Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Measurement of primary cosmic-ray electrons and positrons from 4 to 50 GeV

We have used a bremsstrahlung-identification technique to measure electron and positron spectra in the primary cosmic rays from 4 to 50 GeV. Above our average geomagnetic cutoff of 4.0 GV/c, we find fluxes of 4.4 (plus or minus 0.3) electrons and 0.37 (plus or minus 0.09 positrons) per sq m/sr/sec. The electron events follow a differential power law whose spectral index is 2.8 (plus or minus 0.1). Our ratio electrons/(electrons + positrons) = 0.08 (plus or minus 0.02) implies traversal of an equivalent slab thickness of 4.3 (plus or minus 1.5) g/sq cm of interstellar and source material.

Buffington, A.↗

Direct investigation of subsurface interface electronic structure by ballistic-electron-emission microscopy

A new technique for spectroscopic investigation of subsurface interface electronic structure has been developed. The method, ballistic-electron-emission microscopy (BEEM), is based on scanning tunneling microscopy. BEEM makes possible, for the first time, direct imaging of subsurface interface properties with nanometer spatial resolution. The first application of BEEM to subsurface Schottky-barrier interfaces is reported.

Kaiser, W. J.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimetric (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single CW laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640 x 480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Excited states in variational Monte Carlo using a penalty method

Here, in this article, the authors present a technique using variational Monte Carlo to solve for excited states of electronic systems. This technique is based on enforcing orthogonality to lower energy states, which results in a simple variational principle for the excited states. Energy optimization is then used to solve for the excited states. This technique is applied to the well-characterized benzene molecule, in which ~10 000 parameters are optimized for the first 12 excited states. Agreement within ~0.2 eV is obtained with higher scaling coupled cluster methods; small disagreements with experiment are likely due to vibrational effects.

36 MATERIALS SCIENCE↗

Determination of the mean energy of fast electron losses and anisotropies through thick-target emission on WEST

Abstract A new method to obtain the mean energy of fast electron losses in fusion plasmas using a versatile multi-energy hard x-ray (HXR) detector is presented. The method is based on measuring the thick-target emission of tungsten in the divertor region produced by fast electron losses interacting with the target and modeling the tungsten spectra by a Monte Carlo code which simulates the interaction between a beam of electrons and a solid target. The mean energy of the fast electron losses is determined through the comparison between the experimental and synthetic emission. The results show that fast electron losses during lower hybrid current drive discharges at WEST have a mean energy of 90–140 keV and represent only 2% of the total heat flux at the target. Additionally, anisotropic HXR emission has been detected for the first time at the WEST core and edge plasma, with opposite directions. It is due to the forward-peak emission of two distinctive populations of fast electrons: co-current fast electrons in the core and counter-current fast electron losses at the inner strike point. In view of future experiments like ITER where electron cyclotron current drive will generate a fast electron population, this technique could serve as a real-time monitor of fast electron losses and eventually feed an actuator on the current drive generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial Light Modulator Would Serve As Electronic Iris

In proposed technique for controlling brightness of image formed by lens, spatial light modulator serves as segmented, electronically variable aperture. Offers several advantages: spatial light modulator controlled remotely and responds faster than motorized iris or other remotely controlled mechanical iris. Unlike iris, modulator also configured so as not to vary depth of field appreciably. Unlike lead lanthanum zirconate titanate crystal, spatial light modulator does not require high voltage.

Gutow, David A.↗

Biopolymer‐assisted Synthesis of P‐doped TiO 2 Nanoparticles for High‐performance Lithium‐ion Batteries: A Comprehensive Study

Abstract TiO 2 material has gained significant attention for large‐scale energy storage due to its abundant, low‐cost, and environmentally friendly properties, as well as the availability of various nanostructures. Phosphorus doping has been established as an effective technique for improving electronic conductivity and managing the slow ionic diffusion kinetics of TiO 2 . In this study, non‐doped and phosphorus doped TiO 2 materials were synthesized using sodium alginate biopolymer as chelating agent. The prepared materials were evaluated as anode materials for lithium‐ion batteries (LIBs). The electrodes exhibit remarkable electrochemical performance, including a high reversible capacity of 235 mAh g −1 at 0.1 C and excellent first coulombic efficiency of 99 %. An integrated approach, combining operando XRD and ex‐situ XAS, comprehensively investigates the relationship between phosphorus doping, material structure, and electrochemical performance, reinforced by analytical tools and first principles calculations. Furthermore, a full cell was designed using 2 %P‐doped TiO 2 anode and LiFePO 4 cathode. The output voltage was about 1.6 V with high initial specific capacity of 148 mAh g −1 , high rate‐capability of 120 mAh g −1 at 1 C, and high‐capacity retention of 96 % after 1000 cycles at 1 C.

