Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Innovative FT-IR Imaging of Protein Film Secondary Structure Before and After Heat Treatment

Changes in the secondary structure of globular protein occur during thermal processing. An infrared reflecting mirrored optical substrate that is unaffected by heat allows recording infrared spectra of protein films in a reflection absorption mode on the stage of an FT-IR microspectrometer. Hydrated films of myoglobin protein cast from solution on the mirrored substrate are interrogated before and after thermal denaturation to allow a direct comparison. Focal plane array imaging of 280 protein films allowed selection of the same area in the image from which to extract spectra. After treatment, 110 of 140 spectra from multiple films showed a dramatic shift from the {alpha}-helix form (1650 {+-} 5 cm{sup -1}) to aggregated forms on either side of the original band. Seventy maxima were near 1625 cm{sup -1}, and 40 shifted in the direction of 1670 cm{sup -1}. The method developed was applied to films cast from two other commercial animal and plant protein sources.

59 BASIC BIOLOGICAL SCIENCES↗

Data supporting the manuscript "Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure"

This dataset contains atomic force microscopy images associated with the manuscript "Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure" by Maria Kelly, Emily R. Dunn, Ellis A. Spickermann, Josephine N. Gruber, César A. Lasalde-Ramírez, P. N. Romero Zavala, Éowyn Lucas, Ankur Gupta, Harry A. Atwater, and Wilson A. Smith. The dataset contains both raw images as well as segmented images produced by the image processing workflow described in the manuscript. A readme file and meta data file are included to provide additional details regarding the sample identity, image acquisition parameters, and file naming scheme.

36 MATERIALS SCIENCE↗

In-Vacuum Photogrammetry of a Ten-Meter Square Solar Sail

Solar sailing is a promising, future in-space propulsion method that uses the small force of reflecting sunlight to accelerate a large, reflective membrane without expendable propellants. One of two solar sail configurations under development by NASA is a striped net approach by L'Garde, Inc. This design uses four inflatably deployed, lightweight booms supporting a network of thin strings onto which four quadrants of ultrathin aluminized membranes are attached. The NASA Langley Research Center (LaRC) provided both experimental and analytical support to L'Garde for validating the structural characteristics of this unique, ultralightweight spacecraft concept. One of LaRC's responsibilities was to develop and apply photogrammetric methods to measure sail shape. The deployed shape provides important information for validating the accuracy of finite-element modeling techniques. Photogrammetry is the science and art of calculating 3D coordinates of targets or other distinguishing features on structures using images. A minimum of two camera views of each target is required for 3D determination, but having four or more camera views is preferable for improved reliability and accuracy. Using retroreflective circular targets typically provides the highest measurement accuracy and automation. References 3 and 4 provide details of photogrammetry technology, and reference 5 discusses previous experiences with photogrammetry for measuring gossamer spacecraft structures such as solar sails. This paper discusses the experimental techniques used to measure a L Garde 10-m solar sail test in vacuum with photogrammetry. The test was conducted at the NASA-Glenn Space Power Facility (SPF) located at Plum Brook Station in Sandusky, Ohio. The SPF is the largest vacuum chamber in the United States, measuring 30 m in diameter by 37 m in height. High vacuum levels (10(exp -6) torr) can be maintained inside the chamber, and cold environments (-195 C) are possible using variable-geometry cryogenic cold walls. This test used a vacuum level of approximately 1 torr (sufficient for structural static/dynamic characterization) and instead of using the cryogenic cold walls, used local LN2 cold plates underneath each of the four cold-rigidizable solar sail booms instead.

Pappa, Richard S.↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

Tunable Tensor Voting Improves Grouping of Membrane-Bound Macromolecules

Membrane-bound macromolecules are responsible for structural support and mediation of cell-cell adhesion in tissues. Quantitative analysis of these macromolecules provides morphological indices for damage or loss of tissue, for example as a result of exogenous stimuli. From an optical point of view, a membrane signal may have nonuniform intensity around the cell boundary, be punctate or diffused, and may even be perceptual at certain locations along the boundary. In this paper, a method for the detection and grouping of punctate, diffuse curvilinear signals is proposed. Our work builds upon the tensor voting and the iterative voting frameworks to propose an efficient method to detect and refine perceptually interesting curvilinear structures in images. The novelty of our method lies on the idea of iteratively tuning the tensor voting fields, which allows the concentration of the votes only over areas of interest. We validate the utility of our system with synthetic and annotated real data. The effectiveness of the tunable tensor voting is demonstrated on complex phenotypic signals that are representative of membrane-bound macromolecular structures.

