Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Radiofrequency hydrogen ion source with permanent magnets providing axial magnetic field

Uniform axial magnetic field of about 70 G is applied to a radiofrequency (rf) hydrogen ion source by arrays of permanent magnets. The plasma density and electron temperature downstream of the source and near the magnetic filter are compared with those in the previously described ion source, where the axial field has been applied by two solenoids. The source is operated at ∼350 kHz and above 10 kW rf power with a field-effect-transistor-based invertor power supply in 1.5 Pa hydrogen. The results show that the plasma density of ∼10{sup 19} m{sup −3} near the source exit and ∼10{sup 18} m{sup −3} near the magnetic filter can be obtained, which are higher than those with the solenoids.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broad Ion Beam Extraction from Large Bore ECR Ion Source with Cylindrically Comb-Shaped Magnetic Fields Configuration by Feeding Simultaneously 11 to 13 GHz and 2.45 GHz Microwaves

We tried to enlarge the operation window of an electron cyclotron resonance (ECR) ion source for producing the ECR plasma confined by cylindrically comb-shaped magnetic field, and for extracting the broad ion beam under the low pressures and low microwave powers. The magnetic field by permanent magnets constructs ECR zones at different positions for 2.45 GHz and 11 to 13 GHz microwaves, respectively. According to probe measurements, profiles of plasma density and temperature are different for using each single microwave. We conduct production of ECR plasma by launching simultaneously these two frequency microwaves, and obtain flat profiles of the electron density and the electron temperature. These profiles are not achieved by feeding single frequency microwave. It is found that plasma can be controllable on spatial profiles beyond wide operation window of plasma parameters. We conducted preliminary extracting and forming large bore ion beam from this source. We will make this source a part of tandem type ion source for the first stage. We investigated feasibility and hope to realize the device which has wide range operation window in a single device to produce many kinds of ion beams as like to universal source based on ECR ion source.

43 PARTICLE ACCELERATORS↗

New laser setup for the selective isotope production and investigation in a laser ion source at the IRIS (Investigation of Radioactive Isotopes on Synchrocyclotron) facility

New laser installation for the resonance ionization spectroscopy in a laser ion source and for rare isotope production has been recently put into operation at the IRIS (Investigation of Radioactive Isotopes on Synchrocyclotron) facility (Petersburg Nuclear Physics Institute, Gatchina). This is a significant improvement of a previous target-laser ion source device of the IRIS mass-separator, working on-line with 1 GeV proton beam of PNPI (Petersburg Nuclear Physics Institute) synchrocyclotron. It makes possible for us to get the isobarically clean radioactive isotope beams of a great number of chemical elements. New laser setup provides the two- or three-resonance step ionization in the range of wavelength of 265-850 nm. The first results obtained at the laser setup for Tl isotopes are presented.

07 ISOTOPE AND RADIATION SOURCES↗

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating

Multiple frequency heating is one of the most effective techniques to improve the performance of Electron Cyclotron Resonance (ECR) ion sources. The method increases the beam current and average charge state of the extracted ions and enhances the temporal stability of the ion beams. It is demonstrated in this paper that the stabilizing effect of two-frequency heating is connected with the suppression of electron cyclotron instability. Experimental data show that the interaction between the secondary microwave radiation and the hot electron component of ECR ion source plasmas plays a crucial role in mitigation of the instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emittance studies of the SNS external-antenna H- ion source

A new Allison-type emittance scanner has been built to characterize the ion sources and low energy beam transport systems at SNS. In this work, the emittance characteristics of the H- beam produced with the external-antenna RF-driven ion source and transported through the 2-lens electrostatic LEBT are studied. The beam emittance dependence on beam intensity, extraction parameters, and the evolution of the emittance and twiss parameters over beam pulse duration are presented.

Han, Baoxi↗

Latest Results from the Front End Test Stand High Performance H{sup -} Ion Source at RAL

The aim of the Front End Test Stand (FETS) project is to demonstrate that chopped low energy beams of high quality can be produced. FETS consists of a high power Penning Surface Plasma Ion Source, a 3 solenoid LEBT, a 3 MeV RFQ, a chopper and a comprehensive suite of diagnostics. This paper briefly outlines the status of the project, hardware installation and modifications. Results from experiments running the H{sup -} ion source at 2 ms pulse length are detailed: the discharge current is varied between 20 A and 50 A. The discharge repetition rate is varied between 12.5 and 50 Hz. Hydrogen and Caesium vapour flow rates are varied. The effect of electrode surface temperature and beam current droop are discussed. Peak beam currents of over 60 mA for 2 ms pulse length can be achieved. Normalised r.m.s emittances of 0.3 {pi}mm.mrads at the exit of the LEBT are presented for different source conditions.

