Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Coverage Status of the ARC Code PERSENT

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. PERSENT fulfills the role of generating reactivity coefficients for a given time point of a REBUS calculation usable in a point kinetics based safety analysis capability. PERSENT also provides a sensitivity coefficient capability on eigenvalue, reactivity worth, and several other key coefficients that are used in the follow-on safety analysis. Given a co-variance matrix, PERSENT can carry out the uncertainty quantification to indicate the amount of error in the reactivity coefficients derived from the errors in the cross section measurements. With continued improvement of computational resources, many of the geometry modeling capabilities in DIF3D that were primarily used in low order schemes are not really needed anymore. Today, the diffusion and transport capabilities of DIF3D-VARIANT are primarily used in the reactor design process with some scattered usage of DIF3D-FD and DIF3D-Nodal. PERSENT is part of the ARC code system and is built around DIF3D-VARIANT and the flux solution it provides. The purpose of the present work is to identify a set of test problems for PERSENT and assess the code coverage of PERSENT for those test problems. PERSENT treats the DIF3D executable as an external executable and thus the code coverage considerations only need to focus on the PERSENT source code and only a fraction of the connected modules in the existing ARC software library. The goal is to document what parts of the existing PERSENT code are touched by the set of test problems and which are not. Because the verification work done on PERSENT was focused on the most common uses of PERSENT for fast reactor analysis, the code coverage assessment of those capabilities is the highest priority. This will ensure that nothing is being missed by the existing verification test problems that users of PERSENT rely upon. The code coverage analysis of PERSENT was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of PERSENT. The detailed coverage tables are given for each submodule of PERSENT. Most of the uncovered parts/files could be easily ignored because they are either for error message and debugging output or not needed by PERSENT today. Only a few uncovered parts of PERSENT deserve extending the verification test suite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

West Valley Demonstration Project (WVDP) (Annual Site Environmental Report (ASER), Calendar Year 2022)

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2022. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2022 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First-Principles Cost Estimation of a Sodium Fast Reactor Nuclear Plant

A multi-tiered cost analysis is performed to estimate full costs of a nuclear power plant (NPP) based on sodium-cooled fast reactor (SFR) technology. To address the lack of fully transparent cost estimations from past undertakings for NPPs, we have developed a detailed and first-principles-based cost estimate for a generalized SFR NPP. Our intent is to achieve a high degree of transparency with our cost assumptions and develop a cost model that is flexible and easily extendable to variations in NPP design and other nuclear reactor types. Furthermore, we strive to achieve a clear organization of costs and complete identification of key cost drivers based on first principles. To this end, the cost results of our analysis as given in Table 24 and Table 25 are organized and categorized into a code of accounts (COA) under development at Idaho National Laboratory (INL). Varying degrees of first-principles methods are employed, such as design for manufacture and assembly® (DFMA® ), to elucidate costs in all process levels of the plant equipment, buildings and site structures, personnel, and other miscellaneous but significant cost elements. These approaches have been successfully applied in past cost analysis projects and are designed to enable rapid and flexible cost estimation. Application of these techniques for evaluating NPP costs is similar in concept to the full, detailed estimation of construction and fabrication costs determined in a later stage of NPP development. Note that our approach tries to avoid use of other past analysis results and data such as those from the legacy Energy Economic Data Base (EEDB) Program, as these resources are based on historical NPP costs and thus may not be indicative of new reactor technologies or construction and fabrication/manufacturing techniques. However, we provide a comparison of our SFR NPP cost results in Table 90 against those included in the EEDB for a representative pressurized water reactor (PWR).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2023

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2023. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2023 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

