Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Photon counting detectors for Fabry-Perot interferometers

Sealed channel plate photomultipliers with multiple discrete anodes for use as photon counting detectors in the image plane of Fabry-Perot interferometers are described. The influence of design and construction on performance of completed devices is discussed. Effects on spatial resolution, lifetime, and counting efficiency are described. It is shown that devices can be optimized for particular applications. The results should be generally applicable to resistive anode and wedge and strip anode types of sealed detectors.

Darlington, E. H.↗

Optical interferometers for tests of relativistic gravity in space

A space-based astrometric interferometer with a large optical bandwidth is considered. POINTS (Precision Optical INTerferometry in Space) would measure the angular separation of two stars separated by about 90 deg on the sky with a nominal measurement error of 5 microarcseconds (mas). For a pair of mag 10 stars, the observation would require about 10 minutes. It is estimated that the instrument would measure daily the separation of two stars for each of about 60 pairs of stars; a random sequence of such measurements, if suitably redundant, contains the closure information necessary to detect and correct time dependent measurement biases to well below the nominal measurement accuracy. The 90 deg target separation permits absolute parallax measurements in all directions. A redundant observing schedule for 300 stars and 5 quasars would provide extra redundancy to compensate for the quasars' higher magnitude. If a nominal 30-day observation sequence were repeated 4 times per year for 10 years, stellar parameter uncertainties would be obtained of: 0.6 mas, position; 0.4 mas/y, proper motion; and 0.4 mas, parallax. This set of well-observed stars and quasars would form a rigid frame and the stars would serve as reference objects for measurements of all additional targets, as well as being targets of direct scientific interest. The instrument global data analysis since objectives are considered including a relativity test and technology.

Reasenberg, R. D.↗

Galileo Earth approach navigation using connected-element interferometer phase-delay tracking

The application of a Connected-Element Interferometer (CEI) to the navigation of the Galileo spacecraft during its encounter with Earth in December 1990 is investigated. A CEI tracking demonstration is planned for the week of November 11 through 18, 1990, from 27 days to 20 days prior to Earth encounter on December 8. During this period, the spacecraft will be tracked daily with Deep Space Network Stations 13 and 15 at Goldstone. The purpose of this work is twofold: first, to establish and define the navigation performance expected during the tracking demonstration and, second, to study, in a more general sense, the sensitivity of orbit demonstration results obtained with CEI to the data density within CEI tracking passes and to important system parameters, such as baseline orientation errors and the phase-delay measurement accuracy. Computer simulation results indicate that the use of CEI data, coupled with conventional range and Doppler data, may reduce the uncertainty in the declination of the spacecraft's incoming trajectory by 15 to 66 percent compared with the operational solution using range and Doppler data only. The level of improvement depends upon the quantity and quality of the CEI data.

Thurman, S. W.↗

Analysis of cirrus optical properties with data from NASA ER2 High-resolution Interferometer Sounder (HIS)

The 8 to 13 micron spectral region is an important atmospheric window for radiometric studies of the Earth's surface and clouds. Most of the Earth-atmosphere longwave radiative loss to space occurs in this spectral region. Selective gaseous absorption in this window occurs in the 9.6 micron ozone band with the remaining absorption dominated by the water vapor continuum. Cirrus clouds have a large impact on the transmittance of this atmospheric window region; it is therefore important to understand the interaction of cirrus cloud with the radiation field for climate studies and in the interpretation of satellite radiometric measurements. The focus was to employ observations of the High-resolution Interferometer Sounder (HIS) made during First ISCCP Regional Experiment (FIRE) to improve the understanding of the radiative properties of cirrus clouds within this window region. Studies were undertaken to investigate the coupling between the microphysical properties of cirrus clouds and their spectral variation within this window region. Extensions of the HIS studies to satellite measurements, with regards to remote sensing and interpretation, were also investigated.

Smith, William L.↗

Apparent orbit of the spectroscopic binary Beta Arietis with the time Mark III Stellar Interferometer

The spectroscopic binary Beta Ari has been directly resolved with the Mark III Stellar Interferometer. Observations in 1988 were analyzed to determine the visual orbit of the system with the following results: eccentricity = 0.903 +/- 0.012, semimajor axis = 0.0361 +/- 0.0003 arcsec, inclination = 44.7 +/- 1.3 deg, longitude of periastron = 209.1 deg +/- 1.2 deg, position angle of ascending node = 79.1 deg +/- 0.8 deg. The measured magnitude difference between two components, Delta m = 2.63 +/- 0.22 at 800 nm, yields individual visual magnitudes of m(v1) = 2.70 +/- 0.02 and m(v2) = 5.80 +/- 0.20. Combined with data from spectroscopic observations, masses M1 = (2.34 +/- 0.10) solar masses, M2 = (1.34 +/- 0.07) solar masses, and geometrical parallax pi = 0.053 arcsec +/- 0.002 arcsec are derived. These results demonstrate that both components of Beta Ari agree well with the empirical mass-luminosity relation.

