Measuring Irradiance for Bifacial PV Systems

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

bifacial↗

Strategies for microgrid operation under real-world conditions

Microgrids are an increasingly relevant technology for integrating renewable energy sources into electricity systems. Based on a microgrid implementation in California, in this study we investigate microgrid operation under real-world conditions. These conditions have not yet been considered in combination and encompass energy charges, demand charges, export limits, as well as uncertainty about future electricity demand and generation in the microgrid. Under these conditions, we evaluate the performance of two frequently applied groups of strategies for microgrid operation. The first group is composed of proactive strategies that optimize decisions based on forecasts of future electricity generation and demand. The second group includes reactive strategies that make operational decisions based exclusively on the current state of the microgrid. We evaluate the performance of the strategies under varying operational parameters, forecast accuracies, and microgrid configurations—well beyond our Californian showcase. Our results confirm the expectation that proactive strategies outperform reactive ones in the majority of settings. Yet, reactive strategies can perform better under short control intervals or under moderate prediction errors of PV generation or demand. Furthermore, the interplay between real-world conditions and operational strategies reveals several additional insights for research on microgrid operation. First, we find that demand charges and export limits decisively affect microgrid performance. Second, the impact of forecast errors is highly non-linear and non-monotonous. Third, escalating negative interactions between forecast errors and demand charges make proactive strategies benefit from longer control intervals. This result is contrary to existing best practice, which promotes short control intervals to minimize the impact of uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗

Optimal Operation of PV Sources in DC Grids for Improving Technical, Economical, and Environmental Conditions by Using Vortex Search Algorithm and a Matrix Hourly Power Flow

This document presents a master–slave methodology for solving the problem of optimal operation of photovoltaic (PV) distributed generators (DGs) in direct current (DC) networks. This problem was modeled using a nonlinear programming model (NLP) that considers the minimization of three different objective functions in a daily operation of the system. The first one corresponds to the minimization of the total operational cost of the system, including the energy purchasing cost to the conventional generators and maintenance costs of the PV sources; the second objective function corresponds to the reduction of the energy losses associated with the transport of energy in the network, and the third objective function is related to the minimization of the total emissions of CO2 by the conventional generators installed on the DC grid. The minimization of these objective functions is achieved by using a master–slave optimization approach through the application of the Vortex Search algorithm combined with a matrix hourly power flow. To evaluate the effectiveness and robustness of the proposed approach, two test scenarios were used, which correspond to a grid-connected and a standalone network located in two different regions of Colombia. The grid-connected system emulates the behavior of the solar resource and power demand of the city of Medellín-Antioquia, and the standalone network corresponds to an adaptation of the generation and demand curves for the municipality of Capurganá-Choco. A numerical comparison was performed with four optimization methodologies reported in the literature: particle swarm optimization, multiverse optimizer, crow search algorithm, and salp swarm algorithm. The results obtained demonstrate that the proposed optimization approach achieved excellent solutions in terms of response quality, repeatability, and processing times.

14 SOLAR ENERGY↗

Performance analysis of hybrid power configurations: Impact on primary energy intensity, carbon dioxide emissions, and life cycle costs

In this work, utilization of Natural gas and Hydrogen to support current and future building energy needs to offset the total electric demand while improving the grid resiliency and energy efficiency was investigated. Demand side energy management will play an important role in efficiently managing the available energy resources. Performance assessment of different power generation and energy management configurations is presented in this paper. Development of solutions in addressing grid resiliency by providing the ability to design suitable configurations for meeting individual building energy needs is discussed. Primary movers (PM) such as internal combustion engines (ICE) and fuel cells (FC) along with small scale auxiliary renewable energy source such as photovoltaics (PV) were considered. Key attributes of total carbon foot-print, life cycle costs including capital and operational expenditure, electric grid offset or peak shaving capability, thermal energy availability and its further potential to offset total electric demand, and primary energy intensity are analyzed and discussed in detail.

