Search NASASearch

SEARCH · Search NASA

Results for “Surface area to volume ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,500 records · Page 31

Fluidized Bed Gasification For Conversion of Biomass and Waste Materials to Renewable Hydrogen

This project was undertaken in order to study the potential for hydrogen production, at low cost, from mixtures of biomass and municipal solid waste (MSW). This approach allows for the production of hydrogen with a very low fossil carbon burden, while taking advantage of tipping fees (associated with MSW) to improved process economics. The team sourced three primary feedstocks (wood, MSW, and waste plastics) and characterized them comprehensively using established techniques with a long track record in the field of gasification. All three primary feedstocks were highly reactive and lost most of their mass during initial devolatilization. The production of tars, including heavy tars, was quite high, and was most problematic in the case of the MSW and Waste Plastics feedstocks. Little practical difference was identified between the MSW and Waste Plastics materials, and the addition of bed-forming materials (dolomite and brown alumina) to the feedstocks was found to reduce production of tars during devolatilization under thermogravimetric analysis and/or Fischer Assay conditions. A series of four tests in a lab-scale bubbling-fluidized-bed gasifier, at 50 psig of pressure and about 825 C, confirmed these findings. Pellet feedstocks, broken into fragments, were used for these tests, and pellets comprised of 50% MSW and 50% biomass were found to be the best option in terms of fossil carbon burden, economic potential, and gasification characteristics. Tests were then undertaken in a pilot-scale gasifier facility based on the GTI U-Gas fluidized-bed gasification technology. The feedstock handling train of the 20 TPD U-Gas pilot-scale gasifier located in Des Plaines, IL, was operated under simulated gasification conditions, and the 50/50 pellets were found to be very robust and unproblematic. An improved design for the forward end of the feedstock injection screw of the gasifier was developed and installed. The design approach was based on improved passive cooling of the front-most shroud at the end of the screw, since this approach was found in comprehensive modeling studies to be more than sufficient to accomplish the project objectives associated with this phase of the work, while also avoiding thermal gradients that could have caused heat-stress-induced damage to the refractory around the feedstock inlet if an active cooling approach had been applied. Careful technoeconomic analysis (TEA) of two possible 1000 TPD facilities was carried out. The TEA of conversion of MSW with corn stover in one case, and MSW with woody feedstock in the other case, showed that both had the potential to provide hydrogen at about $1/kg (minimum selling price, 2018 dollar basis). Of the two TEA cases, the one that was based on the conversion of wood in the southeastern USA was found to have slightly better economic potential. The other TEA case was based on a real location in Nebraska and called for corn stover feedstock conversion along with MSW. An underserved communities outreach program plan was developed in cooperation with personnel from the Nebraska Public Power District.

08 HYDROGEN

Semi-Transparent Perovskite Solar Cells in a Stacked Tandem Module: Cooperative Research and Development Final Report, CRADA Number CRD-19-00810

This project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, anti-reflection layer composition and deposition process, and cell to module integration processes. Modification 5: The proposed project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically-stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, passivation layers including in module scribes, anti-reflection layer composition and deposition process, and cell to module integration processes. Advanced metrology and characterization will be performed on perovskite films, cells and module. Furthermore, we will examine module or materials recycling for circular economy considerations. Modifcation 6: Gigahertz frequency microwave pump-probe spectroscopies are highly sensitive to thin film semiconductor photoconductivity of individual and stacks of layers that comprise perovskite solar cells. As such, these techniques will be used to qualify reproducibility and quality correlations during the manufacturing process. Modification 7: Mechanical adhesion of top contacts within perovskite modules significantly impacts the durability of the module when exposed to accelerated degradation testing. The adhesion between the perovskite/transport layer interface and the transport layer/top contact interface are both very sensitive small changes in processing. ALD processing conditions of the transport layer will be tuned to optimize the mechanical adhesion within the perovskite module stack.