60 APPLIED LIFE SCIENCES↗

Effect of GLAD technique on optical properties of ZnS multilayer antireflection coatings

Highlights: • ZnS multi-layer antireflection coatings have been prepared by GLAD technique. • XRD analysis depicts that all the multi-layer samples are crystallized in cubic structure. • FESEM images confirmed the multi-layer and inclined formation of specimens. • Transmission increment and refractive index decrement obtained for the multi-layer samples. • Incredible impression of GLAD technique on multi-layer coatings is realized. - Abstract: In this work, we prepared Zinc sulfide (ZnS) multi-layer antireflection coatings applying glancing angle deposition (GLAD) technique by physical vapor deposition method. By comparing the structural and optical properties of the samples prepared at normal and inclined single layer coatings, salient effect of multi-layer coatings composed of normal and inclined layers are observed. Relative improvement in crystallinity of the GLAD produced films with respect to inclined single layer resulted from X-ray diffraction (XRD) studies. Despite high increment in average transmission, explicit reduction in refractive index of the multilayer specimens are obtained by Ultraviolet–visible spectroscopy (UV–VIS) analysis. Both the abovementioned changes are in the direction of improving the anti-reflectivity features.

36 MATERIALS SCIENCE↗

Femtosecond gas-phase mega-electron-volt ultrafast electron diffraction

The development of ultrafast gas electron diffraction with nonrelativistic electrons has enabled the determination of molecular structures with atomic spatial resolution. It has, however, been challenging to break the picosecond temporal resolution barrier and achieve the goal that has long been envisioned—making space- and-time resolved molecular movies of chemical reaction in the gas-phase. Recently, an ultrafast electron diffraction (UED) apparatus using mega-electron-volt (MeV) electrons was developed at the SLAC National Accelerator Laboratory for imaging ultrafast structural dynamics of molecules in the gas phase. The SLAC gas-phase MeV UED has achieved 65 fs root mean square temporal resolution, 0.63 Å spatial resolution, and 0.22 Å−1 reciprocal-space resolution. Such high spatial-temporal resolution has enabled the capturing of real-time molecular movies of fundamental photochemical mechanisms, such as chemical bond breaking, ring opening, and a nuclear wave packet crossing a conical intersection. In this paper, the design that enables the high spatial-temporal resolution of the SLAC gas phase MeV UED is presented. The compact design of the differential pump section of the SLAC gas phase MeV UED realized five orders-of-magnitude vacuum isolation between the electron source and gas sample chamber. The spatial resolution, temporal resolution, and long-term stability of the apparatus are systematically characterized.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simulation of High-Harmonic Fast-Wave Heating on the National Spherical Tokamak Experiment

Images associated with radio-frequency heating of low-confinement mode plasmas in the National Spherical Tokamak Experiment, as calculated by computer simulation, are presented. The AORSA code has been extended to simulate the whole antenna-to-plasma heating system by including both the kinetic physics of the well-confined core plasma and a poorly confined scrape-off plasma and vacuum vessel structure. The images presented show the 3-D electric wave field amplitude for various antenna phasings. Visualization of the simulation results in 3-D makes clear that -30 degrees phasing excites kilo-volt per meter coaxial standing modes in the scrape-off plasma and shows magnetic-field-aligned whispering-gallery type modes localized to the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging the Schwarzschild-radius-scale Structure of M87 with the Event Horizon Telescope Using Sparse Modeling

We propose a new imaging technique for radio and optical/infrared interferometry. The proposed technique reconstructs the image from the visibility amplitude and closure phase, which are standard data products of short-millimeter very long baseline interferometers such as the Event Horizon Telescope (EHT) and optical/infrared interferometers, by utilizing two regularization functions: the ℓ {sub 1}-norm and total variation (TV) of the brightness distribution. In the proposed method, optimal regularization parameters, which represent the sparseness and effective spatial resolution of the image, are derived from data themselves using cross-validation (CV). As an application of this technique, we present simulated observations of M87 with the EHT based on four physically motivated models. We confirm that ℓ {sub 1} + TV regularization can achieve an optimal resolution of ∼20%–30% of the diffraction limit λ / D {sub max}, which is the nominal spatial resolution of a radio interferometer. With the proposed technique, the EHT can robustly and reasonably achieve super-resolution sufficient to clearly resolve the black hole shadow. These results make it promising for the EHT to provide an unprecedented view of the event-horizon-scale structure in the vicinity of the supermassive black hole in M87 and also the Galactic center Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-imaging of molecules from diffraction spectra by laser-induced rescattering electrons

We study high-energy angle-resolved photoelectron spectra of molecules in strong fields. In an oscillating laser electric field, electrons released earlier in the pulse may return to recollide with the target ion, in a process similar to scattering by laboratory prepared electrons. If midinfrared lasers are used, we show that the images generated by the returning electrons are similar to images observed in typical gas-phase electron diffraction (GED). These spectra can be used to retrieve the positions of atoms in a molecule as in GED. Since infrared laser pulses of durations of a few femtoseconds are already available today, the study of these high-energy photoelectrons offers the opportunity of imaging the structure of transient molecules with temporal resolution of a few femtoseconds.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron beam-induced nanopatterning of multilayer graphene and amorphous carbon films with metal layers

Thin Co and Ni lamellae grow under electron irradiation of metal crystals supported on multilayer graphene or amorphous carbon films. The lateral growth of a lamella from a source crystal is achieved by directing an electron beam to the periphery of the metal crystal and moving the beam over the surrounding carbon. Patterns of linear, branched, or ringlike metal lamellae can be created. The patterning is carried out in situ in a transmission electron microscope, allowing simultaneous structuring and imaging. The process is driven by the metal-carbon interaction at a beam-activated carbon surface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Evaluation of LANDSAT-1 image applications to geologic mapping, structural analysis and mineral resource inventory of South America with special emphasis on the Andes Mountain region

