following Conformal Radiation Therapy for Pediatric Craniopharyngioma and Low-Grade Glioma

Purpose: The primary objective of this study was to examine whether children with low-grade glioma (LGG) or craniopharyngioma had impaired learning and memory after conformal radiation therapy (CRT). A secondary objective was to determine whether children who received chemotherapy before CRT, a treatment often used to delay radiation therapy in younger children with LGG, received any protective benefit with respect to learning. Methods and Materials: Learning and memory in 57 children with LGG and 44 children with craniopharyngioma were assessed with the California Verbal Learning Test-Children's Version and the Visual-Auditory Learning tests. Learning measures were administered before CRT, 6 months later, and then yearly for a total of 5 years. Results: No decline in learning scores after CRT was observed when patients were grouped by diagnosis. For children with LGG, chemotherapy before CRT did not provide a protective effect on learning. Multiple regression analyses, which accounted for age and tumor volume and location, found that children treated with chemotherapy before CRT were at greater risk of decline on learning measures than those treated with CRT alone. Variables predictive of learning and memory decline included hydrocephalus, shunt insertion, younger age at time of treatment, female gender, and pre-CRT chemotherapy. Conclusions: This study did not reveal any impairment or decline in learning after CRT in overall aggregate learning scores. However, several important variables were found to have a significant effect on neurocognitive outcome. Specifically, chemotherapy before CRT was predictive of worse outcome on verbal learning in LGG patients. In addition, hydrocephalus and shunt insertion in craniopharyngioma were found to be predictive of worse neurocognitive outcome, suggesting a more aggressive natural history for those patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of grain-boundary geometry and pores morphology in dense and porous cubic zirconia polycrystals

Highlights: • Cubic zirconia sinters were investigated in three dimensions using dual-beam FEGSEM. • The 3D-EBSD technique was successfully applied to non-conductive ceramics. • New sample preparation approach to automated 3D-EBSD was proposed. • Grain boundary microstructures were reconstructed from inverse pole figure maps. • Pore microstructures were reconstructed from image quality maps. - Abstract: Three-dimensional electron backscatter diffraction technique was used for the visualization of grain boundary geometry and pore morphology in cubic zirconia. A set of four samples sintered under different conditions was investigated. Specimens which were characterized by energy dispersive spectroscopy and X-ray diffraction were entirely composed of cubic phase. Investigations of boundaries and pore structures were carried out in a dual-beam scanning electron microscope. For each sample, a volume of 1000 μm{sup 3} was investigated. The analysis of grain boundary networks reconstructed from inverse pole figure maps revealed a strong dependence between grain boundary density and sample preparation parameters. Sintering also affects the size and distribution of pores. The total number of grains analyzed varied from 17 to 357 and the calculated volume of cavities from 0.01% to 21%. This paper shows the application of three-dimensional crystallographic orientation analysis to characterize the microstructure of yttria stabilized zirconia ceramics.

36 MATERIALS SCIENCE↗

Determining Coal Ash Impacts on Radium and Thorium Background Levels in Soil Using Rare Earth Element Analyses - 18604

One challenge at large remediation sites contaminated with radiological materials is differentiating between low-level site-related contamination and NORM. This is because sites contaminated with radiological materials, such as thorium processing and mining and milling facilities, often generate wastes that contain contaminants that are similar to NORM deposits. For sites in urban areas, this issue is further compounded due to the presence of historic industrial fill (historic fill) containing materials such as fly ash, coal ash, and red brick, that exhibit elevated radioactivity levels. These materials often have activity levels near, or even well above, a site's cleanup goal. At a large Superfund Site in the eastern US (Site), many of the suspected Site-related fill areas are commingled with coal and fly ash. As the cleanup criteria for the radionuclides of concern (ROC), radium (Ra) and thorium (Th), is 5 pico-Curies per gram above background, a four-pronged approach was developed to determine if the coal and fly ash are impacting the background levels of the ROCs. This evaluation included a review of boring logs to visually confirm the presence of historic fill, as well as coal fragments and coal ash; a literature review to establish the typical concentrations of Ra and Th found in coal and fly ash from US sources; the use of rare earth analyses to establish chemical signatures for non-Site related historic fill containing coal ash versus Site-related fill; and a quantitative analysis of Site-related data to determine if the radioactivity levels in historic fill containing coal were elevated. Soil samples were collected from two locations at the Site; fill areas containing coal ash that were not suspected to be impacted by Site activities, as well as fill areas containing coal ash that were associated with the former processing facility. These samples were analyzed for rare earth elements (REE), as well as Ra-228 and Th-232 and the ratios of lanthanum, cerium, and neodymium to Ra-228 and Th-232 were established for each sample. Based on a comparison of these data, a strong correlation was established between the rare earth/thorium decay chain ratios and the classification of material as either Site or non-Site related. These data were used to develop a higher background activity for fill areas containing non-Site related NORM. While the cleanup level defined in the Record of Decision remained unchanged, the higher background derived from the fly ash/coal ash material, as identified by REE analyses, resulted in higher project screening levels, which ensured that excavation activities did not 'chase' material that was not Site-related. To date, use of the coal ash background level has saved millions of dollars in cleanup costs since non-Site related contamination is not being remediated. Use of this approach to determine the appropriate background level for a site is relatively straightforward since it relies on visual observation of the soil for coal and fly ash, along with REE analyses, which is an inexpensive, quick, and established analytical method for soil samples. As long as a good rare earth profile of both contaminated and natural (in this case fly ash and coal ash) material can be established, the results can be quite definitive, which could result in significant volume reduction by minimizing the amount of material excavated and disposed of. This will lead to cost and time savings for what could be an otherwise costly and potentially complex excavation. Anyone performing environmental remediation of NORM contaminated sites may benefit from this paper and presentation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computer-Assisted Diagnosis System for Breast Cancer in Computed Tomography Laser Mammography (CTLM)

