Search NASASearch

SEARCH · Search NASA

Results for “Pressure-less spark plasma sintering (PSPS)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

581 records · Page 31

The Aeolus-Earth DWTS Heliophysics Mission

The Aeolus-Earth Mission (DWTS-Helio) is a recently selected NASA Heliophysics investigation that will apply the innovative Doppler Wind Temperature Sounder (DWTS) technique to the Space Atmosphere Interaction Region (SAIR) at ~105-180 km. The technique, invented by Gordley & Marshall (2011), applies the Doppler Scanning with Gas Filter (DSGF) technique using a cryo-cooled MWIR radiometer to view the limb of the atmosphere from LEO (orbital velocity creates the Doppler shifts required by the technique). For this implementation of DWTS, a Nitric Oxide (NO) low pressure gas cell is used. The limb of the atmosphere is observed from a spacecraft at orbital velocity, and as an observed air volume passes through the field of view, this velocity creates a set of Doppler-shifted images. These images are used to create Doppler Integrated Pass (DIP) signals, from which atmospheric temperature and wind profiles are extracted (it may be considered a converse of the successful in-flight calibration of gas cells used for the HALOE instrument). The technique is relative, removing the need for absolute radiances, and the signal-to-noise ratio for this technique is high, resulting in good measurement precision. Different gas cells can be used to create different altitude coverage and may be combined to measure a more continuous altitude range. For example, using a NO cell captures the lower atmosphere from 30-50km as well as the SAIR, while using the 13 isotopologue of CO2 would capture 50-120km. Due to the desired data volume as well as power and thermal considerations, this initial Aeolus-Earth flight will be more suited for a ‘hosted’ payload on an Orbital Maneuvering Vehicle platform instead of the ‘free-flyer’ option originally investigated. Lastly, the technique is sufficiently powerful that a two-channel system could produce full Mars atmosphere data not currently possible.

DWTS

DS-2 Mars Microprobe Battery

In January of 1999 the NM DS-2 Mars microprobe will be launched to impact on Mars in December. The technical objectives of the missions are to demonstrate: key technologies, a passive atmospheric entry, highly integrated microelectronics which can withstand both low temperatures and high decelerations, and the capability to conduct in-situ, surface and subsurface science data acquisition. The scientific objectives are to determine if ice is present below the Martian surface, measure the local atmospheric pressure, characterize the thermal properties of the martian subsurface soil, and to estimate the vertical temperature gradient of the Martian soil. The battery requirements are 2-4 cell batteries, with voltage of 6-14 volts, capacity of 550 mAh at 80C, and 2Ah at 25C, shelf life of 2.5 years, an operating temperature of 60C and below, and the ability to withstand shock impact of 80,000 g's. The technical challenges and the approach is reviewed. The Li-SOCL2 system is reviewed, and graphs showing the current and voltage is displayed, along with the voltage over discharge time. The problems encountered during the testing were: (1) impact sensitivity, (2) cracking of the seals, and (3) delay in voltage. A new design resulted in no problems in the impact testing phase. The corrective actions for the seal problems involved: (1) pre weld fill tube, (2) an improved heat sink during case to cover weld and (3) change the seal dimensions to reduce stress. To correct the voltage delay problem the solutions involved: (1) drying the electrodes to reduce contamination by water, (2) assemblage of the cells within a week of electrode manufacture, (3) ensure electrolyte purity, and (4) provide second depassivation pulse after landing. The conclusions on further testing were that the battery can: (1) withstand anticipated shock of up to 80,000 g, (2) meet the discharge profile post shock at Mars temperatures, (3) meet the required self discharge rate and (4) meet environmental requirements.

Frank, H.