14 SOLAR ENERGY

Material efficiency technologies in the food and beverage industry

The U.S. food and beverage (F&B) sector is a major contributor to manufacturing gross domestic product and supports substantial employment and economic activity, while exerting significant pressures on land and water resources. At the same time, the industry faces growing expectations to balance its resource-intensive operations without compromising cost competitiveness. Material inefficiencies across the F&B value chain, particularly in raw material use and product loss/waste, lead to substantial financial losses and resource depletion. Thus, the F&B sector requires adoption of solutions and measures to avoid food wastage, reduce raw material consumption and valorize waste to high-value added products. This work presents a comprehensive understanding of the various technology solutions available for the F&B sector. The following two research questions are addressed: “What are the mid-to-high Technology Readiness Level technologies or measures to reduce material use and enable waste valorization in the F&B sector? What are the barriers to their commercial deployment? Additionally, what targeted research and development efforts are needed to overcome these barriers and accelerate their scale-up?” The findings are intended to support evidence-based decision-making, guide strategic investment, and help stakeholders strengthen resilience and competitiveness across the F&B sector.

Nain, Preeti [ORNL] (ORCID:0000000258358959)

Efficient electrocatalytic valorization of chlorinated organic water pollutant to ethylene

Electrochemistry can provide an efficient and sustainable way to treat environmental waters polluted by chlorinated organic compounds. However, the electrochemical valorization of 1,2-dichloroethane (DCA) is currently challenged by the lack of a catalyst that can selectively convert DCA in aqueous solutions into ethylene. Here, in this work, we report a catalyst comprising cobalt phthalocyanine molecules assembled on multiwalled carbon nanotubes that can electrochemically decompose aqueous DCA with high current and energy efficiencies. Ethylene is produced at high rates with unprecedented ~100% Faradaic efficiency across wide electrode potential and reactant concentration ranges. Kinetic studies and density functional theory calculations reveal that the rate-determining step is the first C–Cl bond breaking, which does not involve protons—a key mechanistic feature that enables cobalt phthalocyanine/carbon nanotube to efficiently catalyse DCA dechlorination and suppress the hydrogen evolution reaction. The nanotubular structure of the catalyst enables us to shape it into a flow-through electrified membrane, which we have used to demonstrate >95% DCA removal from simulated water samples with environmentally relevant DCA and electrolyte concentrations.

Choi, Chungseok [Yale Univ., New Haven, CT (United

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Robust negativity in the quantum-to-classical transition of Kerr dynamics

Here, we quantify the quantum-to-classical transition of the single-mode Kerr nonlinear dynamics in the presence of loss. We establish three timescales that govern the dynamics, each with distinct characteristics. For times short compared with the Ehrenfest time, the evolution is classical, characterized by Gaussian dynamics. For sufficiently long times, as we increase the initial photon number, unitary Kerr evolution would generate macroscopic superpositions of coherent states (so-called kitten states). However, this is severely restricted in the presence of small photon loss, and the expectation values of observables coincide with their classical values. The intermediate timescale, however, shows resilient quantum behavior in the macroscopic limit. We show that in the mean-field non-Gaussian regime, the Kerr Hamiltonian (with small photon loss) generates a significant amount of Wigner-negativity, and classical flow is recovered only if the loss rate grows with system size. Our results broaden the usual understanding of quantum-to-classical transitions and demonstrate the potential for creating robust nonclassical resources for continuous-variable quantum information processing in the presence of loss.