El Halya, Nabil↗

Reconstruction and uncertainty quantification of lattice Hamiltonian model parameters from observations of microscopic degrees of freedom

The emergence of scanning probe and electron beam imaging techniques has allowed quantitative studies of atomic structure and minute details of electronic and vibrational structure on the level of individual atomic units. These microscopic descriptors, in turn, can be associated with local symmetry breaking phenomena, representing the stochastic manifestation of the underpinning generative physical model. In this work, we explore the reconstruction of exchange integrals in the Hamiltonian for a lattice model with two competing interactions from observations of microscopic degrees of freedom and establish the uncertainties and reliability of such analysis in a broad parameter-temperature space. In contrast to other approaches, we specifically specify a loss function inherent to thermodynamic systems and utilize it to estimate uncertainty in simulated realizations of different models. As an ancillary task, we develop a machine learning approach based on histogram clustering to predict phase diagrams efficiently using a reduced descriptor space. We further demonstrate that reconstruction is possible well above the phase transition and in the regions of parameter space when the macroscopic ground state of the system is poorly defined due to frustrated interactions. This suggests that this approach can be applied to the traditionally complex problems of condensed matter physics such as ferroelectric relaxors and morphotropic phase boundary systems, spin and cluster glasses, and quantum systems once the local descriptors linked to the relevant physical behaviors are known.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The effects of electron and gamma radiation on epoxy-based materials

Specimens of graphite/epoxy composites and epoxy resins were exposed to electron and gamma radiation, followed by mechanical property and fundamental measurements. Measurement techniques included: scanning electron microscopy, X-ray diffraction analysis, and electron spin resonance spectroscopic analysis. Results indicate little or no change in flexural properties of miniature specimens of a graphite/epoxy composite and no change in failure mode at the fiber-resin interface and in the crystallinity of the fiber and the resin. Some doubt in the observation of stable flexural properties is cast by electron paramagnetic resonance spectra of a relatively large number of radiation-generated radicals. These generally lead to a change in cross-linking and in chain-scissioning which should alter mechanical properties.

Fornes, R. E.↗

Numerical simulation of a disk-shaped electron accelerating electrostatic probe

This paper presents a method utilizing the numerical plasma simulation particle-in-cell technique for studying electron accelerating probe characteristics. A probe configuration other than the commonly used plane, cylindrical, or spherical case will be studied; the probe configuration used is that of a disk. Cylindrical geometry is used in the simulation model. One of the advantages of a numerical simulation is the ease with which the details of the system can be examined. Therefore, in addition to the current-voltage characteristics of the static probe, other results are presented such as the time evolution of the plasma properties and studies of the sheath region surrounding the probe.

Nonnast, J. H.↗

Coal thickness guage using RRAS techniques, parts 2 and 3

Electron magnetic resonance was investigated as a sensing technique for use in measuring the thickness of the layer of coal overlying the rock substrate. The goal is development of a thickness gauge which will be usable for control of mining machinery to maintain the coal thickness within selected bounds. A sensor must be noncontracting, have a measurement range of 6 inches or more, and an accuracy of 1/2 inch or better. The sensor should be insensitive to variations in spacing between the sensor and the surface, the response speed should be adequate to permit use on continuous mining equipment, and the device should be rugged and otherwise suited for operation under conditions of high vibration, moisture, and dust. Finally, the sensor measurement must not be adversely affected by the natural effects occurring in coal such as impurities, voids, cracks, layering, high moisture level, and other conditions that are likely to be encountered.

King, J. D.↗

Electron-beam flow visualization - Applications in the definition of configuration aerothermal characteristics.

Comparisons between flow visualization systems using electron-beam fluorescence, schlieren, and shadowgraph techniques illustrate the advantages associated with the electron beam. Specific applications of this method as an aid in defining the origin of erosion on a heat-transfer model are cited. Results of combined electron-beam oil-flow studies on configurations illustrate that the simultaneous definition of the external flow field and its surface flow can be obtained. Comparisons between the electron-beam oil-flow visualization method and phase-change coating heat-transfer tests on a shuttle ascent configuration indicate the complementary nature of these two testing techniques. Potential methods for improving the electron-beam technique are included.

Woods, W. C.↗

VHF/UHF technique for the determination of the columnar electron contents of the plasmasphere and of the protonosphere using geostationary satellite transmission: Observations during magnetic storms

Measurements of the total electron content of the plasmasphere up to geostationary heights were made using the beacon transmitters aboard the satellite ATS-3. The technique employed is a combination of the phase-path length difference and the Faraday rotation angle methods. Such a combination permits very accurate determination of the integration constant necessary to convert phase-path length difference data into information about the absolute value of the columnar content.

Almeida, O. G.↗

Surface Diagnostics in Tribology Technology and Advanced Coatings Development

This paper discusses the methodologies used for surface property measurement of thin films and coatings, lubricants, and materials in the field of tribology. Surface diagnostic techniques include scanning electron microscopy, transmission electron microscopy, atomic force microscopy, stylus profilometry, x-ray diffraction, electron diffraction, Raman spectroscopy, Rutherford backscattering, elastic recoil spectroscopy, and tribology examination. Each diagnostic technique provides specific measurement results in its own unique way. In due course it should be possible to coordinate the different pieces of information provided by these diagnostic techniques into a coherent self-consistent description of the surface properties. Examples are given on the nature and character of thin diamond films.

Miyoshi, Kazuhisa↗