Experimental Studies of Open Rotor Installation Effects

Open rotor propulsion technologies offer an opportunity for reducing fuel burn. At the same time, great challenges arise from this radically different engine architecture in terms of aircraft system integration. The aeroacoustic effects of integration are one of those key challenges and, furthermore, can offer the possibility for total aircraft system noise reduction. The inter-relationship of the aerodynamic and aeroacoustic system integration effects is particularly important to enable future application. An extensive model scale test campaign was conducted to investigate a broad range of these open rotor installation effects for both a conventional and an unconventional airframe. The experimental campaign was conducted in the Boeing Low Speed Aeroacoustic Facility with specially designed modifications for efficient positioning of the open rotor rig relative to the airframe. The airframe was traversed remotely relative to the fixed open rotor rig providing for the investigation of a large number of installation positions. Eight positions around the main wing of the conventional airframe and eleven positions above the hybrid wing body airframe were documented. Other parameters investigated in the test campaign included forward flight simulation Mach number, angle of attack, rotor speed, and airframe control surface deployment. In addition, both airframes were modified for alternate configurations. The conventional airframe was configured with both a T and a U tail while the unconventional hybrid wing body airframe was configured with different vertical control surfaces. An extensive instrumentation package was deployed. The acoustics were documented with a fixed array of far field microphones, a traversing array of in-flow microphones, an out-of-flow traversing phased array, and unsteady pressure transducers mounted flush on the surface of the airframes. In addition, mean flow surveys were measured with an articulating arm traversing system. The flow field surveys were particularly valuable in documenting flow distortion effects for the various installation positions and those created by angle of attack. This presentation will report the key results obtained for open rotor installation effects and discuss future prospects with the perspective of these results.

Michael J Czech

High Sulfur Loading and Capacity Retention in Bilayer Garnet Sulfurized‐Polyacrylonitrile/Lithium‐Metal Batteries with Gel Polymer Electrolytes

The cubic‐garnet (Li 7 La 3 Zr 2 O 12 , LLZO) lithium–sulfur battery shows great promise in the pursuit of achieving high energy densities. The sulfur used in the cathodes is abundant, inexpensive, and possesses high specific capacity. In addition, LLZO displays excellent chemical stability with Li metal; however, the instabilities in the sulfur cathode/LLZO interface can lead to performance degradation that limits the development of these batteries. Therefore, it is critical to resolve these interfacial challenges to achieve stable cycling. Here, an innovative gel polymer buffer layer to stabilize the sulfur cathode/LLZO interface is created. Employing a thin bilayer LLZO (dense/porous) architecture as a solid electrolyte and significantly high sulfur loading of 5.2 mg cm −2 , stable cycling is achieved with a high initial discharge capacity of 1542 mAh g −1 (discharge current density of 0.87 mA cm −2 ) and an average discharge capacity of 1218 mAh g −1 (discharge current density of 1.74 mA cm −2 ) with 80% capacity retention over 265 cycles, at room temperature (22 °C) and without applied pressure. Achieving such stability with high sulfur loading is a major step in the development of potentially commercial garnet lithium–sulfur batteries.

25 ENERGY STORAGE

The first high-redshift cavity power measurements of cool-core galaxy clusters with the International LOFAR Telescope

Radio-mode feedback associated with the active galactic nuclei (AGNs) at the cores of galaxy clusters injects a large amount of energy into the intracluster medium (ICM), offsetting radiative losses through X-ray emission. This mechanism prevents the ICM from rapidly cooling down and fueling extreme starburst activity as it accretes onto the central galaxies, and it is therefore a key ingredient in the evolution of galaxy clusters. However, the influence and mode of feedback at high redshifts (z ∼ 1) remains largely unknown. Low-frequency sub-arcsecond-resolution radio observations taken with the International LOFAR Telescope have demonstrated their ability to assist X-ray observations with constraining the energy output from the AGNs (or “cavity power”) in galaxy clusters, thereby enabling research at higher redshifts than before. In this pilot project, we tested this hybrid method on a high-redshift (0.6 < z < 1.3) sample of 13 galaxy clusters for the first time with the aim of verifying the performance of this method at these redshifts and providing the first estimates of the cavity power associated with the central AGN for a sample of distant clusters. We were able to detect clear radio lobes in three out of 13 galaxy clusters at redshifts of 0.7 < z < 0.9, and we used these detections in combination with ICM pressures surrounding the radio lobes obtained from standard profiles to calculate the corresponding cavity powers of the AGNs. Combining our results with the literature, the current data appear to suggest that the average cavity power peaked at a redshift ofz ∼ 0.4 and slowly decreases toward higher redshifts. However, we require more and tighter constraints on the cavity volume and a better understanding of our observational systematics to confirm any deviation of the cavity power trend from a constant level.

