Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Validation of a DIXON-based fat quantification technique for the measurement of visceral fat using a CT-based reference standard

Purpose: The purpose of the study is to determine whether a novel semi-automated DIXON-based fat quantification algorithm can reliably quantify visceral fat using a CT-based reference standard. Methods: This was an IRB-approved retrospective cohort study of 27 subjects who underwent abdominopelvic CT within 7 days of proton density fat fraction (PDFF) mapping on a 1.5T MRI. Cross-sectional visceral fat area per slice (cm{sup 2}) was measured in blinded fashion in each modality at intervertebral disc levels from T12 to L4. CT estimates were obtained using a previously published semi-automated computational image processing system that sums pixels with attenuation − 205 to − 51 HU. MR estimates were obtained using two novel semi-automated DIXON-based fat quantification algorithms that measure visceral fat area by spatially regularizing non-uniform fat-only signal intensity or de-speckling PDFF 2D images and summing pixels with PDFF ≥ 50%. Pearson’s correlations and Bland–Altman analyses were performed. Results: Visceral fat area per slice ranged from 9.2 to 429.8 cm{sup 2} for MR and from 1.6 to 405.5 cm{sup 2} for CT. There was a strong correlation between CT and MR methods in measured visceral fat area across all studied vertebral body levels (r = 0.97; n = 101 observations); the least (r = 0.93) correlation was at T12. Bland–Altman analysis revealed a bias of 31.7 cm{sup 2} (95% CI [− 27.1]–90.4 cm{sup 2}), indicating modestly higher visceral fat assessed by MR. Conclusion: MR- and CT-based visceral fat quantification are highly correlated and have good cross-modality reliability, indicating that visceral fat quantification by either method can yield a stable and reliable biomarker.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of plutonium, 237 Np, and 137 Cs in the BCR 482 lichen reference material

Select anthropogenic radionuclides were measured in lichen reference material, BCR 482. This material was originally collected in Axalp, Switzerland in 1991 and is composed of the epiphytic lichen Pseudevernia furfuracea . Samples from three separate bottles of BCR 482 were analyzed for uranium, neptunium, and plutonium isotopes by inductively coupled plasma mass spectrometry (ICP-MS) and analyzed for cesium-137 by gamma-ray spectrometry. The isotopic composition of the radionuclides measured in BCR 482 suggests contributions from both global fallout resulting from historical nuclear weapons testing and more volatile materials released following the Chernobyl accident.

54 ENVIRONMENTAL SCIENCES↗

An interlaboratory collaboration to determine consensus 231 Pa/ 235 U model ages of a uranium certified reference material for nuclear forensics

Application of the 231 Pa/ 235 U radiochronometer for nuclear forensic investigations is challenged by a lack of certified reference materials with 231 Pa/ 235 U model purification dates. The Japan Atomic Energy Agency, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory completed an interlaboratory study measuring 231 Pa/ 235 U model ages of New Brunswick Laboratory CRM U100. Results from independent laboratories were combined to calculate a consensus 231 Pa/ 235 U model purification date for CRM U100 of March 26, 1959 ± 237 days. This 231 Pa/ 235 U consensus date for CRM U100 may be used by the nuclear forensic community for quality control of 231 Pa/ 235 U radiochronometry measurements of unknown materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comorbid conditions in individuals assessed by SPECT: Study of a reference cardiology center in Mexico City