07 ISOTOPE AND RADIATION SOURCES↗

Different approaches to modeling the LANSCE H{sup −} ion source filament performance

An overview of different approaches to modeling of hot tungsten filament performance in the Los Alamos Neutron Science Center (LANSCE) H{sup −} surface converter ion source is presented. The most critical components in this negative ion source are two specially shaped wire filaments heated up to the working temperature range of 2600 K–2700 K during normal beam production. In order to prevent catastrophic filament failures (creation of hot spots, wire breaking, excessive filament deflection towards source body, etc.) and to improve understanding of the material erosion processes, we have simulated the filament performance using three different models: a semi-empirical model, a thermal finite-element analysis model, and an analytical model. Results of all three models were compared with data taken during LANSCE beam production. The models were used to support the recent successful transition from the beam pulse repetition rate of 60 Hz–120 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Size scaling of negative hydrogen ion sources for fusion

The RF-driven negative hydrogen ion source (H{sup −}, D{sup −}) for the international fusion experiment ITER has a width of 0.9 m and a height of 1.9 m and is based on a ⅛ scale prototype source being in operation at the IPP test facilities BATMAN and MANITU for many years. Among the challenges to meet the required parameters in a caesiated source at a source pressure of 0.3 Pa or less is the challenge in size scaling of a factor of eight. As an intermediate step a ½ scale ITER source went into operation at the IPP test facility ELISE with the first plasma in February 2013. The experience and results gained so far at ELISE allowed a size scaling study from the prototype source towards the ITER relevant size at ELISE, in which operational issues, physical aspects and the source performance is addressed, highlighting differences as well as similarities. The most ITER relevant results are: low pressure operation down to 0.2 Pa is possible without problems; the magnetic filter field created by a current in the plasma grid is sufficient to reduce the electron temperature below the target value of 1 eV and to reduce together with the bias applied between the differently shaped bias plate and the plasma grid the amount of co-extracted electrons. An asymmetry of the co-extracted electron currents in the two grid segments is measured, varying strongly with filter field and bias. Contrary to the prototype source, a dedicated plasma drift in vertical direction is not observed. As in the prototype source, the performance in deuterium is limited by the amount of co-extracted electrons in short as well as in long pulse operation. Caesium conditioning is much harder in deuterium than in hydrogen for which fast and reproducible conditioning is achieved. First estimates reveal a caesium consumption comparable to the one in the prototype source despite the large size.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RF H- Ion Source with Saddle Antenna

In this project we are developing an RF H- surface plasma source (SPS) which will synthesize the most important developments in the field of negative ion sources to provide high pulsed and average current, higher brightness, longer lifetime and higher reliability by improving a power efficiency. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in a small AlN test chamber in the SNS ion source Test Stand. Then a prototype saddle antenna was installed in the Test Stand with a larger, normal-sized SNS AlN chamber that achieved a peak current of 67 mA and an apparent efficiency of 1.6 mA/kW. These values are comparable to those of the present SNS sources and can be expected to be improved when the prototype is developed into an operational version in the next phase of the project.

43 PARTICLE ACCELERATORS↗

Computer System for Unattended Control of Negative Ion Source

The computer system for control of cw surface-plasma source of negative ions is described. The system provides an automatic handling of source parameters by the specified scenario. It includes the automatic source start and long-term operation with switching and control of the power supplies blocks, setting and reading of source parameters like hydrogen feed, cesium seed, electrodes' temperature, checking of the protection and blockings elements like vacuum degradation, absence of cooling water, etc. The semi-automatic mode of control is also available, where the order of steps and magnitude of parameters, included to scenario, is corrected in situ by the operator. Control system includes the main controller and a set of peripheral local controllers. Commands execution is carried out by the main controller. Each peripheral controller is driven by the stand-alone program, stored in its ROM. Control system is handled from PC via Ethernet. The PC and controllers are connected by fiber optic lines, which provide the high voltage insulation and the stable system operation in spite the breakdowns and electromagnetic noise of cross-field discharge. The PC program for data setting and information display is developed under the LabView.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 2.45 GHz electron cyclotron resonance proton ion source and a dual-lens low energy beam transport

The structure and preliminary commissioning results of a new 2.45 GHz ECR proton ion source and a dual-lens low energy beam transport (LEBT) system are presented in this paper. The main magnetic field of the ion source is provided by a set of permanent magnets with two small electro-solenoid magnets at the injection and the extraction to fine tune the magnetic field for better microwave coupling. A 50 keV pulsed proton beam extracted by a three-electrode mechanism passes through the LEBT system of length of 1183 mm. This LEBT consists of a diagnosis chamber, two Glaser lenses, two steering magnets, and a final beam defining cone. A set of inner permanent magnetic rings is embedded in each of the two Glaser lenses to produce a flatter axial-field to reduce the lens aberrations.