Astronomy & Astrophysics

Revisiting the Soyuz-1 Parachute Failure in the Context of Safety in the Modern Era

The Soyuz‑1 accident remains one of the most consequential parachute related failures in human spaceflight history and provides enduring lessons for modern Entry, Descent, and Landing (EDL) system design. Occurring during the height of the Cold War and the Space Race, the mission unfolded under extraordinary political and schedule pressure as the Soviet Union sought to maintain its early leadership in space achievements following the death of chief designer Sergei Korolev. Despite unresolved propulsion, electrical, and parachute system deficiencies, Soyuz‑1 proceeded to launch and immediately encountered critical inflight anomalies, including a failed solar panel deployment, attitude control issues, and communication dropouts. Upon reentry, a malfunction in the parachute system, driven by a primary main canopy that failed to deploy, and subsequent entanglement of the reserve main canopy with the primary drogue parachute, resulted in insufficient deceleration and the fatal crash of cosmonaut Vladimir Komarov. Subsequent investigations revealed deep rooted cultural and organizational issues within the Soviet space program, including inadequate testing, suppression of dissent, undocumented last minute design changes, and the absence of integrated parachute system verification. More than 200 design flaws were identified after the accident, and firsthand accounts, including those from Yuri Gagarin, highlighted widespread concern prior to launch. Over time, the Soviet program implemented substantial reforms: systematic design corrections, rigorous process documentation, and an extensive series of drop tests that ultimately transformed the Soyuz system into one of the world’s most reliable human-rated return vehicles. This paper examines the technical architecture of the Soyuz‑1 parachute system, reconstructs the likely deployment sequence and failure mechanism, and analyzes the cultural contributors that shaped the accident. The study draws parallels to modern spacecraft parachute development, emphasizing the critical importance of integrated system testing, transparent engineering culture, and continuous hardware surveillance. These lessons remain directly relevant to today’s NASA and Commercial Crew Programs (CCP), where the Government continues to refine its understanding of aggregate risk and strengthen overall astronaut safety in the face of increasingly complex parachute systems.

Aaron L Morris

Influences of Introduced Yttrium Oxide Particles on Superalloy 718

Additive manufacturing has proven useful for introducing oxide particles into superalloys, to provide oxide dispersion strengthening (ODS) at high temperatures. This study screened how such an approach can influence microstructure and failure modes for superalloy 718. The objective of this study was to compare tensile and creep failure modes for additively manufactured superalloy 718 having introduced oxide particles. Fine yttrium-oxide (yttria) particles were introduced into 718 powder using two different powder mixing methods. Additive manufacturing by laser powder bed fusion was then used to prepare specimen blanks for each case, oriented parallel and transverse to the building direction. These were subsequently given consistent stress relief, hot isostatic pressurization, and final heat treatments, then subjected to tensile and creep tests at varied temperatures. Additively manufactured 718 without ODS (“no-ODS”) had nearly equiaxed grains at 50 μm in width. Roll-mixed ODS material had a bimodal grain size distribution, with fine grains at 9 μm and coarse grains at 66 μm in average width. The fine grains were elongated about 5x in the building direction. Acoustic-mixed ODS materials had grains at 10 μm in width that were elongated about 10x in the build direction. Compared to no-ODS, roll-mixed and acoustic mixed ODS materials did not show improved tensile strengths at room temperature, 760 °C, and 1093 °C. The tensile failure strains parallel to the building direction of roll-mixed ODS material were lowest in these tests. Flattened clumps of yttria had formed transverse to the building direction in roll-mixed material, which were easily cracked. Creep rupture response at 760 °C in the building direction was highest for acoustic-mixed material test. Creep tests at 1093 °C showed varied results, with low rupture lives associated with enhanced cavitation at grain boundaries and surface oxidation. Transverse to the building direction, all three materials had low failure strains in tests at 760 °C. The elongated grain boundaries failed readily in all transverse specimens tested at 760 °C and 1093 °C.

oxide dispersion strengthening

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

Working Fluid Characterization and Performance Assessment of Subcritical Organic Rankine Cycles Based on the Lee–Kesler Approach for Energy Recovery