Pan, X. P.↗

Fabry-Perot interferometer development for rocket engine plume spectroscopy

This paper describes a new rugged high-resolution Fabry-Perot interferometer (FPI) designed for rocket engine plume spectroscopy, which is capable of detecting spectral signatures of eroding engine components during rocket engine tests and/or flight operations. The FPI system will make it possible to predict and to respond to the incipient rocket engine failures and to indicate the presence of rocket components degradation. The design diagram of the FPI spectrometer is presented.

Bickford, R. L.↗

Point-Diffraction Interferometer For Flow Experiments

Improved point-diffraction interferometer used in both real-time visualization and recording of supersonic and transonic flow fields about airfoils and other test bodies in wind tunnels. System relatively insensitive to vibrations, but very sensitive to optical quality of wind-tunnel windows. Designed to handle higher laser powers and to use available light efficiently.

Bachalo, William D.↗

Broadband, Achromatic Twyman-Green Interferometer

Improved Twyman-Green interferometer used in wave-front testing optical components at wavelengths from 200 to 1,100 nm, without having to readjust focus when changing wavelength. Built to measure aberrations of light passing through optical filters. Collimating and imaging lenses of classical Twyman-Green configuration replaced by single spherical mirror. Field lens replaced by field mirror. Mirrors exhibit no axial chromatic aberration and made to reflect light efficiently over desired broad range of wavelengths.

Steimle, Lawrence J.↗

Development of an optical fiber interferometer for detection of surface flaws in aluminum

The main objective was to demonstrate the potential of using an optical fiber interferometer (OFI) to detect surface flaws in aluminum samples. Standard ultrasonic excitation was used to generate Rayleigh surface waves. After the waves interacted with a defect, the modified responses were detected using the OFI and the results were analyzed for time-of-flight and frequency content to predict the size and location of the flaws.

Gilbert, John A.↗

Remote sensing of Earth's atmosphere and surface using a digital array scanned interferometer: A new type of imaging spectrometer

The capabilities of the digital array scanned interferometer (DASI) class of instruments for measuring terrestrial radiation fields over the visible to mid-infrared are evaluated. DASI's are capable of high throughput, sensitivity and spectral resolution and have the potential for field-of-view spatial discrimination (an imaging spectrometer). The simplicity of design and operation of DASI's make them particularly suitable for field and airborne platform based remote sensing. The long term objective is to produce a versatile field instrument which may be applied toward a variety of atmospheric and surface studies. The operation of DASI and its advantages over other spectrometers are discussed.

Hammer, Philip D.↗

Wide-angle astrometry with the Mark III stellar interferometer

Astrometric measurements made with the Mark III stellar interferometer on five nights in August-September 1988 yielded average formal 1-sigma errors for 12 FK5 stars of 6 mas in declination and 10 mas in right ascension. This improvement in precision over previously reported measurements with this instrument made in 1986 is attributable to several factors: a second 12 m baseline; oriented E-S, was added to the instrument to improve the determination of right ascension; two-color analysis was included in the data-reduction process, along with a new central-fringe identification algorithm using three spectral channels, in order to reduce atmospheric errors; thermal control was greatly improved; and changes were made to observational procedures and hardware to monitor variations in the delay offset due to residual thermal drifts. Approximately half of the new positions are within 50 mas of their FK5 positions. However, an extended series of measurements are needed to ascertain the accuracy that can be achieved by interferometry.

Shao, M.↗

Measurement of birefringence of optical materials using a wedged plate interferometer

A nondestructive technique for measuring the birefringence of optical materials such as calcite using wedged plate interferometer is presented. The sample needed for measuring the refractive index must be polished in the form of a parallel plate. The method is based on the measurement of the longitudinal displacement of the focus when the parallel plate is inserted in a converging beam of light. The displacement of the focus is a measure of the refractive index of the optical material. In the case of a uniaxial crystal, the displacement of the focus for the extraordinary ray is different from the displacement of the focus for the ordinary ray. Hence the birefringence of the crystal is determined by measuring the difference between the two focii. It is possible to obtain an accuracy up to 0.0002 in the measurement of birefringence depending on the sample thickness. The method should find its application for the characterization of new crystals in various material research and crystal growth laboratories.