Record of Decision↗

Non-invasive characterization of complex coronary lesions

Conventional invasive diagnostic imaging techniques do not adequately resolve complex Type B and C coronary lesions, which present unique challenges, require personalized treatment and result in worsened patient outcomes. These lesions are often excluded from large-scale non-invasive clinical trials and there does not exist a validated approach to characterize hemodynamic quantities and guide percutaneous intervention for such lesions. This work identifies key biomarkers that differentiate complex Type B and C lesions from simple Type A lesions by introducing and validating a coronary angiography-based computational fluid dynamic (CFD-CA) framework for intracoronary assessment in complex lesions at ultrahigh resolution. Among 14 patients selected in this study, 7 patients with Type B and C lesions were included in the complex lesion group including ostial, bifurcation, serial lesions and lesion where flow was supplied by collateral bed. Simple lesion group included 7 patients with lesions that were discrete, <10mm long and readily accessible. Intracoronary assessment was performed using CFD-CA framework and validated by comparing to clinically measured pressure-based index, such as FFR. Local pressure, endothelial shear stress (ESS) and velocity profiles were derived for all patients. We validates the accuracy of our CFD-CA framework and report excellent agreement with invasive measurements (n=14,R 2 =0.6,p=0.0013). Ultra-high resolution achieved by the model enable physiological assessment in complex lesions and quantify hemodynamic metrics in all vessels up to 1mm in diameter. Importantly, we demonstrate that in contrast to traditional pressure-based metrics, there is a significant difference in the intracoronary hemodynamic forces, such as ESS, in complex lesions compared to simple lesions at both resting and hyperemic physiological states [n = 14, p=0.03]. Higher ESS was observed in the complex lesion group (7.0±4.7 Pa) than in simple lesion group (4.8±3.6 Pa). Complex coronary lesions have higher ESS compared to simple lesions, such differential hemodynamic evaluation can provide much the needed insight into the increase in adverse outcomes for such patients and has incremental prognostic value over traditional pressure-based indices, such as FFR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen adsorption and transport in clay-rich geomaterials: Implications for large-volume underground hydrogen storage

Depleted oil and gas reservoirs, characterized by impermeable clay-rich caprocks, are promising sites for large-scale underground hydrogen storage (UHS), which is a key strategy to support hydrogen-based energy systems. However, experimental data on hydrogen storage in clay-rich geomaterials remain scarce. In this work, we experimentally investigated hydrogen adsorption and migration in clay-rich geomaterials in the presence of nitrogen and water under controlled temperatures. Experimental observations showed that hydrogen was adsorbed in dry illite. A dual-porosity transport model was developed to interpret hydrogen transport between large-pore and small-pore domains in illite. The large-pore domain is the space between clay particles (i.e., inter-particle space), whereas the small-pore domain is the nanoscale pore space between clay mineral layers (i.e., inter-layer or intra-particle space). In contrast, nitrogen showed no evidence of adsorption in dry illite because it cannot move into the small-pore domain due to the relatively large kinetic diameter, referred to as the molecular sieving effect. Here, we found that 0.7–1.3 nm is the length scale regulating this molecular sieving effect, matching the interlayer spacing in illite, suggesting that nitrogen is a promising cushion gas in UHS, which aims to maintain adequate pressure in the reservoir for economic operations. In wetted illite, hydrogen was not adsorbed into the interlayer space due to the occupation of adsorption sites by interlayer water, which highlights the critical role of the clay hydration state in controlling hydrogen-clay interactions. Additionally, hydrogen adsorption experiments on crushed shale indicated that the shale surface possessed adsorption sites more favorable for hydrogen than for nitrogen. Through these experiments, we provide new insights into hydrogen storage mechanisms in clay-rich geomaterials and offer valuable laboratory data for evaluating the performance of large-scale UHS systems.

Adsorption↗

Automated, Unmanned Detection and Quantification of Fugitive Methane Emissions

Compressor stations used to move natural gas are one of the largest sources of fugitive methane emissions in the midstream sector, accounting for approximately 50% of all fugitive emissions (Zimmerle et al., 2015). This problem is most widespread at reciprocating compressors (Subramanian et al., 2015) where faulty seals are a key contributor to methane emissions (Johnson et al., 2015). As such, there is a significant need for a robust technology that could provide an early indication of an unexpected emission. Equally important, the technology needs to be able to account for biogenic versus anthropogenic sources of methane. One means of indirectly making this determination, is to leverage optical technologies that can autonomously pinpoint the source of such leaks. This presentation discusses recent work funded by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), focused on the development of an innovative remote sensing technology that can reliably and autonomously detect fugitive methane emissions in near real-time, using computer vision and deep learning. The technology called the Smart Methane Leak Detection (SLED/M) system was initially developed to monitor facilities such as compressor stations in a stationary, pan-tilt-zoom configuration. The system has recently been adapted to monitor facilities from an unmanned aerial system (UAS). The speed and maneuverability of UAS platforms are attractive to leak detection and repair program operators, but introduce several challenges. Many existing methane detection algorithms rely on mostly static backgrounds becoming unusable with motion. In addition, top-down views of fugitive methane emissions present differently in Optical Gas Imagers (OGI) compared to looking across the plume. Our work has focused on overcoming these challenges, enhancing the operators ability to detect methane emissions, and pinpoint their sources. Another recent adaptation to SLED/M is the ability to quantify methane emissions using passive sensors (OGI, thermal camera), environmental conditions, plume modeling, and deep learning. SLED/M advances the state-of-the-art for methane emission detection and quantification by focusing on three key critical criteria for effective methane emission mitigation: (1) autonomy (no need for a human to be in the loop), (2) high reliability (low false alarm rates), and (3) real-time performance. Results from this work will be presented.