Raza, Mohsin [University of New Mexico, Albuquerqu

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter

Automation of Solid Oxyde Electrolyzer Cell (SOEC) & Stack Assembly

The work performed under this agreement before the No/Go decision amounted to the following: 1. Preliminary manufacturing requirements defined by business sensitivity, baseline processes & risk assessment; 2. Process & materials development, in-line gauge exploration, and preliminary automation work used to reduce risk & further refine equipment specifications; 3. “Request for Quote” issued to multiple suppliers for major equipment; 4. Application specific equipment, hardware, and fixturing will be more beneficial to fabricate inhouse; 5.Current proposals & estimates meet cycle time, capital spend, & direct labor; space is on target but requires awareness; 6. Team will continue to explore opportunities to reduce risk (dry time, traceability); 7. Go / No-Go, Purchase Orders, Equipment build & commissioning next All other future task were not completed because during the Go /No-Go decision it was confirmed this project was a "No-Go" and did not proceed past BP1; these included the following: 1. Preliminary manufacturing requirements defined by business sensitivity, baseline processes & risk assessment; 2. Process & materials development, in-line gauge exploration, and preliminary automation work used to reduce risk & further refine equipment specifications; 3. “Request for Quote” issued to multiple suppliers for major equipment; 4. Application specific equipment, hardware, and fixturing will be more beneficial to fabricate inhouse; 5. Current proposals & estimates meet cycle time, capital spend, & direct labor; space is on target but requires awareness; 6. Team will continue to explore opportunities to reduce risk (dry time, traceability) In final preparation of the termination of the Automation of Solid Oxyde Electrolyzer Cell (SOEC) & Stack Assembly, Cummins has purchased no equipment with government funds, and there is no government-owned property in Cummins possession related to this project. Minimal labor and travel were completed and paid. This acts as the Final technical report and concludes our business with DOE on this grant.

36 MATERIALS SCIENCE

Specific Bacterial Taxa and Their Metabolite, DHPS, May Be Linked to Gut Dyshomeostasis in Patients with Alzheimer’s Disease, Parkinson’s Disease, and Amyotrophic Lateral Sclerosis

Background: Neurodegenerative diseases (NDDs) are multifactorial disorders frequently associated with gut dysbiosis, oxidative stress, and inflammation; however, the pathophysiological mechanisms remain poorly understood. Methods: Using untargeted mass spectrometry-based metabolomics and 16S sequencing of human stool, we investigated bacterial and metabolic dyshomeostasis in the gut microbiome associated with early disease stages across three NDDs—amyotrophic lateral sclerosis (ALS), Alzheimer’s disease (AD), Parkinson’s disease (PD)—and healthy controls (HC). Results: We discovered a previously unrecognized link between a microbial-derived metabolite with an unknown role in human physiology, 2,3-dihydroxypropane-1-sulfonate (DHPS), and gut dysbiosis in NDDs. DHPS was downregulated in AD, ALS, and PD, while bacteria involved in DHPS metabolism, Eubacterium and Desulfovibrio, were increased in all disease cohorts. Additionally, select taxa within the Clostridia class had strong negative correlations to DHPS, suggesting a potential role in DHPS metabolism. A catabolic product of DHPS is hydrogen sulfide, and when in excess, it is known to promote inflammation, oxidative stress, mitochondrial damage, and gut dysbiosis, known hallmarks of NDDs. Conclusions: These findings suggest that cryptic sulfur metabolism via DHPS is a potential missing link in our current understanding of gut dysbiosis associated with NDD onset and progression. As this was a hypothesis generating study, more work is needed to elucidate the role of DHPS in gut dysbiosis and neurodegenerative diseases.

Nutrition & Dietetics

From PINNs to PIKANs: recent advances in physics-informed machine learning

Physics-Informed Neural Networks (PINNs) have emerged as a key tool in Scientific Machine Learning since their introduction in 2017, enabling the efficient solution of ordinary and partial differential equations using sparse measurements. Over the past few years, significant advancements have been made in the training and optimization of PINNs, covering aspects such as network architectures, adaptive refinement, domain decomposition, and the use of adaptive weights and activation functions. A notable recent development is the Physics-Informed Kolmogorov-Arnold Networks (PIKANS), which leverage a representation model originally proposed by Kolmogorov in 1957, offering a promising alternative to traditional PINNs. In this review, we provide a comprehensive overview of the latest advancements in PINNs, focusing on improvements in network design, feature expansion, optimization techniques, uncertainty quantification, and theoretical insights. We also survey key applications across a range of fields, including biomedicine, fluid and solid mechanics, geophysics, dynamical systems, heat transfer, chemical engineering, and beyond. Lastly, we review computational frameworks and software tools developed by both academia and industry to support PINN research and applications.

