Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Global Positioning System Simulator Field Operational Procedures

Global Positioning System (GPS) simulation is an important activity in the development or qualification of GPS signal receivers for space flight. Because a GPS simulator is a critical resource it is highly desirable to develop a set of field operational procedures to supplement the basic procedures provided by most simulator vendors. Validated field procedures allow better utilization of the GPS simulator in the development of new test scenarios and simulation operations. These procedures expedite simulation scenario development while resulting in scenarios that are more representative of the true design, as well as enabling construction of more complex simulations than previously possible, for example, spacecraft maneuvers. One difficulty in the development of a simulation scenario is specifying various modes of test vehicle motion and associated maneuvers requiring that a user specify some (but not all) of a few closely related simulation parameters. Currently this can only be done by trial and error. A stand-alone procedure that implements the simulator maneuver motion equations and solves for the motion profile transient times, jerk and acceleration would be of considerable value. Another procedure would permit the specification of some configuration parameters that would determine the simulated GPS signal composition. The resulting signal navigation message, for example, would force the receiver under test to use only the intended C-code component of the simulated GPS signal. A representative class of GPS simulation-related field operational procedures is described in this paper. These procedures were developed and used in support of GPS integration and testing for many successful spacecraft missions such as SAC-A, EO-1, AMSAT, VCL, SeaStar, sounding rockets, and by using the industry standard Spirent Global Simulation Systems Incorporated (GSSI) STR series simulators.

Kizhner, Semion↗

Computer program for analysis of high speed, single row, angular contact, spherical roller bearing, SASHBEAN. Volume 1: User's guide

The computer program SASHBEAN (Sikorsky Aircraft Spherical Roller High Speed Bearing Analysis) analyzes and predicts the operating characteristics of a Single Row, Angular Contact, Spherical Roller Bearing (SRACSRB). The program runs on an IBM or IBM compatible personal computer, and for a given set of input data analyzes the bearing design for it's ring deflections (axial and radial), roller deflections, contact areas and stresses, induced axial thrust, rolling element and cage rotation speeds, lubrication parameters, fatigue lives, and amount of heat generated in the bearing. The dynamic loading of rollers due to centrifugal forces and gyroscopic moments, which becomes quite significant at high speeds, is fully considered in this analysis. For a known application and it's parameters, the program is also capable of performing steady-state and time-transient thermal analyses of the bearing system. The steady-state analysis capability allows the user to estimate the expected steady-state temperature map in and around the bearing under normal operating conditions. On the other hand, the transient analysis feature provides the user a means to simulate the 'lost lubricant' condition and predict a time-temperature history of various critical points in the system. The bearing's 'time-to-failure' estimate may also be made from this (transient) analysis by considering the bearing as failed when a certain temperature limit is reached in the bearing components. The program is fully interactive and allows the user to get started and access most of its features with a minimal of training. For the most part, the program is menu driven, and adequate help messages were provided to guide a new user through various menu options and data input screens. All input data, both for mechanical and thermal analyses, are read through graphical input screens, thereby eliminating any need of a separate text editor/word processor to edit/create data files. Provision is also available to select and view the contents of output files on the monitor screen if no paper printouts are required. A separate volume (Volume-2) of this documentation describes, in detail, the underlying mathematical formulations, assumptions, and solution algorithms of this program.

Aggarwal, Arun K.↗

Numerical simulations of microflare evolution in the solar transition region and corona

Several observers report transient ultraviolet brightenings, often referred to as microflares, in the solar atmosphere. In this paper, the results are presented of a series of one-dimensional numerical simulations examining possible relationships between microflares and the generation of dynamical chromospheric and transition region features. Low-energy and medium-energy microflares eject long-lived cool, dense gas plugs into the corona, with the gas plug traversing the loop apex in the medium energy case. In the case of high-energy microflares, the gas plug is rapidly heated to the temperature of the surrounding corona, and the results resemble the dynamics occurring in standard solar flare thick-target electron beam models.