Background: There is an increasing prevalence of comorbidities in patients with ischemic heart disease (IHD) in developing countries. The aim of this work is to assess the prevalence of comorbidities and associated factors for IHD among patients at a reference cardiology center. Design and Methods: This was a cross-sectional study. A complete clinical history which focused on the main comorbidities, previous myocardial infarction, and the main reason of referral was assessed. A single-photon emission computed tomography (SPECT) myocardial perfusion study (MPS) with two protocols was performed. Results: We included 1998 patients, 64.2% male, median age 63 (I.R.: 56–71) years. 1514 (75.8%) subjects had at least one associated comorbidity. The main comorbidity was diabetes (T2D) (772: 38.6%), followed by systemic hypertension (737: 36.9%), smoking (518: 25.9%), and dyslipidemia (517: 25.9%). 806 (40.3%) had histories of previous myocardial infarctions. The main cause of referral was angina (923: 46.2%). We identified 1330 (66.5%) abnormal MPS. 460 (23%) had ischemia, 292 (14.6%) infarction, and 578 (28.9%) ischemia and infarction. Conclusion: An increased prevalence of comorbidities was found in patients who were studied in the Nuclear Cardiology Department (NCD): most of them had traditional risk factors attributable to myocardial infarction. A great percentage were newly diagnosed with both ischemia and infarction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blockchain Smart Contract Reference Framework and Program Logic Architecture for Transactive Energy Systems

This paper proposes a reference framework for a transactive energy market based on blockchain. The framework was designed based on the engineering requirements of a distribution-scale market; including participant needs, expected market transactions, and the cybersecurity constructs required to support a fair, secure and efficient market operation. It leverages the existing blockchain primitives to provide clear value propositions to the transactive market, including identity management (access control), data security (integrity), resiliency (decentralization, scalability and performance). The validity of the proposed framework is demonstrated using a real-time 5-min double-auction market. The results highlight its benefits while providing strong validation of applicability to blockchain within transactive energy systems.

Gourisetti, Sri Nikhil Gupta↗

The importance of the membrane interface as the reference state for membrane protein stability

The insertion of nascent polypeptide chains into lipid bilayer membranes and the stability of membrane proteins crucially depend on the equilibrium partitioning of polypeptides. For this, the transfer of full sequences of amino-acid residues into the bilayer, rather than individual amino acids, must be understood. Earlier studies have revealed that the most likely reference state for partitioning very hydrophobic sequences is the membrane interface. We have used μs-scale simulations to calculate the interface-to-transmembrane partitioning free energies ΔG S→TM for two hydrophobic carrier sequences in order to estimate the insertion free energy for all 20 amino acid residues when bonded to the center of a partitioning hydrophobic peptide. Our findings reflect that prior single-residue scales likely overestimate the partitioning free energies of polypeptides. The correlation of ΔG S→TM with experimental full-peptide translocon insertion data is high, implying an important role for the membrane interface in translocon-based insertion. The choice of carrier sequence greatly modulates the contribution of each single-residue mutation to the overall partitioning free energy. Our results demonstrate the importance of quantifying the observed full-peptide partitioning equilibrium, which is between membrane interface and transmembrane inserted, rather than combining individual water-to-membrane amino acid transfer free energies.

59 BASIC BIOLOGICAL SCIENCES↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A reduced chemical kinetic model for IC engine combustion simulations with primary reference fuels

A reduced chemical kinetic mechanism for the oxidation of primary reference fuel (PRF) has been developed and applied to model internal combustion engines. Starting from an existing reduced reaction mechanism for n-heptane oxidation, a new reduced n-heptane mechanism was generated by including an additional five species and their relevant reactions, by updating the reaction rate constants of several reactions pertaining to oxidation of carbon monoxide and hydrogen, and by optimizing reaction rate constants of selected reactions. Using a similar approach, a reduced mechanism for iso-octane oxidation was built and combined with the n-heptane mechanism to form a PRF mechanism. The final version of the PRF mechanism consists of 41 species and 130 reactions. Validation of the present PRF mechanism was performed with measurements from shock tube tests, and HCCI and direct injection engine experiments available in the literature. The results show that the present PRF mechanism gives reliable performance for combustion predictions, as well as computational efficiency improvements for multidimensional CFD simulations. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Dataset describing two reference models for full-spectral lighting and daylight simulations together with implementations for two software systems

