Optical method for distance and displacement measurements of the probe-sample separation in a scanning near-field optical microscope

In this work, we present an alternative optical method to determine the probe-sample separation distance in a scanning near-field optical microscope. The experimental method is based in a Lloyd’s mirror interferometer and offers a measurement precision deviation of ∼100 nm using digital image processing and numerical analysis. The technique can also be strategically combined with the characterization of piezoelectric actuators and stability evaluation of the optical system. It also opens the possibility for the development of an automatic approximation control system valid for probe-sample distances from 5 to 500 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soft x-ray spectromicroscopy using compact scanning transmission x-ray microscope at the photon factory

We report the stability and recent performances of a new type of scanning transmission X-ray microscopy. The optics and compact design of the microscope realized mobility and robust performance. Detailed consideration to the vibration control will be described. The insertion device upgraded to elliptical polarization undulator enabled linear dichroism and circular dichroism experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tip-enhanced near-field optical microscope with side-on and ATR-mode sample excitation for super-resolution Raman imaging of surfaces

A tip-enhanced near-field optical microscope with side-on and attenuated total reflectance (ATR) excitation and collection is described and used to demonstrate sub-diffraction-limited (super-resolution) optical and chemical characterization of surfaces. ATR illumination is combined with an Au optical antenna tip to show that (i) the tip can quantitatively transduce the optical near-field (evanescent waves) above the surface by scattering photons into the far-field, (ii) the ATR geometry enables excitation and characterization of surface plasmon polaritons (SPPs), whose associated optical fields are shown to enhance Raman scattering from a thin layer of copper phthalocyanine (CuPc), and (iii) SPPs can be used to plasmonically excite the tip for super-resolution chemical imaging of patterned CuPc via tip-enhanced Raman spectroscopy (TERS). ATR-illumination TERS is also quantitatively compared with the more conventional side-on illumination scheme. In both cases, spatial resolution was better than 40 nm and tip on/tip off Raman enhancement factors were >6500. Furthermore, ATR illumination was shown to provide similar Raman signal levels at lower “effective” pump powers due to additional optical energy delivered by SPPs to the active region in the tip-surface gap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frictionless quantum quenches in ultracold gases: A quantum-dynamical microscope

In this Rapid Communication, a method is proposed to spatially scale up a trapped ultracold gas while conserving the quantum correlations of the initial many-body state. For systems supporting self-similar dynamics, this is achieved by implementing an engineered finite-time quench of the harmonic trap, which induces a frictionless expansion of the gas and acts as a quantum dynamical microscope.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A coded aperture microscope for X-ray fluorescence full-field imaging

The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 µm openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 µm-thick silicon nitride membrane. The gold is 25 µm thick, offering good contrast up to 20 keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.

36 MATERIALS SCIENCE↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MIAMI: Microscope and ion accelerator for materials investigations

A transmission electron microscope (TEM) with in situ ion irradiation has been built at the University of Salford, U.K. The system consists of a Colutron G-2 ion source connected to a JEOL JEM-2000FX TEM via an in-house designed and constructed ion beam transport system. The ion source can deliver ion energies from 0.5 to 10 keV for singly charged ions and can be floated up to 100 kV to allow acceleration to higher energies. Ion species from H to Xe can be produced for the full range of energies allowing the investigation of implantation with light ions such as helium as well as the effects of displacing irradiation with heavy inert or self-ions. The ability to implant light ions at energies low enough such that they come to rest within the thickness of a TEM sample and to also irradiate with heavier species at energies sufficient to cause large numbers of atomic displacements makes this facility ideally suited to the study of materials for use in nuclear environments. TEM allows the internal microstructure of a sample to be imaged at the nanoscale. By irradiating in situ it is possible to observe the dynamic evolution of radiation damage which can occur during irradiation as a result of competing processes within the system being studied. Furthermore, experimental variables such as temperature can be controlled and maintained throughout both irradiation and observation. This combination of capabilities enables an understanding of the underlying atomistic processes to be gained and thus gives invaluable insights into the fundamental physics governing the response of materials to irradiation. Details of the design and specifications of the MIAMI facility are given along with examples of initial experimental results in silicon and silicon carbide.

36 MATERIALS SCIENCE↗

Zone plate-based extreme ultraviolet mask microscope with through-pellicle imaging capability

Mirror-based and zone plate-based imaging systems are being used in actinic extreme ultraviolet (EUV) reticle review tools. With regard to zone plates, a short working distance is advantageous in terms of the required spectral bandwidth, manufacturability, and potential throughput and imaging performance. Zone plates therefore typically have a short working distance. The industry has adopted the use of an EUV pellicle to protect the photomask. Imaging photomask through-pellicle requires a working distance larger than 2.5 mm. A zone-plate-based EUV mask microscope with a 3-mm working distance has been commissioned at beamline 11.3.2 of the Advanced Light Source. Through-pellicle imaging at an exposure time of 2 s is demonstrated. The instrument achieves an image contrast of 95% on large features on a photomask with a tantalum-based absorber. Imaging down to 45-nm half pitch (mask scale) is demonstrated. A NILS of 2.55 is achieved on 60-nm half-pitch (mask scale) lines and spaces. These results demonstrate that zone-plate-based imaging systems can meet the requirements of an actinic EUV mask review tool in terms of imaging performance and throughput in an instrument compatible with EUV pellicles.