Sterling, Alphonse C.↗

Evaluation of Test/Analysis Correlation Methods for Crash Applications

A project has been initiated to improve crash test and analysis correlation. The work in this paper concentrated on the test and simulation results for a fuselage section. Two drop tests of the section were conducted. The first test was designed to excite the linear structural response for comparison with finite element modal analysis results. The second test was designed to provide data for correlation with crash simulations. An MSC.Dytran model was developed to generate nonlinear transient dynamic results. Following minor modifications, the same model was executed in MSC.Nastran to generate modal analysis results. The results presented in this paper concentrate on evaluation of correlation methodologies for crash test data and finite element simulation results.

Lyle, Karen H.↗

Dynamic characteristics of a 20 kHz resonant power system - Fault identification and fault recovery

A detailed simulation of a dc inductor resonant driver and receiver is used to demonstrate the transient characteristics of a 20 kHz resonant power system during fault and overload conditions. The simulated system consists of a dc inductor resonant inverter (driver), a 50-meter transmission cable, and a dc inductor resonant receiver load. Of particular interest are the driver and receiver performance during fault and overload conditions and on the recovery characteristics following removal of the fault. The information gained from these studies sets the stage for further work in fault identification and autonomous power system control.

Wasynczuk, O.↗

A three-dimensional transport model for the middle atmosphere

In this paper we describe fundamental properties of an 'off-line' three-dimensional transport model, that is, a model which uses prescribed rather than predicted winds. The model is currently used primarily for studying problems of the middle atmosphere because we have not (yet) incorporated a formulation for the convective transport of trace species, a prerequisite for many tropospheric problems. The off-line model is simpler and less expensive than a model which predicts the wind and mass evolution (an 'on-line' model), but it is more complex than the two-dimensional (2-D) zonally averaged transport models often used in the study of chemistry and transport in the middle atmosphere. It thus serves as a model of intermediate complexity and can fill a useful niche for the study of transport and chemistry. We compare simulations of four tracers, released in the lower stratosphere, in both the on- and off-line models to document the difference resulting from differences in modeling the same problem with this intermediate model. These differences identify the price to be paid in going to a cheaper and simpler calculation. The off-line model transports a tracer in three dimensions. For this reason, it requires fewer approximations than 2-D transport model, which must parameterize the effects of mixing by transient and zonally asymmetric wind features. We compare simulations of the off-line model with simulations of a 2-D model for two problems. First, we compare 2-D and three-dimensional (3-D) models by simulating the emission of an NO(x)-like tracer by a fleet of high-speed aircraft. The off-line model is then used to simulate the transport of C-14 and to contrast its simulation properties to that of the host of 2-D models which participated in an identical simulation in a recent NASA model intercomparison. The off-line model is shown to be somewhat sensitive to the sampling strategy for off-line winds. Simulations with daily averaged winds are in very good qualitative agreement but are less diffusive than when driven with instantaneous winds sampled at half-hour intervals. Simulations with the off-line and 2-D models are quite similar in the middle and upper stratosphere but behave quite differently in the lower stratosphere, where the 3-D model has a substantially more vigorous circulation. The off-line model is quite realistic in its simulation of C-14. While there are still systematic differences between the 3-D calculation and the observations, the differences seem to be substantially reduced when compared with the body of 2-D simulations documented in the above mentioned NASA intercomparison, particularly at 31 deg N.

Rasch, Philip J.↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Thermal↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 degrees Centigrade and the heater power goal is to be within 5 percent of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Correlation↗

Modelling of environmentally induced discharges in geosynchronous satellites

The NASCAP computer code was used to compute the charging and discharging characteristics of a typical communications satellite in geosynchronous orbit. For the case of a severe substorm satellite surface differential charging in sunlight was found to be substantially less than that required to produce discharges in ground simulation studies. A discharge process was postulated involving discharges triggered at edges (or imperfection) followed by discharges to space. The characteristics of such discharges was parametrically varied to evaluate the possible effects on the satellite. Results indicated that discharge characteristics inferred from satellite monitors could be caused by predicted space discharges, that single cell discharges to space can reduce surface potentially over entire satellite, and that low density electron trajectory computations indicate that discharge generated electrons do not return to the satellite by long trajectories. Current transients predicted do not agree with available ground simulation results indicating that additional work must be done both analytically and experimentally to understand and fully explain these discrepancies.