Kolmogorov-Arnold networks

Circumventing data imbalance in magnetic ground state data for magnetic moment predictions

Abstract Magnetic materials play a crucial role in the transition to more sustainable forms of energy and electric vehicles. There is an anticipated shortage in magnetic materials in the future, and as a result there is an urgent need to discover and design new magnetic materials. Computational magnetic material design using density functional theory is daunting because of the challenge in identifying magnetic ground states from a combinatorially large set of possibilities. Machine learning offers a path forward by enabling efficient surrogate models that can more readily enumerate these states, but there is a dearth of training data available, and what is available tends to be imbalanced with too much non-magnetic data. In this work we show that the discrete and previously tackled data imbalance that exists at the level of the magnetic ordering leads to an imbalanced continuous distribution with many zeros when the data is unraveled at the atomic magnetic moment level, which subsequently leads to models with low accuracy for magnetic properties. We mitigate this by using a two-part model framework. Our scheme is able to classify atoms into magnetic and non-magnetic with an F1 score and Matthew’s correlation coefficient (MCC) of ~91% and then to provide an implicit embedding representation that maps directly onto the magnitude of the magnetic moment with a mean absolute error of 0.1 μ B . Beyond screening for new magnetic materials, we demonstrate an additional practical use case of our scheme: the provision of good initial guesses for magnetic moments in first-principles electronic relaxations. Such initialization is shown to lead to faster convergence to configurations that lie closer to the ground state.

Computer Science

Development of Hydrogen Burner for FT4000® Aeroderivative Engine - Final Report

This report details an effort to develop a retrofittable fuel/air injector for the FT4000® aeroderivative gas turbine that enables use of hydrogen as a carbon-free fuel for efficient power generation. The FT4000 engine’s low-NOx combustor was developed by Pratt & Whitney and RTX Technology Research Center with core technology from the Pratt & Whitney PW4000 turbofan aircraft engine. The current FT4000 production engine operates on either natural gas or No. 2 fuel oil with water injection to achieve high thermal efficiency and low emissions. This engine is fielded by Mitsubishi Power Aero and delivers 70 MW of power with a simple-cycle efficiency of over 41% when operating with wet compression. The work reported here advances the technology readiness level of the FT4000 combustor for operation with hydrogen, starting with an experimental assessment of the current production hardware with increasing hydrogen content mixed with natural gas and ending with improved nozzle concepts for fully robust operation with 100% hydrogen. High-pressure single-sector combustor rig tests have been completed, demonstrating the ability for the dual fuel nozzle to operate an FT4000 combustor on 100% hydrogen with low nitrogen oxide (NOx) emissions. Metal temperature measurements and video images of the flame structure from zero to 100% hydrogen highlight opportunities to improve the fuel nozzle robustness for high hydrogen conditions. The design of new fuel/air mixer concepts to improve durability and operability with high hydrogen levels was also completed. A total of eleven new concepts were developed and analyzed, ranging from modifications to the bill-of-materials nozzle to fully clean sheet designs. The concepts were evaluated with non-reacting and reacting flow evaluations to assess the performance of the new hardware designs. Non-reacting tests included Phase Doppler Particle Analysis (PDPA) for droplet size and velocity, mechanical patternation for liquid water flux, and planar laser induced fluorescence (PLIF) with acetone-seeding for gaseous fuel/air mixing characterization. Five scaled candidate fuel nozzle designs, in addition to a scaled bill-of-materials nozzle, were then successfully evaluated in an atmospheric pressure burner rig. The nozzles were evaluated for performance with natural gas, hydrogen/natural gas blends, and pure hydrogen. For 100% hydrogen, the nozzles were evaluated with and without water injection. Optical and infrared imaging of the flame and fuel nozzle was captured. NOx emissions were sampled from fixed emissions probes. The results show measurable differences between the various designs, and the data was used to down-select the two most promising designs to advance to future full pressure rig testing. Results from this study have cleared the current production FT4000 engines with dual fuel nozzles to operate at baseload power on blends of hydrogen mixed with natural gas and water. Two promising nozzle designs have been developed to enable fully robust operation with up to 100% hydrogen. These nozzles require validation at full baseload operating conditions before they can be introduced to the field.