43 PARTICLE ACCELERATORS↗

Rod-filter-field optimization of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second-stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). Although rod-filter-field (RFF) is indispensable and one of the most beam performance dominative parameters for the RF-driven H{sup −} ion source with the internal-antenna, the procedure to optimize it is not established. In order to optimize the RFF and establish the procedure, the beam performances of the J-PARC source with various types of rod-filter-magnets (RFMs) were measured. By changing RFM’s gap length and gap number inside of the region projecting the antenna inner-diameter along the beam axis, the dependence of the H{sup −} ion beam intensity on the net 2MHz-RF power was optimized. Furthermore, the fine-tuning of RFM’s cross-section (magnetmotive force) was indispensable for easy operation with the temperature (T{sub PE}) of the plasma electrode (PE) lower than 70°C, which minimizes the transverse emittances. The 5% reduction of RFM’s cross-section decreased the time-constant to recover the cesium effects after an slightly excessive cesiation on the PE from several 10 minutes to several minutes for T{sub PE} around 60°C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hollow metal target magnetron sputter type radio frequency ion source

A 70 mm diameter 70 mm long compact ion source equipped with a hollow sputtering target has been designed and tested. The hollow sputtering target serves as the radio frequency (RF) plasma excitation electrode at 13.56 MHz. A stable beam of Cu{sup +} has been extracted when Ar was used as the discharge support gas. In the extracted beam, Cu{sup +} had occupied more than 85% of the total ion current. Further increase in Cu{sup +} ions in the beam is anticipated by increasing the RF power and Ar pressure.

36 MATERIALS SCIENCE↗

Model for the description of ion beam extraction from electron cyclotron resonance ion sources

The finite difference method trajectory code KOBRA3-INP has been developed now for 25 years to perform the simulation of ion beam extraction in three dimensions. Meanwhile, the code has been validated for different applications: high current ion beam extraction from plasma sources for ion implantation technology, neutral gas heating in fusion devices, or ion thrusters for space propulsion. One major issue of the development of this code was to improve the flexibility of the applied model for the simulation of different types of particle sources. Fixed emitter sources might be simulated with that code as well as laser ion sources, Penning ion sources, electron cyclotron resonance ion sources (ECRISs), or H{sup -} sources, which require the simulation of negative ions, negative electrons, and positive charges simultaneously. The model which has been developed for ECRIS has now been used to explore the conditions for the ion beam extraction from a still nonexisting ion source, a so called ARC-ECRIS [P. Suominen and F. Wenander, Rev. Sci. Instrum. 79, 02A305 (2008)]. It has to be shown whether the plasma generator has similar properties like regular ECRIS. However, the emittance of the extracted beam seems to be much better compared to an ECRIS equipped with a hexapole.

43 PARTICLE ACCELERATORS↗

Concepts of magnetic filter fields in powerful negative ion sources for fusion

The performance of large negative ion sources used in neutral beam injection systems is in long pulses mainly determined by the increase of the currents of co-extracted electrons. This is in particular a problem in deuterium and limits the ion currents which are for long pulses below the requirements for the ITER source. In the source of the ELISE test facility, the magnetic field in front of the first grid, which is essential to reduce the electron current, is generated by a current of several kA flowing through the plasma facing grid. Weakening of this field by the addition of permanent magnets placed close to the lateral walls has led to a reduction of the electron current by a factor three without loss of ion current when source was operated in volume production. If this effect can be validated for the cesiated source, it would be a large step towards achieving the ITER parameter in long pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time evolution of negative ion profile in a large cesiated negative ion source applicable to fusion reactors

To understand the physics of the cesium (Cs) recycling in the large Cs-seeded negative ion sources relevant to ITER and JT-60SA with ion extraction area of 45-60 cm × 110-120 cm, the time evolution of the negative ion profile was precisely measured in JT-60SA where the ion extraction area is longitudinally segmented into 5. The Cs was seeded from the oven at 180 °C to the ion source. After 1 g of Cs input, surface production of the negative ions appeared only in the central segment where a Cs nozzle was located. Up to 2 g of Cs, the negative ion profile was longitudinally expanded over full ion extraction area. The measured time evolution of the negative ion profile has the similar tendency of distribution of the Cs atoms that is calculated. From the results, it is suggested that Cs atom distribution is correlated with the formation of the negative ion profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