A dataset of two spectral lighting simulation reference models - one office and one factory hall - is presented. It aims to demonstrate and support full-spectral daylight and electric lighting simulations and facilitate evaluation of non-visual effects of light. The dataset includes Rhino CAD geometry, comprehensive spectral material and light source data and window system BSDF data. Example implementations in the two software tools, Radiance and OWL, enable reproducible workflows and support adoption in other software. The dataset is openly available on Zenodo. The office model reproduces Room 518 at the University of Innsbruck, including a west-facing façade and interior furnishings. The factory hall model follows the proposed geometry in the European standard 15193 for building energy performance. Interior reflectances in the office were measured in-situ using a handheld spectrometer. Exterior spectra and factory hall materials matching specified reflectances were obtained from an online spectral materials database. Glazing transmittance was derived from IGDB data using LBNL Optics/WINDOW. BSDFs for venetian blinds at various tilt angles, and for a diffusing pane adapted from the Complex Glazing Database, were generated in WINDOW. Luminaires in both models are specified with photometric files (Eulumdat/IES) and lamp spectra (Fluorescent 840, 4000 K LED). The provided example implementations (Radiance, OWL) include prepared input data and scripts to run first spectral simulations; example results are also included. The dataset is prepared to support reuse by researchers, designers and software developers for method validation, software engineering and comparison, and development of spectral metrics and controls.

Geisler-Moroder, David↗

Application of the hybrid approach to the benchmark dose of urinary cadmium as the reference level for renal effects in cadmium polluted and non-polluted areas in Japan

Objectives: The aim of this study was to evaluate the reference level of urinary cadmium (Cd) that caused renal effects. An updated hybrid approach was used to estimate the benchmark doses (BMDs) and their 95% lower confidence limits (BMDL) in subjects with a wide range of exposure to Cd. Methods: The total number of subjects was 1509 (650 men and 859 women) in non-polluted areas and 3103 (1397 men and 1706 women) in the environmentally exposed Kakehashi river basin. We measured urinary cadmium (U-Cd) as a marker of long-term exposure, and {beta}2-microglobulin ({beta}2-MG) as a marker of renal effects. The BMD and BMDL that corresponded to an additional risk (BMR) of 5% were calculated with background risk at zero exposure set at 5%. Results: The U-Cd BMDL for {beta}2-MG was 3.5 {mu}g/g creatinine in men and 3.7 {mu}g/g creatinine in women. Conclusions: The BMDL values for a wide range of U-Cd were generally within the range of values measured in non-polluted areas in Japan. This indicated that the hybrid approach is a robust method for different ranges of cadmium exposure. The present results may contribute further to recent discussions on health risk assessment of Cd exposure.

60 APPLIED LIFE SCIENCES↗

A predictive 0-D HCCI combustion model for ethanol, natural gas, gasoline, and primary reference fuel blends

Homogeneous Charge Compression Ignition (HCCI) is a promising advanced combustion concept with high thermal efficiency and low exhaust emissions. This work purposes a computationally-efficient, zero-dimensional (0-D) HCCI combustion model that does not need to solve any differential equations. To develop the burn rate correlations, experimental HCCI data of ethanol, natural gas, E10-gasoline, and Primary Reference Fuel (PRF) blends was collected on a CFR engine. The burn rate model is built based on the individual cycle mass fraction burned (MFB) curves calculated from the experimental data. CA0 can be predicted from an ignition delay correlation. Once CA0 is known, CA50 and CA90 can be predicted based on CA0 and the charge-mass equivalence ratio Φ'. Then, with CA0, 50 and 90 known, a Wiebe function can be constructed to represent the MFB curve and burn rate. For PRF blends, low-temperature and high-temperature heat releases (LTHR and HTHR) are modeled by two Wiebe functions with Φ' and PRF number dependence. The fitted model has high accuracy compared to the experimental data with R 2 values generally greater than 0.97. Finally, various ignition delay correlations from the literature are also tested against the experimentally collected data and some modifications to the correlations are suggested.