The author has identified the following significant results. The discovery of copper mineralization along a lineament mapped in Area 7 (La Paz) has lent credence to the use of LANDSAT 1 data as a basic step in mineral exploration. In Area 9 (Copiapo Region), a number of lineaments were found to be associated with the largest copper deposits of the region. In Area 12 (Magallanes), the identification of what is believed to be a tertiary basin from LANDSAT 1 data has resulted in a new area for petroleum exploration. Band 7 images, as black and white transparencies, were found to be the most useful for geologic interpretation in both tropical vegetated areas and desert regions. Color composites made by the diazochrome process, chromaline process, and from color additive viewers provided additional information. Mosaics of LANDSAT 1 data covering 4 x 6 degrees of latitude and longitude compiled at the 1:1,000,000 scale were found to be an ideal size and format for most users.

Carter, W. D.↗

TH-C-18A-11: Investigating the Minimum Scan Parameters Required to Generate Free-Breathing Fast-Helical CT Scans Without Motion-Artifacts

Purpose: A recently proposed 4D-CT protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artifacts, which arise when tissue motion is greater than scan speed. This work identifies the minimum scanner parameters required to successfully generate free-breathing fast-helical scans without doubling-artifacts. Methods: 10 patients were imaged under free breathing conditions 25 times in alternating directions with a 64-slice CT scanner using a low dose fast helical protocol. A high temporal resolution (0.1s) 4D-CT was generated using a patient specific motion model and patient breathing waveforms, and used as the input for a scanner simulation. Forward projections were calculated using helical cone-beam geometry (800 projections per rotation) and a GPU accelerated reconstruction algorithm was implemented. Various CT scanner detector widths and rotation times were simulated, and verified using a motion phantom. Doubling-artifacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Results: Increasing amounts of doubling-artifacts were observed with increasing rotation times > 0.2s for 16×1mm slice scan geometry. No significant increase in doubling artifacts was observed for 64×1mm slice scan geometry up to 1.0s rotation time although blurring artifacts were observed >0.6s. Using a 16×1mm slice scan geometry, a rotation time of less than 0.3s (53mm/s scan speed) would be required to produce images of similar quality to a 64×1mm slice scan geometry. Conclusion: The current generation of 16 slice CT scanners, which are present in most Radiation Oncology departments, are not capable of generating free-breathing sorting-artifact-free images in the majority of patients. The next generation of CT scanners should be capable of at least 53mm/s scan speed in order to use a fast-helical 4D-CT protocol to generate a motion-artifact free 4D-CT. NIH R01CA096679.

60 APPLIED LIFE SCIENCES↗

Digital image processing of Seabeam bathymetric data for structural studies of seamounts near the East Pacific Rise

The problem of displaying information on the seafloor morphology is attacked by utilizing digital image processing techniques to generate images for Seabeam data covering three young seamounts on the eastern flank of the East Pacific Rise. Errors in locations between crossing tracks are corrected by interactively identifying features and translating tracks relative to a control track. Spatial interpolation techniques using moving averages are used to interpolate between gridded depth values to produce images in shaded relief and color-coded forms. The digitally processed images clarify the structural control on seamount growth and clearly show the lateral extent of volcanic materials, including the distribution and fault control of subsidiary volcanic constructional features. The image presentations also clearly show artifacts related to both residual navigational errors and to depth or location differences that depend on ship heading relative to slope orientation in regions with steep slopes.

Edwards, M. H.↗

Robust surface coating for a fast, facile fluorine-18 labeling of iron oxide nanoparticles for PET/MR dual-modality imaging

Grafting a robust organic shell around inorganic nanoparticles can optimize their colloidal features to dramatically improve their physicochemical properties. Here, we have developed a polymer coating procedure for providing colloidal stability to the nanoparticles and, more importantly, for applying a fast, facile fluorine-18 labeling of iron oxide nanoparticles (IONPs) for positron emission tomography (PET)/magnetic resonance (MR) dual-modality imaging. The structure of the amphiphilic polymer is based on a backbone of polyacrylic acid, conjugated with multiple oleylamines to form a comb-like branched structure. The dense polymer shell provides high colloidal stability to the IONPs against harsh conditions such as high temperature, low pH value, and high ion strength. By incorporating a 1,4,7-triazacyclononane (NOTA) chelator to the comb-like amphiphilic polymer for the chelation of aluminum fluoride ions, we applied a one-step radiolabeling approach for a fast, facile radiofluorination of magnetic nanoparticles. The new strategy can significantly reduce the procedure time and radiation exposure. In conclusion, the PET/MR dual modality imaging was successfully achieved in living subjects by using 18 F labeled magnetic nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A device-dependent interface for interactive image display

The structure of the device independent Display Management Subsystem (DMS) and the interface routines that are available to the applications programmer for use in developing a set of portable image display utility programs are described.

Perkins, D. C.↗