Stevens, N. J.↗

Development of a ninety string solar array simulator

A power source was developed to support testing for the Space Station Freedom Power Management and Distribution (PMAD) DC Testbed. The intent was to simulate as closely as possible the steady-state and transient responses of a solar array. Several breadboards and one thermal prototype were built and tested. Responses were successfully verified and improved upon during successive breadboards. The completed 90-string simulator consists of four power MOSFETs, four 25 watt source resistors, and four 250 watt drain source bypass resistors per string, in addition to the control circuitry.

Vasek, Thomas E.↗

Development of a ninety string solar array simulator

A power source was developed to support testing for the Space Station Freedom Power Management and Distribution (PMAD) DC Testbed. The intent was to simulate as closely as possible the steady-state and transient responses of a solar array. Several breadboards and one thermal prototype were built and tested. Responses were successfully verified and improved upon during successive breadboards. The completed 90-string simulator consists of four power MOSFETs, four 25-watt source resistors, and four 250-watt drain source bypass resistors per string, in addition to the control circuitry.

Vasek, Thomas E.↗

Thermographic Imaging of Defects in Anisotropic Composites

Composite materials are of increasing interest to the aerospace industry as a result of their weight versus performance characteristics. One of the disadvantages of composites is the high cost of fabrication and post inspection with conventional ultrasonic scanning systems. The high cost of inspection is driven by the need for scanning systems which can follow large curve surfaces. Additionally, either large water tanks or water squirters are required to couple the ultrasonics into the part. Thermographic techniques offer significant advantages over conventional ultrasonics by not requiring physical coupling between the part and sensor. The thermographic system can easily inspect large curved surface without requiring a surface following scanner. However, implementation of Thermal Nondestructive Evaluations (TNDE) for flaw detection in composite materials and structures requires determining its limit. Advanced algorithms have been developed to enable locating and sizing defects in carbon fiber reinforced plastic (CFRP). Thermal Tomography is a very promising method for visualizing the size and location of defects in materials such as CFRP. However, further investigations are required to determine its capabilities for inspection of thick composites. In present work we have studied influence of the anisotropy on the reconstructed image of a defect generated by an inversion technique. The composite material is considered as homogeneous with macro properties: thermal conductivity K, specific heat c, and density rho. The simulation process involves two sequential steps: solving the three dimensional transient heat diffusion equation for a sample with a defect, then estimating the defect location and size from the surface spatial and temporal thermal distributions (inverse problem), calculated from the simulations.

Plotnikov, Y. A.↗

Investigation of a Macromechanical Approach to Analyzing Triaxially-Braided Polymer Composites

A macro level finite element-based model has been developed to simulate the mechanical and impact response of triaxially-braided polymer matrix composites. In the analytical model, the triaxial braid architecture is simulated by using four parallel shell elements, each of which is modeled as a laminated composite. The commercial transient dynamic finite element code LS-DYNA is used to conduct the simulations, and a continuum damage mechanics model internal to LS-DYNA is used as the material constitutive model. The material stiffness and strength values required for the constitutive model are determined based on coupon level tests on the braided composite. Simulations of quasi-static coupon tests of a representative braided composite are conducted. Varying the strength values that are input to the material model is found to have a significant influence on the effective material response predicted by the finite element analysis, sometimes in ways that at first glance appear non-intuitive. A parametric study involving the input strength parameters provides guidance on how the analysis model can be improved.