08 HYDROGEN↗

Least-Cost Pathways for India's Electric Power Sector

The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.

14 SOLAR ENERGY↗

Measuring Irradiance for Bifacial PV Systems: Preprint

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Ganged-PV System Evaluation

The following report contains data and data summaries collected for the SkySun LLC elevated Ganged PV arrays. These arrays were fabricated as a series of PV panels in various orientations, suspended by cables, at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL). Starting in February of 2021, Sandia personnel have collected power and accelerometer data for these arrays to assess design and operational efficacy of varying ganged- PV configurations. The purpose of this power data collection was to see how the various array orientations compare in power collection capability depending on the time of day, year, and the specific daily solar direct normal irradiance (DNI). The power data was collected as a measurement of the power output from the various series strings. The project team measured direct current (DC) voltage and current from the respective arrays. The accelerometer data was collected with the purpose of demonstrating potential destructive mode shapes that could take place with each of the arrays when exposed to high winds. This allowed the team to evaluate whether impacts with respect to specific array orientations using suspended cables is a safe design. All data collection was performed during calendar year 2021.

14 SOLAR ENERGY↗

A Two-Stage Approach for PV Inverter Engagement in Power Factor Correction and Voltage Regulation

The rapid integration of distributed energy resources, like solar photovoltaics (PVs), can lead to overvolt-age challenges due to reverse power flow and a noticeable decrease in power factor at the substation interface. While existing literature extensively explores utilizing smart inverter capabilities for reactive power flexibility using a volt-var curve (VVC), obtaining time-varying operating points of such curves in real-time is challenging due to computational demands and communication requirements. Similarly, employing optimization-based approaches for reactive power control and active voltage regulation in large-scale distribution feeders is difficult due to the complexity of the problem and the challenges in effectively engaging customer-owned resources. This paper proposes a two-stage strategy to harness smart inverters for reactive power support. The first stage formulates short-term planning by optimally designing VVCs (on a daily or hourly basis) for large-scale solar PVs based on projected system needs and communicating optimal curves to smart inverters in advance. Subsequently, the second stage employs a transactive-based method to involve customer-owned PVs for reactive power support, effectively enhancing overall system performance and addressing real-time demands. In conclusion, the efficacy of this approach will be demonstrated using real-world distribution circuits provided by Vermont Electric Power Company (VELCO) and Vermont Electric Cooperative (VEC).

Poudel, Shiva [Pacific Northwest National Laborato↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

Decarbonizing all-electric communities via carbon-responsive control of behind-the-meter resources

The progression of electrification in the building and transportation sectors brings new opportunities for energy decarbonization. With higher dependence on the grid power supply, the variation of the grid carbon emission intensity can be utilized to reduce the carbon emissions from the two sectors. Existing coordinated control methods for buildings with distributed energy resources (DERs) either consider electricity price or renewable energy generation as the input signal, or adopt optimization in the decision-making, which is difficult to implement in the real-world environment. This paper aims to propose and validate an easy-to-deploy rule-based carbon responsive control framework that facilitates coordination between all-electric buildings and electric vehicles (EVs). The signals of the grid carbon emission intensity and the local photovoltaics (PV) generation are used for shifting the controllable loads. Extensive simulations were conducted using a model of an all-electric mixed-use community in a cold climate to validate the control performance with metrics such as emissions, energy consumption, peak demand, and EV end-of-day state-of-charge (SOC). Our study identifies that 4.5% to 27.1% of annual emission reduction can be achieved with limited impact on energy costs, peak demand, and thermal comfort. Additionally, up to 32.7% of EV emission reduction can be obtained if the EV owners reduce the target SOC by less than 21.2%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV backsheets survey protocol: A framework for geo-spatial field surveys for bulk material characterization and reliability analysis applied across 41 PV systems