42 ENGINEERING↗

Measurements of the thermal conductivity of reference liquids using a modified transient hot-wire needle probe

Many power generation processes feature some type of working fluid that plays a critical role in the transfer of heat throughout the system. To optimize thermal efficiencies, an accurate characterization of the temperature-dependent thermal conductivity of the fluid is needed. Herein, this study develops a time-domain Modified Transient Hot-wire Needle Probe to overcome phenomena that have impaired traditional measurement techniques when the fluid is both corrosive and at an elevated temperature. First, the physical design of the instrument is presented to demonstrate features that limit interference from corrosion, electrical conduction, and convective and radiative heat transfer. Next, a governing equation for 1D (radial) heat conduction is fully developed using the thermal quadrupoles technique. A finite-element study is performed for validation. A sensitivity analysis is done to assess the time-dependent influence of critical parameters in the governing equation for several samples. Finally, thermal conductivity measurements are presented for seven different liquid substances by fitting the thermal model to experimental data across a range of temperatures. Reference correlations are included for comparison. The sample thermal conductivity and ambient temperature of the experimental conditions range from 0.125–16.5$\frac{W}{m·K}$ and 10–400°C, respectively. The total uncertainty, comprised of both the experimental design and fitting process, of all measurements is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium Isotopic Ratio Measurements of U3O8 Reference Materials by Atom Probe Tomography

We report results of measurements of isotopic ratios obtained with atom probe tomography on U3O8 reference materials certified for their isotopic abundances of uranium. The results show good agreement with the certified values. High backgrounds due to tails from adjacent peaks complicate the measurement of the integrated peak areas as well as the fact that only oxides of uranium appear in the spectrum, the most intense of which is doubly charged. In addition, lack of knowledge of other instrumental parameters, such as the dead time, may bias the results. Isotopic ratio measurements can be performed at the nanometer-scale with the expectation of sensible results. The abundance sensitivity and mass resolving power of the mass spectrometer are not sufficient to compete with magnetic-sector instruments but are not far from measurements made by ToF-SIMS of other isotopic systems. The agreement of the major isotope ratios is more than sufficient to distinguish most anthropogenic compositions from natural.

Atom Probe Tomography↗

Insights from incorporating reference electrodes in symmetric lithium-ion cells with layered oxide or graphite electrodes

Symmetric cells provide complementary means to probe electrochemical processes in lithium-ion batteries. Here, positive and negative electrodes harvested from conventional oxide/graphite cells are cross-paired, and the assembled reference-electrode-bearing symmetric cells are cycled/aged. For graphite symmetric cells, the electrode potentials and impedances remain nearly constant during calendar aging and the parasitic currents are typically small. However, at higher cell voltages when the “positive” graphite potential exceeds 1.0 V vs. Li/Li + , the capacity loss is higher, indicating that even a mild (but prolonged) overdischarge can damage the SEI. For the layered-oxide symmetric cells there are strong parasitic currents and a persistent slide of the electrode potential over time during calendar aging. Significant cell impedance rise, especially at higher hold voltages, is also observed. Curiously, the impedance rise in the “negative” oxide electrode, which experiences potentials below 4.0 V vs. Li/Li + , is greater than in the “positive” oxide electrode that experiences much higher potentials. We postulate that electrolyte oxidation is responsible for the behavior of these oxide symmetric cells, as it supplies electrons (that bind more Li + into the cathode, causing the potential slide) and protons (that contribute to impedance rise). Furthermore, these insights can guide the development of future lithium-ion cell chemistries.

25 ENERGY STORAGE↗

Electrophoretic deposition for improved trace element homogeneity in silica reference materials

Spatially-resolved analysis requires homogeneous reference materials (RMs) to make reliable quantitative measurements. Here we previously developed an electrophoretic deposition (EPD) method for fabrication of glassy microanalytical RMs with superior platinum-group element homogeneity **[1], and now include further dopants. For 39 trace elements, we analyzed dopant homogeneity in sintered silica (SiO 2 ) samples consolidated either mechanically by die-pressing (DP) or by EPD. A set of EPD and DP samples was made from each of two nanoparticle feedstocks produced by variations of the Stöber process **[2]. Spatially-resolved dopant distribution was characterized in all samples by laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS). In both sample sets, homogeneity of most trace elements was substantially improved by EPD relative to their DP counterpart.

36 MATERIALS SCIENCE↗