Goldberg, Robert K.↗

A Comparative Study of Simulated and Measured Gear-Flap Flow Interaction

The ability of two CFD solvers to accurately characterize the transient, complex, interacting flowfield asso-ciated with a realistic gear-flap configuration is assessed via comparison of simulated flow with experimental measurements. The simulated results, obtained with NASA's FUN3D and Exa's PowerFLOW® for a high-fidelity, 18% scale semi-span model of a Gulfstream aircraft in landing configuration (39 deg flap deflection, main landing gear on and off) are compared to two-dimensional and stereo particle image velocimetry measurements taken within the gear-flap flow interaction region during wind tunnel tests of the model. As part of the bench-marking process, direct comparisons of the mean and fluctuating velocity fields are presented in the form of planar contour plots and extracted line profiles at measurement planes in various orientations stationed in the main gear wake. The measurement planes in the vicinity of the flap side edge and downstream of the flap trailing edge are used to highlight the effects of gear presence on tip vortex development and the ability of the computational tools to accurately capture such effects. The present study indicates that both computed datasets contain enough detail to construct a relatively accurate depiction of gear-flap flow interaction. Such a finding increases confidence in using the simulated volumetric flow solutions to examine the behavior of pertinent aer-odynamic mechanisms within the gear-flap interaction zone.

Khorrami, Mehdi R.↗

A Gas-Actuated Projectile Launcher for High-Energy Impact Testing of Structures

A gas-act,uated penetration device has been developed for high-energy impact testing of structures. The high-energy impact. t,estiiig is for experimental simulation of uncontained engine failures. The non-linear transient finite element, code LS-DYNA3D has been used in the numerical simula.tions of a titanium rectangular blade with a.n aluminum target, plate. Threshold velocities for different combinations of pitch and yaw angles of the impactor were obtained for the impactor-target, t8est configuration in the numerica.1 simulations. Complet,e penet,ration of the target plate was also simulat,ed numerically. Finally, limited comparison of analytical and experimental results is presented for complete penetration of the target by the impactor.

Ambur, Damodar R.↗

Simulation of Cold Flow in a Truncated Ideal Nozzle with Film Cooling

Flow transients during rocket start-up and shut-down can lead to significant side loads on rocket nozzles. The capability to estimate these side loads computationally can streamline the nozzle design process. Towards this goal, the flow in a truncated ideal contour (TIC) nozzle has been simulated for a range of nozzle pressure ratios (NPRs) aimed to match a series of cold flow experiments performed at the NASA MSFC Nozzle Test Facility. These simulations were performed with varying turbulence model choices and with four different versions of the TIC nozzle model geometry, each of which was created with a different simplification to the test article geometry.

Braman, Kalen↗

Simulation of Cold Flow in a Truncated Ideal Nozzle with Film Cooling

Flow transients during rocket start-up and shut-down can lead to significant side loads on rocket nozzles. The capability to estimate these side loads computationally can streamline the nozzle design process. Towards this goal, the flow in a truncated ideal contour (TIC) nozzle has been simulated using RANS and URANS for a range of nozzle pressure ratios (NPRs) aimed to match a series of cold flow experiments performed at the NASA MSFC Nozzle Test Facility. These simulations were performed with varying turbulence model choices and for four approximations of the supersonic film injection geometry, each of which was created with a different simplification of the test article geometry. The results show that although a reasonable match to experiment can be obtained with varying levels of geometric fidelity, the modeling choices made do not fully represent the physics of flow separation in a TIC nozzle with film cooling.

Braman, K. E.↗

Numerical analysis of pulse facility transient flow through a supersonic combustion model

The supersonic high enthalpy flow from a shock tunnel facility flowing through a two-dimensional duct simulating a combustor has been computed for two test conditions for both steady and transient inflow. The nominal test conditions had stagnation enthalpies of 4.3 and 12.1 MJ/kg, with corresponding flight Mach numbers of 9 and 16, respectively. A full Navier-Stokes code (SPARK) was used to compute the flow development and the mixing of a hydrogen jet injected from the base of a central strut. Results of the calculations are presented and compared with wall pressure data. Additional comparisons of the transient and steady inflow results are presented to assess the effect of transient flow on the data. This paper presents a status of the progress in applying CFD codes to analyze the transient flow from a pulse facility.

Rogers, R. Clayton↗