As widespread adoption of photovoltaic (PV) technologies continues, understanding the lifetime of modules is paramount to the viability of the industry as an environmentally conscious alternative to traditional energy generation. Although power degradation can affect the total energy production of a module over its lifetime, module safety failures necessitate the removal of a module leading to a loss of not only the particular asset, but the earning potential of the device. Therefore, it is critical to ensure that the components that provide essential safety functions for PV module operate for their entire rated lifetime. PV backsheets provide necessary electrical insulation to the completed device and failure of this component is cause for a immediate removal of the module. Degradation of the PV module backsheet has led to module safety failures in large-scale installations, costing millions of dollars in damages and lost potential revenue. The spatio-temporal degradation of fielded PV modules is important to study in order to identify which modules within installations are experiencing the greatest exposure conditions and in turn have the highest chance of failure. This paper describes a comprehensive field survey protocol developed for monitoring PV module backsheet performance using solely non-destructive methods in commercial PV fields. The protocol establishes a field naming convention, sampling method, data handling requirements, and measurement procedures. By ensuring consistent data collection practices, the field survey protocol enables research groups to obtain data of uniform quality on backsheet performance over multiple years and locations. In this study, the developed protocol was implemented at forty-one PV sites. Eight different types of airside layer backsheet materials including poly(vinylidene fluoride) (PVDF), acrylic PVDF, poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), fluoroethylene vinyl ether (FEVE), polyethylene naphthalate (PEN), and glass were identified using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The field survey results show that the spatial distribution of degradation indicators are non-uniform within a particular module, individual site, and across site locations. The degradation of PV modules increased in severity for modules mounted at the edge of rows (across a field) and near the junction box (within a module). This study demonstrates the sensitivity of material performance to exposure length across different materials and climates.

14 SOLAR ENERGY↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Perovskite Quantum Dot Solar Cells: Mapping Interfacial Energetics for Improving Charge Separation

Colloidal halide perovskite nanocrystals or quantum dots (QDs) show similar defect tolerance as thin film perovskite materials with added nanoscale phenomena. Perovskite QD solar cells have demonstrated efficiencies of 16.6%, greater than that of any other QD material system. While the efficiency lags behind the best thin-film perovskite devices, these solar cells could have advantages over the thin-film versions in terms of processability, phase stability, and high open-circuit voltages. However, some operating principles behind perovskite quantum dot device stacks and the associated electric field properties are still unknown. Here, we characterize the junction structure within perovskite QD solar cells, by exposing functioning cross-sections and using nanometer-scale Kelvin probe force microscopy to offer insight into the selection and performance of charge selective contacts. We also evaluated various solar cell device architectures with different selective contacts to isolate the role of each junction in device performance. We show that in high-performance n-i-p architectures, both electron- and hole-transport layer (HTL) interfaces possess a strong electric field, but in the case of the inverted p-i-n architecture, we find that high interfacial recombination at the HTL/QD junction is responsible for subpar device performance. Perovskite QD and thin film materials can synergistically be combined to offer more design flexibility in PV devices, and here we demonstrate that the interface between perovskite thin films and QDs are relatively benign and amenable for synergistic device design.

14 SOLAR ENERGY↗

A Comparison of Emerging and Industry Benchmark Photovoltaic Backsheets Between Different Outdoor Locations

Recent interest within the photovoltaic (PV) module industry is largely directed toward enhanced lifetimes in the field, balanced with improved recyclability. Traditionally, fluoropolymer-based backsheets have been used, however, are difficult to recycle. Emerging polyolefin (PO)-based backsheets are more recyclable and can be formulated to be robust. Properties of different fluoropolymer- and non-fluoropolymer-based backsheet coupons and in encapsulated silicon mini modules that have been fielded in Albuquerque, NM and Cocoa, FL are reported here. Seven backsheets were examined: two novel PO's, TPT, APO, PPE, AAA, and KPf. Methods of examination include module electrical performance (I - V flash test), surface morphology (optical microscope and gloss), polymer chemical structure (FTIR), EL imaging, mechanical tensile testing, DC breakdown voltage, DSC (phase transitions), and optical performance (reflectance spectra).

industries↗