03 NATURAL GAS↗

Passivated Contacts for Direct Wafer Product (Final Technical Report)

This TCF project developed a thin-oxide (SiO 2 )/polycrystalline silicon (poly-Si) passivated contact solar cell on CubicPV's (formally 1366 Technologies, Inc.) Direct Wafer® Product (DWP) kerfless wafers. The project used two NREL-developed technologies described in U.S. Patent No. 9,911,873, Hydrogenation of Passivated Contacts and U.S. Patent Application Serial No. 15/890,172, Doped Passivated Contacts . The project was motivated by a potential higher efficiency cell (compared to a PERC cell) using passivated contacts on the ultra-low cost kerfless wafers grown using the Direct Wafer process. The hope was to accelerate market adoption of the cell and wafer by delivering the lowest LCOE in the PV industry. The project tested both n-type and p-type SiO 2 /poly-Si passivated contacts grown by thermal oxidation and plasma enhanced chemical vapor deposition (PECVD) of the poly-Si layer on DWP with varying wafer resistivities. Both deposition techniques are industry standards and thus economically viable methods for commercializing the contacts. The results indicated that both n-type and p-type poly-Si passivated contacts can be formed on polycrystalline DWP wafers, but implied open-circuit voltages (i Voc ) were limited to below 0.65 mV (compared with ~ 730 mV on n-Cz wafers). Diffusion of H to the Si/SiO 2 /poly-Si interface was key to obtaining high i Voc values. In this study, H was diffused from a high-temperature SiN x layer deposited over the poly-Si layer during a high-temperature firing step, similar to one used for screen printed metals. The study concluded that poly-Si passivated contacts on DWP wafers passivated the surface of the wafers as well as PERC passivated surfaces, which use a less expensive dielectric layer stack. The project showed that Direct Wafer Product wafers grown by CubicPV could produce high i Voc values (~0.647 mV), which could produce a cell over 20% efficient with proper processing and metallization. These cells, though not economically viable in 2024 as a stand-alone cell, could be integrated with a wide-bandgap top solar cell to form a two-junction tandem cell that could be viable under certain circumstances. This is because the bottom cell of a 30%, two-terminal tandem only needs to be a 20% cell under one-sun conditions. Thus, the DWP could be an ideal low-cost wafer for tandems. The project also revealed that a TOPCon type cell could be formed on a p-type DWP wafer using a P-diffused emitter and a p-type poly-Si contact. In fact, the p-type version of the poly-Si contact out-performed the n-type version for a variety of wafer resistivities, from highly doped to lowly doped. This curiosity requires more work to understand because on Cz wafers, the n-type poly-Si contact is of much higher quality than the p-type version.

14 SOLAR ENERGY↗

A daily, 250 m and real-time gross primary productivity product (2000–present) covering the contiguous United States

Abstract. Gross primary productivity (GPP) quantifies the amount of carbon dioxide (CO2) fixed by plants through photosynthesis. Although as a key quantity of terrestrial ecosystems, there is a lack of high-spatial-and-temporal-resolution, real-time and observation-based GPP products. To address this critical gap, here we leverage a state-of-the-art vegetation index, near-infrared reflectance of vegetation (NIRV), along with accurate photosynthetically active radiation (PAR), to produce a SatelLite Only Photosynthesis Estimation (SLOPE) GPP product for the contiguous United States (CONUS). Compared to existing GPP products, the proposed SLOPE product is advanced in its spatial resolution (250 m versus >500 m), temporal resolution (daily versus 8 d), instantaneity (latency of 1 d versus >2 weeks) and quantitative uncertainty (on a per-pixel and daily basis versus no uncertainty information available). These characteristics are achieved because of several technical innovations employed in this study: (1) SLOPE couples machine learning models with MODIS atmosphere and land products to accurately estimate PAR. (2) SLOPE couples highly efficient and pragmatic gap-filling and filtering algorithms with surface reflectance acquired by both Terra and Aqua MODIS satellites to derive a soil-adjusted NIRV (SANIRV) dataset. (3) SLOPE couples a temporal pattern recognition approach with a long-term Cropland Data Layer (CDL) product to predict dynamic C4 crop fraction. Through developing a parsimonious model with only two slope parameters, the proposed SLOPE product explains 85 % of the spatial and temporal variations in GPP acquired from 49 AmeriFlux eddy-covariance sites (324 site years), with a root-mean-square error (RMSE) of 1.63 gC m−2 d−1. The median R2 over C3 and C4 crop sites reaches 0.87 and 0.94, respectively, indicating great potentials for monitoring crops, in particular bioenergy crops, at the field level. With such a satisfactory performance and its distinct characteristics in spatiotemporal resolution and instantaneity, the proposed SLOPE GPP product is promising for biological and environmental research, carbon cycle research, and a broad range of real-time applications at the regional scale. The archived dataset is available at https://doi.org/10.3334/ORNLDAAC/1786 (download page: https://daac.ornl.gov/daacdata/cms/SLOPE_GPP_CONUS/data/, last access: 20 January 2021) (Jiang and Guan, 2020), and the real-time dataset is available upon request.