Extreme ultraviolet↗

WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line for top-to-bottom exposures. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Poster - 14: Batch Effect Reduction in in-vitro Raman Microscopic Radiosensitivity Study Using Ovarian Cancer Cells

Purpose: To improve classification by reducing batch effect in samples from the ovarian carcinoma cell lines A2780s (parental wild type) and A2780cp (cisplatin cross-radio-resistant), before, right after, and 24 hours after irradiation to 10Gy. Methods: Spectra were acquired with a home built confocal Raman microscope in 3 distinct runs of six samples: unirradiated s&cp (control pair), then 0h and 24h after irradiation. The Raman spectra were noise reduced, then background subtracted with SMIRF algorithm. ∼35 cell spectra were collected from each sample in 1024 channels from 700cm-1 to 1618cm-1. The spectra were analyzed by regularized multiclass LDA. For feature reduction the spectra were grouped into 3 overlapping group pairs: s-cp, 0Gy–10Gy0h and 0Gy10–Gy24h. The three features, the three differences of the mean spectra were mapped to the analysis sub-space by the inverse regularized covariance matrix. The batch effect noticeably confounded the dose and time effect. Results: To remove the batch effect, the 2+2=4D subspace extended by the covariance matrix of the means of the 0Gy control groups was subtracted from the spectra of each sample. Repeating the analysis on the spectra with the control group variability removed, the batch effect was dramatically reduced in the dose and time directions enabling sharp linear discrimination. The cell type classification also improved. Conclusions: We identified a efficient batch effect removal technique crucial to the applicability of Raman microscopy to radiosensitivity studies both on cell cultures and potential clinical diagnostic applications.

60 APPLIED LIFE SCIENCES↗

Effect of high-energy electron irradiation in an electron microscope column on fluorides of alkaline earth elements (CaF{sub 2}, SrF{sub 2}, and BaF{sub 2})

The effect of high-energy (150 eV) electron irradiation in an electron microscope column on crystals of fluorides of alkaline earth elements CaF{sub 2}, SrF{sub 2}, and BaF{sub 2} is studied. During structural investigations by electron diffraction and electron microscopy, the electron irradiation causes chemical changes in MF{sub 2} crystals such as the desorption of fluorine and the accumulation of oxygen in the irradiated area with the formation of oxide MO. The fluorine desorption rate increases significantly when the electron-beam density exceeds the threshold value of {approx}2 Multiplication-Sign 10{sup 3} pA/cm{sup 2}). In BaF{sub 2} samples, the transformation of BaO into Ba(OH){sub 2} was observed when irradiation stopped. The renewal of irradiation is accompanied by the inverse transformation of Ba(OH){sub 2} into BaO. In the initial stage of irradiation of all MF{sub 2} compounds, the oxide phase is in the single-crystal state with a lattice highly matched with the MF{sub 2} matrix. When the irradiation dose is increased, the oxide phase passes to the polycrystalline phase. Gaseous products of MF{sub 2} destruction (in the form of bubbles several nanometers in diameter) form a rectangular array with a period of {approx}20 nm in the sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of Properties of Images with Atomic Resolution in a Scanning Probe Microscope

A method for simulation of images in a scanning probe microscope (SPM) using simultaneous wavelet transform and median filtering is proposed. The wavelet transform with the fourth-order Daubechies kernel is used. Such a transform makes it possible to select details of different scales in the SPM image and, hence, study fractal properties of surfaces. Simulation is used to show that ultrahigh (atomic) resolution is possible in SPM provided that the size of the contact region in the probe–sample system is significantly greater than atomic size and the lattice atoms are randomly distributed. Contrast inversion in the SPM images in the multiscan mode is interpreted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle image identification and correlation analysis in microscopic holographic particle image velocimetry

This paper discusses the different analysis methods used in holographic particle image velocimetry to measure particle displacement and compares their relative performance. A digital holographic microscope is described and is used to record the light scattered by particles deposited on cover slides that are displaced between exposures. In this way, particle position and displacement are controlled and a numerical data set is generated. Data extraction using nearest neighbor analysis and correlation of either the reconstructed complex amplitude or intensity fields is then investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscope spectrometer for light scattering investigations

We describe a setup including a microscope to study volumes of a few {mu}m{sup 3} by static and dynamic light scattering (DLS) in a backscattering configuration. Light scattered by individual objects of micrometric size can be analyzed in the 400-800 nm spectral range. This setup can also be employed to study both diluted and concentrated colloidal solutions by DLS measurements. For diluted solutions we found evidence of the fluctuations of the number of particles in a confocal volume. We discuss their contribution to the autocorrelation function of the scattered intensity measured as a function of time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale Imaging of Whole Cells Using a Liquid Enclosure and a Scanning Transmission Electron Microscope

Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM) using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7) were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wetSTEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM) laboratory.

36 MATERIALS SCIENCE↗

Principles and techniques of the quantum diamond microscope

We provide an overview of the experimental techniques, measurement modalities, and diverse applications of the quantum diamond microscope (QDM). The QDM employs a dense layer of fluorescent nitrogen-vacancy (NV) color centers near the surface of a transparent diamond chip on which a sample of interest is placed. NV electronic spins are coherently probed with microwaves and optically initialized and read out to provide spatially resolved maps of local magnetic fields. NV fluorescence is measured simultaneously across the diamond surface, resulting in a wide-field, two-dimensional magnetic field image with adjustable spatial pixel size set by the parameters of the imaging system. NV measurement protocols are tailored for imaging of broadband and narrowband fields, from DC to GHz frequencies. Here we summarize the physical principles common to diverse implementations of the QDM and review example applications of the technology in geoscience, biology, and materials science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and the team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.

42 ENGINEERING↗