Here, a generalized model using the Lee–Kesler approach based on the corresponding states principle is developed to assess the performance of subcritical Organic Rankine Cycles operating with different working fluids. Each fluid is characterized by five parameters: the acentric factor, critical temperature, critical pressure, molar mass, and the ideal-gas ratio of specific heats at the critical temperature. The model was developed using the compressibility factor modified version of the Benedict–Webb–Rubin equation proposed by Lee and Kesler and the enthalpy and entropy functions to calculate thermodynamic state properties. The model was validated by comparing the results calculated with the model and working fluid thermodynamic properties obtained with the CoolProp database. This comparison was conducted for 91 working fluids, obtaining a relative error below 5% for 88 out of the 91 fluids (∼97%). A generalized parametric study was conducted to determine the influence of the pinch point and each fluid parameter on the performance of Organic Rankine Cycle (ORC) systems. It was found that efficiency increases with critical temperature, ideal-gas ratio of specific heats at the critical temperature, and acentric factor, reaching up to 13%. The developed model enables the evaluation of ORC system performance for existing working fluids. It also allows the formulation and evaluation of new fluids to enhance the performance of the ORC while retrieving energy from any kind of source; and likewise, the methodology can be applied to other power generation cycles.

24 POWER TRANSMISSION AND DISTRIBUTION

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health

Probing the atomic dynamics of ultrafast melting with femtosecond electron diffraction

Melting is an every-day phase transition that is determined by thermodynamic parameters like temperature and pressure. In contrast, ultra-fast melting is governed by the microscopic response to a rapid energy input and, thus, can reveal the strength and dynamics of atomic bonds as well as the energy flow rate to the lattice. Accurately describing these processes remains challenging and requires detailed insights into transient states encountered. Here, we present data from femtosecond electron diffraction measurements that capture the structural evolution of copper during the ultrafast solid-to-liquid phase transformations. At absorbed energy densities 2-4 times the melting threshold, melting begins at the surface slightly below the nominal melting point followed by rapid homogeneous melting throughout the volume. Molecular dynamics simulations reproduce these observations and reveal a weak electron-lattice energy transfer rate for the given experimental conditions. Both simulations and experiments show no indications of rapid lattice collapse when its temperature surpasses proposed limits of superheating, providing evidence that the inherent dynamics limits the speed of disordering in ultrafast melting of metals.

FOS: Physical sciences

Orbital Processing of High-Quality CdTe Compound Semiconductors

CdZnTe crystals were grown in one-g and in micro-g for comparative analysis. The two micro-g crystals were grown in the Crystal Growth Furnace during the First United States Microgravity Laboratory mission (USML-1). The samples were analyzed for chemical homogeneity, structural perfection, and optoelectronic performance (infrared transmission). Fourier Transform Infrared (FTIR) transmission of both ground and flight materials showed that the infrared transmission was close to theoretical, 63% versus 66%, suggesting that the material was close to the stochiometric composition during both the ground and flight experiments. Infrared microscopy confirmed that the principal precipitates were Te and their size (1-10 microns) and density suggested that the primary flight and ground base samples experienced similar cooling rates. Macrosegregation was predicted, using scaling analysis, to be low even in one-g crystals and this was confirmed experimentally, with nearly diffusion controlled growth achieved even in the partial mixing regime on the ground. Radial segregation was monitored in the flight samples and was found to vary with fraction solidified, but was disturbed due to the asymmetric grvitational and thermal fields experienced by the flight samples. The flight samples, however, were found to be much higher in structural perfection than the ground samples produced in the same furnace under identical growth conditions except for the gravitational level. Rocking curve widths were found to be substantially reduced, from 20/35 (one-g) to 9/20 (micro-g) for the best regions of the crystals. The full width at half maximum (FWHM) of 9 arc seconds is as good as the best reported terrestrially for this material. The ground samples were found to have a fully developed mosaic structure consisting of subgrains, whereas the flight sample dislocations were discrete and no mosaic substructure was evident. The defect density was reduced from 50-100,000 (one-g) to 500-25000 EPD (micro-g). These results were confirmed using rocking curve analysis, synchrotron topography, and etch pit analysis. The low dislocation density is thought to have resulted from the near-absence of hydrostatic pressure which allowed the melt to solidify with minimum or no wall contact, resulting in very low stress being exerted on the crystal during growth or during post-solidification cooling.

D J Larson, Jr.