54 ENVIRONMENTAL SCIENCES↗

A Deep Learning Pipeline for Optimizing Large-scale Phase Field Simulations

Phase field (PF) simulations are computationally expensive but remain a key analysis tool to understand the complex mechanisms of additive manufacturing (AM) processes. Each PF simulation-aided analysis requires thousands of node hours on leadership-class supercomputers. One of the main goals of these analyses is the study of microstructure evolution during the build process which begins with the onset of nucleation. Nucleation occurs under certain thermomechanical conditions which are not known a priori and many PF simulations are required to identify ranges of input thermo-mechanical parameters that can result in the onset of nucleation. Since many of the simulations do not result in nucleation, an analysis campaign often ends up wasting tremendous amounts of precious computing resources executing nucleation-absent simulations. The goal of this work is to design and train deep learning models to inform a PF simulation about the likelihood of the occurrence of nucleation in a future simulation time-step based on the state summary over a finite number of past time-steps of a running simulation. If the prediction determines that the running simulation is unlikely to reach nucleation in the allotted time, then its execution is stopped immediately ultimately resulting in vast reduction in wasted computations when accrued over all the PF simulations typically performed in a single or multiple analysis campaign(s). The paper presents the performance of a machine learning pipeline that uses a convolutional neural network (CNN) model to learn an embedding which is then used with a self-attention network to build a multi-task deep learning model to predict the likelihood of nucleation. The model also predicts the input parameters used in a simulation. Performance is compared with a baseline pipeline that uses an off-the-shelf LeNet-5 model to learn the initial embedding. Despite their smaller size, performance results indicate significant improvement in accuracy of the proposed models compared to the larger baseline models.

Kannan, Ramakrishnan {ramki}↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2021

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2021. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2021 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uranium sorption to organic matter and long-term accumulation in a pristine alpine wetland

Understanding the controls on uranium (U) mobility in the environment is key to improve the management of sites contaminated by U mining activities. Previous research has shown that natural or engineered wetlands are particularly able to scavenge high amounts of U(VI) and U(IV) under noncrystalline forms. However, questions remain on the respective roles of sorption and reduction processes in the removal of U from running waters in wetlands, as well as on the long-term stability of U storage. Here, we performed a series of geochemical, isotopic ($δ$ 238 U, ( 234 U/ 238 U)), microscopic (SEM-EDXS, EPMA) and spectroscopic (µ-XRF, µ-XAS, XANES and EXAFS at the U L 3 and M 4 -edges and Fe K-edge) investigations to determine the modes of U accumulation and assess U mobility in a natural exceptionally U-enriched (up to 5000 µg/g) wetland on the shore of Lake Nègre (Mediterranean Alps, France). Uranium (VI) was largely dominant in the two studied soil cores, except a few samples containing as much as ~50 % U(IV). At the particle scale, U is associated to a variety of organic constituents of the soil matrix with a homogenous oxidation state. Bulk EXAFS spectroscopy at the U L 3 -edge shows that U is mostly mononuclear, with dominant monodentate binding to organic moieties (C neighbors at ~3.45 Å). An additional minor fraction of U under polymeric forms is inferred from wavelet (CCWT) analysis of the EXAFS data. These observations are reinforced by 1 M bicarbonate extractions that result in the dissolution of 82–96 % of total U, including putative polymeric species. At the wetland scale, similar or slightly fractionated isotopic ratios ($δ$ 238 U) between the wetland-feeding creek waters and the wetland soils are observed, supporting the idea that U(VI) sorption on organic matter is the primary U scavenging mechanism. Furthermore, it indicates that partial U(VI) reduction to U(IV) occurs as a second step, after sorption. Analysis of U decay chain disequilibria in the cores as a function of depth suggests that U accumulation in this wetland has lasted for several thousand years. In conclusion, we propose that the wetland acts as an active reactor where U has been massively accumulating for ~14500 years, especially as U(VI) forms associated to organic matter and is further partly exported to the lake through soil erosion.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2020