Computed tomography laser mammography (Eid et al. Egyp J Radiol Nucl Med, 37(1): p. 633–643, 1) is a non-invasive imaging modality for breast cancer diagnosis, which is time-consuming and challenging for the radiologist to interpret the images. Some issues have increased the missed diagnosis of radiologists in visual manner assessment in CTLM images, such as technical reasons which are related to imaging quality and human error due to the structural complexity in appearance. The purpose of this study is to develop a computer-aided diagnosis framework to enhance the performance of radiologist in the interpretation of CTLM images. The proposed CAD system contains three main stages including segmentation of volume of interest (VOI), feature extraction and classification. A 3D Fuzzy segmentation technique has been implemented to extract the VOI. The shape and texture of angiogenesis in CTLM images are significant characteristics to differentiate malignancy or benign lesions. The 3D compactness features and 3D Grey Level Co-occurrence matrix (GLCM) have been extracted from VOIs. Multilayer perceptron neural network (MLPNN) pattern recognition has developed for classification of the normal and abnormal lesion in CTLM images. The performance of the proposed CAD system has been measured with different metrics including accuracy, sensitivity, and specificity and area under receiver operative characteristics (AROC), which are 95.2, 92.4, 98.1, and 0.98%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Persistent meanders and eddies lead to quasi-steady Lagrangian transport patterns in a weak western boundary current

The Brazil Current (BC) is a weak western boundary current flowing along the Southwestern Atlantic Ocean. It is frequently described as a flow with intense mesoscale activity and relatively low volume transport between 5.0 and 10.0 Sv. We use a 13-year eddy-resolving primitive-equation simulation to show that the presence of persistent meanders and eddies leads to characteristic quasi-steady Lagrangian transport patterns, aptly extracted through climatological Lagrangian Coherent Structures (cLCS). The cLCS position the surface expression of the BC core along the 2000-m isobath, in excellent visual agreement with high resolution satellite sea-surface temperature and the model Eulerian mean velocity. The cLCS deformation pattern also responds to zonally persistent cross-shelf SSH transition from positive (high) values near coastline to low (negative) values between 200- and 2000-m and back to positive (high) offshore from the 2000-m isobath. Zonally-paired cyclonic and anticyclonic structures are embedded in this transition, also causing the cLCS to deform into chevrons. An efficient transport barrier is identified close to the 200-m isobath confirmed by limited inshore movement of drogued drifters and accurately indicated by an along slope maxima of climatological strength of attraction. We also show that the persistent cyclonic and anticyclonic structures may induce localized cross-shelf transport. Regions of low climatological strength of attraction coincide with large shelves and with stagnant synthetic trajectories. We also show that cLCS accurately depict trajectories initiated at the location of Chevron’s spill (November 2011) as compared to synthetic and satellite-tracked trajectories, and the outline of the oil from that accident. There is also an agreement between the large-scale oil slicks reaching the Brazilian beaches (from August 2019 to February 2020) and the strength of climatological attraction at the coast. Our work also clarifies the influence of persistent mesoscale structures on the regional circulation. The identification and quantitative description of climatological Lagrangian coherent structures is expected to improve the effectiveness of future emergency response to oil spills, contingency planning, rescue operations, larval and fish connectivity assessment, drifter launch strategies, waste pollutant and marine debris dispersion and destination.

54 ENVIRONMENTAL SCIENCES↗

Assisted extraction of the energy level spacings and lever arms in direct current bias measurements of one-dimensional quantum wires, using an image recognition routine

A multiplexer technique is used to individually measure an array of 256 split gates on a single GaAs/AlGaAs heterostructure. This results in the generation of large volumes of data, which requires the development of automated data analysis routines. An algorithm is developed to find the spacing between discrete energy levels, which form due to transverse confinement from the split gate. The lever arm, which relates split gate voltage to energy, is also found from the measured data. This reduces the time spent on the analysis. Comparison with estimates obtained visually shows that the algorithm returns reliable results for subband spacing of split gates measured at 1.4 K. The routine is also used to assess direct current bias spectroscopy measurements at lower temperatures (50 mK). This technique is versatile and can be extended to other types of measurements. For example, it is used to extract the magnetic field at which Zeeman-split 1D subbands cross one another.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