Shukla, R. P.↗

Long-term stability of a Fabry-Perot interferometer used for measurement of stellar Doppler shift

The use of a fiber-optic-link CCD-detector Fabry-Perot interferometer (McMillan et al., 1985, 1986, and 1988) to obtain high-accuracy measurements of stellar Doppler shifts at KPNO is described in detail and illustrated with sample data. Particular attention is given to accuracy requirements and techniques for reducing errors, resolution (orders of 50 mA at wavelength 4300 A are separated by 640 mA), CCD sensitivity, observing and data-processing operations, and the control of environmental conditions. Standard-deviation data and statistics on seven solar-type stars are presented in tables, and the time evolution of the radial velocity of Beta Com is shown in a graph.

Mcmillan, R. S.↗

Development of a Fabry-Perot interferometer for rocket engine plume monitoring

The development of a lightweight, compact, high-resolution Fabry-Perot interferometer (FPI) based spectrometer capable of detecting the spectral signatures of eroding engine components during test and/or flight operations is discussed. FPI based spectrometers will be designed to be smaller and lighter than grating or prism type devices and to provide greater wavelength resolving capability. The FPI system seeks to combine the features of high line resolution, active background discrimination, smart digital signal processing, and rocket engine flight capability. The design, fabrication, and test of a breadboard FPI spectrometer have been completed and the breadboard instrument has clearly demonstrated the viability of the approach. The breadboard instrument design and test results are also presented.

Bickford, R. L.↗

Optical observations of close binaries with the Mark III Stellar Interferometer

For the first time, four spectroscopic binaries have been directly resolved with the Mark III Stellar Interferometer. Observations in 1988 and 1989 were analyzed, and visual orbits for four binaries have been determined. The semimajor axes for Beta Tri, Alpha Equ, Alpha And and Beta Ari are approximately 0.008 arcsec, 0.012 arcsec, 0.024 arcsec and 0.037 arcsec, respectively. The magnitude differences between two components are 0.5, 0.7, 1.8 and 2.6 mag, respectively. All of the orbital elements for Alpha And and Beta Ari were determined from interferometric data only, and agree well with spectroscopic observations. Predictions of relative position between the two components for these binaries are consistent with the measurements to less than 0.001 arcsec. Combined with data from spectroscopy, masses and distance for the double-lined spectroscopic binary Beta Ari are derived, and the results indicate that both components of Beta Ari agree well with the empirical mass-luminosity relation.

Pan, X. P.↗

The MPE/UCB far-infrared imaging Fabry-Perot interferometer (FIFI)

FIFI, an imaging spectrometer with two or three Fabry-Perot interferometers in a series for astronomical observations in the FIR range, is described. Spectral resolutions of 2 km/s can be obtained with FIFI. Design considerations are discussed as well as optics, the detector array, the transimpedance amplifier array, signal demodulation, data acquisition, and instrument control.

Poglitsch, A.↗

Squeezed pulsed light from a fiber ring interferometer

Observation of squeezed noise, 5 +/- 0.3 dB below the shot noise level, generated with pulses in a fiber ring interferometer is reported. The interferometric geometry is used to separate the pump pulse from the squeezed vacuum radiation. A portion of the pump is reused as the local oscillator in a homodyne detection. The pump fluctuations are successfully subtracted and shot noise limited performance is achieved at low frequencies (35-85 KHz). A possible utilization of the generated squeezed vacuum in improving a fiber gyro's signal to noise ratio is discussed.

Bergman, K.↗

WAMDII: The Wide Angle Michelson Doppler Imaging Interferometer

As part of an effort to learn more about the upper atmosphere and how it is linked to the weather experienced each day, NASA and NRCC are jointly sponsoring the Wide Angle Michelson Doppler Imaging Interferometer (WAMDII) Mission. WAMDII will measure atmospheric temperature and wind speed in the upper atmosphere. In addition to providing data on the upper atmosphere, the wind speed and temperature readings WAMDII takes will also be highly useful in developing and updating computer simulated models of the upper atmosphere. These models are used in the design and testing of equipment and software for Shuttles, satellites, and reentry vehicles. In making its wind speed and temperature measurements, WAMDII examines the Earth's airglow, a faint photochemical luminescence caused by the influx of solar ultraviolet energy into the upper atmosphere. During periods of high solar flare activity, the amount of this UV energy entering the upper atmosphere increases, and this increase may effect airglow emissions.

Source record↗