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2020. The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2020. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2020 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

Resource Conservation and Recovery Act↗

Gravitational-wave signal of a core-collapse supernova explosion of a 15M ⊙ star

In this paper we report on the gravitational-wave signal computed in the context of a three-dimensional simulation of a core-collapse supernova explosion of a 15 M ⊙ star. The simulation was performed with our neutrino hydrodynamics code chimera . We detail the gravitational wave strains as a function of time, for both polarizations, and discuss their physical origins. We also present the corresponding spectral signatures. Gravitational wave emission in our model has two key features: low-frequency emission (less than 200 Hz) emanates from the gain layer as a result of neutrino-driven convection and the standing accretion shock instability (SASI), and high-frequency emission (greater than 600 Hz) emanates from the proto–neutron star due to Ledoux convection within it. The high-frequency emission dominates the gravitational wave emission in our model and emanates largely from the convective layer itself, not from the convectively stable layer above it, due to convective overshoot. Moreover, the low-frequency emission emanates from the gain layer itself, not from the proto–neutron star, due to accretion onto it. We provide evidence of the SASI in our model and demonstrate that the peak of our low-frequency gravitational wave emission spectrum corresponds to it. Given its origin in the gain layer, we classify the SASI emission in our model as p-mode emission and assign a purely acoustic origin, not a vortical–acoustic origin, to it. We compare the results of our three-dimensional model analysis with those obtained from the model’s two-dimensional counterpart and find a significant reduction in the strain amplitudes in the former case, as well as significant reductions in all related quantities. Our dominant proto–neutron star gravitational wave emission is not well characterized by emission from surface g modes, complicating the relationship between peak frequencies observed and the mass and radius of the proto–neutron star expressed by analytic estimates under the assumption of surface g-mode emission. We present our frequency normalized characteristic strain along with the sensitivity curves of current- and next-generation gravitational wave detectors. This simple analysis indicates that the spectrum of gravitational wave emission between approximately 20 Hz and approximately 1 kHz, stemming from neutrino-driven convection, the SASI, accretion onto the proto–neutron star, and proto–neutron star convection, will be accessible for a Galactic event.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving and Understanding the Hydrogen Evolving Activity of a Cobalt Dithiolene Metal–Organic Framework

Despite the promising previous reports on the development of electrocatalytic dithiolene-based metal–organic frameworks (MOFs) for the hydrogen evolution reaction (HER), these materials often display poor reproducibility of the HER performance because of their poor bulk properties upon integration with electrode materials. In this work, we demonstrate an in-depth investigation of the electrocatalytic HER activity of a cobalt 2,3,6,7,10,11-triphenylenehexathiolate (CoTHT) MOF. To enhance the durability and charge transport properties of the constructed CoTHT/electrode architecture, CoTHT is deposited as an ink composite (1) composed of Nafion and carbon black. We leverage here the well-established use of catalyst inks in the literature to increase adhesion of the catalyst to the electrode surface and to improve the overall electrical conductivity of the integrated catalyst/electrode. The utilization of the composite 1 leads to a significant improvement in the overpotential (η) to reach a current density of 10 mA/cm 2 (η = 143 mV) compared to prior reports, resulting in the most active MOF-based electrocatalyst for the HER that contains only earth-abundant elements. Extensive density functional theory (DFT) calculations were applied to understand the structure of CoTHT and the mechanistic pathways of the HER. The computational results suggest that an AB stacking geometry is energetically favorable, where one layer is slipped by 1.6 Å relative to the neighboring one along the a and b vectors. Additionally, the DFT calculations indicate that the catalytic cycle likely involves a Volmer discharge step to generate a cobalt hydride, followed by a Heyrovsky step to form a cobalt–H 2 intermediate, and finally the dissociation of H 2 .

DFT calculations↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2025

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2025. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of the DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, the evaluation of data collected in 2025 continued to indicate that WVDP activities posed no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