Development of a One-Domain Volume-Averaged Navier–Stokes Solver

The interaction between a high-enthalpy flow and a thermal protection material is inherently multiscale and multiphysics. In conventional aerothermal analyses, the external flow and material response are generally modeled using separate computational domains coupled through boundary conditions at the material surface. Although this approach has supported many practical applications, it requires assumptions about the location and behavior of the interface and may become difficult to apply when material decomposition, internal reactions, and surface recession substantially alter the porous structure. This report presents the development of a one-domain formulation in which the free-fluid and porous-material regions are represented within a single computational domain. The formulation is based on the volume-averaged Navier–Stokes (VANS) equations, derived from the governing equations for reacting, compressible flow and condensed material. Volume averaging transfers the influence of the unresolved material microstructure to the macroscale equations through effective transport properties, interfacial source terms, and dispersion fluxes. Particular attention is given to regions in which porosity and permeability vary rapidly, including the diffuse transition between a porous material and the surrounding fluid. The resulting equations are implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO). The report describes the pressure–velocity coupling strategy used by the solver, examines spatial filtering techniques for deriving effective properties, and evaluates the influence of a smoothly varying interface permeability. Numerical demonstrations include canonical porous-flow configurations, a flow-tube configuration representative of FiberForm® permeability experiments, and the oxidation of a porous carbon material. The purpose of this work is to establish a mathematical and computational foundation for a unified treatment of flow and thermal protection material response. The present formulation is intended to support the progressive inclusion of additional physical processes, including multicomponent transport, finite-rate gas–surface chemistry, pyrolysis, internal oxidation, and material recession. It also provides a framework for connecting pore-scale simulations and microstructural characterization with macroscale aerothermal-response calculations. This report is intended for researchers and engineers working in computational fluid dynamics, porous-media transport, material response, and thermal protection system modeling. It documents both the theoretical development and the initial numerical assessment of the one-domain approach, while identifying the closure of effective and dispersion terms as an important subject for continued investigation.

Ablation

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Enhancing Nasa Sounding Rocket Capabilities Through Composite Material Adoption

Sounding rockets are a suborbital research platform employed by NASA for heliophysics, astrophysics, and geospace science investigations, and for technology development. They follow semi-parabolic trajectories and are launched using surplus military, and commercial, solid-propellant rocket motors. NASA sounding rocket payloads are comprised of standard, modular subassemblies, designed to perform specific functions critical to achieving mission success criteria. Since the program’s inception, payload length and mass have trended upwards, limiting the capability of the platform to reach exospheric apogees and decreasing the time above critical altitudes to observe solar and celestial targets. To offset this trend, composite materials may be of use in payload and subsystem design to decrease payload mass. This investigation seeks to understand if there is a practical benefit to introducing composite materials on the NSRP by assessing mission specific impacts to those missions conducted in fiscal year 2024. To accurately estimate the mass of a composites-based payload, a standard subsystem (NIACS) underwent structural reconfiguration. Materials were selected that align with NSRP design, manufacturing, and testing standards. NIACS reconfiguration resulted in a mass reduction of 19.6% which was then applied to the payload system in entirety. Using vehicle performance carpet plots, delta apogee and time above the Kármán line were determined. Performance improvements were then evaluated against that mission’s success criteria to determine if that mission would have benefitted from using composite materials. On average, each mission would have gained 59.8 kilometers apogee and 62.9 seconds above the Kármán line. However, only nine of the seventeen missions would have benefitted from these performance improvements. Two of the missions could have used a lower-impulse launch vehicle to achieve mission success. Upleg stability met programmatic criteria; downleg instability and dynamic pressure improved, showing that ballast would not offset the mass reduction of using composite materials. Cost analysis showed that production costs will increase 39%. For the two missions that could have used a lower-impulse launch vehicle, the cost of the launch vehicle would have offset payload production costs. In summary, composite materials are not recommended for universal use on NASA sounding rocket payloads due to unclear programmatic benefits and added cost. However, they are justified for optical astrophysics and heliophysics missions, high-apogee (exosphere) requirements, or when they reduce payload costs versus higher impulse launch vehicles. Reflown, recoverable subsystems should use composites to enhance apogee and observation time.

Robert Henry Burth

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)