03 NATURAL GAS

Calculating a minimum overlap period for successful intercalibration of soil moisture sensors

Abstract Long‐term in situ soil moisture monitoring inevitably requires sensors to be replaced. Ensuing discontinuities in the data record can be mitigated by intercalibration, however it is unclear how long the existing sensor needs to remain alongside the newly installed before there is enough overlapping data to generate a robust intercalibration. We used 154 pairs of established and newly installed sensors within the Marena, Oklahoma, In Situ Sensor Testbed to determine if there is a minimum overlap time that should be considered when planning upcoming replacements. Hourly observations of the existing sensor were linearly calibrated to those of the newly installed sensor with coefficients determined from overlap periods incremented by 30 days until a reference period of 2 years was reached. The resulting bias, root‐mean‐square error, and correlation coefficient for sensor pairs indicate that a minimum of 6 to 9 months of overlapping data are required to generate a successful intercalibration. Extending that to a full year before decommissioning the old sensor results in a stable intercalibration with higher confidence.

Agriculture

Linking Community‐Climate Disequilibrium to Ecosystem Function

Turnover in species composition often lags behind the pace of climate change, resulting in mismatches between climate and communities. However, the impact of these community‐climate disequilibria on ecosystem functions is rarely considered, and current methods for measuring disequilibria assume that species ranges were, until recently, in equilibrium with climate. Here, in this work, we develop a simple theoretical model to address both of these problems by linking community‐climate disequilibrium with ecosystem functioning. We show how disequilibrium can impair functioning in the near‐term even when climate change is expected to enhance functioning in the long‐term. Responses are most likely to change over time in communities where turnover is slow, the impact of disequilibrium counteracts the direct effects of climate on ecosystem function, and pre‐existing disequilibrium is large. These findings emphasise the importance of precise and unbiased estimates of community‐climate disequilibria for improving ecological forecasts. By fitting our model to time series of both climate and ecosystem function from a metacommunity simulation, we show the potential for community‐climate disequilibrium to be inferred without direct knowledge about species' distributions or climatic tolerances. We end by outlining a research agenda to apply dynamic disequilibrium concepts and test novel hypotheses across diverse ecosystems.

climate change

Tracing Phase Transformation and Lattice Evolution in a TRIP Sheet Steel under High-Temperature Annealing by Real-Time In Situ Neutron Diffraction

Real-time in situ neutron diffraction was used to characterize the crystal structure evolution in a transformation-induced plasticity (TRIP) sheet steel during annealing up to 1000 °C and then cooling to 60 °C. Based on the results of full-pattern Rietveld refinement, critical temperature regions were determined in which the transformations of retained austenite to ferrite and ferrite to high-temperature austenite during heating and the transformation of austenite to ferrite during cooling occurred, respectively. The phase-specific lattice variation with temperature was further analyzed to comprehensively understand the role of carbon diffusion in accordance with phase transformation, which also shed light on the determination of internal stress in retained austenite. These results prove the technique of real-time in situ neutron diffraction as a powerful tool for heat treatment design of novel metallic materials.

Yu, Dunji [ORNL] (ORCID:0000000189467851)

Toyota Highlander FCHV (CRADA CRD-12-00469 Final Report)

This project relates to the loan of four Toyota Mirai FCEV-adv vehicles to NLR to provide a load (vehicles to fill with hydrogen) to our fueling station research facility to study hydrogen fueling infrastructure performance using 700 bar precooled hydrogen at ESIF’s Hydrogen Infrastructure Testing and Research Facility (HITRF) facility.

33 ADVANCED PROPULSION SYSTEMS

A novel compact end-loaded piston cylinder cell for high pressure neutron scattering up to 5 GPa

Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.

Neutrons

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE